Tender For Construction Of Urban P.S. (Including Barrack And Canteen) Building At Bishnupur, Bankura - Balance Work. (2Nd Call)
Tender Value
1.88 Crore
Estimated cost
Bid Submission
30 Jan 2023
0 days left
EMD
3.76 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Urban P.S. (Including Barrack And Canteen) Building At Bishnupur, Bankura - Balance Work. (2Nd Call)
BOQ
| Sl. No. | Item Description |
| 1 | Civil works |
| 2 | Earth work in excavation of foundation trenches of drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing spreading or stacking the spoils with in a lead of 75m. As directed. The item includes necessary trim-ming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete. (a)Depth of excavation not execeeding 1,500 mm |
| 3 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation. |
| 4 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consoliding the same by through saturation with water ramming complete including the cost of supply of sand (payment to be made on measurment of finished quantity) Flooring Base |
| 5 | Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consoliding the same by through saturation with water ramming complete including the cost of supply of sand (payment to be made on measurment of finished quantity) Flooring Base |
| 6 | Anti-termite treatment to the soil under floor with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight including drilling vertically 12mm. dia holes at the junction of floor and wall at 300mm. interval to reach the soil below using hand operatedpressure pump to squirt chemical emulsion into the pump to squirt chemical emulsion into the holes at the rate of one litre per hole. The holes shall be sealed after operation to match with the existing floor. The entire work is to be carried out as per specification laid down in para 4.3.1.4 of code I.S.-6313 (Part-III)- 1981. |
| 7 | Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level, and filling joints with powered or local sand. |
| 8 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.a) Pakur Variety |
| 9 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevantspecial publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture](b) M 25 Grade a) Pakur Variety (A) AT GROUND FLOOR |
| 10 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevantspecial publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture](b) M 25 Grade a) Pakur Variety (A) AT FIRST FLOOR |
| 11 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevantspecial publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture](b) M 25 Grade a) Pakur Variety (A) AT SECOND FLOOR |
| 12 | Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF (c) Steel Shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work(A) AT GROUND FLOOR |
| 13 | Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF (c) Steel Shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work(A) AT FIRST FLOOR |
| 14 | Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF (c) Steel Shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work(A) AT SECOND FLOOR |
| 15 | Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction.(a) For works in foundation, basement and upto roof of ground floor/upto 4 m(i) Tor steel/Mild SteelI. SAIL/ TATA/RINL(A) AT GROUND FLOOR |
| 16 | Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction.(i) Tor steel/Mild SteelI. SAIL/ TATA/RINL(A) AT FIRST FLOOR |
| 17 | Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction.(i) Tor steel/Mild SteelI. SAIL/ TATA/RINL(A) AT SECOND FLOOR |
| 18 | Brick work with 1st class bricks in cement mortar (1:4) in (a) In foundation and plinth |
| 19 | Brick work with 1st class bricks in cement mortar (1:4) in Super Structure ,Ground Floor |
| 20 | Brick work with 1st class bricks in cement mortar (1:4) in Super Structure , First Floor |
| 21 | Brick work with 1st class bricks in cement mortar (1:4) in Super Structure , Second Floor |
| 22 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in Ground Floor |
| 23 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in First Floor |
| 24 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in Second Floor |
| 25 | Brick work with 1st class bricks in cement mortar (1:6) in (a) In foundation and plinth |
| 26 | Brick work with 1st class bricks in cement mortar (1:6) in (b) In superstructure, ground floor |
| 27 | Applying 2 coats of bonding agent with synthetic multifunctional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer\"s specification. For Water Proofing at roof |
| 28 | 25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer\"s specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item NO 60, polymer based paint as per item 59 (a) of Section (C). |
| 29 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. |
| 30 | 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m](A) AT GROUND FLOOR |
| 31 | 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m](A) AT FIRST FLOOR |
| 32 | 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m](A) AT SECOND FLOOR |
| 33 | Extra cost of labour for pre finish and pre moulded nosing to treads of steps,railing,window sil etc of kota stone. |
| 34 | Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) includingmaking suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture ofpigments matching the stone shadeincluding grinding and polishing all completeas per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m](A) AT GROUND FLOOR |
| 35 | Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) includingmaking suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture ofpigments matching the stone shadeincluding grinding and polishing all completeas per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m](A) AT FIRST FLOOR |
| 36 | Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) includingmaking suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture ofpigments matching the stone shadeincluding grinding and polishing all completeas per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m](A) AT SECOND FLOOR |
| 37 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Sand Cement Mortar (1:4)20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of each tile upto 0.09 Sq.m (i) Coloured decorative at FLOOR(A) AT GROUND FLOOR |
| 38 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Sand Cement Mortar (1:4)20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of each tile upto 0.09 Sq.m (i) Coloured decorative at FLOOR(B) AT FIRST FLOOR |
| 39 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. .(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of each tile upto 0.09 Sq.m (i) Coloured decorative at WALL(A) AT GROUND FLOOR |
| 40 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. .(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of each tile upto 0.09 Sq.m (i) Coloured decorative at WALL(A) AT FIRST FLOOR |
| 41 | Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble(dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m](A) AT GROUND FLOOR |
| 42 | Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material.[Border concrete if necessary to be paid separately].Note: Sub-grade CBR should not be less than 5.(c) 60 mm thick interlocking designer concrete paver block M-35 grade for light-traffic zone,commercial & office complex,tourist resort as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular /granular sub-base course including cost of sand for sand bed but excluding cost of base, sub-base ourse & subgrade preparation.)Coloured Decorative |
| 43 | Supplying , fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approvedmake (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap.(Payment to be made on area of finished work).(i) In Roof:-a) With 0.50 mm thick sheet |
| 44 | M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(ii) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr(A) AT GROUND FLOOR |
| 45 | M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(ii) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr(A) AT FIRST FLOOR |
| 46 | M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(ii) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr(A) AT SECOND FLOOR |
| 47 | Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.(A) AT GROUND FLOOR |
| 48 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in-charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete.I) For structural members of specified sections weighing less than 22.5 Kg./m |
| 49 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost ofall labour and materials. |
| 50 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Malaysian Sal(A) AT GROUND FLOOR |
| 51 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Malaysian Sal(A) AT FIRST FLOOR |
| 52 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehydeas glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.(a) 35 mm thick shutters (single leaf)(B) AT FIRST FLOOR |
| 53 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehydeas glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.(a) 35 mm thick shutters (single leaf)(A) AT GROUND FLOOR |
| 54 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.(ii) 32 mm thick(A) AT GROUND FLOOR |
| 55 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.(ii) 32 mm thick(B) AT FIRST FLOOR |
| 56 | Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.(ii) 66mm x 90mm(A) AT GROUND FLOOR |
| 57 | Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.(ii) 66mm x 90mm(B) AT FIRST FLOOR |
| 58 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal / Round rod) (v) 125 mm grip x 12 mm dia rod. |
| 59 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately). 40mm X 6mm, 250mm Length |
| 60 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark 100mm X 50mm X 1.25mm |
| 61 | Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. 250mm long. |
| 62 | Door stopper.(Brass) |
| 63 | Anodised aluminium barrel / tower /socket bolt (full covered) of approved manufractured from extructed section conforming to I.S. 204/74 fitted with cadmium plated screws. 300 mm long X 10mm dia bolt. |
| 64 | Anodised aluminium barrel / tower /socket bolt (full covered) of approved manufractured from extructed section conforming to I.S. 204/74 fitted with cadmium plated screws. 200mm long x 10mm dia. bolt. |
| 65 | Labour for Chipping of concrete surface before taking up Plastering work. |
| 66 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.(ii) With 1:3 cement mortar ,b) 10 mm thick plaster. Ceiling Plaster(A) AT GROUND FLOOR |
| 67 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.(ii) With 1:3 cement mortar ,b) 10 mm thick plaster. Ceiling Plaster(B) AT FIRST FLOOR |
| 68 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.(ii) With 1:3 cement mortar ,b) 10 mm thick plaster. Ceiling Plaster(C) AT SECOND FLOOR |
| 69 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.With 1:4 cement mortar b) 15mm thick plaster INSIDE(A) AT GROUND FLOOR |
| 70 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.With 1:4 cement mortar b) 15mm thick plaster INSIDE(B) AT FIRST FLOOR |
| 71 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.With 1:4 cement mortar b) 15mm thick plaster INSIDE(B) AT SECOND FLOOR |
| 72 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.With 1:6 cement mortar a) 20mm thick plasterOUTSIDE(A) AT GROUND FLOOR |
| 73 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.With 1:6 cement mortar a) 20mm thick plasterOUTSIDE(B) AT FIRST FLOOR |
| 74 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.With 1:6 cement mortar a) 20mm thick plasterOUTSIDE(C) AT SECOND FLOOR |
| 75 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.With 1:4 cement mortar a) 20mm thick plasterOUTSIDEGround Floor |
| 76 | Neat cement punning about 1.5mm thick in wall,dado,window sill,floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. |
| 77 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. ii) Solvent based interior grade Acrylic Primer,(b) Two Coats(A) AT GROUND FLOOR |
| 78 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. ii) Solvent based interior grade Acrylic Primer,(b) Two Coats(B) AT FIRST FLOOR |
| 79 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. ii) Solvent based interior grade Acrylic Primer,(b) Two Coats(C) AT SECOND FLOOR |
| 80 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC.[This item to be done under specific instruction of the Superintending Engineer](b) Two Coats(A) AT GROUND FLOOR |
| 81 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC.[This item to be done under specific instruction of the Superintending Engineer](b) Two Coats(A) AT FIRST FLOOR |
| 82 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC.[This item to be done under specific instruction of the Superintending Engineer](b) Two Coats(A) AT SECOND FLOOR |
| 83 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats)ii) Luxury Quality (Two coats)(A) AT GROUND FLOOR |
| 84 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats)ii) Luxury Quality (Two coats)(B) AT FIRST FLOOR |
| 85 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats)ii) Luxury Quality (Two coats)(C) AT SECOND FLOOR |
| 86 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. The items to be selected only with written permission of Superintending Engineer for very resticted and small areas of a building .b) Premium 100% Acrylic Emulsion(A) AT GROUND FLOOR |
| 87 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. The items to be selected only with written permission of Superintending Engineer for very resticted and small areas of a building .b) Premium 100% Acrylic Emulsion(B) AT FIRSTFLOOR |
| 88 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. The items to be selected only with written permission of Superintending Engineer for very resticted and small areas of a building .b) Premium 100% Acrylic Emulsion(B) AT SECOND FLOOR |
| 89 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.c) Super Protective 100% Acrylic Emulsion.In Ground floor (Two Coat) |
| 90 | Priming one coaton steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.(A) AT GROUND FLOOR |
| 91 | Priming one coaton steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.(B) AT FIRST FLOOR |
| 92 | Priming one coaton steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.(B) AT SECOND FLOOR |
| 93 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary .On Steel and otherMetal Surface .Two coatwith any shade except white.With super gloss (hi-gloss) -(A) AT GROUND FLOOR |
| 94 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary .On Steel and otherMetal Surface .Two coatwith any shade except white.With super gloss (hi-gloss) -(B) AT FIRST FLOOR |
| 95 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary .On Steel and otherMetal Surface .Two coatwith any shade except white.With super gloss (hi-gloss) -(C) AT SECOND FLOOR |
| 96 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.(A) AT GROUND FLOOR |
| 97 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.(B) AT FIRST FLOOR |
| 98 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface.With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)(A) AT GROUND FLOOR |
| 99 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface.With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)(B) AT FIRST FLOOR |
| 100 | Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall)ii) 4 mm thick |
| 101 | Extra for fixing glass panes in steel window |
| 102 | Supplying maruti lock (100 mm) |
| 103 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.In Ground floorFlash butt welded windows and ventilators(No shop priming will be allowed to facilitate inspection ofworkmanship)Without integrated grills.(a) Fixed type steel windows as per IS sizes with horizontal glazing bars.(A) AT GROUND FLOOR |
| 104 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.In Ground floorFlash butt welded windows and ventilators(No shop priming will be allowed to facilitate inspection ofworkmanship)Without integrated grills.(a) Fixed type steel windows as per IS sizes with horizontal glazing bars.(B) AT FIRST FLOOR |
| 105 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.In Ground floorFlash butt welded windows and ventilators(No shop priming will be allowed to facilitate inspection of workmanship)Without integrated grills.(b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only](A) AT GROUND FLOOR |
| 106 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.In Ground floorFlash butt welded windows and ventilators(No shop priming will be allowed to facilitate inspection of workmanship)Without integrated grills.(b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only](B) AT FIRST FLOOR |
| 107 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codesa) Pakur Variety |
| 108 | Sanitary & Plumbing WorkSupplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)40 mm |
| 109 | Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)32 mm |
| 110 | Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)25 mm |
| 111 | Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Concealed work15 mm |
| 112 | Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Concealed work20 mm |
| 113 | Supplying, fitting and fixing Peet\"s valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).40 mm dia |
| 114 | Supplying, fitting and fixing Peet\"s valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).32 mm dia |
| 115 | Supplying, fitting and fixing Peet\"s valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).25 mm dia |
| 116 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(A) (i) Single Socketed 3 Mtr. Length75 mm |
| 117 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(B) Fittings(i) Coupler(a) 75 mm |
| 118 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(B) Fittings(ii) Door Tee(a) 75 mm |
| 119 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(B) Fittings(iii) Door Y (LH) & (RH).(a) 75 mm |
| 120 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(B) Fittings(iv) Door Bend T.S(a) 75 mm |
| 121 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(B) Fittings(v) Plain Tee(a) 75 mm |
| 122 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(B) Fittings(vi)Bend 45 Degree(a) 75 mm |
| 123 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(B) Fittings(vii) Pipe Clip |
| 124 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(B) Fittings(vii)Vent Cowl75 mm |
| 125 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(A) (i) Single Socketed 3 Mtr. Length110 mm |
| 126 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(B) Fittings(i) Coupler(b) 110 mm |
| 127 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(B) Fittings(ii) Door Tee(b) 110 mm |
| 128 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(B) Fittings(iii) Door Y (LH) & (RH).(b) 110 mm |
| 129 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(B) Fittings(iv) Door Bend T.S(b) 110 mm |
| 130 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(B) Fittings(v) Plain Tee(b) 110 mm |
| 131 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(B) Fittings(vi)Bend 45 Degree(b) 110 mm |
| 132 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(B) Fittings(vii) Pipe Clip |
| 133 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(B) Fittings(vii)Vent Cowl110 mm |
| 134 | Labour for fitting and fixing U.P.V.C piupes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials)(A) Above ground(i) 75 mm |
| 135 | Labour for fitting and fixing U.P.V.C piupes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials)(A) Above ground(ii) 110 mm |
| 136 | Labour for fitting and fixing U.P.V.C piupes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials)(A) Below ground(i) 110 mm |
| 137 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. 635 mm X 395 mm X 420 mm |
| 138 | Supplying, fitting and fixing porcelain partition wall of approved make of size 618 mm X 310 mm complete in all respect. |
| 139 | Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc. Hindware/Parryware/Cera, made (a) With \"S\" trap (with vent) |
| 140 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.White |
| 141 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P.hinges, rubber buffer and brass screws complete.(b) Anglo Indian (ii) Plastic (hallow type) white |
| 142 | Supplying, fitting and fixing approved brand 32 mm dia. P.V.C. waste pipe, with coupling at one end fitted with necessary clamps. 1050 mm long |
| 143 | Supplying, fitting and fixing white vitreous china best quality approved makewash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 32 mm dia., approved qualityP.V.C. waste pipe with C.P. nut32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.(iii) 630 mm X 450 mm size |
| 144 | Supplying, fitting and fixing pedestal of approved make for wash basin (white) |
| 145 | Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (ii) 630 mm X 550 mm X 180 mm |
| 146 | Supplying, fitting and fixing pillar cock of approved make.a) (ii) CP Pillar Cock Super Deluxe with Aerator - 15 mm. (Equivalent to Code No. 508 & Model No. Tropical / Sumthing Special of ESSCO or similar brand). |
| 147 | Supplying, fitting and fixing towel rail with two brackets. (a) (ii)C.P. over brass (iii) 25 mm dia. and 750 mm long |
| 148 | Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm |
| 149 | Chromium plated Bib Cock (angular shape with wall flange) (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar brand). |
| 150 | Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand). |
| 151 | Chromium plated Hand shower with Flexible Tube & fittings(Equivalent to Code No. Hsh-1937 & (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar).). |
| 152 | Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 153 | Supplying, fitting and fixing 15 mm swan neck tap with left & right hand operating nob with aerator (Equivalent to Code No. 510, 510(A) and Model - TROPICAL / SUMTHING SPECIAL of ESSCO or similar brand). |
| 154 | Supplying, fitting and fixing C.I. round grating. (ii)150 mm |
| 155 | Supplying, fitting and fixing C.I. square jalli. (ii)150 mm |
| 156 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (f) 2000 litre capacity |
| 157 | Labour for hoisting plastic water storage tank. (f) 2000 litre capacity |
| 158 | Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chipsover a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety.(SAIL/TATA/RINL) |
| 159 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials.A) With Pakur variety (SAIL/TATA/RINL)(iii) For 100 users |
| 160 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) toinside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slabincluding filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. .With 250 mm thick dry brick work and 250 mm thick cement brick work (6:1) and 1.00m inside dia(SAIL/TATA/RINL)With Pakur variety |
| 161 | SINKING OF DEEP TUBE WELLLabour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (e) For depth upto 150 metre for 80 mm dia. tube well with top enlargement of 150 mm dia.(i)150 mm dia. boring etc. for top enlargement (A)-(V) Tube well item no - 1e(ii) |
| 162 | Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (e) For depth upto 150 metre for 80 mm dia. tube well with top enlargement of 150 mm dia.(ii) 80 mm dia. boring etc. for bottom enlargement of the well(A)-(V) Tube well item no - 1e(i) |
| 163 | Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with \"V\" notch including hire and labour charges for all tools and plants and scaffolding as required.(A)-(V) Tube well item no - 20 |
| 164 | Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete. (A)-(V) Tube well item no - 22 |
| 165 | Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-in-charge including cost of all materials labour and equipment complete. Note: Initial 6 m. of Annular space between the housing pipe and the bore should not be shrouded with Pea size gravel to avoid contamination with surface water.(A)-(V) Tube well item no - 24 |
| 166 | Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete.(A)-(V) Tube well item no - 25 |
| 167 | Collecting sample of water for bacteriological test & chemical test from any depth at any time during execution of work including hire & labour charge for tools & plants & sterilising the equipments, paying all charges & fees, testing etc. complete in all respect as per direction.(A)-(V) Tube well item no - 23 |
| 168 | d) Holding clamp for 150 mm dia tube well casing faricated by50mm x 6mm MS flat with necessary nuts, bolts & washers & painting |
| 169 | Supply & fixing 50 mm dia Gun metal Non-Return valve(ISI) (A)-(II) G.I. pipe & fittings item no -4 |
| 170 | Supply & fixing 50 mm dia G.I.Peets Valve(ISI)(Tested 21 kg per cm)(A)-(II) G.I. pipe & fittings item no -4 |
| 171 | Supply & fixing 100 mm x 65 mm dia G.I. Reducing Tee (For header) (A)-(II) G.I. pipe & fittings item no -(M) |
| 172 | Supply & fixing 100mm dia G.I. nipple short piece 150mm long(A)-(II) G.I. pipe & fittings item no -(F III) |
| 173 | Supply & fixing 100mm dia G.I. plug (A)-(II) G.I. pipe & fittings item no -(K) |
| 174 | Supply & fixing 65 mm x 50 mm dia G.I. Reducing socket (For delivery Line from header) (A)-(II) G.I. pipe & fittings item no -(L) |
| 175 | Supply & fixing 50 mm dia G.I. Union(A)-(II) G.I. pipe & fittings item no -(I) |
| 176 | Supply & fixing 50 mm dia G.I. Flange (A)-(II) G.I. pipe & fittings item no -(G) |
| 177 | Making holes on wall & mending good the damages to original finish |
| 178 | Construction of 200mm x 200mm x 900mm high brick pillars with cement plastering for supporting the G.I. pipe from tube well to header |
| 179 | Supply & fixing holding clamp fabricated by 50mm x 6mm with necy. Nuts, bolts & washers for holding the the column pipe. |
| 180 | Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty)conforming to ASTMD 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) 80 mm |
| 181 | Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty)conforming to ASTMD 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) 150 mm |
| 182 | Supplying 80 mm dia. PVC strainer of approved make with adapter conforming toI.S.12818 specifications. |
| 183 | Labour charge for Testing & Loweringthe submersible Pump motor set with submersible cable along with the column pipes into the tube wellafter socketing the column pipes step by step including arrangement of tripod, chain pully & tools & Tackles& providing suitable manpower to satisfactory operation. |
| 184 | Electrical Schedule ItemsSupply & Fixing 415V 63 A TPN (LT) switch in suitable SS enclosure with HRC fuses on LS & NL on angle iron frame on wall incl. earthing attachment.( barrack) |
| 185 | Supply & Fixing 415V 32 A TPN (LT) switch in suitable SS enclosure with HRC fuses on LS & NL on angle iron frame on wall incl. earthing attachment.( PUMP & barrack) |
| 186 | Supply & fixing 240 volt 32A DP switch with fuse on LS &in S.S. enclosure to be fixed on angle frame on wall incl. Earthing attachment.(Havells/)(canteen) |
| 187 | Supply & fixing of 240V 32A DP MCB (Legrand/Siemens) in DP SS enclosure (Legrand/Siemens) incl earthing attachment. ( FOR ROOF LIGHTING & canteen) |
| 188 | Supply & fixing 4 way double door horizontal TPN MCB DB with SS enclosure (Legrand) concealed in wall after cutting the wall & mending good the damages to original finish with earthing attachment comprising with the following. a) 63 A Four Pole isolator -1 No.b)16 to 32 A range SP MCB.- 12Nos. |
| 189 | Supply & fixing SPN MCB DB (2+8) WAY (Make Siemens/Legrand/As Per EIC) with S.S. Enclosure concealed in wall after cutting wall & mending good the damages & earthing attachment comprising with the following: a) 40 A DP isolator - 1 No.b) 6 to 16 A range SPMCB - 8 Nos.(SOR, PWD, ELECTRICAL.2017; PAGE-D10, ITEM-13;PAGE-D5,ITEM-6;PAGE-D6,ITEM-7 ) |
| 190 | Supply & fixing SPN MCB DB (2+6) WAY (MakeSchneider) with S.S. Enclosure concealed in wall after cutting wall & mending good the damages & earthing attachment comprising with the following: a) 40 A DP isolator - 1 No.b) 6 to 16 A range SPMCB - 6 Nos. |
| 191 | Laying of the following Alu. armoured cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammeda)4x 16 sq mm ( ps to barrack & VTPNto TPN DB) |
| 192 | Laying of the following Alu. armoured cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammedb) 2 x 6 sq mm (ps to canteen) |
| 193 | Laying of the following Alu. armoured cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammedc) 4 x 50 sq mm( meter looping) |
| 194 | Laying of the following XLPE Al armoured cable aftercutting floor /npavement / wall and making holes incl, embedding tha cable at an average depth as below& mending good the damages to original finish:-a)4x 16 sq mm |
| 195 | Laying of the following XLPE Al armoured cable aftercutting floor /npavement / wall and making holes incl, embedding tha cable at an average depth as below& mending good the damages to original finish:-c) 2 x 6 sq mm |
| 196 | Laying of the following XLPE Al armoured cable aftercutting floor /npavement / wall and making holes incl, embedding tha cable at an average depth as below& mending good the damages to original finish:-c) 4 x 50 sq mm( meter looping) |
| 197 | Supply & laying medium gauge G.I.Pipe(ISI-Medium) for cable protection a) 65 mm dia |
| 198 | Supply & laying medium gauge G.I.Pipe(ISI-Medium) for cable protection b) 40 mm dia |
| 199 | Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable:a)4x 16 sq mm |
| 200 | Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable:b) 2 x 6 sq mm |
| 201 | Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable:c) 4 x 50 sq mm( meter looping) |
| 202 | Supply & drawing of 1.1 Kv grade single core stranded \"FR\" Pvc insulated & unsheathed copper wire (brand appr by EIC) of the following sizes through alkathene pipe recessed in wall. b)2x4+1x2.5 sq mm though 25mm Alka Pipe(SPNDB & AC ) |
| 203 | Supply & drawing of 1.1 Kv grade single core stranded \"FR\" Pvc insulated & unsheathed copper wire (brand appr by EIC) of the following sizes through alkathene pipe recessed in wall. c) 2x2.5+1x1.5 sqmm through 19mm Alka.pipe ( P/P) |
| 204 | Supply & drawing of 1.1 Kv grade single core stranded \"FR\" Pvc insulated & unsheathed copper wire (brand appr by EIC) of the following sizes through alkathene pipe recessed in wall. d) 3x1.5 sq mm through 19mm Alkathene pipe |
| 205 | Distn. wiring in 3 x 1.5 sqmm single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Gloster/Finolex/Havells) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/ fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish (Avg 9 mtr) |
| 206 | Distribution wiring in 1.1 KV grade 3 x 1.5 sq mm single core stranded \"FR\" PVC insulated & unsheathed copper wire (brand approved by EIC) in 19mm bore, 3mm thickpolythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240V 6A 3 pinmodular type plug socket & modular type switch(Brand appr. by EIC) incl. S&F earth continuity wire fixed on 4 moduleGI switch board with 3/4 module top cover plate flushed in wall incl mending good damage to original finish. (on board) |
| 207 | Distribution wiring in 1.1 KV grade 3 x 1.5 sq mm single core stranded \"FR\" PVC insulated & unsheathed copper wire (brand approved by EIC) in 19mm bore, 3mm thickpolythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240V 6A 3 pinmodular type plug socket & modular type switch(Brand appr. by EIC) incl. S&F earth continuity wire fixed on 4 moduleGI switch board with 3/4 module top cover plate flushed in wall incl mending good damage to original finish. (Ave run 4.5 mtr) |
| 208 | Supply & fixing of Modular type 16A3 pin modular type plug socket (Brand approved by EIC) with 16 A Modular type switchwithoutplug top on of 4 module GI box with cover plate recessed in wall comprising of the following (All cabtree): a) 16A switch---1 set b)16A socket- -1 set |
| 209 | Fixing only singal / twin fluorescent light complete with all accessories directly on wall/ceilinh/HW round block and suitable size of MS fastener,ceiling plate, nipples etc. as required |
| 210 | Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering tha box |
| 211 | Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long)9\" Exhaust fan(23cm) |
| 212 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:9\" Exhaust fan(23cm) |
| 213 | Supply & Fixing electronics step type, Moduler Socket type (2 module), Fan regulator (Cabtree) |
| 214 | Earthing the the Installation by 50 mm dia G.I. Pipe (ISI -M) 3.64 mtr long & 1x4 SWG G.I.(Hot dip) wire (4 mtrlong) with suitable nuts, bolts & washer etc. Incl S/F 15 mm dia GI protection pipe (1 mtr long) to be filled with bitumen partly under ground level & partly under ground level driven to an depth of 3.65 mtr below the ground level. |
| 215 | S & F earth busbar of galvanized (Hot Dip) MS flat 25mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required |
| 216 | S&F GI waterproof type looping cable box size 200x15x100 mm deep having 4 mm thick comprising of one 250 v 15 A kit-kat fuse unit, one NL on procelain insulator. One compression type brass cable gland for upto 2 core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machane screws etc. earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick. MS claps with bolts, nuts etc. including painting with anticorrosive paint |
| 217 | Fixing only outdoor / street light typelight fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting |
| 218 | Electrical Schedule ItemsSupply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Gloster/Nicco/Havells / Mescab) a)4x 16 sq mm |
| 219 | Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Gloster/Nicco/Havells / Mescab) b) 2 x 6 sq mm |
| 220 | Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Gloster/Nicco/Havells / Mescab) c) 4 x 50 sq mm( meter looping) |
| 221 | Supply & fixing ofCeiling Fan (Orient,New Bridge) complete with all acessaries Incl S/F necy copper flex wire.a) 1200mm sweep |
| 222 | Supplythe following Heavy duty Exhaust Fan without louvreshutter (make- Heavels/Orient)a) 9\" Exhaust fan(23cm) |
| 223 | Supplythe following Heavy duty Exhaust Fan without louvreshutter (make- Heavels/Orient)b) 300 mm (12\") sweep exhaust fan |
| 224 | Supply & fixing Angular batten holder (Anchor) onround block on wall/ceiling incl. S/F 5w LEDLamp (Philips) |
| 225 | Supply & fixing Bulk Head light fitting withLED lampmake cromptoncat no-LBHE-10-CDL |
| 226 | Supply of4\" 20W singleEssential LED Tube light fittings with mounting rail(make CromptonCat.No -IGP 131 LT8-16, 1X20w LT8-20-865-2-20W) . |
| 227 | Supply & fixing72 w LEDfitting (Make Ceompton, Cat no. LSTP-72-CDL72 ) |
| 228 | Supply & fixing45 w LEDfitting (Make Ceompton, Cat no. LSFO-45-CDL45 ) |
| 229 | Supply & fixing 5kgcapacity ABC stored pressure type fire extinguisher with discharge hose & nizzle on wall with suitable iron bracket including all accessories of approved make. |
| 230 | SUPPLY & INSTALLATION OF SILENT D.G. SET Supply & delivery of 415V (3-Ph) 20 KVA Silent Deisel Generator Set complete with all accessaries (Make JAKSON GREEN ) |
| 231 | Installation, testing & commissioning of the above D.G. set to satisfactory operation ( incl. Fuel) |
| 232 | Supply & fixing100 w square shaped LEDfitting (Make Legero-LAS-0100/Crompton/As Per EIC) |
AI Tender Summary
Tender Timeline
Jan 06, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedJan 30, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 02, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender