| 1 | Earth work in excavation by mechanical means (Hydraulicexcavator) / manual means over areas (exceeding 30cm indepth, 1.5m in width as well as 10 sqm on plan) includingdisposal of excavated earth, lead upto 50m and lift upto1.5m, disposed earth to be levelled and neatly dressed.-All kinds of soil |
| 2 | Earth work in excavation by mechanical means (Hydraulicexcavator) / manual means in foundation trenches ordrains (not exceeding 1.5 m in width or 10 sqm on plan)including dressing of sides and ramming of bottoms, liftupto 1.5 m, including getting out the excavated soil anddisposal of surplus excavated soil as directed, within a leadof 50 m.-All kinds of soil |
| 3 | Filling available excavated earth (excluding rock) intrenches, plinth, sides of foundations etc. in layers notexceeding 20cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and liftupto 1.5 m.-All kinds of soil |
| 4 | Supplying and filling in plinth, under floor, foundations etc.with sand (fine) from local quarry with all lifts includingspreading in horizontal layers, watering, grading torequired slope, ramming, consolidating and compactingeach layer by using plate compactor or by any suitablemethod complete. |
| 5 | Providing and laying in position cement concrete ofspecified grade excluding the cost of centring andshuttering --All work upto plinth level:4.1.7 1:4:8 ( 1 Cement: 4 fine sand : 8 graded stoneaggregate 40 mm nominal size) |
| 6 | Reinforced cement concrete work in beams, suspendedfloors, roofs having slope upto 15° landings, balconies,shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases upto floor five levelexcluding the cost of centring, shuttering, finishingand reinforcement5.3.2 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stoneaggregate 20 mm nominal size) |
| 7 | Reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding allcomplete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D ormore |
| 8 | Centering shuttering including struttings, propping etc.and removal of form work for:Suspended floors, roofs, landings, balconies and accessplatform with timber planks |
| 9 | First class brick work in foundation and plinthincluding cost of all materials as required complete:-6.1.5 In cement mortar 1:6 ( 1 cement : 6 fine sand ). |
| 10 | First class brick work in superstructure above plinthlevel & upto floor-five level including cost of allmaterials as required complete:-6.3.3 In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 11 | 10.5 Cement concrete flooring 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.10.5.1 40 mm thick with 20 mm nominal size stone aggregate |
| 12 | 12 mm cement plaster of mix12.1.2 Cement mortar 1:4 (1 cement : 4 fine sand) |
| 13 | Neat cement punning |
| 14 | 6 mm cement plaster of mix :12.4.1 Cement mortar 1:3 (1 cement : 3 fine sand) |
| 15 | Providing and fixing on wall face unplasticisedRigid PVC rain water pipes (working pressure 4kg/cm2) conforming to IS : 13592 Type A includingjointing with seal ring conforming to IS : 5382leaving 10 mm gap for thermal expansion:11.42.1 Single socketed pipe - 75 mm OD |
| 16 | Providing and fixing on wall face unplasticisedRigid PVC rain water pipes (working pressure 4kg/cm2) conforming to IS : 13592 Type A includingjointing with seal ring conforming to IS : 5382leaving 10 mm gap for thermal expansion:11.42.2 Single socketed pipe - 110 mm OD |
| 17 | Providing and fixing on wall face unplasticised - PVCmoulded fittings/ accessories for unplasticised RigidPVC rain water, soil, waste & vent pipes pipesconforming to IS : 13592 Type A including jointingwith seal ring conforming to IS : 5382 leaving 10 mmgap for thermal expansion:Single equal tee without door18.84.3.1 75x75x75 mm |
| 18 | Providing and fixing on wall face unplasticised - PVCmoulded fittings/ accessories for unplasticised RigidPVC rain water, soil, waste & vent pipes pipesconforming to IS : 13592 Type A including jointingwith seal ring conforming to IS : 5382 leaving 10 mmgap for thermal expansion:Single equal tee without door18.84.3.2 110x110x110mm |
| 19 | Providing and fixing on wall face unplasticised - PVCmoulded fittings/ accessories for unplasticised RigidPVC rain water, soil, waste & vent pipes pipesconforming to IS : 13592 Type A including jointingwith seal ring conforming to IS : 5382 leaving 10 mmgap for thermal expansion:Single equal tee with door18.84.4.1 75x75x75 mm |
| 20 | Providing and fixing on wall face unplasticised - PVCmoulded fittings/ accessories for unplasticised RigidPVC rain water, soil, waste & vent pipes pipesconforming to IS : 13592 Type A including jointingwith seal ring conforming to IS : 5382 leaving 10 mmgap for thermal expansion:Single equal tee with door18.84.4.2 110x110x110mm |
| 21 | Providing and fixing on wall face unplasticised - PVCmoulded fittings/ accessories for unplasticised RigidPVC rain water, soil, waste & vent pipes pipesconforming to IS : 13592 Type A including jointingwith seal ring conforming to IS : 5382 leaving 10 mmgap for thermal expansion:Bend 87.5°18.84.5.1 75mm |
| 22 | Providing and fixing on wall face unplasticised - PVCmoulded fittings/ accessories for unplasticised RigidPVC rain water, soil, waste & vent pipes pipesconforming to IS : 13592 Type A including jointingwith seal ring conforming to IS : 5382 leaving 10 mmgap for thermal expansion:Bend 87.5°18.84.5.2 110mm |
| 23 | Providing and fixing on wall face unplasticised - PVCmoulded fittings/ accessories for unplasticised RigidPVC rain water, soil, waste & vent pipes pipesconforming to IS : 13592 Type A including jointingwith seal ring conforming to IS : 5382 leaving 10 mmgap for thermal expansion:18.84.1 Coupler18.84.1.1 75 mm |
| 24 | Providing and fixing on wall face unplasticised - PVCmoulded fittings/ accessories for unplasticised RigidPVC rain water, soil, waste & vent pipes pipesconforming to IS : 13592 Type A including jointingwith seal ring conforming to IS : 5382 leaving 10 mmgap for thermal expansion:18.84.1 Coupler18.84.1.2 110 mm |
| 25 | 19.1 Providing and fixing Polyethelene Aluminium Polyethelene (PEALPE) Composite Pressure Pipesconforming to IS 15450 U.V. stabilized withcarbon black having thermal stability for hot &cold water supply, capable to withstand temperatureup to 800 C including all special fittings ofcomposite material (engineering plastic blend andbrass inserts wherever required) e.g. elbows, tees,reducers, couplers & connectors etc. with clamps at1.00 metre spacing. This includes testing of jointscomplete as per direction of the Engineer in charge.Internal work - Exposed on wall19.1.1 1216 (16 mm OD) pipe |
| 26 | 19.1 Providing and fixing Polyethelene Aluminium Polyethelene (PEALPE) Composite Pressure Pipesconforming to IS 15450 U.V. stabilized withcarbon black having thermal stability for hot &cold water supply, capable to withstand temperatureup to 800 C including all special fittings ofcomposite material (engineering plastic blend andbrass inserts wherever required) e.g. elbows, tees,reducers, couplers & connectors etc. with clamps at1.00 metre spacing. This includes testing of jointscomplete as per direction of the Engineer in charge.Internal work - Exposed on wall19.1.3 2025 (25 mm OD) pipe |
| 27 | Providing and fixing ball valve (brass) of approvedquality High or low pressure, with plastic floatscomplete :19.18.3 25 mm nominal bore |
| 28 | Providing and fixing uplasticised PVC connectionpipe with brass unions : 45 cm length19.21.2.1 15 mm nominal bore |
| 29 | Providing and fixing C.P. brass bib cock of approvedquality conforming to IS:893119.49.1 15 mm nominal bore |