Kolkata Municipal Corporation-KMC has published Tender For Augmenting Lt Service With New Transformer At Patuli Bps.. Submission Date for this Tender is 25-01-2023. Coats and Jackets Tenders in Kolkata West Bengal. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supply & delivery of 415V,50 Hz, 50/60 KA Manually Drawout type, 4-pole following Microprocessor based Air Circuit Breaker (Thermal Magnetic DN1) Capacity (make L&T/ABB/SCHNEIDER):800 Amps (50 KA) |
2 | Supply and delivery of MCCBs with thermal magnetic release breaking capacity Thermal release rang 125-160A, Breaking capacity Icu at 415V AC,50Hz, 50KA4pole |
3 | Supply and delivery of MCCBs with thermal magnetic release breaking capacity Thermal release rang 320-400A, Breaking capacity Icu at 415V AC,50Hz, 50KA, 4 pole |
4 | Supply and delivery of extended rotary handel of MCCBs (Make: L & T/ABB/ Schneider/Simence/ GE) Extended rotary handle 250-400A, 415V |
5 | Supply and delivery of extended rotary handel of MCCBs (Make: L & T/ABB/ Schneider/Simence/ GE) Extended rotary handle 100-160A, 415V |
6 | Supply and delivery of spreader Terminal of MCCBs (Make: L & T/ABB/ Schneider/Simence/ GE) 125A, 3 pole |
7 | Supply and delivery of spreader Terminal of MCCBs (Make: L & T/ABB/ Schneider/Simence/ GE) 400A, 3 pole |
8 | Supply & fixing of 415/440 Volt, HRC fuse (Make: L&T/ Havels/CGL/GE).for 250 Amp Supply and fixing of analog Ammeter ranging 0-100Amps having C.R ratio of 100/5A, 144 mm sq size (make:AE/KAPPA/IMP). |
9 | Supply and fixing of analog voltmeter ranging from 0-500 V of 144 mm sq size (make :AE/KAPPA/IMP). |
10 | Supply & delivery of the following Current Transformer (Make: KAPPA/AE): Ratio 500/5A 15 1 |
11 | Supply & fixing of 230/240V, LED indicating lamp (make :AE/KAPPA/IMP) other than Blue/ white color. |
12 | SUPPLY AND DELIVERY OF AMMETER SELECTOR SWITCH 3 WAY & OFF , 440V AC, 10 A |
13 | SUPPLY AND DELIVERY OF VOLTMETER SELECTOR SWITCH 440V AC, 10 A |
14 | Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/):Size in Sq. mm, No & dia. of wire in mm , No of Core - 25 7/2.24 3… |
15 | Supply and delivery Modular Push button actuators(with plastic front ring),Illuminated actuator (with holder for contact block) (Make: L & T/ABB/ Schneider/Simence/ GE)Normal, colour: Red, green, blue, Amber white, yellow, clear |
16 | Supply and fixing of 240/230 volt, 50 Hz, T.P., power contactor (Make: L & T/ABB/Schneider/Simence/ GE) having contact block of the following range.9-25Amp, 1NO/1NC |
17 | Supplying of Bakelite Sheet 3 mm thick |
18 | 2.5 sqmm"FR" stranded Copper Wire |
19 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.2.5sqmm |
20 | Copper Plate,Copper Strip |
21 | Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required ... ( As per Drawing no. 470 of PWD Specification Book ... May 1991) Dimension ofAl 4 x (2x 40x5) mm. bars[85mm long) Dimension of Sheet 500x150mm Metal Box Rate / Mt.of completechamber 415 V, 600 A |
22 | Supplying & Erection of big size feeder pillar box of Size (1372 x 914 x 607 mm) made up of 3.15 mm thick MS Plate along with suitable M.S. Angle. The P.B. have double hinge door at the front & back with suitable locking arrangement. The box will be painted by 2 cores of aluminiam paint over 1 coat of red oxide paint. Suitable arrangement should be provided for fixing of Timer unit, fuse unit & other accessories. Leg of the pillar box will be 900 mm in length by made up of (35x35x3 mm MS Angle with suitable base Plate. Legs of the Pillar box will be erected at 300 mm below the ground level with cement concrete (6:3:1). Rest portion coverd by 5" Brick Wall with plastering & net cement & bottom portion filled with silver sand as drawing & direction of E.I.C. |
23 | Supplying of the following HIGH TENSION XLPE Cables (make:Polycab/Gloster/Havells): 3Core x 185 sq mm 11 KV(UE) XLPE |
24 | Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/):Size in Sq. mm, No & dia. of wire in mm , No of Core - 500 4 |
25 | SUPPLY OF COPPER CONDUCTOR , PVC INSULATED ARMOURED 1100 VOLTS GRADE CONTROL CABLE OF SIZE 2.5 SQ.MM X 10 CORE |
26 | Compression Glands.Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring FOR dust & moisture(proof entry of XLPE/PVC armoured cables as below : FOR 3 core.(xii)upto 185 sqmm |
27 | Compression Glands.Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring FOR dust & moisture(proof entry of XLPE/PVC armoured cables as below : FOR 4 core.(xv)upto 400 sqmm |
28 | Finishing cable ends.(b)Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.3... core 300 sqmm cable |
29 | Making Indoor type End termination Joint by providing all required terminal joints accessories {viz Heat Shrink Type End Termination Jointing Kits complete with all accessories for 3 core 6.6KV(UE)-11KV (E) XLPE Screened Cable, Aluminium Conductor}& man/equipments tools & tackles etc with the relevant Switch Gear inside the Pumping Station or Switch Room with care & caution including compliance of relevant safety norms & conforms to the relevant IS and complete in all respect as per direction of EIC. 3 core 6.6KV (UE)-11KV (E) XLPE Screened Cable, Aluminium Conductor of following Sizes 240- 300 Sq mm Indoor type Heat Shrinkable Joint (Rechem KIT No- EPKT 3121) |
30 | Supply & Fixing of per FORated GI cable tray with per FORation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. With 25x25x3mm angle iron support 300x50x1.25mm (18SWG) |
31 | Laying on Cable Tray.Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire.(i)Up to 50 sqmm |
32 | Laying on Cable Tray.Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire.(iii)Above 150 sqmm |
33 | Laying through RCC/Hume/GI Pipe.(b)Laying only Cable above 50 sqmm but not exceeding 400sqmm through existing RCC/ Hume/GI Pipe/open masonary trench FOR single, 2, 3, 3... and 4 core |
34 | Excavation of soil FOR installation of Earth Electrode and filling & ramming.FOR Morrum Soil. |
35 | Earthing Installation by GI pipe ... (FOR Sub(station Neutral/Equipment earthing).Earthing with 65 mm dia GI pipe (TATA(Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (HOT Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts |
36 | Earthing with Copper plate (6)10x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3).20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI Medium) protection (4) mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI Medium) FOR periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke FOR plate electrode |
37 | Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (HOT Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. |
38 | Earthing connection from earth electrode to Trans FORmer Neutral/Earth Busbar.Extra FOR connecting the neutral of Trans FORmer/Earth busbar to earth electrode including S & F 50 mm x 6 mm Galvanized (HOT Dip) steel strip on wall/floor with GI saddles & insulating the same by one layer of PVC strip over one layer of ampere tape |
39 | REPAIR, SERVICING & OVERHAULING OF HT SWITCH GEAR. |
40 | DEHYDRATION AND FILTRATION OF TRASFORMER OIL IN ORDER TO DEVELOPE THE DIELECTRIC STRENGTH OF OIL TO ITA SUITABLE REQUIED VALE ETC AND CHECKING THE BREAKDOWN VOLTAGE AT 40 KV DC COMPLETE AS PER DIRECTION OF EIC |
41 | TESTING AND COMMISSIONING OF TRANSFORMER AND PAINTING THE OUT SIDE TRANSFORMER COMPLETE IN ALL RESPCT AS PER DIRECTION OF EIC |
42 | Estimated amount |
43 | Add: 18%GST |
44 | 1% LWC |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail