Tender For Repair/Maintenance Of 33/11 Kv Mrs Yard Equipment And Connected Accessories At Ima Dehradun, dehradun-Uttarakhand

Military Engineer Services-MES has published Tender For Repair/Maintenance Of 33/11 Kv Mrs Yard Equipment And Connected Accessories At Ima Dehradun. Submission Date for this Tender is 06-02-2023. Spare Part Tenders in dehradun Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

35563936
Corrigendum : Tender For Repair/Maintenance Of 33/11 Kv Mrs Yard Equipment And Connected Accessories At Ima Dehradun
Open Tender
Indian
Uttarakhand
dehradun
06-02-2023

Tender Details

Tender For Repair / Maintenance Of 33 / 11 Kv Mrs Yard Equipment And Connected Accessories At Ima Dehradun - Material And Labour For Servicing 33 Kv Yard Structure Complete Including Replacement Unserviceable Jumper, Sleeves, Vice Type Connector, Nut Bolt And Washers, Connecting Lugs / Thimble, Knife Contact, Applying Petroleum Jelly To The Moving As Well As Fixed Contacts, Tightening All The Connection For Its Smooth Functioning Preparing Old Painted Surface Of This Structure Such As Poles, Cross Arms, Bracing Supports, Clamp And Back Plate Complete Painting Of One Coat Of Anti-Corrosive Weather Proof Heat Resistant Aluminium Paints And Providing Red / Yellow And Black Paint Including Writing Sm / Mes No Or All Their Direction / Marker / Code Etc With Grey / Black Paint On Boards Etc Not Less Than 40 Mm Height 7 - 10 Mm Thick Complete All As Specified And Directed. Note: No Extra Payment Will Made For The Spares Required To Keep The Yard Structure In Satisfactory Functional State Throughout Contract Period Other Than Given In Schedule Complete All As Specified And Directed. 2 Excavation In Trenches N. Exc. 1.5 Mtr Wide And N. Exc. 1.5 Mtr In Depth In Soft / Lose Soil For Laying Cable / Taking Out Underground Cable, Gi Pipes And Bricks Laid Under Cable And Getting Out In Soft / Loose Soil Complete All As Specified And Directed. 3 Returning, Filling In Trenches Including Spreading, Leveling, Watering And Well Ramming In Layers N. Exc. 25 Cm Thick In Soft / Lose Soil After Cable / Pipes Are Laid And Tested Complete All As Specified And Directed. 4 Removing The Excavated Soil To A Distance N. Exc. 50 Mtr And Depositing Where Directed At A Level Not Exc. 1.5 Mtr Above The Starting Point Complete All As Specified And Directed. 5 Material And Labour For Sand Cushioning To Underground Cables 8 Cm Thick Before Laying The Cable And 15 Cm Thick After Laying, Stretching And Testing The Cable Complete Complete All As Specified And Directed. 6 Material And Labour For Un-Reinforced Precast Concrete Cable Cover Hv Type I, Flat Size 300 Mm X 180 Mm X 40 Mm As Protection To Underground Cable Laid Dry And Flat Adjoining Each Other Complete All As Directed. 7 Supply, Laying, Jointing And Testing Cable Xlpe Insulated Screened Pvc Bedded Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 11000 Volts Grade With Stranded Aluminum Conductor Of Cross-Sectional Area 3 Core 185 Sq Mm Including Taking Out / Down Old Existing Unserviceable Cable Complete All As Specified And Directed. 8 Supply, Laying, Jointing And Testing Cable Xlpe Insulated Screened Pvc Bedded Galvanized Steel Strip Or Wire Armored, Electric Power Cables ( Heavy Duty ) 11000 Volts Grade With Stranded Aluminum Conductor Of Cross-Sectional Area 3 Core 150 Sq Mm Including Taking Out / Down Old Existing Unserviceable Cable Complete All As Specified And Directed. 9 Supply And Fixing Of Rotating Type Air Break Isolating Switch Horizontal Mounting For Triple Pole, Mechanically Operated Mounted On Gang Operated Devices United On Insulator And Steel Frame With Operating Mechanism Worked From Ground Level For Current Rating Up To 200 Amps For 33000 Volts Complete All As Specified And Directed. 10 Supply And Fixing Of Switches Air Break, Gang Operated Triple Pole With Dropout Fuse Set 12 Insulator, Mechanically Operated, Mounted Insulator And Steel Frame With Operating Mechanism Worked From Ground Level For Current Rating Up To 400 Amps 11000 Volts Complete Including Dismantling And Taking Down Existing Unserviceable God Of Any Description Complete All As Specified And Directed. 11 Filtration / Dehydration Of Transformer Oil Through Filtration Plant To Improve The Dielectric Strength / Insulation Value Of The Transformer Oil Up To 50Kv At 2.5Mm Gap. Note : ( A ) The Contractor Will Take Shut Down Orders In Working Before Commencement Of The Work From Engineer-In-Charge. ( B ) The Contractor Shall Ensure No Wastage At Transformer Oil. ( C ) The Contractor Solely Responsible For Any Damage To The Transformer / Htocb During Filtration Operations. He Is Responsible For Making Good Any Damage To The Transformer / Htocb At His Own Cost Without Any Extra Cost To The Department. ( D ) The Contractor Shall Ensure That The Conservator Tanks Are Full To Its Level Before Starting The Dehydration. ( E ) Contractor Will Be Fully Responsible For Shift The Load Of Existing Transformer To Standby Transformer Before Taking Down For Repair. 12 Supply And Fix Disc Type Insulator Porcelain Vitreous 145 Mm Height And 255 Mm Dia Ball And Socket Type White Brown Or Green With Tension Clamp For Conductor Working Pressure 11000 Volts Complete All As Specified And Directed. 13 Supply And Fix Post Insulator 22Kv Each In Double Stake, Working Pressure 33000 Volts Grade Suitable For 33Kv Yard Including Nuts And Bolts Etc Complete All As Specified And Directed. 14 Supply, Filling And Topping Up Transformer Oil In Power Transformer At Mrs Complete All As Specified And Directed. Note: ( I ) The Transformer Oil Shall Be Type Ehv Confirming To Is 3357 Of 1983. ( Ii ) Mineral Oil Grade B Shall Be Used. ( Iii ) The Transformer Oil Should Have A High Dielectric Strength Not Less Than 60Kv. ( Iv ) Oil Should Be Brought In 209 Ltrs Sealed Container 15 Material And Labour For Cable Jointing Kit For 11 Kv ( Earthed ) Grade Cable For Indoor Termination Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 50 To 95 Sq Mm Complete All As Specified And Directed. 16 Material And Labour For Cable Jointing Kit For 11 Kv ( Earthed ) Grade Cable For Indoor Termination Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 120 To 185 Sq Mm Complete All As Specified And Directed. 17 Material And Labour For Cable Jointing Kit For 11 Kv ( Earthed ) Grade Cable For Outdoor Termination Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 50 To 95 Sq Mm Complete All As Specified And Directed. 18 Material And Labour For Cable Jointing Kit For 11 Kv ( Earthed ) Grade Cable For Outdoor Termination Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 120 To 185 Sq Mm Complete All As Specified And Directed. 19 Material And Labour For Cable Jointing Kit For 11 Kv ( Earthed ) Grade Cable For Straight Through Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 50 To 95 Sq Mm Complete All As Specified And Directed. 20 Material And Labour For Cable Jointing Kit For 11 Kv ( Earthed ) Grade Cable For Straight Through Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 120 To 185 Sq Mm Complete All As Specified And Directed. 21 Supply And Fix Danger Notice Plate Of 1.6Mm Thick Mild Steel Sheet, Vitreous Enameled White, With Letters, Figures And Conventional Skull And Bones In Diagonal Red Colour And Fixed With Ms Clamp, Bolts And Nuts Of Approved Size For Ht 25X20cm Size. 22 Taking Out / Down Unserviceable Ht Underground Cable Of Size 50 To 95 Sq Mm Of Any Description From Trenches For Fixing Straight Through / End Joint Of Any Description And Relaying / Taking Up The Same Complete All As Specified And Directed.Note: Excavation, Sand Cushioning And Bricks Shall Be Measured And Paid Separately Under Respective Items Of Schedule A. 23 Taking Out / Down Unserviceable Ht Underground Cable Of Size 120 To 185 Sq Mm Of Any Description From Trenches For Fixing Straight Through / End Joint Of Any Description And Relaying / Taking Up The Same Complete All As Specified And Directed. Note: Excavation, Sand Cushioning And Bricks Shall Be Measured And Paid Separately Under Respective Items Of Schedule A. 24 Supply And Fixing Lt Control Copper Conductor Pvc Insulated And Pvc Sheathed Round Multicore Cable 1100 Volts Grade Included Dismantling Of Existing Cable Complete All As Specified And Directed Of Following Cross Sectional Area Sizes:- 25 Size Of Cable 2.5 Sq Mm 2 Core. 26 Size Of Cable 2.5 Sq Mm 4 Core. 27 Size Of Cable 2.5 Sq Mm 8 Core. 28 Disconnecting & Taking Out Nonfunctional Ht Vcb 11 Kv 3 Phase 1250 Amp 12 Ka Of Any Make Installed At Mrs Ima Dehradun, Dismantling / Opening Of The Vcb For Servicing / Overhauling, Taking Out And Removing Unserviceable / Defective Parts Including Cleaning & Servicing, Greasing, Oiling Of The Parts Etc And Replacement Of Unserviceable Parts With New One, Reassembling The Vcb After Overhauling / Servicing And Its Testing On Full Load Complete All As Specified And Directed. Note: ( I ) The Quoted Rates Includes For Fixing The Serviceable Parts In Position And Replacement Of Unserviceable Parts With New Parts.The New Replaced Parts Shall Be Measured And Paid For Separately Under Appropriate Item Of Boq As ‘Supply Only’. ( Ii ) The Rates Quoted By The Contractor Shall Also Include The Cost Of Replacement Of Worn-Out Nuts, Bolts, Gaskets, A-Grade Greasing And Oiling Of Moving Parts And Refixing The Same. 29 Supply Only Following Spare Parts For Ht Vcb 11Kv 3 Phase 1250 Amp 12 Ka Of Make Abb, Conforming To The Respective Cat Part Given As Under Complete All As Specified And Directed.: - Note: ( I ) Fixing & Testing Element Of Following Item Is Deemed To Be Included Under Boq Item No 25 Above. ( Ii ) Quantity Of Under Mentioned Items Is Tentative And Contractor Shall Have No Claim On Account Of Variation Of Quantity Or Non-Execution Of Any Of The Item. 30 Vaccum Interrupter 11 Kv. 31 Shunt Closing Coil 110 V Dc. 32 Shunt Opening Coil 110 V Dc. 33 Spring Charging Geared Motor For 220 V 50 Hz Ac. 34 Enbloc Polycarbonate. 35 Insulating Cover Central. 36 Insulating Cover Side. 37 Tulip Contact Assembly 8 Finger. 38 Auxiliary Switch 2O 3C Silvered. 39 Auxiliary Switch 3O 2C Silvered. 40 Uni Gear 64 Pin Plug. 41 El3 Drive Complete. 42 Common Truck 12.12.40 ( P210 ) Common Truck Assembly. 43 Coil Support ( El ) ( 1Vcf339799r0271 ) Make Abb Cat Part No. 1Vcr002352g0001. 44 Supply And Fixing Relay Of Ht Vcb 11 Kv1250 Amp Having Protection Of Over Current Trip, Earth Fault Trip, Cable Arc Trip, Breaker Arc Trip, Bus Bar Arc Trip, Phase Un Balance Trip, U / V Trip, O / V Trip, Res O / V Trip, Tol Trip And Tcs Unhealthy Complete All As Specified And Directed. 45 Supply And Fixing Relay Of Ht Vcb 11 Kv1250 Amp Having Protection Of Over Current Trip, Earth Fault Trip, Cable Arc Trip, Breaker Arc, Trip Bus Bar Arc Trip, Trafo Fault Trip, Tcs Unhealthy Complete All As Specified And Directed. 46 Testing And Calibration Of 33 Kv Vcb Outdoor Type Along With Control Panel And Control Wiring, Protection System And Relays By Primary And Secondary Injection System, Battery Bank / Battery Charges / Dc System Complete All As Specified And Directed.Note- Test Certificate Shall Be Submitted To The Office In Booklet Form Duly Spiral Binding. 47 Testing And Calibration Of 11 Kv Vcb Indoor Type Along With Control Panel And Control Wiring, Protection System And Relays By Primary And Secondary Injection System Installed At 33 Kv Mrs Complete All As Specified And Directed. ( Note- Test Certificate Shall Be Submitted To The Office In Booklet Form Duly Spiral Binding. ) 48 Testing And Calibration Of 33 / 11 Kv, 3.15 Mva Outdoor Type Transformer And Control Panel -1 No Indoor Type Along With Control Wiring, Protection System Complete All As Specified And Directed. ( Note- Test Certificate Shall Be Submitted To The Office In Booklet Form Duly Spiral Binding. ) 49 Testing And Calibration Of 33 / 11 Kv, 2 Mva Outdoor Type Transformer And Control Panel -1 No Indoor Type Along With Control Wiring, Protection System Complete All As Specified And Directed. ( Note- Test Certificate Shall Be Submitted To The Office In Booklet Form Duly Spiral Binding. ) 50 Dismantling And Taking Out Existing Unserviceable Current Transformer Of Any Description And In Any Position And Supply, Installation, Commissioning And Testing Of Indoor Epoxy Type 11 Kv Transformer Having Ratio 200 / 100 / 5+ 5 Amps Having Protection Core Class Ip10, Burden Of 15 Va And Breaking Cap Of 18.4 Ka For 1.0 Second Complete All As Directed. 51 Dismantling And Taking Out Existing Unserviceable Current Transformer Of Any Description And In Any Position And Supply, Installation, Commissioning And Testing Of Indoor Epoxy Type 11 Kv Transformer Having Ratio 100 / 50 / 5+ 5 Amps Having Protection Core Class Ip10, Burden Of 15 Va And Breaking Cap Of 18.4 Ka For 1.0 Second Complete All As Directed. 52 Disconnecting And Taking Out Existing Unserviceable Lighting Arrestor Any Description And In Any Position And Supply And Fix New Lightening Arrester Non Liner Type Confirming To Is No 3070 Parts I Complete With All Fittings, Transmission Class Discharge Capacity 65 Ka Suitable For 33 Kv Including Making Connections Complete All As Specified And Directed. 53 Supply And Fixing Digital Volt Meter 11 Kv, 3 Phase Range Of Accuracy 0.5 Complete All As Specified And Directed. 54 Supply And Fixing Digital Amper Meter 11 Kv 3 Phase Range Of Accuracy 0.5 Complete All As Specified And Directed. 55 Supply And Fixing Digital Led Pilot Lights 110 Volts Dc Red / Green / Yellow / Blue Complete All As Specified And Directed. 56 Supply And Fixing Digital Hrc Fuse With Base 2 / 5 / 10 Amp Complete All As Specified And Directed. 57 Repair To Ht Vcb 33 Kv1250 Amp 25 Ka Out Door Of Make Crompton Greaves And Abb Installed At Mrs Ima Dehradun, Dismantling / Opening Of The Vcb For Servicing / Overhauling, Taking Out And Removing Unserviceable / Defective Parts Including Cleaning & Servicing, Greasing, Oiling Of The Parts Etc And Replacement Of Unserviceable Parts With New One, Reassembling The Vcb After Overhauling / Servicing And Its Testing On Full Load Complete All As Specified And Directed.Note: ( I ) The Quoted Rates Of The Contractor Include For Fixing The Serviceable Parts In Position And Replacement Of Unserviceable Parts With New Parts. ( Ii ) The New Replaced Parts Shall Be Measured And Paid For Separately Under Appropriate Item Of Boq As ‘Supply Only’. ( Iii ) The Rates Quoted By The Contractor Shall Also Include The Cost Of Replacement Of Worn-Out Nuts, Bolts, Gaskets, A-Grade Greasing And Oiling Of Moving Parts And Refixing The Same. 58 Supply Only Following Spare Parts For Ht Vcb 33 Kv 3 Phase 1250 Amp 25 Ka Of Make Abb, Conforming To The Respective Cat Part Given As Under: -Note: - ( I ) Fixing & Testing Element Of Following Item Is Deemed To Be Included Under Boq Item No 58 Above. ( Ii ) Quantity Of Under Mentioned Items Is Tentative And Contractor Shall Have No Claim On Account Of Variation Of Quantity Or Non-Execution Of Any Of The Item. 59 Vacuum Interrupter 33 Kv. 60 Spring Charging Geared Motor 33 Kv. 61 Closing Coil Assembly 33 Kv. 62 Tripping Coil Assembly 33 Kv. 63 Dismantling And Taking Out Existing Unserviceable Current Transformer Of Any Description And In Any Position And Supply, Installation, Commissioning And Testing Of Outdoor Type 33 Kv Current Transformer Having Ratio 50 / 25 / 5+5 Amps Having Protection Core Class Ip10, Burden Of 15 Va And Breaking Cap Of 18.4 Ka For 1.0 Second Complete All As Specified & Directed. 64 Dismantling And Taking Out Existing Unserviceable Potential Transformer Of Any Description And In Any Position And Supply, Installation, Commissioning And Testing Of 36 Kv Polycerate Outdoor Inductive Voltage Transformer Having Voltage 33000 / Root3 Winding-I 110 / Root3 Burden 50 Accuracy Class 0.5 And Winding - Ii 110 / Root 3 Burden 50 Accuracy Class 3 P Voltage Factor 1.2 Cont / 1.5-30 Sec Insulation Level 70 / 170 Kv Creepage Distance 900 Mm Complete All As Specified & Directed. 65 M&L For Graded Course Aggregate Of 63 Mm Grade Nominal Size Without Any Vegetation Or Chemical Including Levelling / Spreading Surrounding Ht / Lt 2 / 4 Pole Structure Lt / Ht Panel Complete All As Specified & Directed. 66 M&L For Graded Course Aggregate Of 40 Mm Grade Nominal Size Without Any Vegetation Or Chemical Including Levelling / Spreading Surrounding Ht / Lt 2 / 4 Pole Structure Lt / Ht Panel Complete All As Specified & Directed. 67 Earthing Complete Formachinery Equipment Installed At Power House / Substation With Galvanized Iron Earth Plate Electrode 600Mm X 600Mm X 6Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Metres Deep Below Normal Ground Level ) Vertically, With Top Edge Of Plate Not Less Than 1.5 Metre Below Normal Ground Level Connected To Gi Strip 32Mm X 6Mm Main Earthing Leadby Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron And Protected With 40Mm Dia Light Grade Gi Pipe All As Shown In Electrical Plate No 3 Of Mes Schedule Part-I Connecting To Earthing Test Point & To Main Switch Board Andtesting On Completion With And Including Necessary Excavation And Earth Work In Any Type Soil, Earth Lead Connected To Earth Test Point & To Main Switch Board Etc With & Including Adequate Quantity Of Charcoal Dust And Common Salt, Test Point, Pcc ( 1:3:6 ) Type C-1 ( Using 20Mm Gradedcrushed Stone Aggregate ) For Earth Pit With 40 X 40 X 6Mm Mild Steel Angle Iron Frame For Cover, Internal Surface Of Concrete Shall Be Given 10Mm Thick Plaster In Cm 1:4, Pre Cast Rcc ( 1:2:4 ) Type B-1 ( Using 20Mm Graded Crushed Stone Aggregate ) 40Mm Thick Cover, Reinforced With 8Mm Dia Deformed Or Tmt Bars 3 Nos Both Way With 12Mm Dia Round Bar Handle, Gi Medium Grade Watering Pipe 20 Mm Dia With Funnel And Wire Mesh And 40Mm Dia Gi Light Grade Earth Lead Protection Pipe Etc Complete All As Specified And Directed. 68 Material & Labour For Earth Continuity Conductor Or Main Earthing Leadgi Strip 32X6mm, Laid In Pipe / Fixed On Walls Or Any Other Position Including Jointing By Tinned Gi Nuts, Bolts And Washers In Addition To Brazing At Every Joint Complete Including Disconnecting & Taking Up Or Down Existing Unserviceable / De Shaped, Gi Earth Strip Or Taking Down Conductors Of Any Size And In Any Position, Including Making Good The Disturb Surfaces To Match With The Existing Surfaces Complete All As Specified & Directed. 69 Material And Labour For Cutting, Removing The Vegetation Growth And Surface Dressing All Around The Installation Yard / Transformer / Lt Panel Board Areas External Only To Keep Always Installation Clean And Tidy Complete All As Specified & Directed.Note: All The Installation Yards / Area Shall Be Kept Clean Through Contract Period By Repeatedly By Remaining The Grass / Shrubs As Many Time Required Depending On The Growth Of Grass Measurement Will Be Measured And Paid Only Once Throughout Contract Period. 70 Material And Labour For Painting Of Chequred Plate Surface Of Different Size, Over 10Cm In Width And Removing Existing Old Paint With The Help Of Sand / Emery Paper Etc. Preparing Both Surfaces ( Externally And Internally ) . Applying Both Side One Coat Synthetic Black Enamel Paint Over A Coat Of Red Oxide Primer, Complete All As Specified & Directed. 71 Material And Labour For Preparing Old Surface Plastered On Wall And One Coat White Washing On Old Decorated Surface Of Existing Structure Wall At Mrs Complete All As Specified & Directed.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Jan-2023 Amd2 Date 25-01-2023
2 12-Jan-2023 Amd1 BOQ 25-01-2023
3 25-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-02-2023
4 01-Feb-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-02-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

BOQ Items

Name of Work :REPAIR/MAINT OF 33/11 KV MRS YARD EQUIPMENT AND CONNECTED ACCESSORIES AT IMA DEHRADUN.
Sl. No. Item Description
1Material and labour for servicing 33 KV yard structure complete including replacement unserviceable jumper, sleeves, vice type connector, nut bolt and washers, connecting lugs/thimble, knife contact, applying petroleum jelly to the moving as well as fixed contacts, tightening all the connection for its smooth functioning preparing old painted surface of this structure such as poles, cross arms, bracing supports, clamp and back plate complete painting of one coat of anti-corrosive weather proof heat resistant aluminium paints and providing Red/Yellow and Black paint including writing SM/MES No or all their direction/Marker/Code etc with grey/Black paint on boards etc not less than 40 mm height 7 - 10 mm thick complete all as specified and directed. Note: No extra payment will made for the spares required to keep the yard structure in satisfactory functional state throughout contract period other than given in schedule complete all as specified and directed.
2Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth in soft/lose soil for laying cable/taking out underground cable, GI pipes and bricks laid under cable and getting out in soft/loose soil complete all as specified and directed.
3Returning, filling in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick in soft/lose soil after cable/pipes are laid and tested complete all as specified and directed.
4Removing the excavated soil to a distance n. exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed.
5Material and labour for sand cushioning to underground cables 8 cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable complete complete all as specified and directed.
6Material and labour for un-reinforced precast concrete cable cover HV type I, flat size 300 mm X 180 mm X 40 mm as protection to underground cable laid dry and flat adjoining each other complete all as directed.
7Supply, laying, jointing and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured, electric power cables (Heavy duty) 11000 volts grade with stranded aluminum conductor of cross-sectional area 3 core 185 sq mm including taking out/down old existing unserviceable cable complete all as specified and directed.
8Supply, laying, jointing and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armored, electric power cables (Heavy duty) 11000 volts grade with stranded aluminum conductor of cross-sectional area 3 core 150 sq mm including taking out/down old existing unserviceable cable complete all as specified and directed.
9"Supply and fixing of rotating type air break isolating switch horizontal mounting for triple pole, mechanically operated mounted on gang operated devices united on insulator and steel frame with operating mechanism worked from ground level for current rating up to 200 Amps for 33000 volts complete all as specified and directed.
10"Supply and fixing of switches air break, gang operated triple pole with dropout fuse set 12 insulator, mechanically operated, mounted insulator and steel frame with operating mechanism worked from ground level for current rating up to 400 Amps 11000 volts complete including dismantling and taking down existing unserviceable GOD of any description complete all as specified and directed.
11Filtration/dehydration of transformer oil through filtration plant to improve the dielectric strength/insulation value of the transformer oil up to 50KV at 2.5mm gap. Note : (a) The contractor will take shut down orders in working before commencement of the work from Engineer-in-charge. (b)The contractor shall ensure no wastage at transformer oil. (c)The contractor solely responsible for any damage to the transformer/HTOCB during filtration operations. He is responsible for making good any damage to the transformer/HTOCB at his own cost without any extra cost to the department. (d)The contractor shall ensure that the conservator tanks are full to its level before starting the dehydration. (e)Contractor will be fully responsible for shift the load of existing transformer to standby transformer before taking down for repair.
12Supply and fix disc type insulator porcelain vitreous 145 mm height and 255 mm dia ball and socket type white brown or green with tension clamp for conductor working pressure 11000 volts complete all as specified and directed.
13Supply and fix post insulator 22KV each in double stake, working pressure 33000 Volts grade suitable for 33KV Yard including nuts and bolts etc complete all as specified and directed.
14Supply, filling and topping up transformer Oil in power transformer at MRS complete all as specified and directed. Note: (i) The transformer oil shall be type EHV confirming to IS 3357 of 1983. (ii) Mineral oil grade "B" shall be used.(iii) The transformer oil should have a high dielectric strength not less than 60KV. (iv) Oil should be brought in 209 ltrs sealed container
15Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sq mm complete all as specified and directed.
16Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sq mm complete all as specified and directed.
17Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sq mm complete all as specified and directed.
18Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sq mm complete all as specified and directed.
19Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sq mm complete all as specified and directed.
20Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sq mm complete all as specified and directed.
21Supply and fix Danger notice plate of 1.6MM Thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in diagonal red colour and fixed with MS clamp, bolts and nuts of approved size for HT 25x20CM size.
22Taking out/down unserviceable HT underground cable of size 50 to 95 sq mm of any description from trenches for fixing straight through/end joint of any description and relaying/taking up the same complete all as specified and directed.Note: Excavation, sand cushioning and bricks shall be measured and paid separately under respective items of schedule "A".
23Taking out/down unserviceable HT underground cable of size 120 to 185 sq mm of any description from trenches for fixing straight through/end joint of any description and relaying/taking up the same complete all as specified and directed. Note: Excavation, sand cushioning and bricks shall be measured and paid separately under respective items of schedule "A".
24Supply and fixing LT control copper conductor PVC insulated and PVC sheathed round multicore cable 1100 volts grade included dismantling of existing cable complete all as specified and directed of following cross sectional area sizes:-
25Size of cable 2.5 Sq mm 2 Core.
26Size of cable 2.5 Sq mm 4 Core.
27Size of Cable 2.5 Sq mm 8 Core.
28Disconnecting & taking out nonfunctional HT VCB 11 KV 3 phase 1250 Amp 12 KA of any make installed at MRS IMA Dehradun, dismantling/opening of the VCB for servicing/ overhauling, taking out and removing unserviceable/defective parts including cleaning & servicing, greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling/servicing and its testing on full load complete all as specified and directed. Note: (i) The quoted rates includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts.The new replaced parts shall be measured and paid for separately under appropriate item of BOQ as ‘supply only’.(ii) The rates quoted by the contractor shall also include the cost of replacement of worn-out nuts, bolts, gaskets, A-grade greasing and oiling of moving parts and refixing the same.
29Supply only following spare parts for HT VCB 11KV 3 phase 1250 Amp 12 KA of make ABB, conforming to the respective cat part given as under complete all as specified and directed.: - Note: (i) Fixing & testing element of following item is deemed to be included under BOQ item No 25 above. (ii) Quantity of under mentioned items is tentative and contractor shall have no claim on account of variation of quantity or non-execution of any of the item.
30Vaccum interrupter 11 KV.
31Shunt closing coil 110 V DC.
32Shunt opening coil 110 V DC.
33Spring charging geared motor for 220 V 50 Hz AC.
34Enbloc polycarbonate.
35Insulating cover central.
36Insulating cover side.
37Tulip contact assembly 8 finger.
38Auxiliary switch 2O 3C silvered.
39Auxiliary switch 3O 2C silvered.
40Uni gear 64 pin plug.
41EL3 drive complete.
42Common truck 12.12.40 (P210) common truck assembly.
43Coil support (EL)(1VCF339799R0271) Make ABB Cat Part No. 1VCR002352G0001.
44Supply and fixing Relay of HT VCB 11 KV1250 Amp having protection of over current trip, earth fault trip, cable arc trip, breaker arc trip, bus bar arc trip, phase un balance trip, U/V trip, O/V trip, Res O/V trip, TOL trip and TCS unhealthy complete all as specified and directed.
45Supply and fixing Relay of HT VCB 11 KV1250 Amp having protection of over current trip, earth fault trip, cable arc trip, breaker arc, trip bus bar arc trip, trafo fault trip, TCS unhealthy complete all as specified and directed.
46Testing and calibration of 33 KV VCB outdoor type along with control panel and control wiring, protection system and relays by primary and secondary injection system, battery bank/battery charges/DC system complete all as specified and directed.Note- Test certificate shall be submitted to the office in booklet form duly spiral binding.
47Testing and calibration of 11 KV VCB indoor type along with control panel and control wiring, protection system and relays by primary and secondary injection system installed at 33 KV MRS complete all as specified and directed. (Note- Test certificate shall be submitted to the office in booklet form duly spiral binding.)
48Testing and calibration of 33/11 KV, 3.15 MVA outdoor type transformer and control panel -1 No indoor type along with control wiring, protection system complete all as specified and directed. (Note- Test certificate shall be submitted to the office in booklet form duly spiral binding.)
49Testing and calibration of 33/11 KV, 2 MVA outdoor type transformer and control panel -1 No indoor type along with control wiring, protection system complete all as specified and directed. (Note- Test certificate shall be submitted to the office in booklet form duly spiral binding.)
50Dismantling and taking out existing unserviceable current transformer of any description and in any position and Supply, installation, commissioning and testing of indoor epoxy type 11 KV Transformer having ratio 200/100/5+ 5 Amps having protection core class IP10, burden of 15 VA and breaking cap of 18.4 KA for 1.0 second complete all as directed.
51Dismantling and taking out existing unserviceable current transformer of any description and in any position and Supply, installation, commissioning and testing of indoor epoxy type 11 KV Transformer having ratio 100/50/5+ 5 Amps having protection core class IP10, burden of 15 VA and breaking cap of 18.4 KA for 1.0 second complete all as directed.
52Disconnecting and taking out existing unserviceable lighting arrestor any description and in any position and supply and fix new lightening arrester non liner type confirming to IS No 3070 parts I complete with all fittings, transmission class discharge capacity 65 KA suitable for 33 KV including making connections complete all as specified and directed.
53Supply and fixing digital Volt meter 11 KV, 3 phase range of accuracy 0.5 complete all as specified and directed.
54Supply and fixing digital Amper meter 11 KV 3 phase range of accuracy 0.5 complete all as specified and directed.
55Supply and fixing digital LED Pilot lights 110 Volts DC Red /Green/Yellow/Blue complete all as specified and directed.
56Supply and fixing digital HRC Fuse with base 2/5/10 Amp complete all as specified and directed.
57Repair to HT VCB 33 KV1250 Amp 25 KA out door of make Crompton Greaves and ABB installed at MRS IMA Dehradun, dismantling/opening of the VCB for servicing/overhauling, taking out and removing unserviceable/defective parts including cleaning & servicing, greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling/servicing and its testing on full load complete all as specified and directed.Note: (i) The quoted rates of the contractor include for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. (ii) The new replaced parts shall be measured and paid for separately under appropriate item of BOQ as ‘supply only’. (iii) The rates quoted by the contractor shall also include the cost of replacement of worn-out nuts, bolts, gaskets, A-grade greasing and oiling of moving parts and refixing the same.
58Supply only following spare parts for HT VCB 33 KV 3 phase 1250 Amp 25 KA of make ABB, conforming to the respective cat part given as under: -Note: - (i) Fixing & testing element of following item is deemed to be included under BOQ item No 58 above. (ii) Quantity of under mentioned items is tentative and contractor shall have no claim on account of variation of quantity or non-execution of any of the item.
59Vacuum interrupter 33 KV.
60Spring charging geared motor 33 KV.
61Closing coil assembly 33 KV.
62Tripping coil assembly 33 KV.
63Dismantling and taking out existing unserviceable current transformer of any description and in any position and Supply, installation, commissioning and testing of outdoor type 33 KV Current Transformer having ratio 50/25/5+5 Amps having protection core class IP10, burden of 15 VA and breaking cap of 18.4 KA for 1.0 second complete all as specified & directed.
64Dismantling and taking out existing unserviceable potential transformer of any description and in any position and Supply, installation, commissioning and testing of 36 KV polycerate outdoor inductive voltage transformer having voltage 33000/root3 winding-I 110/root3 burden 50 accuracy class 0.5 and winding - II 110/root 3 burden 50 accuracy class 3 P voltage factor 1.2 cont/1.5-30 Sec insulation level 70/170 kv creepage distance 900 mm complete all as specified & directed.
65M&L for graded course aggregate of 63 mm grade nominal size without any vegetation or chemical including levelling /spreading surrounding HT/LT 2/4 pole structure LT/HT panel complete all as specified & directed.
66M&L for graded course aggregate of 40 mm grade nominal size without any vegetation or chemical including levelling /spreading surrounding HT/LT 2/4 pole structure LT/HT panel complete all as specified & directed.
67Earthing complete formachinery equipment installed at power house/substation with galvanized iron earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to GI strip 32mm X 6mm main earthing leadby means of bolts, nuts, check nuts and washers of galvanised iron and protected with 40mm dia light grade GI pipe all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board andtesting on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm gradedcrushed stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4)type B-1 (using 20mm graded crushed stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 40mm dia GI light grade earth lead protection pipe etc complete all as specified and directed.
68Material & Labour for Earth continuity conductor or main earthing leadGI strip 32x6mm, laid in pipe/fixed on walls or any other position including jointing by tinned GI nuts, bolts and washers in addition to brazing at every joint complete including disconnecting & taking up or down existing unserviceable /de shaped,GI earth strip or taking down conductors of any size and in any position, including making good the disturb surfaces to match with the existing surfaces complete all as specified & directed.
69Material and labour for cutting, removing the vegetation growth and surface dressing all around the installation yard/transformer/LT panel Board areas external only to keep always installation clean and tidy complete all as specified & directed.Note: All the installation yards/area shall be kept clean through contract period by repeatedly by remaining the grass/shrubs as many time required depending on the growth of grass measurement will be measured and paid only once throughout contract period.
70Material and labour for painting of Chequred plate surface of different size, over 10cm in width and removing existing old paint with the help of sand/emery paper etc. Preparing both surfaces (externally and internally). Applying both side one coat synthetic black enamel paint over a coat of red oxide primer, complete all as specified & directed.
71Material and labour for preparing old surface plastered on wall and one coat white washing on old decorated surface of existing structure wall at MRS complete all as specified & directed.