Military Engineer Services-MES has published Tender For Repair And Maintenance Of Summer Appliances Under Ge Saugor. Submission Date for this Tender is 03-02-2023. Air Conditioner Tenders in sagar Madhya Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 19-Jan-2023 | Revised BOQ | BOQ | 27-01-2023 |
2 | 27-Jan-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 03-02-2023 |
Sl. No. | Item Description |
1 | AIR CONDITIONER (SPLIT/WINDOW/WALK-IN-COOLER) |
2 | Carry out day to day complaintrectification and periodical service maintenance as per manual recommendation at Area I & Area IIlike testing of gas leakegefrom line any Capacity, replacement of defective any capacity of capacitor/Condensor,any size of Copper tube alongwith insulation pipe, drain out pipe, Cooling fan & cooling fan motor and cooling coil ,Compressor, air filter, Swing motor, over load relay, PVC grill, PCB circuit board along with remote control, Condensor motor & fan blade , industrial metal plugtop and bottom, Plug nut, Suction pipe, Charging Gas, Testing of gas leakeage using nitrazen gas, Cleaning of the Filters, checking control Wiring ,etc., complete allas directed by the Engineer-in-ChargeNote: (i) Replacement of Spares and fitting shall be measuredand paid separately as "Supply only" under Srl item No.1.02 to 1.84 .(ii)If required shifting of Split /Window AC shall be measured and paid separtely.(iii)Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv). AC Mechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day.(v)Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II . (vi)Attending the complaints not less than min three complaints per day (vii) Spare parts shall be measured and paid separately if their rate above Rs. 100/- |
3 | Compressor suitable for window/Split AC of capacity 1.5 Ton. Make:GODREJ/L&T/BLUE STAR/WHIRLPOOL/VOLTAS |
4 | Compressor suitable for window/Split AC of capacity 2.0 Ton.Make:GODREJ/L&T/BLUE STAR/WHIRLPOOL/VOLTAS |
5 | Compressor suitable forWalk incooler installed at MH saugor Medical store Hermaticallytype capacity of2.0 Ton.Make:GODREJ/L&T/BLUE STAR/WHIRLPOOL/VOLTAS |
6 | Compressor Suitable for Split ACof Capacity 3.0 Ton. Make:GODREJ/L&T/BLUE STAR/WHIRLPOOL/VOLTAS |
7 | Capacitor of capacity 25 MFD |
8 | Capacitor of capacity 30 MFD |
9 | Capacitor of capacity 35/36 MFD |
10 | Capacitor of capacity 40/45 MFD |
11 | Capacitor of capacity 50 MFD |
12 | Capacitor of capacity 55/60 MFD |
13 | Capacitor of capacity 65 MFD |
14 | Capacitor of capacity 30+2 MFD |
15 | Capacitor of capacity 30+4 MFD |
16 | Capacitor of capacity 35/36+2.5 MFD |
17 | Capacitor of capacity 35/36+4 MFD |
18 | Capacitor of capacity 35/36+6 MFD |
19 | Capacitor of capacity 40/45+2.5 MFD |
20 | Capacitor of capacity 40/45+4MFD |
21 | Capacitor of capacity 40/45+6 MFD |
22 | Capacitor of capacity 50+2.5 MFD |
23 | Capacitor of capacity 50+4 MFD |
24 | Capacitor of capacity 50+6 MFD |
25 | Capacitor of capacity 55/60+2.5 MFD |
26 | Capacitor of capacity 55/60+4 MFD |
27 | Capacitor of capacity 55/60+6 MFD |
28 | Cooling Coil suitable for 1.5 Ton Capacity Window AC |
29 | Cooling Coil suitable for 2.0Ton Capacity Window AC |
30 | Cooling Coil suitable for 1.5 Ton Capacity Split AC |
31 | Cooling Coil suitable for 2.0 Ton Capacity Split AC |
32 | Cooling Coil suitable for 3.0 Ton Capacity Split AC |
33 | Swing motor suitable for 1.5 Ton Capacity Window type Air Conditioner as per existing sample |
34 | Swing motor suitable for 2.0 Ton Capacity Window type Air Conditioner as per existing sample |
35 | Swing motor blades suitable for 1.5 Ton Capacity Split type Air Conditioner as per existing sample |
36 | Swing motor blades suitable for 2.0 Ton Capacity Split type Air Conditioner as per existing sample |
37 | Swing motor suitable for 3.0 Ton Capacity Split type Air Conditioner as per existing sample |
38 | Swing motor blades suitable for 3.0 Ton Capacity Split type Air Conditioner as per existing sample |
39 | Supply only over load relay suitable for 1.5/2.0 Ton Window type AC |
40 | Over load relay suitable for 1.5/2.0 Ton Split type AC |
41 | Over load relay suitable for 3.0 Ton Split type AC |
42 | PVC Frontgril suitable for Window type AC of any Make suitable for 1.5/2.0Ton windowAC |
43 | AC indoor blower motor fan suitable for 1.5 Ton Capacity Window type AC |
44 | All as per item No. 1.42 here in before butsuitable for 2.0 Ton Capacity Window type AC |
45 | All as per Srl item No.1.42 here in before but suitable for1.5 Ton Split AC |
46 | All as per Srlitem No. 1.42 here in before but suitable for2.0 Ton Split AC |
47 | All as per Srl item No. 1.4 here in before but suitable for3.0 Ton Split AC |
48 | Blower motor fan blade suitable for 1.5/2.0 Windowtype AC |
49 | Blower motor fan blade suitable for 1.5/2.0 Split type AC |
50 | Blower motor fan blade suitable for 3.0 Split type AC |
51 | Condenser motor with fan blade suitable for 1.5 Ton capacity Window type AC |
52 | Condenser motor with fan blade suitable for 2.0Ton capacity Window type AC |
53 | Condenser motor with fan blade suitable for 1.5 Ton capacity Split type AC |
54 | Condenser motor with fan blade suitable for 2.0 Suitable for Split type AC |
55 | Condenser motor with fan blade suitable for 3.0 Suitable for Split type AC |
56 | Thermostat switch with knob suitable for AC of any capacity. |
57 | Air Filter Suitable for1.5/2.0/3.0 Ton Capacity Window/Split type Air conditioner |
58 | Capillary tube length as per existing size suitable for 1.5/2.0/3.0 Ton Capacity Air conditioner |
59 | PCB Circuit with remote control suitable for any make and capacity of 1.5/2.0 Ton Window type AC |
60 | PCB Circuit with remote control suitable for any make and Capacity of 1.5/2.0/3.0 split type capacity Air Conditioner . |
61 | PCB Circuit with remote control suitable for any make and Capacity of 1.5/2.0 Split type capacity inverter type Air Conditioner |
62 | Metal top with bottomsuitable for 16 Amps Capacity1.5/2.0/3.0 Ton Capacity Air conditionerMake:Anchor/Havells/Philips/polycab and as per site requirement. |
63 | Suction/Drain out pipe suitable for 1.5/2.0/3.0 ton capacity Suitable for Air conditioner as per sample complete |
64 | Insulation of size 1/4, 3/8for Split AC complete as per existing sample |
65 | Insulation of size 1/2 5/8for Split AC complete as per existing sample |
66 | Rubber bush suitable for 1.5/2.0/3.0 ton capacity Suitable for Air conditioneras per existing sample |
67 | Copper Tube of size 1/4/ 3/8 suitable for any type and any capacity Air conditioner as per existing sample |
68 | Copper Tube of size 1/2 /5/8 suitable for any type and any capacity Air conditioner |
69 | Plug nut of size 1/4 3/8 suitable for any type and any capacity Air conditioner |
70 | Plug nut of size 1/2 5/8 suitable for any type and any capacity Air conditioner |
71 | AC indoor AC unit back plate siitable for 1.5/2./3.0 Ton capacity Air conditioner |
72 | Power relay Contactor suitable for 1.5 Ton AC |
73 | Power relay Contactor suitable for 2.0 Ton AC |
74 | Power relay Contactor suitable for 3.0 Ton AC |
75 | AC indoor Main board suitable for 1.5 Ton Capacity Air Conditioner |
76 | AC indoor Main board suitable for 1.5 Ton Capacity Air Conditioner |
77 | AC indoor Main board suitable for 1.5 Ton Capacity Air Conditioner |
78 | Out door unit stand alongwith Bolt,nut with washers as per sample or existing size suitable for Split AC Outdoor unit capacity of 1.5/2.0/3.0 Ton |
79 | Refrigerent Gas R-22 |
80 | Refrigerent Gas R-410 a |
81 | Refrigerent Gas R-134(a) |
82 | NRV Suitable for Any Capacity& any Make Air conditioner |
83 | Remote cell suitable for Air Conditioner remote Controller |
84 | Universal type Remote Control suitable any model,any capacity of Split/Window type Air Conditioner |
85 | Refirgent Gas R-32 |
86 | WATER COOLER |
87 | Carry out day to day rectification any Make,any capacity ofWater Cooler complaints at Area I & Area IIlike testing of gas leakegefrom line any Capacity, replacement of defective any capacity of capacitor/Condensor,any size of Copper tube , drain out pipe, Cooling fan & cooling fan motor and cooling coil ,Compressor, over load relay, GI grill, , industrial metal plugtop and bottom, Suction pipe etc., complete allas directed by the Engineer-in-ChargeNote:(i) .Replacement of Spares and fitting shall be measuredand paid separately as "Supply only" under Srl item No.2.02 to 2.22.(ii)If required shifting of Water cooler shall be measured and paid separtely.(iii).Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department iv).Water coolerMechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day.(v).Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II .(vi).Attending the complaints not less than min three complaints per day (vii) Spare parts shall be measured and paid separately there rate above Rs. 100/- |
88 | Compressor suitable for 60/120 Water cooler capacity |
89 | Compressor suitable for 40/80 Water cooler capacity |
90 | Compressor suitable for 150/150 Water cooler capacity |
91 | Compressor suitable for 40/40Water cooler capacity |
92 | Compressor suitable for 150/180 Water cooler capacity |
93 | Starting Capacitor suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity |
94 | Running Capacitor suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity |
95 | Starting relay current type suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity |
96 | Over load Protector suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity |
97 | Thermostat switch with knobsuitable for compressor of water cooler 150/180,60/120 and 40/80 capacity |
98 | PVC float valve assy alongwith ball with complete accessories for water cooler any capacity of size 15 mm dia . Make: Prayag/waterman/leader or equalvent |
99 | Self closing water tap 15 mm dia chromium plated inner/outer thread for water cooler 150/180,60/120 and 40/80 capacityas per sample Make: Waterman/Leader |
100 | Air Filter Suitable forwater cooler 150/180,60/120 and 40/80 capacity |
101 | Capillary tube of suitable length as per existing size for water cooler150/180,60/120 and 40/80 capacity |
102 | PVC Drain out pipe as per sample |
103 | PVC Flexible extension pipe 15 mm dia, Make Prayag/V Guard/Leader |
104 | Cooling Coil suitable for 150/180,60/120 and 40/80 capacity Water Cooler |
105 | Cooling coil Motor suitable for 150/180,60/120 and 40/80 capacity Water Cooler |
106 | Cooling coil Motor fan blade suitable for 150/180,60/120 and 40/80 capacity Water Cooler |
107 | Sheet metal enclosures with flush mounted type plug and socket with 240 V SP MCB 20 ampsCapacityMake:ABB/Legrand/Havells or Equivalent |
108 | M&L for water cooler Stainless storage tank brazing/welding of damage/crack portion and making good condition including replacement of Bolt,nut with washers and testing complete |
109 | REFRIGERATOR |
110 | Carry out day to day rectification any Make,any capacity ofRefrigerator complaints at Area I & Area IIlike testing of gas leakegefrom line any Capacity, replacement of defective any capacity of capacitor/Condensor,any size of Copper tube , drain out pipe, Cooling fan & cooling fan motor and cooling coil ,Compressor, over load relay, Vegitable tray, Magnetic gasket, Freezer, PVC Plugtop and bottom, etc.,complete allas directed by the Engineer-in-ChargeNote: (i) .Replacement of Spares and fitting shall be measuredand paid separately as "Supply only" under Srl item No.3.02 to 3.19.(ii)If required shifting of Refrigerator shall be measured and paid separtely.(iii).Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv).RefrigratorMechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day.(v).Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II .(vi).Attending the complaints not less than min three complaints per day (vii) Spare parts shall be measured and paid separately there rate above Rs. 100/- |
111 | Compressor suitable for 195 to 210 Ltrs Capacity Refrigerator |
112 | Compressor suitable for 195 to 225 to 250 Ltrs Capacity Refrigerator |
113 | Compressor suitable for 260to 310 Ltrs Capacity Refrigerator |
114 | Magnetic door gasket suitable for 165to200 ltrs capacity Refrigerator as per sample |
115 | Magnetic door gasket suitable for 286/320 Ltrs capacity Refigerator as per sample (Double Door) |
116 | Freezer suitable for165 to 200 ltrs capacity Refrigerator |
117 | Freezersuitable for 286/310 Ltrs capacity Refigerator |
118 | Relay current typeand over load protector suitable for compressor complete Make:Ranutrol/Voltas/LG |
119 | Thermostat auto defrost type suitable for any make and any capacity Refrigerator |
120 | Air Filter suitable for for any make and any capacity Refrigerator |
121 | Capillary tube of suitable length as per existing size for refrigerator any make and any capacity |
122 | Vegitable tray with Glass cover as per sample and suitable for refrigertator any type and any make |
123 | PVC Stand for Refigerator capacity any make and any capacity as per sample |
124 | PVC top 16 Amps Suitable for any capacity and any make Refrigerator as per sample |
125 | PVC Nylon Roller as per sample |
126 | Contensor Coil suitable for any model and capacity Refrigerator as per sample |
127 | Evaporator Coil suitable for any model and capacity Refrigerator as per sample |
128 | Expansion valve suitable for any model and capacity Refrigerator as per sample |
129 | DEEP FREEZER |
130 | Carry out day to day rectification any Make,any capacity ofDeep Freezer complaints at Area I & Area IIlike testing of gas leakegefrom line any Capacity, replacement of defective any capacity of capacitor/Condensor,any size of Copper tube , drain out pipe, Cooling fan & cooling fan motor and cooling coil ,Compressor, over load relay, Magnetic gasket,PVC Plugtop and bottom, Door Lock, MS Hings, Trolley Nylon roller alingwith bracket etc complete allas directed by the Engineer-in-ChargeNote: (i) .Replacement of Spares and fitting shall be measuredand paid separately as "Supply only" under Srl item No.4.02 to 4.11.(ii)If required shifting of Deep Freezer shall be measured and paid separtely.(iii).Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv). Deep Freezer Mechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day.(v).Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II .(vi).Attending the complaints not less than min three complaints per day (vii) Spare parts shall be measured and paid separately there rate above Rs. 100/- |
131 | Compressor Suitable for 300 Ltrs Capacity Deep Freezer |
132 | Compressor Suitable for 500 Ltrs Capacity Deep Freezer |
133 | Relay current type and over load protector suitable for compressor |
134 | Thermostat auto defrost type suitable for any make and any capacity Deep Freezer Make:Danfos/Ind Foss/renutrol or equivalent |
135 | Drier filter complete set suitable for any make and any capacity Deep Freezer |
136 | Indicating lamp (Red and Green) 230V complete suitable for any make and any capacity Deep Freezer as per sample complete |
137 | Capillary tube of suitable length as per existing size for Deep freezer any make and any capacity |
138 | Starting relay suitable for310/320 ltrs capacity Deep freezer |
139 | Condenser motor (Rotary fan) suitable for any type and any capacity deep freezerMake;AUE/Cool Blow/Universal or equivalent |
140 | Starting capacitor suitable for Deep freezer suitable for any type and any capacity deep freezer |
141 | DESERT COOLER |
142 | Carry out day to day rectification any Make,any capacity of Desrt Cooler Complaints at Area I & Area IIlike testing of desert cooler any Capacity, replacement of defectivecapacitor, selector switch., Indication lamp, 5 Amps switch , Fan blade, Fan Motor, PVC Connector, PVC Hose,woodnen wool with mesh, Bolt,nuts along with washers, Water pumpalongwith bracket, wiring etc complete allas directed by the Engineer-in-ChargeNote (i) .Replacement of Spares and fitting shall be measuredand paid separately as "Supply only" under Srl item No.5.02 to 5.14 .(ii)If required shifting of desert cooler shall be measured and paid separtely.(iii).Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv). Desert cooler Mechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day.(v).Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II .(vi).Attending the complaints not less than min three complaints per day (vii) Spare parts shall be measured and paid separately there rate above Rs. 100/- |
143 | Fan motor of capacity 1/6 HP (125 W), 230 V, 50 Hz, SP, AC supply confirming to IS-996/79 (motor only) with mounting accessories Make- Khaitan/Cool Blow/CG/Bajai |
144 | Water circulating submesible pump, 1300 RPM, SP, 230V, 50Hz 1.5M head , discharge 7.0 Ltrs/hrMake:indo/summer cool |
145 | Filter pad made out of wooden wool suitalbe for Air grills of desert cooler as per existing size |
146 | PVC Flexible hose suitable for desert coolercooling system |
147 | PVC Fan Blade suitable for 3000/4000/5000/6000 as per sample |
148 | Selector switch as per existing model& size and three varient speed control |
149 | Bolt, nut with washers as per sample |
150 | PVC Connector i.e (Elbow, Tee,4 way etc) |
151 | Switch 5 Amps |
152 | Indication lamp |
153 | Front Panel as per existing size and model |
154 | PVC swirtch box as per sample and size |
155 | GI Chicken Mesh |
156 | M&L for sub main wiring with 6 Sqmm (Nominal area) with two runs (Red for phase and Black for neutral) of single core, PVC insulated, FR multistranded, unsheathed, copper conductor cables 1100 V grade drawn through PVC conduits/casing-caping fixed to wall/ceiling etc including 2x 6 sqmm + 2.5 Sqmm earth wire single core, PVC insulated, multistranded,unsheathed, copper conductor green in colour as earth wire and duly connected to earth point including taking downcomplete as specified and directed.complete all as specified and as directed by Engineer-in charge. Note :- (a) PVC conduits/casing caping and Two runs cables and one run of earth wire will be measured as one length. |
157 | M&L for sub main wiring with 2.5 Sqmm (nominal area), PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 2x2.5Sqmmand 1x2.5 Sqmm earth wire PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light point controlled by one ,one way switches including taking down as specified and directed. complete all as specified and as directed . Note :- (a) PVC conduits/casing caping and Two runs cables and one run of earth wire will be measured as one length. |
158 | Carry out day to day rectification any Make,any capacity of Air Curtains Complaints at Area I & Area IIlike testing of Air Curtain any Capacity, replacement of defectivecapacitor, , Indication lamp, 5 Amps switch , Fan blade, Fan Motor, PVC Connector,alongwith bracket, wiring etc complete allas directed by the Engineer-in-ChargeNote (i) .Replacement of Spares and fitting shall be measuredand paid separately.(ii)If required shifting of Air curtain shall be measured and paid separtely.(iii).Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv). Air curtain Mechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day.(v).Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II |
159 | M&L for framed work such as in cooler stand, water tanks/desert cooler stand and similar work con-forming to Fe 290 Gde E-165including mounting on wall with suitable size nut bolt and grounting and making good disturbed surface complete all as specified and directed |
160 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and directed. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy