Irrigation Department has published Tender For Strengthening Of Animal Breeding Farm At Kalsi (2- Development Of Agriculture System - Construction Of Watch Tower, Agriculture Store, Agriculture Land Development, Open Cow Enclosure, Chaff Cutting Shed, Parking Shed, Bio Gas Plant) In Di. Submission Date for this Tender is 24-01-2023. wrist watch Tenders in kalsi Uttarakhand. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 18-Jan-2023 | DATE EXTENSION | Date | 24-01-2023 |
Sl. No. | Item Description |
1 | Earth work in excavation in trenches for foundation and for pipes cables etc. in ordinary soil including fitup to 1.5m and dressing of sides and ramming bottoms and disposal of surplus excavated earth as directed by the engineer with in a lead of 50m. |
2 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
3 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/LindanE.C. 20% with 1% concentration |
4 | Providing and laying in position cement concrete 1:4:8(1cement :4 coarse sand:08graded brick aggregated 40mm .nominal size.) excluding the cost of centering and shuttering - All work upto plinth level |
5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size |
7 | Providingand laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level 1:1:2(1 cement : 1 coarse sand : 1 graded stone cu.m aggregate 20 mm nominal size) |
8 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. uptofloor five level excluding cost of centring,shuttering, finishing and reinforcement1:1.5:3(1 cement : 1.5 coarse sand : 3 graded stone cu.m aggregate 20 mm nominal size) |
9 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).All works upto plinth level |
10 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).All works above plinth level upto floor V level |
11 | Centering shuttering including strutting, propping etc. and removal of form work |
12 | FOUNDATION UP TO PLINTH |
13 | COL SUPER STRUCTURE |
14 | Roof Beam |
15 | Slab |
16 | Lintel Bend+sunshed |
17 | Reinforcement for R.C.C work including straighting,cutting,bending ,placing in position and bending all completeThermo-Mechanically Treated bars. |
18 | 230 th Brick work with brick of class designation 75 in foundation & plinth in cement mortar 1:6 |
19 | Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks 1:6 (1cement : 6 coarse sand) |
20 | Brick work with F.P.S bricks of class 75 in super structure abovestructure above plinth level up to floor five level in all shapes and sizes incement mortar 1:6 (1 cement : 6 coarse sand ) |
21 | Filling available excavated earth (excluding rock) in trenches ,plinth,sides of foundation etc . in layers not exceeding 20cm indepth ,consolidatingeach deposited layer by ramming and watering lead upto 50m and lift upto 1.5m . |
22 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
23 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1cement :3 coarsesand : 6graded stoneaggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth |
24 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means,including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile B Fixing with adjustable |
25 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineerin-charge:(profile c) Fixing with adjustable lugs with split end tail to each jamb |
26 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
27 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). |
28 | Providing & fixing of wire mesh (mosquito jalli) with labour & material comleteWith 12 mm mild steel U beading. |
29 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with4.0 mm thick glass panes |
30 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
31 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
32 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.20 mm cement plaster |
33 | 12mm thick plaster on the plain in side of mix 1:6 ( 1 cement : 6 fine sand) mortar |
34 | 15mm thick plaster on the plain in side of mix 1:6 ( 1 cement : 6 fine sand) mortar |
35 | 6mm thick cementplaster of ceiling of mix 1:3 ( 1 cement : 3 fine sand) mortar |
36 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
37 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
38 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including water thinnable priming coat with cement primer |
39 | White washing with lime to give and even shade new work three or more coats |
40 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
41 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
42 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable sq.m shade with ordinary paint of approved brand and manufacture. |
43 | Providing and laying virtified floor tiles in different sizes (thickness to be speciffied by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved make,in all colours and shades,laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand),jointing with grey cement slurry @3.3kg/sqm including grouting the joints with white cement and matching pigments etc,complete. size of tile 600x600 mm |
44 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
45 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). |
46 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube |
47 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) |
48 | Cement plaster skirting (up to 30 cm height) with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement. 18 mm thick |
49 | Providing trimix process for cc road including all material labour and t&p etccomplete |
50 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4mm thick |
51 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
52 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
53 | Steel work in built up tubular trusses including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete Hot finished welded type tubes. |
54 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture |
55 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/ m² |
56 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.60 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) |
57 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.60 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth) |
58 | Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Rockwool conforming to IS: 8183,density 48 kg/ m3, 50 mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. |
59 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., |
60 | P/F1st quality ceramic glazed wall tiles conforming to IS : 15622 of approved make in colours , shades except burgandy , bottel green , black of any sizes as approved by Engineer -in -Charge in skirting , risers of steps and dados over 12 mm thick bed of cement mortar 1:3 and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
61 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
62 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
63 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm |
64 | Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand)Medium shade pigment using 50% white cement, 50% ordinary cement |
65 | Providing and fixing PTMT door catcher of length 72 mm and dia.of 42 mm with suitable washers weighing not less than 33 gms. |
66 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete |
67 | 100x10 mmx18 mm weighing not less than 78 gms |
68 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
69 | Providing and fixing chromium plated brass handles with necessary screws etc. complete: |
70 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. |
71 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs . (c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge |
72 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
73 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, 2 way modular switch,modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
74 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
75 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
76 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
77 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
78 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
79 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.(20) 2 pair |
80 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20mm (T.V+Telephone+Network) |
81 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
82 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
83 | 1 or 2 Module (75 mmX75 mm) |
84 | 3 Module (100 mmX75 mm) |
85 | 4 Module (125 mmX75 mm) |
86 | 6 Module (200 mmX75 mm) |
87 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
88 | 1 or 2 Module |
89 | 3 Module |
90 | 4 Module |
91 | 6 Module |
92 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
93 | Supplying and flxing brass batten/angle holder including connection etc. as required. |
94 | Installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
95 | Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required. |
96 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
97 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. |
98 | 1 run of cable |
99 | 2 run of cable |
100 | 3 run of cable |
101 | Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator) |
102 | 4 way (4 + 12), Double door |
103 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
104 | Single pole |
105 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
106 | 40 amps |
107 | 63 amps |
108 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
109 | Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
110 | Providing and fixing M.V. danger notice plate of 200 mm X 150mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
111 | Supply of AC 230/250 volts, 50 HZ energy efficient ceiling fan with standard down rod, blades, 2 nos. caps etc. complete (Make : Bajaj /Crompton / Havells) |
112 | 1200 mm sweep |
113 | 300 mm sweep 900 rpm |
114 | Supply of factory wired HPF box type fluorescent tube light fitting suitable fir 1X36 w FTL T5fluorescent tube complete including tubes etc. on surface complete in all respects.MAKE-havells/bajaj/philiphs |
115 | S/F hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16 SWG M.S. sheet incorporating 16mm dia. M.S. round bar duly bent for supporting fan hanger duly painted with red oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting Alongwith supply of all material, labour T&P required for proper completion of work. |
116 | Supply and fixing of 16 gauge M.S. drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respects. For 12" dia |
117 | Supply and fixing of 300mm Exhaust fan louvers/shutters. |
118 | Supply of LT XLPE PVC aluminium Unarmoured cable 50 Sq.mm 4core 1100 volt. |
119 | Supply of LT XLPE PVC aluminium Unarmoured cable 150 Sq.mm 4core 1100 volt. |
120 | Supply and fixingof Ultra modern, compact Surface mounted4""x1"" LED Flat panel which provides soft-light and glare free symmetrical illuminationLEDs 34W LEDas approved by Engineer in charge complete in all respect.(Havells). Model-PLUTO PANAL (SURFACE) |
121 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
122 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe FRLSom earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
123 | Providing and fixing of lightning conductor finial, made of 25 mmdia 300 mm long, copper tube, having single prong at top, with 85mm dia 6 mm thick copper base plate including holes etc.complete as required. |
124 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/sweating and soldering etc as required. |
125 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
126 | Above 35 sq. mm and upto 95 sq. mm |
127 | Above 95 sq. mm and upto 185 sq. mm |
128 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
129 | 3½ X 50 sq. mm (35mm) |
130 | Supply and installation of 6 mtr galvanised Octagonal pole with base plate 220x220 12 top 70mm & bottom 130 mm made up of 3mm thik suitable for max wind speed upto 160 km/hr. |
131 | poles with single bracket |
132 | Supply & InstallationofNew generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source as approved by Engineer in charge complete in all respect.(Rate taken from Havells Price List w.e.f. 1st july 2017). Model-RUBY (CLEAR) - IP65 |
133 | Cat AA (seg.) |
134 | Supplying and laying of aluminium conductor PVCinsulatedarmoured,served sheathed cable1100 Volots grade at depth of 750 mm below ground lavelover a cushion of 75 mm . Thick sand around and protected with burnt bricks on sides and on top.On surface the cable run shall be fixed on M.s. clamp etc. of suitable size as or directed by the Engineer Incharge in all respects.The armouring of the cable shall be properly connected with the earth conductor by clamp etc.(havells.plaza) |
135 | 50 sq.mm.3½ core Cat.A |
136 | Supply and erection of factory fabricated and wired metal clad dust and vermin proof ploor mounting panel TPN switch board complete with following HRC type heavey duty TPN fuse awitches with fuses and instrument chamber etc. complete in all respects .The instrument chamber shall be saprate and shall comprise of flush type ammeter ,voltmeter selector switches for ammeter voltmeter instrument fuse current transformer etc. The board shall have suitable cappcity electrolytic aluminium bus bars as per IS:8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC /DMC supports with detchable side covers and shall be suitable for extension on the sides .the switches shall be complete with suitable with cable and boxes ,revers entry boxes in case of pedestal type cable socket compression glands and indicating lamp on incoming etc. Thejob includes the grounting of the board as per direction of Engineer Incharge .All out going switches of 100 Amp and avobe will be provide with ammeter current transformers and selector switches etc. and istrument fuses. The switch board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm cubical type switch board shall be of Cat A, B & B = II only(Incoming 200 Amp. MCCB 1 No, 4P, 36 KA) (Outgoing 63 Amp MCCB 20 Nos.,4P, 25 KA, 16A MCB 3 No, FP 32A MCB 5 No, DP) |
137 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
138 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
139 | White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
140 | Providing and fixing chlorinated polyvinyl choloride (CPVC) pipes.having tharama stability for hot & cold water supply including all CPVC plain & brassthreated fittings.this included joints of pipes & fitting with one step CPVC solvent cement trenching , refilling & testing of joints complete as per direction of Engineer in charge. |
141 | 110 MM |
142 | 100 mm |
143 | 75mm |
144 | Providing and fixing 600 x 455 mm. bevelled edge mirror of Saint Gobin or Modi float glass complete with 6 mm. thick hard board ground fix to wooden cleats with CP brass screws and washers etc. complete. |
145 | Providing and fixing terminal guard :Sand cast iron S&S as per IS - 3989 |
146 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : Sand cast iron S&S as per IS - 3989 |
147 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : |
148 | 100 mm dia |
149 | Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : |
150 | 100 mm dia |
151 | Providing and fixing G.I. pipes complete with G.I. fittings andclamps, including cutting and making good the walls etc. Iinternal work - Exposed on wall |
152 | 15mm dia nominalbore |
153 | 25 mm dia. nominal bore |
154 | 50 mm dia. nominal bore |
155 | Providing and fixing ball valve (brass) of approved quality complete High or low pressure with plastic floats |
156 | 25 mm dia. nominal bore |
157 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : |
158 | 25 mm nominal bore |
159 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
160 | 15mm nominal bore |
161 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
162 | Providing & Fixing C.P. brass bib cock parryware make |
163 | Providing & Fixing C.P. brass Long boddybib cock |
164 | Providing & Fixing C.P. brassstop(conceald) |
165 | Providing & Fixing C.P. brassangle valve |
166 | Providing & fixing c.p. soap dish parryware make |
167 | Provding & Fixing C.P Towel rail parryware make |
168 | Provisiding & Fixing C.P Paper Holder parryware Make |
169 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 80 mm dia nominal bore |
170 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 455x610 mm and 45 cm deep for single pipe line : |
171 | Providing and laying non-pressure NP2 class (light duty RCC pipes with collars joints with stiff mixture of cement motor in the proportion of 1:2 (1 cement :2 fine sand ) including testing of joints etc.complets. |
172 | 100 mmdia rcc pipe |
173 | 30 mm dia rcc pipe |
174 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 60 cm dia, and 60 cm deep |
175 | Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment). |
176 | Fine dressing of the ground. |
177 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil |
178 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)Trees Plant |
179 | Supply and stacking of plant Calliandra hybrida of height 105-120 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge. |
180 | providing and fixing of central guide width 125 mm dia ms pipe c class with lentor mild channel gaurter |
181 | providing and fixing ms gas holder in bio gas plant as per direction of EI including its planting and fixing |
182 | initial feeding of plant with cow dung |
183 | supply and fixing of ms gobar mixing unit |
184 | providing and fixing ms jali |
185 | providing and fixing syphon botal unt |
186 | water remover system chember ms plete |
187 | 100% bio gas engine 10 kw capicity genset |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail