| 1 | Construction of Recirculation Tank |
| 2 | 15.9.2Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charges:In cement mortar |
| 3 | 15.2.2Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( includingequivalent design mix) |
| 4 | 2.7.1Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock |
| 5 | 51.2.3Filling with Quarry MuckFilling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade |
| 6 | 4.3.1Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations,footings, bases for columns |
| 7 | 4.1.8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 8 | 5.9.1Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 9 | 5.2.2Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) |
| 10 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position andbinding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 11 | 13.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 12 | 13.48A.1Finishing walls with 100% Premium acrylic emulsion paint having VOC lessthan 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungalresistance, dirt resistance exterior paint of required shade (Company DepotTinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and includingpriming coat of exterior primer applied @ 0.90 litre/10 sqm. |