| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B |
| 2 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (a) 5/6 amps switch |
| 3 | (b) 3 pin 5/6 amp socket outlet |
| 4 | Supplying and fixing metal box of 180mm x 100mm x 60mm deep (nomnal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 6 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 7 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door |
| 8 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 KA \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single Pole) |
| 9 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 63 amps |
| 10 | Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DBcomplete with connections, testing and commissioning etc. asrequired. 25A |
| 11 | SITC of 250mm (10inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc as required |
| 12 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Up to 35 sq mm(clamped with 1 mm thick saddle) |
| 13 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the exisiting masonry open duct as required. Up to 35 sq. mm |
| 14 | supply of XLPE Insulated PVC Sheathed Al. Conductor Armoured Cable for working voltage upto 1.1kV confirming to IS-7098(Part-I) of following sizes:(a) 2 x 6 sq.mm |
| 15 | SITC of 1200 mm sweep BEE 5 star rated AC ceilling with brussless direct current motor, class of insulation:B, 3 nos. blade,30cm down road 2 nos. canopies shackle kit safety ropr,copper winding, power factor not less than .9,service value minimum 6.85,air delivery minimum 215 cmm,350 rpm,THD less than 10%,remote or electrnoic regulator unit for speed control and all remaining accessories including safety pin nuts,bolts,washertemperature rise=75 degree,insulation resistance more than 2 megha ohm,suitable for 230 v,50 hz,single phase ac supply, earthing etc complete as required fan for suitable for 230 V, 50 Hz AC supply. |
| 16 | SITC of LED Tube type luminaire 20 watt rating complete with Extruded Aluminum Batten prewired with high efficient LED with following specification. a) total system wattage=20watt+/-5%b) Luminous efficacy >=95 luminus/wattc). power factor >=.95 |
| 17 | Supply and fabrication of panel protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh and grounding the protection system in suitable quality of CC etc as reqd. |
| 18 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitablemethod prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All type of soil 200 mm dia |
| 19 | Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings& accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.125 mm nominal size dia |
| 20 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge125 mm nominal size dia |
| 21 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method,measuring static level & draw down etc. by step draw down method,collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 22 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia |
| 23 | Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts f required size complete. 150 mm dia |
| 24 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm dia |
| 25 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 25 mm dia nominal size |
| 26 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 32 mm dia nominal size |
| 27 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore. |
| 28 | Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin-charge. |
| 29 | P and F following sizes of PVC insulated and PVC sheathed copper conductor 3 core submersible cable confirming to IS.647/1990 etc. as reqd. Elec94.a 3 X 2.5 sq.mm. |
| 30 | Providing and laying cement concreat 1:2:4 mix for sanitary sealing of well at top of 450mmX 450mmX 500 mm deep from top comp as reqd. |
| 31 | Supply, Installation, testing and commissioning of cubical type control panel board for single phase submersible pumping set of following rating complete with contactor, relay , MCB ,condenser ,voltmeter, ammeter and indication lamp etc including connections etc as reqd. 1.5 H.P rating Submersible P/Set. |
| 32 | Supplying, lowering, testing and commissioning of following capacity vertical type, multistage, totally enclosed, water filled, deep well submersible pumping set complete i/c connections etc as reqd. Elec92.a Single phase 1.5 HP, having discharge of 60 LPM (approx.) at 50 M head. |
| 33 | Supply installation testing and commissioning of 30 watt LED Flood lightluminare fitted with lens made of pressure die cast aluminium housing and touighened glass cover i/c mounting bracket complete with following specifications. a) LED wattage 30+/-5%, b) Luminaries efficacy >100 lumens/watt, c) Pf. >0.95, d) Protection – IP 66 |
| 34 | Supplying and laying 6 mmsizes of steel flexible rope suitable for holding submersible pump set i/c clips etc as reqd. |