Tender For Repair And Maintenance Of Dg Set And Servo Stabilizer Amf Panels Etc At Old Air Field Under Ge 970 Ews, SRINAGAR-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Dg Set And Servo Stabilizer Amf Panels Etc At Old Air Field Under Ge 970 Ews. Submission Date for this Tender is 30-01-2023. Servo Stabilizer Tenders in SRINAGAR Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

35548586
Corrigendum : Tender For Repair And Maintenance Of Dg Set And Servo Stabilizer Amf Panels Etc At Old Air Field Under Ge 970 Ews
Open Tender
Indian
Jammu And Kashmir
SRINAGAR
30-01-2023

Tender Details

Tender For Repair And Maintenance Of Dg Set And Servo Stabilizer Amf Panels Etc At Old Air Field Under Ge 970 Ews

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work: REPAIR AND MAINT OF DG SET AND SERVO STABILIZER AMF PANELS ETC AT OLD AIR FIELD UNDER GE 970 EWS
Sl. No. Item Description
1Disconnecting the engine from base & alternater, and dismantling the top section for top overhauling including replacement of worn out parts,reassembling, connecting with alternator includingtesting for satisfactory running to entire satisfaction of Engr-in-charge, complete all as specified and directed for 100 to 200KVA capacity DG set of any make. Notes :- 1. Spare parts shall be measured and paid for seperately under respective item of schedule of work. 2. Fixing of spare parts shall deemed to be include in the unit rate quoted by the contractor.
2Supply only Kit, fuel filter (Primary, secondary & super bye pass) and ring complete for 100 to 200 Kva DG set.
3Supply only Element for Lubrication oil filter for 100 to 200 Kva DG set.
4Supply only Seal, O Ring for 100 to 200 Kva DG set.
5Supply only Element Air Cleaner for 100 to 200 Kva DG set.
6Supply only Tappet cover Gasket for 100 to 200 Kva DG set.
7All as per item No 1 above butDG set of 62.5 to 82.5 KVA capacity -ditto-
8Supply only Kit, fuel filter (Primary, secondary & super bye pass) and ring complete for 62.5 to 82.5 Kva DG set.
9Supply only Seal, O Ring for 62.5 to 82.5 Kva DG set.
10Supply only Air Cleaner element for 62.5 to 82.5 Kva DG set.
11Supply only Tappet cover Gasket for 62.5 to 82.5 Kva DG set.
12All as per item No. 1 above but for 30/35KVA capacity-ditto-
13Supply only Kit, fuel filter (Primary, secondary & super bye pass) and ring complete for 30/35 Kva DG set.
14Supply only Seal, O Ring for 30/35 Kva DG set.
15Supply only Air Cleaner element for 30/35 Kva DG set.
16Supply only Tappet cover Gasket for 30/35 Kva DG set.
17All as per item No. 1 above but for 20/25 KVA capacity-ditto-
18Supply only Kit, fuel filter (Primary, secondary & super bye pass) and ring complete for 20/25 Kva DG set.
19Supply only Seal, O Ring for 20/25 Kva DG set.
20Supply only Air Cleaner element for 20/25 Kva DG set.
21Supply only Tappet cover Gasket for 20/25 Kva DG set.
22De-scaling of radiator assembly by carefully removing from the engine, transporting to the workshop (if required) and removing the sediments, scales and rust etc by means of acid cleaning, high pressure water washing and air cleaning,arresting the leakages by gas welding / soldering with suitable material at workshop or at site, re-assembling the same with new gaskets including replacement of radiator cap (wherever required) andfixing to the engine for DG Set of capacity from 100 TO 125 KVA complete all as specified and directed by Engineer-in-Charge.
23All as per item No.22 here-in-before but for DG Set of capacity 62.5 to 82.5 KVA -ditto-
24All as per item No. 22 here-in-before but for DG Set of capacity upto 30/35 KVA -ditto-
25Taking down the defective radiator assy from the position transport to work shop removing the damaged cooling fin layer, supply and fix single layer radiator fin assy of complete set made up of copper fins and tube suitable for 82.5 to 125 KVA DG set of any make incl bracing work in any layer for the same all as directed.(Note : Each layer of cooling fin shall be measured and paid separetely)
26Supply & filling Coolant concentrate Superkool xtra as required in the DG oil sump all as directed.
27Supply & filling Engine Oil Premium Blue 15 W 40 grade API CI 4 PLUS / Kirloskar engine oil as required in the DG oil sump all as directed.
28Supply & chelating cleaner Restore Plus solution Part No. AX1001098 Make : Cummins for engines cooling system all as directed.
29Dismantling the defective alternator / field winding of any capacity from the existing foundation and from Engine after removing all electrical connections, transporting to approved / authorised / directed workshop, opening and taking out burnt winding, cleaning the stator assy rewinding with super enameled copper wire as per existing gauge as per original manufacturer and applying insulating varnishing of ‘F’ class, baking in oven re-assembling the alternator, transporting back tosite re-installing the same position, carrying out alignment of complete DG set connecting up all electrical connections testing and commissioning complete. Note: - (a) Rate quoted shall be deemed to be inclusive of making good the disturbed surfaces. (b) The DG set shall be tested on load as per rated capacity for the satisfaction of Engineer- in- Charge to achieve designed parameters.
30S & F in repair door hinges for canopy of any capacityofDGset doorincluding nut, bolt, drilling of hole, welding as per directed.
31Dismantling the old and unserviceable DG Set rubber hose pipe complete set suitable for 20 to 62.5 KVA DG set of any make and typeand replacing the same with ofexisting size and equal length for any capacity DG Set includingboth side hose clamp, with nut, bolt and washers as required , etc as directed by the Engineer in Charge .
32All as per item No 31 here in before but for 82.5 TO 125 KVA DG set -ditto-
33Supply and connect battery lead (not less than 1.00 m long each) made out of PVC Insulated Plain/Striped Automobile Cables with high conductivity bright annealed copper conductor bunched together, insulated with dielectric grade PVC compound (impervious to oils, greases, acids, petrol and water) conforming to IS 2465 of size 25 sqmm soldered one end with copper/brass connector with nuts and bolts for battery pole and the other with copper lug for self starter terminalincluding taking down of existing u/s battery lead with connector and lug of any description complete all as specified and directed by Engineer-in-Charge.
34Supply and fixing in repair rectifiers diodes for 30/125 KVA DG sets.
35S & F in repair battery charging unit panel mounted automatic operated electronically24 Volts DC out put and 230 volts incoming AC , as per the existing make and size to accomodate in the space provided in the AMF panel board .
36Supply and fix in repair maintenance free battery 12V, 180 AH for DG set including initial filling & Charging complete all as specified and directed by Engineer-in-Charge.
37All as per item No. 36 here-in-before but of rating 12V, 150 AH -ditto-
38All as per item No. 36 here-in-before but of rating 12V, 80/90/100 AH -ditto-
39Dismantling the unserviceable Dynamo / Alternators 12/24 volts and rewindingwith ‘F’ class copper wire of 22 /existing gauge incl dismantling the old coil, cleaning thoroughly and winding with super enamelled copper cord of existing size and gauge, varnishing, drying etc and re fixing with dynamo/alternator properly including testing on completion complete all as specified and directed by Engineer-in-Charge.
40Dismantling the defective Dynamo /Alternators 12/24 volts and necessary repair with replacement of defective spares such as, carbon brushes, carbon spring, bearing, bushes, defective wiring, and soldering after re-fixing at site complete all as specified and directed by Engineer-in-Charge.
41Dismantling the defective self starter assembly 12V/24V carefully from the DG set and carryout repair and servicing by cleaning all accessories with suitable cleaning agent and supply and replace commentator, carbon brush set, carbon brush holder, king pin holder, armature choke nut, body screens, clutch plate assay and solenoid etc re-assembling and re-fixing the same and testing on completion for DG set of capacity from 100 to 200 KVA complete all as specified and directed by Engineer-in-Charge.
42All as per item No. 41 here-in-before but for DG set of capacity from 62.5 to 82.5 KVA -ditto-
43All as per item No. 41 here-in-before but for DG set of capacity from 20/35 KVA -ditto-
44M&L for providing new AVR unit suitable for 82.5 TO 125 KVA DG Set size in repairs ie taking down of old AVR unit, complete all as specified and as directed by Engineer -in-charge. Make: Kirloskar/cummins/stanford
45All as per Item No 44 above, but for 20 to 63 KVA DG set -ditto-
46Dismantling the old and unserviceable DG Set Diesel/oil pressure pipe of existing sizeand replacing the same with ofexisting size and equal length of20 KVA to 62.5 KVADG Set includingboth side hose clamp, etc as directed by the Engineer in Charge .
47Dismantling the defective exciter of DG set of any capacity from the existing foundation and engine after removing all electrical connections, transporting to workshop rewinding the burn out coil complete with super enamelled copper wire rewinding, applyinginsulating varnish of "F" class baking in oven reassembling the alternator, transporting back to site, re-installing the same carrying out alignment of complete DG Set connecting up all electrical connections, testing & commissioning complete.
48Supply and fixinginrepair digital type Amp/volt meter square typeup to 3 Phase AC 50 HZ, 500 volts of and connecting complete .
49supply and fixing in repair lamp indicator assy LED lamp type 230 volts AC .
50Supply and wrap asbestos rope of 10 mm dia of superior quality over silencer of DG sets including taking down of existing unserviceable rope complete all as specified and directed by Engineer-in-Charge. Note: Straight length of silencer is measured for the purpose of payment
51S&F in replacement fan belt suitable for 82.5 TO 125 KVA DG Set as per existing model and size including dismantling the old one.
52All as per item No 51 above but for 20 KVA to 63 KVA DG Set as per existing model and size including dismantling the old one.
53S & F in repairs self starter 12V/24V with solenoid switch assy complete set as per existingmake of DG Set 20 to 63 KVA all as directed.
54S & F in repairs self starter with solenoid switch assy complete set as per existing make of DG Set for 82.5/125 KVA all as directed.
55S & F in repairs Dynamo / Alternator assy 12 / 24 Volts of existing type and capacity suitable for DG set of 20 to 125 KVA capacity incl necessary elect connections all as directed.
56S & F in repairs solenoid switch complete set as per existing size and make of DG Set 20 to 125 KVA DG Set all as directed.
57S & F in repairs magnetic speed censor assy suitable as per existing make of DG sets .
58S & F in repairs Electronic Speed control unit suitable for 20 to 125 KVA Capacity of any make DG sets incl neccessary connections and testing complete all as directed.
59Dismantling and taking out the defected speed Governor unit with fuel injector pump assy from the DG set of capacity 100 to 125 KVA, transport to authorised work shop, cleaning the Fuel injector, Nozzle, calibration in test bench re-assembling into the DG set with necessary new gaskets/ nut, bolt and washer and testing complete all as directed. Note : The cost of spares like new injector / nozzle / gasket / seal / nut, bolt and washers are deemed to be included in the quoted rates.
60All as per item No. 59 here-in-before but for DG set of capacity 62.5 /82.5 KVA -ditto-
61All as per item No. 59 here-in-before but for DG set of capacity 20/ 35 KVA -ditto-
62Taking down unserviceable engine wiring and M&L for rewiring of engine safety control system from control panel to engine control gadgets like HWT, LLOP, shut down valve, dynamo & self-starter etc for DG set of capacity from 100 to 125 KVA complete all as specified and directed by Engineer-in-Charge.
63All as per item No. 62 here-in-before but for DG set of capacity from 62.5 to 82.5 KVA -ditto-
64All as per item No. 62 here-in-before but for DG set of capacity upto 35 KVA -ditto-
65S & F in repairs self starter push button / or with Key arrangement for DG starting suitable for Kirloskar / Cummins DG sets all as directed.
66S & F in repairs micro processor based DG control unit suitable for 20 to 125 KVA Capacity as per existing make of DG sets incl neccessary connections and testing complete all as directed.
67S & F of distilled water in the DG battery all as directed.
68S & F in repairs Feed pump unit, hand operatedfor 20 to 125 KVA capacity DG sets
69M & L for openingthe cylinder head of the engine and oil sump carefully for replacement of head gasketincluding sump gasketcomplete refixing the headand sump to arrest oil leakage with engine complete with proper alignment and testing the enginefor 1 hrson load to achiveve designed parameters all as directed by Engineer-in-Charge of capacity 20 KVA to 125 KVA.
70Supply and fixing in repair including testing and commissioning outdoor type factory made powder coated AMF Panel Board cubical type,over all size not less than 1000x750x400 mm suitable for DG set 125 KVA capacity, with suitable size 4 Noscopper bus bar 400 amps,having locking arrangments floor mounted free standing weatherproof panel with IP-54 protection fabricated out of suitable sized angle iron and flats and covered with 3 mm thick CRCA sheet duly pretreated in seven tank process for de-greasing , de-rusting & phosphated painted with 2 coats of primer paint then the panel surface shall be finished andthen painted with final coat of epoxy based powder coated paint.Panel shall be compartmentrisedwith rubber gasketed hinged door. Panel shall be having only one side opening for installation of separate cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming & outgoing cables. Panel have CT 5/400 Amps - 03 Nos, Digital Ammeter 0-300 Amps, Digital Voltmeter 0-500 Volts, Phase Indicator LED (RYB) - 03 Nos. A clear space of 200mm to be kept from floor level for switchgear compartment. Extended busbar links/ terminals to be provided for connecting cables. Air ventillation louvers to be provided for heat dissipation with earthing terminal at each end of the panel. Suitable sized knock-out holes consisting of the following:-
71a) Power contactor-4 pole, of suitable current rating with thermal overload relay - 02 Nos (for alternator and mains) b) HRC fuse of suitable current rating for short circuit protection c) Microprocessor based AMF module incorporating functions:- -Supply failure timer -Restoration timer -3 Impulse automatic engine start/ stop logic -Mains/ Generator Voltage & Frequency sensing d) Aluminium bus bars of suitable capacity with incoming/ outgoing terminals e) Instrument fuses duly wired and ferruled f) MCCB of suitable rating 4 pole with overload and short circuit protections - 02 No"s (for alternator & mains) g) Current Transformers of suitable rating
72Supply,fixing in repair including testing and commissioning outdoor type factory made powder coated AMF Panel Board cubical type,over all size not less than 1000x750x400 mm suitable for DG set 35 KVA capacity, with suitable size 4 Noscopper bus bar 400 amps,having locking arrangments floor mounted free standing weatherproof panel with IP-54 protection fabricated out of suitable sized angle iron and flats and covered with 3 mm thick CRCA sheet duly pretreated in seven tank process for de-greasing , de-rusting & phosphated painted with 2 coats of primer paint then the panel surface shall be finished andthen painted with final coat of epoxy based powder coated paint.Panel shall be compartmentrisedwith rubber gasketed hinged door. Panel shall be having only one side opening for installation of separate cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming & outgoing cables. Panel have CT 5/400 Amps - 03 Nos, Digital Ammeter 0-200 Amps, Digital Voltmeter 0-500 Vols, Phase Indicator LED (RYB) - 03 Nos. A clear space of 200mm to be kept from floor level for switchgear compartment. Extended busbar links/ terminals to be provided for connecting cables. Air ventillation louvers to be provided for heat dissipation with earthing terminal at each end of the panel. Suitable sized knock-out holes consisting of the following:-
73a) Power contactor-4 pole, of suitable current rating with thermal overload relay - 02 Nos (for alternator and mains) b) HRC fuse of suitable current rating for short circuit protection c) Microprocessor based AMF module incorporating functions:- - Supply failure timer -Restoration timer -3 Impulse automatic engine start/stop logic -Mains/ Generator Voltage & Frequency sensing d) Aluminium bus bars of suitable capacity with incoming/ outgoing terminals e) Instrument fuses duly wired and ferruled f) MCCB of suitable rating 4 pole with overload and short circuit protections - 02 No"s (for alternator & mains) g) Current Transformers of suitable rating
74Supply,fixing in repair including testing and commissioning outdoor type factory made powder coated AMF Panel Board cubical type,over all size not less than 1000x750x400 mm suitable for DG set 82.5 KVA capacity, with suitable size 4 Noscopper bus bar 400 amps,having locking arrangments floor mounted free standing weatherproof panel with IP-54 protection fabricated out of suitable sized angle iron and flats and covered with 3 mm thick CRCA sheet duly pretreated in seven tank process for de-greasing , de-rusting & phosphated painted with 2 coats of primer paint then the panel surface shall be finished andthen painted with final coat of epoxy based powder coated paint.Panel shall be compartmentrisedwith rubber gasketed hinged door. Panel shall be having only one side opening for installation of separate cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming & outgoing cables. Panel have CT 5/400 Amps - 03 Nos, Digital Ammeter 0-200 Amps, Digital Voltmeter 0-500 Vols, Phase Indicator LED (RYB) - 03 Nos. A clear space of 200mm to be kept from floor level for switchgear compartment. Extended busbar links/ terminals to be provided for connecting cables. Air ventillation louvers to be provided for heat dissipation with earthing terminal at each end of the panel. Suitable sized knock-out holes consisting of the following:-
75a) Power contactor-4 pole, of suitable current rating with thermal overload relay - 02 Nos (for alternator and mains) b) HRC fuse of suitable current rating for short circuit protection c) Microprocessor based AMF module incorporating functions:- - Supply failure timer -Restoration timer -3 Impulse automatic engine start/stop logic -Mains/ Generator Voltage & Frequency sensing d) Aluminium bus bars of suitable capacity with incoming/ outgoing terminals e) Instrument fuses duly wired and ferruled f) MCCB of suitable rating 4 pole with overload and short circuit protections - 02 No"s (for alternator & mains) g) Current Transformers of suitable rating
76Supply and fixing in repair copper cable 2.5 sqmm 8 core suitable for connection of AMF Panel with protection pipe complete all as specified and directed.
77M&L for isolating, disconnecting and transporting theServo voltage stabilizer ofcapacity 25 KVA to 100 KVA workshop for repair, strip opening of stabilizer for inspection and acertaining the defects for repair & cleaning, servicing all serviceable acessories including reassembling after repair, preparation for and painting with two coats of synthetic enamel paint of approved colour and marking SM/MES No., transporting back to site, reinstallation and testing on load complete all as specified and directed by Engr-in-Charge.(Note:- Parts required for replacement will measured and paid seperately under respective items.)
78Supply and fix in repair of LT current transformer ratio as per existing rating in LT panels complete all as specified and directed by Engr-in-Charge.
79Supply and fix in repair of Auto/Manual selector switch of voltmeter/ammeter in LT panel boards complete all as specified and directed by Engr-in-Charge.
80Supply and fix in repair PCB Card/Plate for automatic voltage correction suitable for servo stabilizer of capacity upto 25KVA to 75 KVA as per site requirement for type and make complete all as specified and directed by Engr-in-Charge.
81All as per srl item No. 80 here-in-before, but of capacity 100 to 250 KVA complete all as specified and directed by Engr-in-Charge.
82Taking down old burnt out winding and replacement of same for stabilizeroil immersed type of capacity 25 KVA to 250 KVA by using suitable gauge super enamelled copper conductor as per existing winding complete all as specified and directed by Engr-in-Charge.
83Supply of insulation transformer oil toping up into voltage stabilizer of different capacity complete with superior quality insulating oil BDV not less than 50 KV all as specified and directed by Engr-in-Charge.
84Dehydration of transformer oil for LT/HT AVR/Servo voltage stabilizer upto BDV not less than 50 KV all as specified and directed by Engr-in-Charge.
85Supply and fix in repair cast iron dimmer gear set for automatic voltage correction capacity 25 KVA to 250 KVA with as per site requirement for type and make complete all as specified and directed by Engr-in-Charge.
86Supply and fix in repair micro limit switch with cam lever complete for servo stabilizer of capacity 25 KVA to 250 KVA as per site requirement for type and make complete all as specified and directed by Engr-in-Charge.
87Supply and fix in repair of servo motor synchronous type of torque capacity 10 Kg for automatic voltage correction suitable for servo stabilizer of capacity 25 KVA to 250 KVA as per site requirement for type and make complete all as specified and directed by Engr-in-Charge.
88Supply and fix in repair servo dimmer booster coil for automatic voltage correction suitable for servo stabilizer of capacity 25 KVA to 250 KVA as per site requirement for type and make complete all as specified and directed by Engr-in-Charge.
89Supply and fix in repair Carbon brush with holder assembly for servo stabilizer of capacity 25 KVA to 250 KVA as per site requirement for type and make complete all as specified and directed by Engr-in-Charge.
90Supply and fix in repair bush rod brass for servo stabilizer of capacity 25 KVA to 250 KVA as per site requirement for type and make complete all as specified and directed.
91Taking down old unserviceable control wiring and replacement of control wiring using suitable gauge super enamelled copper conductor as per existing winding for stabilizer transformer oil immersed type of capacity 25 KVA to 250 kVA complete all as specified and directed.
92Supply and fix in repair of over load relay for 25 to 250 KVAvoltage stabilizer complete all as specified and directed by Engr-in-Charge.
93Supply and fix in repair of graphite carbon bursh suitable for Servo voltage stabilizer of any capacity, complete all as specified and directed complete all as specified and directed.
94Supply and fix in repair of Capacitor of capacity 1.42 to 4.0 MF + 5%, 440V, AC 50Hz, complete all as specified and directed by Engr-in-Charge.
95Supply and fix in repair of Pinion with gear (Medium) suitable for servo stablizer of any capacity, complete all as specified and directed by Engr-in-Charge.
96Supply and fix in repair of Pulsing Transformer heavy duty suitable for servo stablizer of any capacity, complete all as specified and directed by Engr-in-Charge.
97Supply and fix in repair of Control Transformer heavy duty sutiable for servo stablizer of any capacity, complete all as specified and directed by Engr-in-Charge.
98Supply and fix in repair Off Load change over switch 100 Amps, 4 Pole madeout of Sheet steel enclosure side operated including replacement of incoming and outgoinglugs and fixing arrangement on panel/wall complete all as specified and directed by Engr-in-Charge.
99Supply and fix in repair Off Load change over switch 200 Amps, 4 Pole madeout of Sheet steel enclosure side operated including replacement of incoming and outgoinglugs and fixing arrangement on panel/wall complete all as specified and directed by Engr-in-Charge.
100Supply and fix LED ?ood light fitting of 150 Watts with driver inside a pressure die cast aluminium housing with toughened front glass cover, IP65 degree of protection includig taking down of existig unserviceable flood light fitting of any description complete all as specified and directed by Engineer-in-Charge. Make: Bajaj Cat No. BJFL 150W LED I orlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves
101All as per Ser Item No. 100 here-in-before but of 200 Watts Make: Bajaj Cat No. BJFL 200W LED Iorlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves
102All as per Ser Item No. 100 here-in-before but of 240 Watts Make: Bajaj Cat No. BJFL 240W LED WH MBor latest upgraded equivalent model in Havells/ Wipro/Crompton Greaves
103Supply and fix LED street light fitting 45 watts with high efficiency long life LEDs In-built replaceable electronic driver complete housed in pressure die-cast aluminium alloy covered with polycarbonate cover with IP65 degree of protection and fixing on existing bracket duly removing existing unserviceable street light fitting complete all as specified and directed by Engineer-in-Charge. Make:Bajaj Cat No. ENXT P 54L WH CR PC SDorlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves
104All as per item No. 103 here-in-before but of 60 watt Make:Bajaj Cat No. ENXT P 72L WH CR PC SDorlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves
105All as per item No. 103 here-in-before but of 70 watt Make:Bajaj Cat No. ENXT P 84L WH CR PC SDorlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves
106All as per item No. 103 here-in-before but of 90 watt Make:Bajaj Cat No. BRTFG 90W LED CRorlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves
107All as per item No. 103 here-in-before but of 120 watt Make:Bajaj Cat No. BRTFG 120W LED CRorlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves
108Material and labour for earthing complete with galvanised steel earth plate electrode 60cmx 60cmx 6.00 mm thick buried directly in ground(Earth pit not less than 2.25 metre below normal ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected and including GI strip 32mm x 6mm by means of GI bolts, nuts, check nuts and washers, earth plate surrounded by packed alternatelayers of coal dust and common salt 15cm thick, all around top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh and 50mm bore GI pipe light grade for protection of GI strip 32mmx6mm from top of earth plate upto test point (upto 7.5metre in length) connected with suitable size of GI nuts, bolts and washersall as shown in Electrical plate No. 3 of SSR Part-I, testing on completion including excavation/earth work in any type of soil/rock, PCC chamber (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC (1:2:4) type B-1 cover slab reinforced with 8mm dia TMT steel bars @ 100mm c/c both ways with suitable handle for lifting arrangement & including formwork and MS frame using MS angle iron 40x40x6mm complete all as specified and directed.Note :- Earth pit shall be constructed 50cm from the side of excavation to avoid sinking of pit.
109Excavationintrenchesnotexc 1.5 M wideandnotexc1.5 Mindepthandgettingoutin soft/loosesoilorhard/densesoilfortakingup orlaying ofcableallasspecifiedanddirected.
110Returning, filling inincludingspreading, levelling, wateringandwellramminginlayersnotexceeding25 cms complete allasspecifiedanddirected.
111Removal of surplus soil not exceed to a distance of 50M where directed at a level not exc . 1.5M above the starting point complete allasspecifiedanddirected.
112Supplyandlayingdryriversandlaidintrenchesascablecushioningandcovering complete allasspecifiedanddirected. Note : Punned thickness only measured and paid
113M & Lfor brickwell burntlocallyavailablesubclass "B" laid over sand cushioningtocableintrencheskeepingwidthofbrickparalleltothelengthofcable complete allasspecifiedanddirected.
114Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminiumconductor of size 16 sq mm 4 Corealong with suitable size aluminium cable lugs and jointed in any description complete all as specified. Note - Excavation, earthwork, sand cushioning and brick protection shall be measured and separately.
115Ditto all as per item No 114but of size 3.5 Core x 35 Sqmm
116Ditto all as per item No 114but of size 3.5 Core x 50 Sqmm
117Ditto all as per item No 114but of size 3.5 Core x 70 Sqmm
118Ditto all as per item No 114but of size 3.5 Core x 95 Sqmm