}

Bids Are Invited For 1 Supply Installation Testing And Commissioning Of Following Capacity Mono Block Pump Sets With Ci Impller Gland Packing Sealing C040 Shaft Ip-44 F Class Insulation, Complete With Suitable Size C Channel Frame Nut Bolts Etc.As Requ, Delhi-Delhi

Ministry Of Urban Development has published Bids Are Invited For 1 Supply Installation Testing And Commissioning Of Following Capacity Mono Block Pump Sets With Ci Impller Gland Packing Sealing C040 Shaft Ip-44 F Class Insulation, Complete With Suitable Size C Channel Frame Nut Bolts Etc.As Requ. Submission Date for this Tender is 16-01-2023. Uniform Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

35619914
Bids Are Invited For 1 Supply Installation Testing And Commissioning Of Following Capacity Mono Block Pump Sets With Ci Impller Gland Packing Sealing C040 Shaft Ip-44 F Class Insulation, Complete With Suitable Size C Channel Frame Nut Bolts Etc.As Requ
Open Tender
Indian
Delhi
Delhi
16-01-2023

Tender Details

Bids Are Invited For 1 Supply Installation Testing And Commissioning Of Following Capacity Mono Block Pump Sets With Ci Impller Gland Packing Sealing C040 Shaft Ip-44 F Class Insulation, Complete With Suitable Size C Channel Frame Nut Bolts Etc.As Required Rating 15 Hp 11 Kw Suc X Del 100 X100 Mm 2 Supply Installation Testing And Commissioning Of Following Capacity Mono Block Pump Sets With Ci Impller Gland Packing Sealing C-040 Shaft Ip-44 F Class Insulation, Complete With Suitable Size C Channel Frame Nut Bolts Etc As Required Rating 12.5 Hp 9.3 Kw Suc X Del. 100 X 100 Mm 3 Supply Installation Testing And Commissioning Of Following Capacity Mono Block Pump Sets With Ci Impller Gland Packing Sealing C 040 Shaft Ip-44 F Class Insulation, Complete With Suitable Size C Channel Frame Nut Bolts Etc.As Required Rating 20 Hp 15 Kw Suc X Del 125 X 125 Mm 4 Supply Installation Testing And Commissioning Of Following Capacity Waste Disposer Pump Set With Ci Impller Ci Body Del 50 Mm Etc Complete As Required 5 Supply Of Multicore Alumunium Conductor Xlpe Insulated Armoured Cable 1.1 Kv Grade Confirming To Is 7098 Part I Complete With All Amendments Etc As Required 4X25 Sq Mm 6 Supply Of Multicore Alumunium Conductor Xlpe Insulated Armoured Cable 1.1 Kv Grade Confirming To Is 7098 Part I Complete With All Amendments Etc As Required 4X50 Sq Mm 7 Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket Bend Couplers Etc Conforming To Is 14930 Part Il Complete With Fitting And Cutting Jointing Etc Direct In Ground 75 Cm Below Ground Level Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc Complete As Required 63 Mm Dia Od 63 Mm And Id 51Mm Nominal Dsr 2022 8 Supplying And Laying 6 Swg G.I. Wire At 0.50 Metre Below Ground Level For Conductor Earth Electrode Including Connection Termination With Gi Thimble Etc As Required Dsr 2022 9 Laying Of One Number Pvc Insuated And Pvc Sheathed Xlpe Power Cable Of 1.1 Kv Grade Offollowing Size In The Existing Rcc Or Hume Or Metal Pipe As Required Upto 35 Sq Mm Dsr 2022 10 Laying Of One Nmber Pvc Insulated And Pvc Sheathed Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonary Open Duct As Requied. Above 35 Sq Mm And Upto 95 Sq Mm Dsr 2022 11 Laying Of One Nmber Pvc Insulated And Pvc Sheathed Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required. Above 35 Sq Mm And Upto 95 Sq Mm. Clampped With 25X3mm Ms Flat Clamp Dsr 2022. 12 Supplying And Laying 2.5 Sq Mm X 3 Core Copper Conductor Round Flexible Cable 1100 Volt Conferming To Is 694 Connection Testing Etc As Required. 13 Supply And Installation Following Fully Automatic Star Delta Motor Starter Complete With Single Phase Preventer Connection Testing Etc. As Required 15 Hp Relay Range 9 To 14 14 Supply And Installation Following Fully Automatic Star Delta Motor Starter Complete With Single Phase Preventer Connection Testing Etc. As Required 20 Hp Relay Range 28 To 42 15 Supplying Laying Jointing And Positioning Of Following Size Ms C Class Pipe Complete With Suitable Size Fittings Such As Bend, Flandge Nutbolt Rubber Packing Connection Testing Welding Etc As Required 16 Supplying And Installation Of Following Cast Iron Accessories As Per Is14846 In The Existing Pipe Line Complete With Nut Bolt Rubber Packing Testing Etc As Required Non Rising Sluice Valve Pn 1.0 Size 100 Mm 17 Supplying And Installation Of Following Cast Iron Accessories As Per Is14846 In The Existing Pipe Line Complete With Nut Bolt Rubber Packing Testing Etc As Required Non Return Valve Pn 1.0 Size 100 Mm 18 Supplying And Installation Of Following Cast Iron Accessories As Per Is14846 In The Existing Pipe Line Complete With Nut Bolt Rubber Packing Testing Etc As Required Foot Valve Pn .02 Size 100 Mm 19 Supplying And Installation Of Following Cast Iron Accessories As Per Is14846 In The Existing Pipe Line Complete With Nut Bolt Rubber Packing Testing Etc As Required Df Stainer Size 100 Mm 20 Providing And Laying In Position Cement Concrete 1 2 4 1Cement 2 Coaese Sand 4 Gradedstone Aggegate 20 Mm Nominal Size In Foundation Of Pump Dg Set Etc Including Form Work Etc As Required. Dsr 2022 21 Supplying And Installation Manyfold Made Out Of 200 Mm Dia C Class Ms Pipe Complete With Connection Testing Etc As Required. 22 Supplying And Installation Mccb 100 Amp 4 Pole 30 Ka In Existing Feeder Pillar Complete With Copper Lugs, Thimble Connection Testing Etc As Required. 23 Supplying Anf Fixing Ms Pipe Size 40 Mm B Class Complete With Welding Work Priming Painting Etc As Required 24 Supply And Installation Of Led Flood Light Not More Than 200W Led And Not Lesser Than 24000 Lux Main Housing Made Of Pressure Die Casting With Uniform Thickness And Proper Heat Sink Design To Ensure Fast Heat Dissipation Led Should Be As Per Given Specification In Bid 25 Supply And Installation Of Led Flood Light Not More Than 70W Led Main Housing Made Of Pressure Die Casting With Uniform Thickness And Proper Heat Sink Design To Ensure Fast Heat Dissipation. The Led Should Be As Per Given Specification In Bids 26 Supplying And Installation Of Smc Connector Box Size 333X233x120 Mm With Four Nos. 6 Amp Sp Mcb Connector Suitable Size Clamp / Munting Arrangment Conection Testing Etc As Required 27 Supplying And Installation Ms Bracket Size 1200 Mm X 450Mm Made Out Of 50 Mm Ms Square Pipe 16 Swg Suitable To Accomodate 04 Nos Led Flood Lights Complete With Drilling Threading Welding Priming Painting Etc As Required. Total Quantity : 2263

Key Value

Document Fees
Refer document
EMD
INR 53342.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail