Housing Urban and Rular Development Government Departments Closing in 0 days TDR #35626723

Tender For Providing Ei At 10 Bedded Damcherra Phc Building At Damcherra, Kanchanpur, North Tripura. Main Building Coneal Wiring

Issued by Government Departments · damcherra, Tripura
Tender Value
9.37 Lakhs
Estimated cost
Bid Submission
25 Jan 2023
0 days left
EMD
18741
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
damcherra → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Providing Ei At 10 Bedded Damcherra Phc Building At Damcherra, Kanchanpur, North Tripura. Main Building Coneal Wiring

BOQ

Name of Work: Proposed construction of 10(Ten) beded Primary Health Centre ( PHC) including 10 (Ten) Nos staff quarter ( Type-1 qtr-4 unit ( one block twin double storey) Type-2 qtr- 4 unit ( one block twin double storey) and Type-3 qtr 2 unit ( one block twin) morgue Garage & Generator with Driver room and boundary wallat existing Damcherra PHC under Kanchanpur Division, North Tripura under NHM / SH: Building Portion including water supply, sanitation installation sewage and drainage works. / SH: Providing conceal E.I for PHC building only.
Sl. No. Item Description
1Wiring for light/ fan/ exhaust fan/ call bell point with 2x1.5 sq. mm PVC insulated copper conductor cable (FR) in PVC conduit (medium gauge) recessed in slab/ wall complete with 6/10 amps modular type switch, cover plate, GI box including necessary connection etc. as required.(As per TSR 2021,sl no.401)
2Wiring for Circuit/Sub-main wiring with the following sizes of PVC insulated copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- (As per TSR 2021,sl no.503)
31 x 1.5 sq mm
42 x 2.5 sq mm
52 X1.5 sqmm
62 x 2.5 sq mm
72 x 4 sq mm
84 x 10 sq mm
94 x 16 sq mm
10Providingearthing systemwith maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminalsize 32mmx 6mm including accessories with masonry enclosure of CIcover plate size 12\"x 12\" having locking arrangement including CC works etc as required:-(As per TSR 2021,sl no.717)
11Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copper wire on surface or inexisting G.I / PVC / Polythene pipe for loop earthing as required. [TSR (IE)2021 SL.No.707]
12Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of4.06mm (8SWG) dia G.I./ Copper wire forearth connection from earth electrodes etc as required.(As per TSR 2021,sl no.710)
13Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required.:- (As per TSR 2021,sl no.607)
146 module GI switch board
1512 module GI switch board
16Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required:-(As per TSR 2021,sl no.608)
176 module
1812 module
19Supplying and fixing of the following modular accessories including necessary connection etc. as required.(As per TSR 2021,sl no.609)
206/10 amps one way SP switch (1M).
213 pin 6/10 amps socket outlet (2M).
2216/20 amps one way SP switch (1M).
233/6 pin 16/20 amps socket outlet (2M).
24Blank Plate (1M)
254 Step Fan Regulator (1M)
26Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-(TSR-2021, SL-1202)
2763 amps TPN 415 voltsfront handle cubical main switch (HRC):-
28Supplying and installation of change over switch of following ratings with enclosure including necessary connection etc. as required:-(TSR-2021, SL-1204)
2932 amps FP on load change over switch (Front handle with enclosure)
30Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required:-(TSR-2021, SL-1208)
312 +4/ 6 way SPN MCB DB (double door):-
326way horizontal TPN MCB DB (double door):-
338way horizontal TPN MCB DB (double door):-
344 way vertical TPN MCB DB suitable for FP MCCB incomer upto 125 Amps (Double Door).
35Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connectionas required:-(TSR-2021, SL-1215)
366 to 32 amps SP MCB:-
376 to 32 amps DP MCB:-
3840/50/63 amps FP MCB.
3940/50/63 amps TP MCB.
40Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):-(TSR-2021, SL-1219)
4116 to 100 ampsTP MCCB, Breakingcapacity 16/18KA (Thermal Magnetic):-
42Supplying & fixing of 1200 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR)(ISI marked, BEE 1star/minimum service value 4.0 m3/min/W) : -(TSR-2021, SL-802)
43Supplying & installation of 400 mm sweep AC wall padestal fan with plastic blade including connection etc as required:-(As per TSR 2021,sl no-808)
44Supplying & installation of 300 mm sweep 900 rpm metalic body exhaust fan including connection etc as required (ISI marked):-(As per TSR 2021, sl no-818)
45Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:-(As per TSR 2021,sl no.821)
46Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required.:-(As per TSR 2021,sl no-831)
47Supplying and fixing of following luminaries complete withnecessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):-(TSR-2021, SL-1001)
48Box type single FTL fittings of CRCA steel sheet housing complete with 36/40 W FTL,electronic ballast and high quality reflector cover : -
49Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-(As per TSR 2021,sl no.1103)
509 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :-
51Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc.as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-(As per TSR 2021,sl no-1101)
52Recessed round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser
53Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-(As per TSR 2021,sl no.1102)
5445 watt LED street light fixture with integral driver and secondary lens (IP 66):-
55Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:-(As per TSR 2021, sl no-1501)
5640 mm dia
57Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering,shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size):-(TSR-2021, SL-1519)
58Centering shuttering including struttings, propping etc. and removal of form work for: Foundations, footings, bases for columns etc. for mass concrete with timber plank:-(TSR-2021, SL-1520)
596 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete. In cement mortar 1 : 4 ( 1 cement : 4 fine sand ):-(TSR-2021, SL-1521)
60Supplying & installation of Digital timer Switch including necessary connection etc as required:-(As per TSR 2021,sl no.1512)
61Supplying & installation of following power contactors including necessary connection etc as required:-(As per TSR 2021, sl no.1514)
623 pole 18 amps (AC3)power contactors with 1NO+1NC Aux. Contact.
63Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required[TSR (IE)2021, SL.No.1301]
643 core 4 Sq mm
654 core 25 Sq mm
66Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : -(As per TSR 2021,sl no.1405)
671.5 sqmm - 4 sqmm Cable:-
68Supplyingandfixingoffollowing alluminum terminal ends:-(As per TSR 2021,sl no.1401)
6925 sq mm
70Drawing of armoured/un-armoured cable with proper saddeling etc as required:- (As per TSR 2021,sl no-1511)
71Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 noslegs (25mmx25mmx5mm MS angle20 cm long) finishedwith red oxide and 2 coat synthetic enamel paintincluding necessary cc work, mending the damages & painting etc as required:-(TSR-2021, SL-1502)
72Supplying and fixing of the following PVC conduit (medium gauge) with all accessories on slab/ recessed on wall etc as required:-(As per TSR 2021,sl no-603)
7319/20 mm dia
7425 mm dia
75Supply and fixing of 25mm x 5mm GI strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals.(As per TSR 2021,sl no.712)
76Supply and fixing of the following sizes GIprongwith necessary nuts & bolts etc as required grouted on roof for Lightning protection.(As per TSR 2021,sl no.716)
77G.I Prong 450 mm long
78Supplying & installation of Surge Protection Device (SPD) of following ratings in the existing Panels/MCB DBs including necessay connections etc as required:-(As per TSR 2021,sl no.1216)
79Surge Protection Device (SPD, withdrawable) (Type-2) with Imax 15 KA (3P+N) :-

AI Tender Summary

OUR REF NO 35626723
AUTHORITY Government Departments
TENDER VALUE 9.37 Lakhs
LAST DATE 25-01-2023
Authority
Authority Name Public Works Department
Work Description Providing Ei At 10 Bedded Damcherra Phc Building At Damcherra, Kanchanpur, North Tripura. Main Building Coneal Wiring
Basic Detail
Tender No 59/EE-IED/AMB/2022-23
Bidding Type Tender
Location
City damcherra
State Tripura
Key Dates
Publish Date 06 Jan 2023
Submission Date 25 Jan 2023
Open Date 27 Jan 2023
Finance
Tender Value 9.37 Lakhs
Tender Fee 1000
EMD 18741
Exemption Not Available
Document List
bb3935ff-9b98-4d71-ba06-d2a38efd44e2.html
BOQ_36899.xls
DNIeT59.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 06, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 25, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 27, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

bb3935ff-9b98-4d71-ba06-d2a38efd44e2.html

xls

BOQ_36899.xls

pdf

DNIeT59.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender