Tender For Provision Of Certain Rw, Mw And Lbw Under Ge ( Awc ) Mhow. -Exavation In Post Hole Or Smilar Hoels Each N Exe 0.5 Cum, Getting Out Removing Surplus Soil To A Distance N Exe 50 M, Complete All As Specified And Directed. 2 Surface Excavation N. Exc 30 Cm Deep And Averaging 15Cm Deep And Getting Out In Any Type Soil, Complete All As Specified Directed. 3 M & L For Brick Work With Fly Ash Bricks, Modular Brick, Straight Or Curved On Plan Exc 6 M Mean Radius, Built In Cm 1:6, Complete All As Specified And Directed. 4 M & L 15 Mm Thick Rendering In Cement Mortar 1:4 On Brick Work Or Concrete Surface On Wall Or Ceiling As In Fins Fascias, Chajja Louveres, Parapets And Railing Exc 60 Cm In Height Newels , Balustrade With Chicken Wire Mesh In Two Layer Of Plaster And Finished Even And Smooth Without Using Extra Cement, Complete All As Specified And Directed. 5 M&L For Preparation Of New Surface Of Wall / Ceiling And Applying Three Coat Of White Wash, Complete All As Specified And Directed. 6 S & F Joist, Channel, Angle Or Tee, Square Or Rectangular, Tubler Sections, Fixed Indipendenty Or As Purlin, Rafter, Or Post Including Cutting To Dead Length Where Required, Notching, Drilling, Fitting, Riveting And / Or Welding Or Connecting With Boldts, Complete All As Specified And Directed. ( Fe-410-W ( Gde-E-250 ) Quality A ) , Complete All As Specified And Directed. 7 M & L For Preparing New Steel Surfaces Of Any Description, Over 10Cm In Width Or Girth, Not Otherwise Describe And Evenly Applying Two Coats Of Synthetic Enamel Paint Over One Coat Of Red Oxide Primer, Complete All As Specified And Directed. 8 S & F Pre-Painted Galvalum Aluminium Zinc Coating Steel Based Corrugated Steel Sheet 0.50Mm Thick ( Total Coated Thickness ) Of Any Colour Having Tensile Strength Of 550 Mpa Minimum, Yeild Strength, It Shall Becoated With Hot Dip Alloy Of 55% Aluminimum, 43.5% Zinc, 1.5% Silicon And Finished With Resin Coat On Both Surface @ 150 Gm / Sqm Of Coating As Specified And Shall Be Fixed With Hot Dip Galvanised, Self Drilling And Self Tapping Screws Neoprened And Edpm Washers As In Roof Covering, Complete All As Specified And Directed. 9 S & F Solid Pvc Wall / Ceiling Lining Consisting Of 5Mm Thick Plain Colour Pvc Sheet Inclusive Of Solvent Cement And Fixing At Site On Pvc Frame Including Dismantling, Complete All As Specified And Directed. 10 S&F Gi Frame Work For Seamless Ceiling Comprises Of Gi Perimeter Channel 0.55 Mm Thick With Two Unequal Flanges Of 20 And 30 Mm And Web Of 27 Mm Fixed To Surrounding Wall Using Nylon Sleeves And Screws At 450 Mm Center To Center Channel 0.9 Mm Thick Having Two Unequal Flanges Of 15 Mm Each And Web Of 45 Mm Suspended From Soffit Approx 900 Mm Center To Center With Gi Cleat And Steel Expansion Fastener With And Including Ceiling Section Of 0.55 Mm Thickness Having Kurled Web Of 50 Mm And Flanges Of 26 Mm Each With Lips Of 10.5 Mm Fixed To Intrermediate Channel With Connecting Clips Across The Intermediate Channel At 457 Center To Center, Complete All As Specified And Directed. 11 M & L Providing Precast Cement Concrete Louvers And Jallies 50 Mm Thick Of Any Size As Approved By Ge Including All Mouldings , Frame Etc, Complete All As Specified And Directed. 12 S&F For Tmt Reinforcement Bars 6-8 Mm Dia Including All Cutting Bending Binding Cranking Placing & Binding With Ms Wire ( Annealed ) Not Less Than 0.9 Mm Dia, Complete All As Specified And Directed. 13 S&F For Tmt Reinforcement Bars 10 Mm Dia And Over Including All Cutting Bending Binding Cranking Placing & Binding With Ms Wire ( Annealed ) Not Less Than 0.9 Mm Dia, Complete All As Specified And Directed. 14 S&F Pre-Painted Galvalume Aluminium Zinc Coating Steel Based Plain Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof / Covering / Cladding To Wall, Fixed With Self Tapping Screws, Complete All As Specified And Directed. 15 S & F In Repair110 Mm Dia Bore. Pvc ( Swr ) Pipes Single Socketed In Any Length Withrubber Ring Joints, Fixed To Walls, Complete All As Specified And Directed. 16 S & F In Repair 110 Mm Dia Bore Pvc ( Swr ) Bends Any Radius With Solvent Rubber Ring Joints, Fixed, Complete All As Specified And Directed 17 S & F In Repair110 Mm Dia Bore Pvc ( Swr ) Junction Single, Single ( T ) Equal Or Unequal With Solvent Rubber Ring Joints, Fixed, Complete All As Specified And Directed 18 S&F Reienforced Cement Concretetype B0 1:2:4 Beam, Cantilever, Bressummers, Lintels Over 1.5 M Span, Complete All As Specified And Directed 19 Use And Waste Of Formwork To Sides And Soffits Of Floor Or Roof Beam , Beam Haunching , Griders Bressummers Lintels Cantilevers Sup Ports Overhanhgs Coloumn Etc Also Splays Between Floor And Beam For Fair Finished Surface Of Concrete, Complete All As Specified And Directed 20 Demolition Of Reinforced Cement Concrete Of Any Descriptionetc, Complete All As Specified And Directed. 21 Demolition Of Brick Work Built In Cement Mortar Including All Quoins Arches Pillars Etc, Complete All As Specified And Directed. 22 M&L For Pcc ( 1:3:6 ) Type C-1 With Using 20Mm Graded Stone Aggregate As In Plinth Protection, Bed Blocks, Coping, For Fixing Holdfast / Lugs, Filling Hollow Space Of Pressed Steel Door Frame Etc Including Necessary Form Work , Complete All As Specified And Directed. 23 Desmantling Ofplain Or Corrugated Steel Sheeting, Any Gauge, Thickness, Including Nainital Or Similar Pattern Roof Coverings, Complete All As Specified And Directed. 24 Excavating Over Areas, Not Exceeding 1.50 M Deep And Getting Out In Any Type Of Soil Complete All As Specified And Directed. 25 M & L For Cement Concrete 1:4:8Type D-2 ( 40 Mm Graded Aggregate ) As In Sub Base, Foundations, Filling And Mass Concrete, Complete All As Specified And Directed. 26 M & L 25Mm Thick Cement Concrete Type B-0, 1:2:4 ( 12.5 Mm Graded Aggregate ) As In Levelling Course In Floor Complete All As Specified And Directed. 27 M&L Endura 300X300 Vitrified Full Body Tiles 12 Mm Th With Water Absorption <0.5%, Average Mor> 38 N / Sqmm, Breaking Strenth >300 N, Thermal Shock Resistance No Damage, Skid Resistance Ramp Test >R9 Alable Color, 1St Quality / Premium In Flooring & Including 20 Mm Thick Screed Bed Built In Cm 1:4, Complete All As Specified And Directed. 28 M&L Granite 20 Mm Thick ( Of Any Type ) Work ( Table Rubbed And Polished ) In Steps, Jambs, Pillars, Window-Cills, Cooking Plateforms And Likeincluding Pointing In White Cement ( 1:2 ) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite Over & Incl 20 Mm Thick Screed Bed Built In Cm 1:4, Complete All As Specified And Directed. 29 Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M-25 Grade Cement Concrete In Position To The Required Line, Level And Curvature, Jointed With Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Including Making Joints With Or Without Grooves ( Thickness Of Joints Except At Sharp Curve Shall Not To More Than 5 Mm ) , Including Making Drainage Opening Wherever Required, Complete All As Specified And Directed. 30 M&L Providing Cement Concrete 1:2:4 Type B-0 ( Using 12.5 Mm Graded Crushed Stone Aggregate As In Lintels Upto 1.50 Metre Clear Span, Cills, Steps, Seismic & Other Similar Bands, Plinth Courses, Parapets & Railing Upto 60 Cm In Height, Copings, Kneelers, Apex Stones, Bed Plates, Kerbs And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating As Directed Including Necessary Form Work, Complete All As Specified And Directed. 31 Removing Excavated Material N Exc. 50M And Depositing Where Directed At A Level N Exc 1.5 M Above The Starting Point, Complete All As Specified And Directed. 32 Desmantling Of Framed Timber Scantlings 40 Sq Cm And Over In Section, In Any Position, Complete All As Specified And Directed. 33 Excavating In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth; For Laying Of Cable Etc.N Exc 1.5 M In Depth And Getting Out In Any Type Of Soil, Complete All As Specified Directed. 34 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25 Cm, Complete All As Specified Directed. 35 Supplying And Laying Un-Reinforced Precast Concrete Cable Cover, Class Lv, Type I, Flat, Size 250 Mm X 150Mm X 40Mm, Complete All As Specified Directed. 36 Supply And Laying Fine Sand For Cable Protection In Layers Including Punning, Complete All As Specified Directed.Note:- Punned Thickness Shall Be Measured For The Payment. 37 M&L For Tubes, Medium Grade, Galvanised, With All Fitting Of Size 50 Mm ;Laid In Trenches For Cable Protection All As Specified And Directed 38 Supply And Laying And Testing Cable Xple Insulated, Screended , Pvc Badded Galvanised Steel Strip Or Wire Armoured Electric Power Cable ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of25 Sqmm4 Core, Complete All As Specified Directed. 39 Supply And Installation And Commissioning Lt Panel Board Out Door Type , Double Door Type Made Out Of Crca Sheet 3 Mm Thick For Outdoor Frame And 2 Mm Thick For Innner Frame With400 Amps Rated Aluminium Bus Bar , Cubical Type Duly Powder Coated With Two Coat Of Synthetic Enamel Paint Over A Coat Of Mettalicprimer, Incl Necessary Pcc Work For Grounting Of Feeder Box 40 Cm Above The Ground Level By Providing 60 Cm Long Angle Iron Frame Bottom Of 40X40x5 Mm Thick , Welded On All Four Corners , Embedded In Pcc 1:2:4 Type B-L Complete With Comprising The Following Complete With Panel Wiring Suitable Size Of Copper Wire.Note:- The Panel Should Be Cpri Approved.Incoming:- ( A ) Mccb Tpn 63Amps, 415 Volts -1 Nos, Ics=100% Icu, ( B ) Ammeters 0-100 Amps With Ct Reting And Selector Switch -01 No ( C ) Voltmeter With Selector Switch 0-500 Volts -01 No ( D ) Indicatin Led Lamps Ryb ) -0I Setoutgoing:- ( A ) Mcb Tpn 63Amps, 415 Volts -4Nos ( B ) Mcb Spn 32 Amps , 415 Volts-03 Nos 40 M&L Hardcore Of Gauge N Exc. 63 Mm, Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rammed To A True Surface, Complete All As Specified Directed. 41 M & L 60Mm Thick Machine Pressed Precast Concrete Interlocking Paver Block Fixing With Grey Cement And Pigmentsof I Shape Or As Approved By Ge, And Any Colour And Size Confirming To Is 15658-2006 Of M-35 Grade Set, Laid Over And Including 25 Mm Thick Dust Sand Cushioning, Filling Of Joints With Sand & Compaction Using Surface Vibrator After Filling Of Joints Laid In Any Pattern As Decided By Engineer-In-Charge Including Packing Of Sides By Cement Concrete Finishing Surfce Even And Smooth, Complete All As Specified And As Directed. 42 Earth Work In Excavation Of All Kind Of Soil By Mechanical Means ( Hydraulic Excavator ) Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M, Complete All As Specified And As Directed. 43 Earth Work In Excavation Of All Kind Of Soil By Mechanical Means ( Hydraulic Excavator ) / In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M, Complete All As Specified And As Directed. 44 Description Same As Per Item No. 43.00 But Each Additional 1.5 M Or Part Thereof In Depth Beyond The First 1.5 M, Complete All As Specified And As Directed. 45 Removing Excavated Material N Exc. 50M And Depositing Where Directed At A Level N Exc 1.5 M Above The Starting Point, Complete All As Specified And As Directed. 46 M&L For Rcc ( Design Mix ) M25 ( 20 Mm Graded Aggregates ) Asin Foundations, Including Rafts, Footings, Foundation Beam, Plinth Beams, Bases For Columns, Etc, Basement Slabs, Under Reamed Piles And Mass Concrete, Complete All As Specified And As Directed. 47 M&L For Rcc ( Design Mix ) M25 ( 20 Mm Graded Aggregates ) As In Columns, Pillars, Peirs, Posts, And Struts, Complete All As Specified And As Directed. 48 M&L For Rcc ( Design Mix ) M25 ( 20 Mm Graded Aggregates ) As In Beams , Cantilivers , Bressummers , Lintles Over 1.5 M Span Complete All As Specified And Directed. 49 M&L Rcc M-25 ( Design Mix ) Using 20Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams, And Columns Complete All As Specified And Directed. 50 M&L Rcc M-25 ( Design Mix ) Using 20Mm Graded Stone Aggregate As Chajjas Complete All As Specified And Directed. 51 Use And Waste Of Formwork To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beam, Sides And Soffits ( If Any ) Of Foundation And Plinth Beams And Similar Work, Verticalor To Batter Surfaces For Rough Finished Flat Surfaces Of Concrete, Complete All As Specified And Directed. 52 Use And Waste Of Formwork Rough Finished Surface Of Concrete As In Square, Rectangular Or Polygonal To Sides Of Columns, Pillars, Posts, Struts, Piers Etc.Complete All As Specified And Directed. 53 M&L Form Work To Soffits Of Suspended Slabsuch As Roof Slabs, Floor Slabs, Landings And Similar Work Not Exceeding 200Mm Thick ( Horizointal Or Slooping ) Complete All As Specified And Directed. 54 M&L Formwork To Chullah Hoods, Chajjas, Troughs And Similar Items Including Edges Complete All As Specified And Directed. 55 M&L Form Work To Edges Of Concrate Flats, Treads, Breaks In Floors, Androof N.Exc 20 Cm Wide And Sides Of Rcc / Pcc Bands In Walls Horizontal Or Sloping And Similar Work Exc 10 Cm But Not Exc 20 Cm Wide Complete All As Specified And Directed. 56 S&F For Tmt Reinforcement Bars 5 Mm Dia Including All Cutting Bending Binding Cranking Placing & Binding With Ms Wire ( Annealed ) Not Less Than 0.9 Mm Dia Over Upto And Including 10Mm Dia In Stirrups, Spacers And Binders Etc, Complete All As Specified And Directed. 57 M&L Brick Work With Fly Ash Modular Bricks Straight Or Curved On Plan To Any Radius In Half Brick Thick Walls, Built In In Cement Mortar 1:3 Complete All As Specified And Directed. 58 M & L 40 Mm Thick Damp Proof Course In Cement Concrete 1:2:4 Type B-0 With Incorporating Integral Water Proofing Compound In The Manner Specified By The Manufacturer And In The Proportions Indicated, To Horizontal Or Vertical Surfaces Including Necessary Formwork Complete All As Specified And Directed. Note:- Wpc Will Be Measured And Paid Separately. 59 M & L Rendering 10 Mm Thick On Brick Wall / Cement Block Wall Or Concrete Surfaces In Cement Mortar 1:6, Surfaces Finished Even And Smooth Without Using Extra Cement , Complete All As Specified And As Directed. 60 M & L 5 Mm Thick Rendering In Cement Mortar 1:3 On Concrete Surfaces As In Ceiling Surface Finish Even And Smooth Without Using Extra Cement , Complete All As Specified And Directed. 61 M & L Plastering15 Mm Thick Intwo Layers Of10 Mm Thick Inbottom And 5 Mm Thick With Wpc Oftop Layerin Cement Mortar 1:4 On Brick Wall / Cement Block Wall Or Concrete Surfaces, Surfaces Finished Even And Smooth Without Using Extra Cement , Complete All As Specified And As Directed. Note:- Wpc Will Be Measured And Paid Separately. 62 Supply Only Liquid Water Proofing Compound All As Specified And Directed. 63 M & L Preparation Of New Wall Surface And Apply One Two Of White Wash On Wall Surface Includingwashing Floors, Cleaning Glass, Joinery, Electrical Fittings, Wiring Etc. , Of Drops And Splashes Complete All As Specified And Directed. 64 M&L Forapplying 1 Mm Thick Wall Care Putty On Wallon Internal Old / New Wall Surfaces As Per Manufacturerer Instruction Complete All As Specified And As Directed 65 M & L For Applying Two Coats Of Oil Bound Distemper Over A Coat Of Alkali Resistant Primer On Prepared Wall Putty Surfaces Of Internal Wall All Includingwashing Floors, Cleaning Glass, Joinery, Electrical Fittings, Wiring Etc. , Of Drops And Splashes Complete All As Per Specified And Directed. 66 M&L Preparing Of Newly Plastered Or Unplastered Surfaces Of Walls, Cornices Etc And Applying Two Coats Of Cement Base Paint Over One Coat Of Cement Primer, Complete All As Specified & Directed. 67 M&L Moorum / Red Bajri Filling In Floors Or Pavings, Laid In Layers N Exc. 15 Cm Thick, Spread, Levelled And Rammed Including Watering Complete All As Specified And Directed. 68 M & L 20 - 25 Mm Thick Machine Cut Kota Stone Slab In Flooring Or Treads Of Steps Over And Including 20Mm Thick Screed Bed In Cement Mortar 1:4, Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match With Shade Of Slab Including Rubbing Complete All As Specified And As Directed.Note:- The Size Of Kota Stone Slab Shall Not Less Than 550 Mm X 550 Mm Cut Size, Except The Location Where The Balance Portion Remain Less Than Size As Specified Above. 69 Description Same As Per Item No. 68.00 But As In Riser Of Steps, Skirting, Dado And Vertical Surfaces Including 10 Mm Thick Rendering In Cm 1:4, Complete All As Specified And Directed. 70 S & F Framed Work Such As Grills, Gratings, Etc.. With Ends Of Bars Shouldered And / Or Riveted, Or Forged Into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework Of Water Tanks And Similar Work Conforming To Fe.290.Gde-E-165, Complete All As Specified And Directed. 71 S & F Powder Coated Aluminium Sliding Glazedwindows With Three Track Shutter Sliding ( Two Shutters Glazed And One Shutterwire Mesh ) Shall Be Following Specification, Complete All As Specified And Directed. ( I ) Windows Frame Of Cross Section 101Mm X 44Mm X 1.5Mm Thick. ( Ii ) Three Way Track For Sliding Shutters Of Cross Section91.8Mm X 31.75Mm X1.1Mm Thick. ( Iii ) Sliding Shutter Frame Of Cross Section40 X 18 X 1Mm Thick. ( Iv ) 4 Mm Thick Tintedglass Superior Quality. ( V ) Idpe Rubber Guasket For Fixing Of Glass. ( Vi ) Locking Cleats Per Shutter -01 Nos. ( Vii ) Sliding Rollers Per Shutter - 02 Nos. ( Viii ) Aluminium Wire Cloth 0.30Mm Nominal Dia Of Wire And Average Width Of Aperture 1.56Mm For Shutters 01 Nos. 72 S&F Powder Coated Aluminium Ventilator Cross Section 63.5X38.10X1.5Mm Consisting Of Two Partions Upper Portion Shall Have Louvers With 3Mm Thick Pin Headed Glass And Aluminium Wire Cloth 0.30Mm Nominal Dia Of Wire And Average Width Of Aperture 1.56M Fixed With Aluminium Beads And Securing On Outer Face Of Frame And Lower Portion Of Ventilation Shall Be Fixed With 3Mm Thick Pin Headed Glass With Idpe Rubber Gasket Including Aluminium Beads, Including Preparation Of Jombs All Around In Cm 1:3 Finishing Even And Smooth Complete All As Specified And Directed. 73 Cutting Holes In Brick Walls Built In Cement Mortar For Inserting Holdfasts And Making Good Dismantled Portion In Cement Mortar 1:3 Or Cement Concrete 1:2:4 Type B-1, Complete All As Specified And Directed. 74 S&F Pressed Steel Frames Size 125X60 Mm For Doors With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete All As Specified And Directed. 75 S&F2nd Class Hard Wood 35 Mm Thick Plain, Framed, Pannelled Shutters ( Any Number Of Panels ) , With Panels Of Timber Flat On Both Sides ( Feather Edged ) , Or Of Veneered Particle Board Medium Density, Wood Particle Board With Commercial Face Veneers, Complete All As Specified And Directed. 76 S&F2nd Class Hard Wood 35 Mm Thick Glazed And Skelton Shutters, Open Rebated And Prepared To Receive Glass, Gauze Etc, ( Without Sash Bars ) , Edges Of Framing Plain, Chamfered Or Rounded Fitted With Cut And Mitred Beads For Securingglass, Etc, Size Of Members Of Shutters As Specified In Ssr Part I, Section 8, Clause8.24 ( A ) Complete All As Specified And Directed.Note :- Glass Pane And Wire Mesh Shall Be Measured And Paid Separately Inrespective Supply Only Item. 77 Supply Only Galvanised Mild Steel Wire Cloth, 0.56Mm Nominal Dia Of Wire And Average Width Of Aperture 1.00Mm And Fixed With Tinned Tacks, Or Galvanised Wire Staples Complete All As Specified And Directed. 78 M & L Preparation Of New Or Previously Untreated Wood And Wood Based Surfaces Of Any Description, Not Otherwise Description, Over 10 Cm Width Or Girth Apply Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer Complete All As Specified And Directed. 79 S&F Factory Made Solid Pvc Door Frame Of Size 50 Mm X 47 Mm Made Out Of 5 Mm Plain Colour Pvc Sheet Reinforced With Ms Square Tube, All As Specified And Directed. 80 S&F 30 Mm Thick Factory Made Solid Panel Pvc Door Shutter ( Style ) Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thick & Size 19Mmx19mm For Stiles And 15Mmx15mmfor Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Red Oxide Primer Of Approval Make And Shall Becovered With 5 Mm Thick Heat Moulded Plain Colour Pvc ‘C’ Channel Of Size 30X50mm Forming Stiles And 5 Mm Thick Wide Pvc Sheets For Top Rail , Lock Rail And Bottom Rail On Either Side And 10 Mm ( 5Mmx2mm ) Thick Having A Pvc Sheet Strip Of 20Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Plain Colour 5Mm Thick Pvc Sheet To Be Fitted In The M.S. Frame Welded / Sealed To The Stiles & Rails With 30 Mm Widex5 Mm Thick Pvc , Sheet Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement On Either Side, And Additional 5 Mm Thick Pvc Stripes Of 20 Mm Width Is To Be Struck On Interior Side Of C Channel Using Pvc Solvent Adhesive Complete At Site As Per Specification Complete All As Specified And As Directed. 81 S&F Aluminium Anodised Barrel Tower Bolts 150 Mm Long Of Extruded Section And Fixed Complete All Specified And Directed. 82 S&F Aluminium Anodised Barrel Tower Bolts 200 Mm Long Of Extruded Section And Fixed Complete All Specified And Directed. 83 S&F Aluminium Handles, Size 150 Mm Cast Type, Anodised Complete All As Specified And Directed. 84 S & Fbutt Hinges, Size 100 Mmtype C-21 Extruded Aluminium Alloy With Galvanised Mild Steel Hinge Pin, Anodised Isi Marked, Complete All As Specified And Directed. 85 S&F 250 Mm Long Aluminium Alloy, Anodised Sliding Door Bolt With Hasp, Staple ( Bolt Type ) And Fixing Clips Of Sheet, Cast Of Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Section Or Cast Aluminium Alloy Fixed, Complete All As Specified And Directed. 86 S & F Vitreous China Squatting Pan Orissa Patern Size 580 Mm X 440 Mm, White, With Integral Foot Rest ( Excluding Flushing Cistern And Flush Pipe ) Including Connection To Trap And To Flushing Pipe, Anti-Syphonage Pipe, Etc Complete All As Specified And Dircted. 87 S & F 10 Litres Capacity Pvc Low Level Cistern ‘ White’ With Inlet, Float Valve And Handle Including Flushing Pipe Of Pvc 32 Mm Dia And Connection To Pipes Complete All As Specified And Directed. 88 S & F Chromium Plated Fancy Type Stop Cock / Angle Cock 15 Mm Dia Cast Copper Alloy Screwed Down, High Pressure, With Crutch Or Butter Fly Handle Screwed Both Ends For Iron Pipeor For Unions And Fixed, Complete All As Specified & Directed. 89 S & F Pvc Connection 15 Mm Dia 600 Mm Long With Ptmt Nuts At Both Ends Complete All As Specified And Directed. 90 S & F 15 Mm Bore Bib Taps Chromium Plated Fancy Type Cast Copper Alloy Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule, And Fixed Complete All As Specified And Directed. 91 S & F Vitreous China Wash Hand Basin White Or Any Colour , Flat Back Of Size 550Mmx400mm Fixed On And Including Cast Iron Cantilever Bracket, 32Mm Dia Brass Waste Coupling And 32 Mm Dia Pvc Waste Pipe Complete All As Specified And Directed. 92 Supply Only 15 Mm Dia Bore Fancy Type Chromium Plated Pillar Tap, Cast Copper Alloy, With Capstan Heads, Screwed Down High Pressure With Long Screwed Shanks And Fly-Nuts, Screwed For Iron Pipe And Fixed, Complete All As Specified And Directed. 93 S&F 600Mmx450mm Bevelled Edge Looking Mirror Of Selected Quality Glass, Mounted On 6 Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden / Pvc Plugs With Chromium Plated Brass Screws And Cup Washer 94 S & F Brass Chromium Plated Tubular Towel Rail, 20Mm Dia D Type 60 Cm Long Between Flanges Complete All As Specified. 95 S & F Vitreous China Bowl Urinal Flat Back, Size, Of 465 X 355 X 265 Mm White ( Minimum ) , With Grating And Union For Discharge Pipe Complete All As Specified And Directed. 96 S&F Pvc ( Swr ) 75 Mm Bore Pipes Single Socketed In Any Length With Rubber Ring Joints With Solvent Cement Fixed To Walls&Flooor Incluidng Clamping Complete All As Specified And Directed. 97 S & F In 75 Mm Bore Pvc ( Swr ) Bends Any Radius With Solvent Rubber Ring Joints, Fixed, Complete All As Specified And Directed. 98 S & F In 75 Mm Bore Pvc ( Swr ) Junction Single, Single ( T ) Equal Or Unequal With Solvent Rubber Ring Joints, Fixed, Complete All As Specified And Directed 99 S & F Pvc ( Swr ) Nahani Trap / Floor Trap With Grating Having Diameter Of Outlet 75 Mm Including Jointing To Waste Pipe With Solvent Cement Complete. 100 S & F110 Mm Bore Pvc ( Swr ) Vent Cowl Including Taking Out Existing Unserviceable Cowl, Complete All As Specified And Directed. 101 S & F Of Cpvc 20 Mm Outer Dia Pipessdr 11 & Plain Cpvc Sdr 11 Fittings On Walls / Ceiling Or Laying In Floors, Complete All As Specified And Directed. 102 S & F Of Cpvc 25 Mm Outer Dia Pipessdr 11 & Plain Cpvc Sdr 11 Fittings On Walls / Ceiling Or Laying In Floors, Complete All As Specified And Directed. 103 S & F Of Cpvc Brass Elbow ( 3 / 4 X ½ ) For 20 Mm Outer Dia Cpvc Pipe Complete All As Specified And Directed. 104 S & F Of Cpvc Male Brass Threaded Adaptor ( Mta / Mbta ) For 25 Mm Outer Dia Pipe Complete All As Specified And Directed. 105 S & F Of Cpvc Ball Valve For 25 Mm Outer Dia Pipe Complete All As Specified And Directed. 106 S&F Rotational Moulded Poly-Ethylene Water Storage Tanks ( Isi Marked ) ( Cylinderical Vertical With Closed Top ) 1000 Litres Capacity , Hoisted And Fixed In Position Including Dismantling Of Pvc Water Tanks Exc 500 Ltr But Not Exc 1000 Ltr, Complete All As Specified And Directed. 107 S&F Ball Valves High Pressure Of Ptmt With Epoxy Coated Aluminium Rod & High-Density Plastic Ball , Suitable For 25 Mm Bore Pipe, Screwed For Iron Pipe And Fixed. . ( Minimum Weight 25Mm-455 Gms. ) Complete All As Specified And Directed. 108 M & L Non Skid Ceramic Coloured Tiles 7 To 8 Mm Thick ( Square / Rectangular ) Area Of Each Tile Exceeding 0.11 Sqm But Not Exc 0.18 Sqm , In Floors Etc.Set Jointed In Neat Cement Sluury And Pointed In White Or Coloured Cement To Match Over & Incl 15 Mm Thick Screed Bed Built In Cm 1:6, Complete All As Specified And Directed 109 M&Lglazed Ceramic Coloured Tiles On Vertical Surfaces 450X350x7 Mm / 450X300x7mm Thick Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match Over And Including 10Mm Thick Backing Coat To Receiving To Wall Tiles Incement Mortar 1:4, Complete All As Specified And Directed. 110 M&L Granite 20 Mm Thick ( Of Any Type ) Work ( Table Rubbed And Polished ) In Steps, Jambs, Pillars, Window-Cills, Cooking Plateforms And Likeincluding Pointing In White Cement ( 1:2 ) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite Over & Incl 20 Mm Thick Screed Bed Built In Cm 1:4, Complete All As Specified And Directed. 111 M&L Rounding To Edges Of Stone Slabs One Edges, Such As In Steps, Cooking Platform, And Other Similar Situations For Bullnosing / Moulding To Exposed Edges ( Any Type ) And Polishing To Match The Adjoining Surfaces, Complete All As Specified And Directed. 112 S & F Tubular Rolled Sections As Post, Rafter, Purlin, And Its Connected Wk For Shed Structure And Similar Work Complete Using Erw Or Induction Butt Welded Tubes Conforming To I.S. 1161-1976 Grade St.-240, Complete All As Specified And Directed. 113 S & F Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Sun Shade, Roof Covering / Cladding To Wall, And Similar Work Fixed With Self Tapping Screws Complete All As Specified And Directed. 114 M&L Water Proofing Treatment On Non Approachable / Non Accessible Roof Surface ( Horizontal & Vertical Surfaces ) In Following Sequence Through Authorized Applicator Of The Manufacturer All As Specified And Directed Complete. ( I ) Cleaning Of New Rendered Surfaces Properly And Drying The Surfaces. ( Ii ) Applying A Coat Of Oxidised Bitumen Based Solvent Primer @ 0.30 Kg / Sqm ( Iii ) Laying 3 Mm Thick App Modified Water Proofing Membrane With 100 Mm Over Laps Sealed And Bounded To The Surfaces By Torchon Method. ( Iv ) Applying Two Coats Of Bitiminous Aluminium Paint @ 200 Gram / Sq M ( Minimum ) In Two Coats .Make Incorporated : Hyperplas Polyster Of Iwl ( India ) Ltd Or Equivalent In Pidilite Industrries Ltd / Stp Ltd All As Specified And As Manufacturer Instruction , Complete All As Specified And Directed. 115 M&L Salt Glazed Stoneware Drain Pipes 150 Mm Internal Dia Ofgrade ‘A’ Laid In Trenches & Jointed As Specified, Complete All As Specified And Directed. 116 M & L 1:3:6 Typec-2 Using 40 Mm Graded Stone Aggregate Cement Concrete Bedto Drain Pipe Including Packing Under And Haunching Against Side Of Pipe For150 Mm Bore Ofpipe Complete All As Specified And Directed 117 S&F Sand Stone Slab In Sun-Shades, Chajjas, Shelves, Cills, Landings, Cover Stones, Templates, Etc. N.Exc. 2M In Length, Punched Dressed On Faces And Along Exposed Edges, Self Faced On Other Side, Thickness Of Sand Stone Slabs 50 Mm Thick, Complete All As Specified And Directed. 118 S & F Reinforced Concrete Pipes 300 Mm Bore, Class Np2 , Laid And Jointed Complete With Collars, Including Demolition And Breaking Up Drain Pipes, Complete All As Specified And Directed. 119 M&L Point Wiring With 1.5 Sqmm ( Nominal Cross Sectional Area ) Single Core, Pvc Insulated, Unsheathed Frlsh Copper Cable, 1100 Volts Grade, With Multi Stranded Copper Conductor Drawn Through And Including Non-Metallic, Rigid Non Mettalic Pvc Conduit ( Medium Grade ) Concealed In Wall / Ceilingwith And Including 1.5 Sqmm Single Core Pvc Insulated, Multistranded, Unsheathed, Frlsh Copper Conductor Cable As Continuous Earth Continuity Conductor ( Green In Colour ) With Cast Iron / Pressed Steel Modular Terminal Boxes Any Size / Module, Conceiled On Walls And Fixed By Neans Of Brass Screws Incl Modular Cover Plates And Cover Frme Any Size / Module, For Mounting Or Housing Switches, Socket Outlets, Fan Regulators, Etc. Including All Other Fixing Accessoriesone Light / Fan / Bell Controlled By One, One Way Switch 5 / 6 Amps, Complete All As Specified And Directed. 120 Description Same As Per Item No. 119.00 But For One 3 Pin, 5 / 6 Amps Socket Outlet Point On Independent Boardcontrolled By One, One Way 5 / 6 Amps Switch, Complete All As Specified And Directed. 121 Description Same As Per Item No. 119.00 But For One 3 Pin, 5 / 6 Amps Socket Outlet Point On Same Boardcontrolled By One, One Way 5 / 6 Amps Switch, Complete All As Specified And Directed. 122 M&L Point Wiring With 2.5 Sqmm ( Nominal Cross Sectional Area ) Single Core, Pvc Insulated, Unsheathed Frlsh Copper Cable, 1100 Volts Grade, With Multi Stranded Copper Conductor Drawn Through And Including Non-Metallic, Rigid Non Mettalic Pvc Conduit ( Medium Grade ) Concealed In Wall / Ceilingwith And Including 2.5 Sqmm Single Core Pvc Insulated, Multistranded, Unsheathed, Frlsh Copper Conductor Cable As Continuous Earth Continuity Conductor ( Green In Colour ) With Cast Iron / Pressed Steel Modular Terminal Boxes Any Size / Module, Conceiled On Walls And Fixed By Neans Of Brass Screws Incl Modular Cover Plates And Cover Frme Any Size / Module, For Mounting Or Housing Switches, Socket Outlets, Fan Regulators, Etc. Including All Other Fixing Accessories For One 15A Socket Point Independentcompleteall As Specified And Directed. 123 S&Fceiling Rosethree Terminals Surface Bakelite Type, Ac, 50 Hz, 230V Complete All As Specified And Directed. 124 S&F Modular Switch1 Way 6 A , 1 Modulecomplete All As Specified And Directed. 125 S&Fmodular Socket 6 Amps 2 / 3 Pin Combined2 Module Complete All As Specified And Directed. 126 S&F Switch Modular Type 16 A, 1 Module Complete All As Specified And Directed. 127 S&Fsocketmodular Type Multipurposes 6 / 16 A, 2 Module Complete All As Specified And Directed. 128 Supply And Fixing Surface / Wall Mounted Led Batten Poly Carbonate Housingfor Retrofitled Tube T-8 Type Upto 1X20 Watt, 4 Feet Longpre Wired Incl Integrated Electronic Driver Complete With All Connectedaccessories All As Specified And Directed. 129 Supply And Fixing Retrofitled Tube T-8 Type1x20 Watt, 5700 To 6500 K And Thd Less Than 15% , Polycarbonate Body , Glass Tube 4 Feet Longcomplete With 02 Years Warrenty All As Specified And Directed. 130 S&F 10 W Led Batten 2 Feet Long, Wall Mounted, Extruded Aluminium Heat Sink Provided For Efficient Heat Dissipation & Integrated Electronic Driver With System Efficiency 110 Lumen / Watt, Lumen Output >=1100 Lumen Complete All As Specified And Directed. 131 Supply And Fixingexhaust Fans Ac Single Phase 230 Voltpvc Bodyof Size 250Mm Sweep With Louver Completeincluding Provision Of Pvc Flexible Copper Cable Of Size 23 / 0.0076 Two Core From Ceiling Rose To Exhaust Fan Forconnection Andcutting Opening Of Windowsfor Fanbase ( Ply Wood Sheet 12 Mm Thickrequired Size ) , Necessary Fixing Arrangements Complete All As Specifiedand Directed.Note : Cost Of Suitable Opening Window And 12 Mm Thick Ply Woodfor Fixing Exhaust Fan Is Deemed To Be Includedin Overall Rate Quoted. 132 S & Fled Bldg Security Light Fitting30wattmade Up Of Pressure Die Cast Aluminium Housing With Highly Efficient Leds As Lighting Source With Acylic Cover As Diffuser With Ip-66 And Ik-07 Protection Thd < 10% Lumen Output >=110 Lumen Per Watts Complete Incl Gi Pipe 40 Mm Size 1 Meter Bend Into Size For Fixing Of Security Light With Suitable Bracket Complete All As Specified And Directed. 133 S&F Mcb Db Spn 12 Way Double Doorip 43, Ik 09 With 200 Amps Rated Bus Bar , 230 Volts, 50 Hz Complete All As Specifed And Directed. 134 Supply & Fixmcb Spn 32 Amps Current Rating C Series 10 Ka Breaking Capacity Of The Same Make As Item No 13 Complete All As Specified And Directed. 135 Supply & Fixmcb Sp 6 To 32 Amps Current Rating C Series 10 Ka Breaking Capacityof The Same Make As Item No 13 Complete All As Specified And Directed. 136 Supply And Fixing Tv Socket Outlet Complete All As Specified And As Directed. 137 Supply And Fixing Telephonejacket Complete All As Specified And As Directed. 138 M & L Sub Main Wiring With 2 Runs Of 4 Sqmm Main Wire Along With 1 Run Of 4 Sqmm Earth Wire ( Green In Colour ) Single Core Frlsh Pvc Insulated, Unsheathed, Multi-Stranded, 1100 Volts Grade Isi Marked Copper Conductor Cable, Drawn Through And Including Adequate Size Rigid Non-Metallic Pvc Concealed / Surface Conduit ( Medium Grade ) Wherever Necessary With All Fittings & Accessories Including Cutting Chases For Conduits As Required, Sinking For Terminal Boxes, Making Good Disturbed Surfaces Complete All As Specified And Directed.Note:- Two Runs Of Main Copper Conductor, One Run Of Earth Wire And One Run Of Pvc Conduit Shall Be Measured As One Unit Length. 139 S&F Exhaust Fan , Steel Body Ac Single Phase230 Volt Of Size 300 Mm Mmsweep Complete With Blade, Frame And Louvers All As Specified And Directed Incl Making Of Hole In Brick Work Wherever Necessary Making Good Disturbed Surface, Painting To Match With Existing Surfaces, Complete All As Specified And As Directed. 140 Supply , Fixingrigid Non Metallic Pvc Conduit Fixed Conceiled / On Wall Wherever Necessary With All Connectedaccessories20 Mm Dia Forcable Tv Connections, Complete All As Specified And As Directed. 141 Supply And Fixin Replacement Of Ceiling Fan 1200 Mm Sweep , Bldc Fan With Power Factor Of > / =.0.90 For Air Delivery Of 220 M / Cum Minimum Service Value Of 8 With Capacitor Type Modularfan Regulator ( Without Remote ) , Completeall As Specifeid And As Directed. 142 Supplying, Laying, Fixing, Jointing And Testing Lt Under Groundxlpe Insulated, Galvanised Steel Strip Or Wire Armoured Heavy Duty Electric Cable With Aluminium Conductor , Multi Stranded 1100 Volts Grade, Cross-Sectional Area 16 Sq. Mm 2Core, Isi-7098 Marked, With Electric Connection Lugs, Laid In Trenches / Under Floor Under Pcc / Interlocking Tiles Incl Making Good Of Surface With Pcc / Cementing Or Fixed Naked With Walls / On Poles / In Ducts / In Gi Pipes Etc And Including Taking Down Completetrenches / All As As Directed At Site.Note: Excavation, Earth Work, Sand Cushioning, Protection Tiles / Brick / Block Shall Be Measured And Paid Seperately. 143 Tubes, Light Grade, Galvanised, With All Fitting Of Size 40 Mm ;Laid In Trenches For Cable Protection All As Specified And Directed. 144 M&Lof Earthing Complete With Galvanized Steel Earth Plate Electrode 600 X 600 X 6 Mm Thick, Buried Directly In Ground Vertically To A Depth Not Less Than 2.25 Meters Deep Below Ground Levelwith Top Edge Of The Plate Not Less Than 1.5 Mtrs Below Normal Ground Level Connect To Galvanised Earth Lead Wire Of 4.0 Sqmm Size By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron Or Steel Up To 7.5 Meter Length Including Connected To Earth Plate Including Necessary Excavation & Earthwork, Pcc ( 1:3:6 ) Type C-1 Earth Chamber, 40 Mm Thick Rcc Cover 1:2:4 Mix With 6Mm Dia Nominal Reinforcement @ 150 Mm C / C Both Ways Etc Completeall As Shown In Electrical Plate No 5, Connected To Earthing Test Point Complete Including Testing On Completion All As Specified.