Survey, Design And Construction Of Following Water Supply Scheme, Consisting Of Source Work, Supply Main, Rcc Cwrs, Distribution Systems, Fhtc And All Other Appurtenant Works Including Supply & Cartage Of All Materials, Labor And T&P Etc. Complete For Pro
Tender Overview
Project Description
Survey, Design And Construction Of Following Water Supply Scheme, Consisting Of Source Work, Supply Main, Rcc Cwrs, Distribution Systems, Fhtc And All Other Appurtenant Works Including Supply & Cartage Of All Materials, Labor And T&P Etc. Complete For Proper Completion Of Works. It Is Also Including Testing & Commissioning Ofscheme With Six Months Trial & Run After Handing Over The Scheme To Ujs For Its Maintenance.Devidhar Chirbatiya Solar Pumping W / S Scheme & Budhana W / S Scheme Of Block Jakholi,
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 07-Jan-2023 | Regarding Date Corrigendum | Other | 14-Jan-2023 |
| 2 | 10-Jan-2023 | Corrigndum | Other | 14-Jan-2023 |
BOQ
| Sl. No. | Item Description |
| 1 | SOURCE WORKS |
| 2 | Construction ofIntake chamber to fulfill therequierment of water demandincluding Supply of all materials, labour,carting of material T&P etc complete as per direction of Engineer in charge |
| 3 | Construction of RCC Gadhera tapping arrangement i.e., 4m wide Cross wall Boulder Filled Gallery with Intake chamberto fulfill therequierment of water demandincluding Supply of all materials, labour,carting of material T&P etc complete as per direction of Engineer in charge. |
| 4 | Construction of Extra length R.C.C Cross wallincluding supply of all materials, labour, T&P etc. required for proper completion of work |
| 5 | Constructionof Roughening Filter with filling of supporting & filter media including all materials, cartage labour, T&P etc. required for proper completion of work |
| 6 | Providing of all materials, Carting from site store to site of work,Lowering into trenches with true to alignment, Laying of MSERW, Jointingby electric welding process with proper grade ofeletrodes suitable for jointing of water supply pipe lines (Ador,L&T or equivalent electrodes) by cutting of pipes and making required bends by welding, completion of work with testing of pipe line etc complete. |
| 7 | From MPS to Top Cwr. MS ERWPipe 65 mm Dia 4 mm Thickness |
| 8 | Supply, carting , laying true to aligment and gradient, jointing and fixing of following GI (M) pipe lines including all specials fittings, white lead, hemp and other appurtenant works etc. making necessary connections with existing laid pipe line including connectingwith existing Private & Othe house hold Tap Connections with control plate/ferrule devices etc completeand make properfunctioning, confirming to IS:1239 at site of works. |
| 9 | 15 mm dia - GI (M) |
| 10 | 20 mm dia - GI (M) |
| 11 | 25 mm dia - GI (M) |
| 12 | 32 mm dia - GI (M) |
| 13 | 40 mm dia - GI (M) |
| 14 | 50 mm dia - GI (M) |
| 15 | 65 mm dia - GI (M) |
| 16 | Dismentling and relaying of following sizes of G.I. Pipes Medium quality confirming to IS:1239 at site of works including all labour T&P etc. complete for proper complition of work & also for making FHTC laid from existing newly laid pipe lines under scheme as per direction &instruction of given by Engineer -In-Charge. |
| 17 | 15mm dia |
| 18 | 20mm dia |
| 19 | 25mm dia |
| 20 | 32mm dia |
| 21 | 40mm dia |
| 22 | 50mm dia |
| 23 | 65mm dia |
| 24 | Excavation of earth for pipeline in following strata lift upto 1.5 m lead upto 30 m including refilling, watering, ramming of excavated earth into the trenches and removal of surplus earth upto a distance of 60 m from trenches including supply of labour, T & P etc.all complete assumingthat 90% pipe line is laid in trenches, it is estimated that 75% excavation will be in soilmixed with shingle, bajari and boulders and rest 25% will be in medium rock |
| 25 | Soil mixed with boulder (SMB) |
| 26 | Medium Rock (MR) |
| 27 | Supply and fixing of Wheel Valve/ Gate Valve of the following sizes including cartage of materials, labour, T&P etc. complete |
| 28 | 20 mm dia |
| 29 | 25 mm dia |
| 30 | 32mm dia |
| 31 | 40mm dia |
| 32 | 50mm dia |
| 33 | 65mm dia |
| 34 | Supply Cartage and fixing of Sluice Valve/Air Valve of the following sizes including cartage of materials, labour, T&P etc. complete |
| 35 | 20 mm dia |
| 36 | 50mm dia (CI Air Valve) |
| 37 | ConstructingWheel Valve Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse) including supply, cartage of all material, labour, T&P etc complete for Sluice Valve/Air Valve with C.I. surface box 100 mm. as per standard design. with locking arrangement. |
| 38 | Supply of all materials, labour, T & P etc. and Construction of size Sluice Valve / Reflux Valve / Scour Valve Chamber as per type design complete(0.90x0.90x1.0) |
| 39 | Supply of all materials, labour, T & P etc. and Construction of size Air Valve Chamber as per type design complete(0.90x0.90x1.0) |
| 40 | ACTARIS Bulk Water Meters model Woltex Class B magnetically coupled pre equipped for remote reading |
| 41 | 65 mm dia |
| 42 | Supply of all materials, labour, T&P etc. and construction of (0.90x0.90x1.0)m size Bulk Water Meter Chamber with FPS bricks |
| 43 | Supply of all materials, labour, T & P etc. and Construction ofR.C.C Anchor Blockas per type design complete |
| 44 | Makig2 M wide Briddle path forrising main including hill side cutting and coolie walling of all materials, labour, T & P etc. |
| 45 | Painting of API Pipes with 2 coats of approved quality. (Anti-Corrosive paint over one coat of Primer) (Dia of pipe in mm) |
| 46 | 65 mm dia |
| 47 | Construction of following capacity RCC semi sunk reservoir, including testing and commissioning for water tightness, with supply of all materials Labour, T&P etc and construction of RCC CWR of following capacities (in kiloliters) with M.S. ladder outside & inside of the tank, M.S. M.H. Cover with locking arrangement, supply and fixing of outlet, inlet, over flow and wash out pipes with necessary sluice valves, pipe pieces (including cost of materials) flooring 0.60 M wide apron, painting on tank body vertical pipes, ladder, M.S. M.H. cover etc. complete with approved water proofing (apex)/enamel paint, testing, filling water for testing purpose etc. including supply of vertical pipes and specials, assuming bearing capacity as 8 MT/M2 |
| 48 | 7.50 KL |
| 49 | 20.00 KL |
| 50 | 22.50 KL |
| 51 | 40.00KL |
| 52 | 50.00KL |
| 53 | 60.00 KL |
| 54 | Supply cartage and fixing ofBucket type chlorinator of 25 Liter capacity at top of service raservoirs. |
| 55 | Supply of all materials, labours, T&P etc and construct og Break Pressure Tank |
| 56 | Supply, Cartage of all materials, labours, T&P, etc complete making of ferrule connection to provide FHTC to the consumers from existing/Newly laid pipe lines under scheme as per instruction given by Engineer-In-charge. |
| 57 | Concrete with 2 Cm gauge stone ballast, local sand and cement in proportion of 1:2:4 in foundation and floors including supply of all materials, labour and T&P etc.required for proper completion of work. |
| 58 | Concrete with 4 Cm gauge stone ballast, local sand and cement in proportion of 1:4:8 in foundation and floors including supply of all materials, labour and T&P etc.required for proper completion of work. |
| 59 | R.R. Stone masonary with 1:6 cement and sand mortar including cartage and supply of all materials,labours,T&P etc. complete for proper completion of work. |
| 60 | R.R.Stone masonry laid in dry including cartage and supply of all materials,labours,T&P etc. required for proper completion of work. |
| 61 | Provision of 1.5 m high Boundary Wall in brick masonry including supply of all materials, labour, T&P etc. complete |
| 62 | Provision of Barbed Wire Fencing through angle iron posts around the water works site |
| 63 | Provision of M.S. Iron Gate with Pillars of 3.6 m wide |
| 64 | Provision ofPannel Room 1.5 x1.5x2.0 sizes complete |
| 65 | Supply & installation of solar Submersible Pump, Control Panel, Solar Panels, wiring, automationincluding supply of all materials,labour, T&P etc complete as per latest specification and direction as per engineer in charge. |
| 66 | MPS to IPS Ist ( 150 LPM discharge and 171 m head) |
| 67 | IPS 1st to IPS IInd ( 150 LPM discharge and 186 m head) |
| 68 | IPS IInd to Top CWR ( 150 LPM discharge and 177 m head) |
| 69 | Solar panel 335 WP x 144 = 48240 watt with GI structure |
| 70 | Control Panel/VFD panel hybrid controller (solar+Grid) |
| 71 | Complete Wiring of all the above system |
| 72 | Earthing of above system |
| 73 | Installation of all the above system |
| 74 | Construction of of electrical Pole and Grouting etcincluding supply of all materials,labour, T&P etc. complete. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender