Tender For Repair And Maintenance Of Summer Appliances Under Ge Saugor, sagar-Madhya Pradesh

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Summer Appliances Under Ge Saugor. Submission Date for this Tender is 03-02-2023. Air Conditioner Tenders in sagar Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

35609415
Corrigendum : Tender For Repair And Maintenance Of Summer Appliances Under Ge Saugor
Open Tender
Indian
Madhya Pradesh
sagar
03-02-2023

Tender Details

Repair And Maintenance Of Summer Appliances Under Ge Saugor

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Jan-2023 Revised BOQ BOQ 27-01-2023
2 27-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-02-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
INR 20 Lakhs /-

BOQ Items

Name of Work:REPAIR AND MAINT OF SUMMER APPLIANCES UNDER GE SAUGOR
Sl. No. Item Description
1AIR CONDITIONER (SPLIT/WINDOW/WALK-IN-COOLER)
2Carry out day to day complaintrectification and periodical service maintenance as per manual recommendation at Area I & Area IIlike testing of gas leakegefrom line any Capacity, replacement of defective any capacity of capacitor/Condensor,any size of Copper tube alongwith insulation pipe, drain out pipe, Cooling fan & cooling fan motor and cooling coil ,Compressor, air filter, Swing motor, over load relay, PVC grill, PCB circuit board along with remote control, Condensor motor & fan blade , industrial metal plugtop and bottom, Plug nut, Suction pipe, Charging Gas, Testing of gas leakeage using nitrazen gas, Cleaning of the Filters, checking control Wiring ,etc., complete allas directed by the Engineer-in-ChargeNote: (i) Replacement of Spares and fitting shall be measuredand paid separately as "Supply only" under Srl item No.1.02 to 1.84 .(ii)If required shifting of Split /Window AC shall be measured and paid separtely.(iii)Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv). AC Mechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day.(v)Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II . (vi)Attending the complaints not less than min three complaints per day (vii) Spare parts shall be measured and paid separately if their rate above Rs. 100/-
3Compressor suitable for window/Split AC of capacity 1.5 Ton. Make:GODREJ/L&T/BLUE STAR/WHIRLPOOL/VOLTAS
4Compressor suitable for window/Split AC of capacity 2.0 Ton.Make:GODREJ/L&T/BLUE STAR/WHIRLPOOL/VOLTAS
5Compressor suitable forWalk incooler installed at MH saugor Medical store Hermaticallytype capacity of2.0 Ton.Make:GODREJ/L&T/BLUE STAR/WHIRLPOOL/VOLTAS
6Compressor Suitable for Split ACof Capacity 3.0 Ton. Make:GODREJ/L&T/BLUE STAR/WHIRLPOOL/VOLTAS
7Capacitor of capacity 25 MFD
8Capacitor of capacity 30 MFD
9Capacitor of capacity 35/36 MFD
10Capacitor of capacity 40/45 MFD
11Capacitor of capacity 50 MFD
12Capacitor of capacity 55/60 MFD
13Capacitor of capacity 65 MFD
14Capacitor of capacity 30+2 MFD
15Capacitor of capacity 30+4 MFD
16Capacitor of capacity 35/36+2.5 MFD
17Capacitor of capacity 35/36+4 MFD
18Capacitor of capacity 35/36+6 MFD
19Capacitor of capacity 40/45+2.5 MFD
20Capacitor of capacity 40/45+4MFD
21Capacitor of capacity 40/45+6 MFD
22Capacitor of capacity 50+2.5 MFD
23Capacitor of capacity 50+4 MFD
24Capacitor of capacity 50+6 MFD
25Capacitor of capacity 55/60+2.5 MFD
26Capacitor of capacity 55/60+4 MFD
27Capacitor of capacity 55/60+6 MFD
28Cooling Coil suitable for 1.5 Ton Capacity Window AC
29Cooling Coil suitable for 2.0Ton Capacity Window AC
30Cooling Coil suitable for 1.5 Ton Capacity Split AC
31Cooling Coil suitable for 2.0 Ton Capacity Split AC
32Cooling Coil suitable for 3.0 Ton Capacity Split AC
33Swing motor suitable for 1.5 Ton Capacity Window type Air Conditioner as per existing sample
34Swing motor suitable for 2.0 Ton Capacity Window type Air Conditioner as per existing sample
35Swing motor blades suitable for 1.5 Ton Capacity Split type Air Conditioner as per existing sample
36Swing motor blades suitable for 2.0 Ton Capacity Split type Air Conditioner as per existing sample
37Swing motor suitable for 3.0 Ton Capacity Split type Air Conditioner as per existing sample
38Swing motor blades suitable for 3.0 Ton Capacity Split type Air Conditioner as per existing sample
39Supply only over load relay suitable for 1.5/2.0 Ton Window type AC
40Over load relay suitable for 1.5/2.0 Ton Split type AC
41Over load relay suitable for 3.0 Ton Split type AC
42PVC Frontgril suitable for Window type AC of any Make suitable for 1.5/2.0Ton windowAC
43AC indoor blower motor fan suitable for 1.5 Ton Capacity Window type AC
44All as per item No. 1.42 here in before butsuitable for 2.0 Ton Capacity Window type AC
45All as per Srl item No.1.42 here in before but suitable for1.5 Ton Split AC
46All as per Srlitem No. 1.42 here in before but suitable for2.0 Ton Split AC
47All as per Srl item No. 1.4 here in before but suitable for3.0 Ton Split AC
48Blower motor fan blade suitable for 1.5/2.0 Windowtype AC
49Blower motor fan blade suitable for 1.5/2.0 Split type AC
50Blower motor fan blade suitable for 3.0 Split type AC
51Condenser motor with fan blade suitable for 1.5 Ton capacity Window type AC
52Condenser motor with fan blade suitable for 2.0Ton capacity Window type AC
53Condenser motor with fan blade suitable for 1.5 Ton capacity Split type AC
54Condenser motor with fan blade suitable for 2.0 Suitable for Split type AC
55Condenser motor with fan blade suitable for 3.0 Suitable for Split type AC
56Thermostat switch with knob suitable for AC of any capacity.
57Air Filter Suitable for1.5/2.0/3.0 Ton Capacity Window/Split type Air conditioner
58Capillary tube length as per existing size suitable for 1.5/2.0/3.0 Ton Capacity Air conditioner
59PCB Circuit with remote control suitable for any make and capacity of 1.5/2.0 Ton Window type AC
60PCB Circuit with remote control suitable for any make and Capacity of 1.5/2.0/3.0 split type capacity Air Conditioner .
61PCB Circuit with remote control suitable for any make and Capacity of 1.5/2.0 Split type capacity inverter type Air Conditioner
62Metal top with bottomsuitable for 16 Amps Capacity1.5/2.0/3.0 Ton Capacity Air conditionerMake:Anchor/Havells/Philips/polycab and as per site requirement.
63Suction/Drain out pipe suitable for 1.5/2.0/3.0 ton capacity Suitable for Air conditioner as per sample complete
64Insulation of size 1/4, 3/8for Split AC complete as per existing sample
65Insulation of size 1/2 5/8for Split AC complete as per existing sample
66Rubber bush suitable for 1.5/2.0/3.0 ton capacity Suitable for Air conditioneras per existing sample
67Copper Tube of size 1/4/ 3/8 suitable for any type and any capacity Air conditioner as per existing sample
68Copper Tube of size 1/2 /5/8 suitable for any type and any capacity Air conditioner
69Plug nut of size 1/4 3/8 suitable for any type and any capacity Air conditioner
70Plug nut of size 1/2 5/8 suitable for any type and any capacity Air conditioner
71AC indoor AC unit back plate siitable for 1.5/2./3.0 Ton capacity Air conditioner
72Power relay Contactor suitable for 1.5 Ton AC
73Power relay Contactor suitable for 2.0 Ton AC
74Power relay Contactor suitable for 3.0 Ton AC
75AC indoor Main board suitable for 1.5 Ton Capacity Air Conditioner
76AC indoor Main board suitable for 1.5 Ton Capacity Air Conditioner
77AC indoor Main board suitable for 1.5 Ton Capacity Air Conditioner
78Out door unit stand alongwith Bolt,nut with washers as per sample or existing size suitable for Split AC Outdoor unit capacity of 1.5/2.0/3.0 Ton
79Refrigerent Gas R-22
80Refrigerent Gas R-410 a
81Refrigerent Gas R-134(a)
82NRV Suitable for Any Capacity& any Make Air conditioner
83Remote cell suitable for Air Conditioner remote Controller
84Universal type Remote Control suitable any model,any capacity of Split/Window type Air Conditioner
85Refirgent Gas R-32
86WATER COOLER
87Carry out day to day rectification any Make,any capacity ofWater Cooler complaints at Area I & Area IIlike testing of gas leakegefrom line any Capacity, replacement of defective any capacity of capacitor/Condensor,any size of Copper tube , drain out pipe, Cooling fan & cooling fan motor and cooling coil ,Compressor, over load relay, GI grill, , industrial metal plugtop and bottom, Suction pipe etc., complete allas directed by the Engineer-in-ChargeNote:(i) .Replacement of Spares and fitting shall be measuredand paid separately as "Supply only" under Srl item No.2.02 to 2.22.(ii)If required shifting of Water cooler shall be measured and paid separtely.(iii).Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department iv).Water coolerMechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day.(v).Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II .(vi).Attending the complaints not less than min three complaints per day (vii) Spare parts shall be measured and paid separately there rate above Rs. 100/-
88Compressor suitable for 60/120 Water cooler capacity
89Compressor suitable for 40/80 Water cooler capacity
90Compressor suitable for 150/150 Water cooler capacity
91Compressor suitable for 40/40Water cooler capacity
92Compressor suitable for 150/180 Water cooler capacity
93Starting Capacitor suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity
94Running Capacitor suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity
95Starting relay current type suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity
96Over load Protector suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity
97Thermostat switch with knobsuitable for compressor of water cooler 150/180,60/120 and 40/80 capacity
98PVC float valve assy alongwith ball with complete accessories for water cooler any capacity of size 15 mm dia . Make: Prayag/waterman/leader or equalvent
99Self closing water tap 15 mm dia chromium plated inner/outer thread for water cooler 150/180,60/120 and 40/80 capacityas per sample Make: Waterman/Leader
100Air Filter Suitable forwater cooler 150/180,60/120 and 40/80 capacity
101Capillary tube of suitable length as per existing size for water cooler150/180,60/120 and 40/80 capacity
102PVC Drain out pipe as per sample
103PVC Flexible extension pipe 15 mm dia, Make Prayag/V Guard/Leader
104Cooling Coil suitable for 150/180,60/120 and 40/80 capacity Water Cooler
105Cooling coil Motor suitable for 150/180,60/120 and 40/80 capacity Water Cooler
106Cooling coil Motor fan blade suitable for 150/180,60/120 and 40/80 capacity Water Cooler
107Sheet metal enclosures with flush mounted type plug and socket with 240 V SP MCB 20 ampsCapacityMake:ABB/Legrand/Havells or Equivalent
108M&L for water cooler Stainless storage tank brazing/welding of damage/crack portion and making good condition including replacement of Bolt,nut with washers and testing complete
109REFRIGERATOR
110Carry out day to day rectification any Make,any capacity ofRefrigerator complaints at Area I & Area IIlike testing of gas leakegefrom line any Capacity, replacement of defective any capacity of capacitor/Condensor,any size of Copper tube , drain out pipe, Cooling fan & cooling fan motor and cooling coil ,Compressor, over load relay, Vegitable tray, Magnetic gasket, Freezer, PVC Plugtop and bottom, etc.,complete allas directed by the Engineer-in-ChargeNote: (i) .Replacement of Spares and fitting shall be measuredand paid separately as "Supply only" under Srl item No.3.02 to 3.19.(ii)If required shifting of Refrigerator shall be measured and paid separtely.(iii).Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv).RefrigratorMechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day.(v).Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II .(vi).Attending the complaints not less than min three complaints per day (vii) Spare parts shall be measured and paid separately there rate above Rs. 100/-
111Compressor suitable for 195 to 210 Ltrs Capacity Refrigerator
112Compressor suitable for 195 to 225 to 250 Ltrs Capacity Refrigerator
113Compressor suitable for 260to 310 Ltrs Capacity Refrigerator
114Magnetic door gasket suitable for 165to200 ltrs capacity Refrigerator as per sample
115Magnetic door gasket suitable for 286/320 Ltrs capacity Refigerator as per sample (Double Door)
116Freezer suitable for165 to 200 ltrs capacity Refrigerator
117Freezersuitable for 286/310 Ltrs capacity Refigerator
118Relay current typeand over load protector suitable for compressor complete Make:Ranutrol/Voltas/LG
119Thermostat auto defrost type suitable for any make and any capacity Refrigerator
120Air Filter suitable for for any make and any capacity Refrigerator
121Capillary tube of suitable length as per existing size for refrigerator any make and any capacity
122Vegitable tray with Glass cover as per sample and suitable for refrigertator any type and any make
123PVC Stand for Refigerator capacity any make and any capacity as per sample
124PVC top 16 Amps Suitable for any capacity and any make Refrigerator as per sample
125PVC Nylon Roller as per sample
126Contensor Coil suitable for any model and capacity Refrigerator as per sample
127Evaporator Coil suitable for any model and capacity Refrigerator as per sample
128Expansion valve suitable for any model and capacity Refrigerator as per sample
129DEEP FREEZER
130Carry out day to day rectification any Make,any capacity ofDeep Freezer complaints at Area I & Area IIlike testing of gas leakegefrom line any Capacity, replacement of defective any capacity of capacitor/Condensor,any size of Copper tube , drain out pipe, Cooling fan & cooling fan motor and cooling coil ,Compressor, over load relay, Magnetic gasket,PVC Plugtop and bottom, Door Lock, MS Hings, Trolley Nylon roller alingwith bracket etc complete allas directed by the Engineer-in-ChargeNote: (i) .Replacement of Spares and fitting shall be measuredand paid separately as "Supply only" under Srl item No.4.02 to 4.11.(ii)If required shifting of Deep Freezer shall be measured and paid separtely.(iii).Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv). Deep Freezer Mechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day.(v).Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II .(vi).Attending the complaints not less than min three complaints per day (vii) Spare parts shall be measured and paid separately there rate above Rs. 100/-
131Compressor Suitable for 300 Ltrs Capacity Deep Freezer
132Compressor Suitable for 500 Ltrs Capacity Deep Freezer
133Relay current type and over load protector suitable for compressor
134Thermostat auto defrost type suitable for any make and any capacity Deep Freezer Make:Danfos/Ind Foss/renutrol or equivalent
135Drier filter complete set suitable for any make and any capacity Deep Freezer
136Indicating lamp (Red and Green) 230V complete suitable for any make and any capacity Deep Freezer as per sample complete
137Capillary tube of suitable length as per existing size for Deep freezer any make and any capacity
138Starting relay suitable for310/320 ltrs capacity Deep freezer
139Condenser motor (Rotary fan) suitable for any type and any capacity deep freezerMake;AUE/Cool Blow/Universal or equivalent
140Starting capacitor suitable for Deep freezer suitable for any type and any capacity deep freezer
141DESERT COOLER
142Carry out day to day rectification any Make,any capacity of Desrt Cooler Complaints at Area I & Area IIlike testing of desert cooler any Capacity, replacement of defectivecapacitor, selector switch., Indication lamp, 5 Amps switch , Fan blade, Fan Motor, PVC Connector, PVC Hose,woodnen wool with mesh, Bolt,nuts along with washers, Water pumpalongwith bracket, wiring etc complete allas directed by the Engineer-in-ChargeNote (i) .Replacement of Spares and fitting shall be measuredand paid separately as "Supply only" under Srl item No.5.02 to 5.14 .(ii)If required shifting of desert cooler shall be measured and paid separtely.(iii).Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv). Desert cooler Mechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day.(v).Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II .(vi).Attending the complaints not less than min three complaints per day (vii) Spare parts shall be measured and paid separately there rate above Rs. 100/-
143Fan motor of capacity 1/6 HP (125 W), 230 V, 50 Hz, SP, AC supply confirming to IS-996/79 (motor only) with mounting accessories Make- Khaitan/Cool Blow/CG/Bajai
144Water circulating submesible pump, 1300 RPM, SP, 230V, 50Hz 1.5M head , discharge 7.0 Ltrs/hrMake:indo/summer cool
145Filter pad made out of wooden wool suitalbe for Air grills of desert cooler as per existing size
146PVC Flexible hose suitable for desert coolercooling system
147PVC Fan Blade suitable for 3000/4000/5000/6000 as per sample
148Selector switch as per existing model& size and three varient speed control
149Bolt, nut with washers as per sample
150PVC Connector i.e (Elbow, Tee,4 way etc)
151Switch 5 Amps
152Indication lamp
153Front Panel as per existing size and model
154PVC swirtch box as per sample and size
155GI Chicken Mesh
156M&L for sub main wiring with 6 Sqmm (Nominal area) with two runs (Red for phase and Black for neutral) of single core, PVC insulated, FR multistranded, unsheathed, copper conductor cables 1100 V grade drawn through PVC conduits/casing-caping fixed to wall/ceiling etc including 2x 6 sqmm + 2.5 Sqmm earth wire single core, PVC insulated, multistranded,unsheathed, copper conductor green in colour as earth wire and duly connected to earth point including taking downcomplete as specified and directed.complete all as specified and as directed by Engineer-in charge. Note :- (a) PVC conduits/casing caping and Two runs cables and one run of earth wire will be measured as one length.
157M&L for sub main wiring with 2.5 Sqmm (nominal area), PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 2x2.5Sqmmand 1x2.5 Sqmm earth wire PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light point controlled by one ,one way switches including taking down as specified and directed. complete all as specified and as directed . Note :- (a) PVC conduits/casing caping and Two runs cables and one run of earth wire will be measured as one length.
158Carry out day to day rectification any Make,any capacity of Air Curtains Complaints at Area I & Area IIlike testing of Air Curtain any Capacity, replacement of defectivecapacitor, , Indication lamp, 5 Amps switch , Fan blade, Fan Motor, PVC Connector,alongwith bracket, wiring etc complete allas directed by the Engineer-in-ChargeNote (i) .Replacement of Spares and fitting shall be measuredand paid separately.(ii)If required shifting of Air curtain shall be measured and paid separtely.(iii).Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv). Air curtain Mechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day.(v).Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II
159M&L for framed work such as in cooler stand, water tanks/desert cooler stand and similar work con-forming to Fe 290 Gde E-165including mounting on wall with suitable size nut bolt and grounting and making good disturbed surface complete all as specified and directed
160M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail