Tender For Provision Of Storage Accommodation Age (I) (P) Oaf Srinagar., srinagar-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Provision Of Storage Accommodation Age (I) (P) Oaf Srinagar.. Submission Date for this Tender is 21-01-2023. Angle Tenders in srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

35537303
Corrigendum : Tender For Provision Of Storage Accommodation Age (I) (P) Oaf Srinagar.
Open Tender
Indian
Jammu And Kashmir
srinagar
21-01-2023

Tender Details

Tender For Provision Of Storage Accommodation Age ( I ) ( P ) Oaf Srinagar -Excavation In Trenches, Not Exc. 1.5 Mtr Wide And Not Exc 1.5 Mtr Deep And Getting Out In Any Type Of Soil For Foundation, Laying Of Cables / Pipe Etc, Complete All As Specified And Directed. 2 M&L For Pcc 1:4:8 Type D-2 ( Using 40Mm Graded Crushed Stone Aggregate ) As In Foundation Filling And Mass Concrete, Complete All As Specified And Directed. 3 M&L For Rcc M-25 Grade ( Design Mix ) As In Foundations Including Rafts, Footings, Foundation Beams, Plinth Beams, Bases For Columns Etc. Basement Slabs, Under Reamed Piles, Complete All As Specified And Directed. 4 M&L For Rcc M-25 Grade ( Design Mix ) As In Columns, Pillars, Peirs, Posts And Struts, Complete All As Specified And Directed. 5 M&L For Rcc M-25 Grade ( Design Mix ) As In Beams, Lintels, Over 1.5 Mtr Clear Span Etc, Complete All As Specified And Directed. 6 Use And Waste Formwork To Sides Of Rough Finished Surfaces Of Concrete Foundation, Footing, Bases Of Columns, Plinth Beam, Side And Soffits Of Plinth Beam And Similar Work, Complete All As Specified And Directed. 7 Use And Waste Formwork To Rough Finished Surfaces Of Concrete Sides Of Columns, Pillars As In Square, Rectangular Or Polygonal Etc, Complete All As Specified And Directed. 8 Use And Waste Formwork To Rough Finished Concrete Surfaces, Sides And Soffits Of Floor Or Roof Beams, Lintel Beams, Cantilevers, Shelves Etc, Complete All As Specified And Directed. 9 M&L For Brick Work With Sub Class B Bricks ( Old Size ) , Straight Or Curved On Plan Exc 6 Mtr Mean Radius, Built In Cm 1:6, Complete All As Specified And Directed. 10 M&L For 10Mm Thick Rendering On Brick Work Or Concrete Surfaces Of Internal Wall In Cm 1:6, Finished The Surface Even And Smooth Without Using Extra Cement, Complete All As Specified And Directed. 11 M&L For 15Mm Thick Rendering In Cm 1:4 On Fair Faces Of Brick Work, Concrete Block Masonry Or Concrete Surface, Finished The Surface Even And Smooth Without Using Extra Cement, Complete All As Specified And Directed. 12 M&L For Preparation Of Newly Plastered Surface Of Walls And Applying Three Coats White Wash, Complete All As Specified And Directed. 13 M&L For Preparation Of Newly Plastered Surface Of Walls And Applying Two Coats Of Cement Base Paint Over A Coat Of Wall Primer, Complete All As Specified And Directed. 14 M&L For Moorum / Red Bajari, Filling In Floors Or Pavings, Laid In Layers Not Exc. 15Cm Thick, Spread, Levelled And Rammed Including Watering, Complete All As Specified And Directed. 15 M&L For Hardcore Of Broken Stone Or Boulders Of Gauge Not Exc. 63Mm, Deposited, Spread And Levelled In Layers Not Exc. 15Cm Thick, Watered And Rammed To A True Surface, Complete All As Specified And Directed. 16 M&L For 75Mm Thick Pcc 1:4:8 Type D-2 ( Using 40Mm Graded Crushed Stone Aggregates ) As In Sub Base Of Floor, Complete All As Specified And Directed. 17 M&L For Machine Cut, Mirror Polished Kota Stone Slab Flooring 18-20Mm Thick, Laid Over And Including 20Mm Thick Screed Bed In Cm 1:6 And Jointed And Pointed With Grey Cement Slury Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing, Complete All As Specified And Directed. 18 All As Per Item No 17.00 Here-In-Above But As In Skirting Of Floor And Fixed Over 15Mm Thick Plaster In Cm 1:3, Complete All As Specified And Directed. 19 S&F Steel Windows With Side Hung Shutters Including Box Type Hinges With Steel Handle And Steel Peg Stay, Complete With Glazing Bars, Dovetailed Or Welded, Complete All As Specified And Directed. 20 S&F 3Mm Thick Plain Sheet Glass, Ordinary Quality And Glazing With Oil Putty Or Wooden Beads In Sqare Area Not Exc 0.50 Sqm In Each Pane, Complete All As Specified And Directed.Note :- Fixing Only Rate Is Included In Window / Door Shutter Items Considered Therein. 21 S&F Pressed Steel Frames For Doors With One Or More Rebates Includings Necessary Fixing Lugs, Hold Fasts, Hinges, Lock Stricke Plate Etc Size Or Section Of Frame 105Mm X 60Mm And Including Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Zinc Chrome Primer, Complete All As Specified And Directed. 22 M&L For Pcc 1:3:6 Type C-0 ( Using 12.5Mm Graded Crushed Stone Aggregates ) As In Back Filling Of Chowkhats, Complete All As Specified And Directed. 23 S&F 35Mm Thick 2Nd Class Hard Wood Flush Door Shutters, Solid Core Construction With Block Board Core And Plywood Face Panels, Commercial Type On Both Sides, Fixed To Chowkhat At Site, Complete All As Specified And Directed. 24 S&F 300Mm Size Aluminium Alloy Anodised Sliding Door Bolt, Isi Marked With Hasp And Staple ( Bolt Type ) And Fixing Clips Of Sheet Cast Or Extruded Sections With Fixing Bolts And Sliding Bolt Of Extruded Section, Complete All As Specified And Directed. 25 S&F Mild Steel 200Mm Long Barrel Tower Bolts, Isi Marked, Stove Enamelled Black, Complete All As Specified And Directed. 26 S&F Mild Steel 150Mm Long Barrel Tower Bolts, Isi Marked, Stove Enamelled Black, Complete All As Specified And Directed. 27 S&F Floor Door Stopper Of Aluminium Alloy Body And Tongue, Anodised, With Hard Drawn Steel Spring, Fixed In Floor, Over All Length Of Cover Plate 140Mm, Complete All As Specified And Directed. 28 M&L For Preparation Of New Wood Or Wooden Based Surfaces Of Any Description, Not Otherwise Described Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer, Complete All As Specified And Directed. 29 M&L For Preparation Of New Steel Surfaces Of Any Description, Over 10 Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer, Complete All As Specified And Directed. 30 M&L For Cement Concrete 1:2:4 Type B-1 ( Using 20Mm Graded Crushed Stone Aggragate ) As In Lintel Upto 1.5 Mtr Clear Span, Cills, Steps, Seismic And Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets And Railings Upto 60Cm In Height, Coping, Kneelers, Apex Stones, Bed Plates, Kerbs And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating, Complete All As Specified And Directed. 31 S&F Mild Steel Rolled Section As In Main And Cross Beams, Hip And Jack Rafters, Purlins Where Connected To Common Rafters And Running Rails And Guides For Sliding Doors, Fixed With Angle Cleats Or Other Connecting Plates Etc, Confirming To Fe 410-W- ( Gde-E-250 ) Quality - A, Complete All As Specified And Directed.Notes :- Fabrication Of Roof Truss, Purlins Post, Rafter Etc Cutting, Welding, Bending, Or Any Other Nature Of Work Shall Be At Site Or Shop And Rate For The Same Shall Be Included In Quoted Rate. 32 S&F Mild Steel Plates ( Plain Or Chequered ) Channels, Square Or Beams Cut Or Notched ( Ordinary And Counter Sunk ) Forming Holes, Without Any Attachments Or With Riveted, Bolted Or Welded Attachments Etc. Confirming To Fe 410-W- ( Gde-E-250 ) Quality - A, Complete All As Specified And Directed.Notes :- Cutting To Required Size And Welding Or Bolting To Beam, Post, Rafter Shall Be At Site, Rate For The Same Shall Be Included In Quoted Rate. 33 S&F Mild Steel Bolts 20-25Mm Dia, Purpose Made With Hexagonal Or Square Head One End And Screwed The Other Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Exc 30Cm Long, Complete All As Specified And Directed. 34 S&F 0.50Mm Thick Prepainted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet Of An Colour Having Tensile Strength Of 550 Mpa Minimum Yeiled Strength As In Roof Covering / Cladding To Wall, It Shall Be Caoted Withhot Dip Alloy Of 55% Aluminium, 43.5% Zinc, 1.5% Silicon And Finished With Resin Coat On Both Surface @ 150 Gm / Sqm Of Coating As Specified And Shall Be Fixed With Hot Dip Galvanised, Seld Drilling And Self Tapping Screws Neoprened And Epdm Washers As In Roof Covering, Complete All As Specified And Directed. 35 S&F 0.50Mm Thick Prepainted Galvalume Aluminium Zinc Coating Gi Based Plain Steel Sheet Of An Colour Having Tensile Strength Of 550 Mpa Minimum Yeiled Strength As In Roof Covering / Cladding To Wall, It Shall Be Caoted Withhot Dip Alloy Of 55% Aluminium, 43.5% Zinc, 1.5% Silicon And Finished With Resin Coat On Both Surface @ 150 Gm / Sqm Of Coating As Specified And Shall Be Fixed With Hot Dip Galvanised, Seld Drilling And Self Tapping Screws Neoprened And Epdm Washers As In Roof Covering, Complete All As Specified And Directed. 36 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc. 25Cm Thick, Complete All As Specified And Directed. 37 Removing Excavated Material / Soils To A Distance Not Exc. 50 Mtr And Depositing Where Directed At A Level Not Exc 1.5 Mtr Above The Starting Point, Complete All As Specified And Directed. 38 S&F Mild Steel Tmt Bars 10Mm Dia And Over, Cut To Length, Bent To Shape As Required Including Cracking, Bending, Hooking Ends And Binding With Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia, Complete All As Specified And Directed. 39 All As Per Ser Item No 38.00 Here-In-Above But 5Mm Dia And Over Upto And Including 10Mm Dia In Stirrups, Spaces And Binders. 40 S&F Anodised Aluminium Snap Grid Frame Work For False Ceiling Including Hangers 6Mm Dia Gi ( Upto 1200Mm Length ) Adjusting Level Fixed To Roof Slabs By Means Of Ceiling Cleats Made Out Of Gi Flat 40 X 3Mm Size, 60Mm Long And Expansion Hold Fasteners 12.5Mm Dia, 40Mm Long, Complete All As Specified And Directed. 41 S&F 6Mm Thick Asbestos Cement Building Boards, Plain, Complete All As Specified And As Per ManufacturerS Instructions. 42 M&L For Mild Steel Framed Work Such As Grills, Gratings Etc With Ends Of Bars Shouldered And / Or Riveted Or Forged Into Spikes, Framed Guard Bars, Barred Iron Doors, Raillings, Staging For Water Tanks And Similar Work, Confirming To Fe-290 Gde E-165, Complete All As Specified And Directed. 43 Surface Excavation Not Exc 30Cm Deep And Averaging 15Cm Deep And Getting Out In Any Type Of Soil, Complete All As Specified And Directed. 44 M&L For Machine Pressed Precast Concrete Interlocking Paver Block Of Any Shape And Size, Confirming To Is : 15658-2006 Of 60 Mm Thickness, M-35 Grade With Grey Cement And Pigment, Laid Over And Including 25Mm Thick Sand Cushioning, Complete All As Specified And Directed. 45 M&L For 75Mm Thick Cement Concrete 1:3:6 Type C-1 ( Using 20Mm Graded Crushed Crushed Stone Aggragates ) As In Plinth Protection And Paving, Laid In Slope, Finished The Surface Even And Fair Including Making Joints At Every 2.5 Mtr And At Corner And Filled With Bitumen 85 / 25 And Sand In Ratio 1:2, Complete All As Specified And Directed. 46 M&L For Point Wiring ( Concealed Type ) With 1.5 Sqmm Copper Conductor ( Multistranded ) Pvc Insulated And Unsheatheted Frls Electric Cable 1100 Volts Grade Wiring In Pvc Conduit Of Suitable Size With All Fittings & Accessories And Including Pvc Insulated Electric Cable 1100 Volts 1.5 Sqmm ( Multistranded ) Copper Conductor Single Core ( Green Colour ) Cable As Continuous Earth Wire Conncted To Common Earth Dolly Including Sunk Sheet Terminal Box Made Out Of 1.6Mm Thick Ms Sheet, Covered With 3Mm Thick Plastic Laminated Sheet For One Light Point / Fan Point Controlled By One Switch 5 Amp, Complete All As Specified And Directed. 47 All As Per Ser Item No 46.00 Here-In-Above But For One 3 Pin 5 Amp Socket Outlet On The Independent. 48 All As Per Ser Item No 46.00 Here-In-Above But For One 3 Pin 5 Amp Socket Outlet On The Same Board With Other Switches. 49 All As Per Ser Item No 46.00 Here-In-Above But For One Socket Outlet 15 Amps On The Independent Board With 2.5 Sqmm Copper Conductor Multistanded Frls Pvc Insulated And Sheathed Electric Cable 1100 Volts Grade Including Pvc Insulated And Unsheathed Frls Electric Cable 1100 Volts 2.5 Sqmm Copper Stranded Conductor As Continuous Earth Wire Connected To Common Earth Dolly. 50 S&F Switch Piano, Flush Type, 5 Amp, One Way, 15 Amp, Complete All As Specified And Directed. 51 S&F Socket Outlet 2 In 1, 3 Pin, 5 Amps, Flush Type, Complete All As Specified And Directed. 52 S&F Switch Socket Combination Outlet 5 And 15 Amp, 2 In 1, 5 Pin, Flush Type, Complete All As Specified And Directed. 53 S&F Switch Socket Combination Outlet 5 Amp, 2 In 1 Pin, Flush Type, Complete All As Specified And Directed. 54 S&F Ceiling Rose 3 Terminal, Size 65Mm X 50Mm, Surface Bakelite, Complete All As Specified And Directed. 55 S&F Stepped Type Electronic Fan Regulator Flush Type On The Existing Phenolic Laminated Sheet Etc, Complete All As Specified And Directed. 56 S&F Led Light Fitting 1 X 20 Watt, 4 Feet Long 220 Volts, Ac, Decorative Box Type With Driven, Holder Including Led Tube Light, Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose, Complete All As Specified And Directed. 57 S&F Led Street Light Fitting 35 Watt, 230 Volt, Ac, Outdoor Type With High Pressure Die Cast Aluminium Housing And Heat Resistant Complete With Driven, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In Multiple Optics Compete With Ip 65 / 66 Protection, Complete All As Specified And Directed. 58 S&F Ceiling Fan Complete With Blades, Down Rods, Electronic Regulator And Accessories, 230 Volt, 1200Mm Sweep, Min Air Delivery 210 Cfm With Service Value 6.00 Bee, Five Star Rated With Brushless Direct Current Motor ( Bldc ) And All Accessories Including Connecting Up With 3 Core Flexible Coper Conductor Cable Of Suitable Size From Ceiling Rose, Complete All As Specified And Directed. 59 S&F Sheet Metal Enclosure, Factory Made Double Door Shutter For Db Spn, 240 Volts, 8 Ways With 200 Amps Rated Bus Bar, Neutral Link, Earth Bar, Complete All As Specified And Directed. 60 S&F Mcb Spn 32 Amps, 230 Volts C Curve, 50 Hz, Ac, 10 Ka, Complete All As Specified And Directed. 61 S&F Mcb Spn 5 To 32 Amps, 230 Volts C Curve, 50 Hz, Ac, 10 Ka, Complete All As Specified And Directed. 62 M&L For Earthing Complete With Galvanised Mild Steel Earth Plate Electrode Of Size 60Cm X 60Cm X 6Mm Thick, Buried Directly In Ground ( Earth Pit Not Less Than 2.25Mtr Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Mtr Below Normal Ground Level, Connected With Gi Wire 4Mm Dia By Means Of Lugs, Bolts, Nuts, Check Nuts, Washers Of Galvanised Iron Or Steel, Gi Protection Pipe Of 15Mm Bore, Light Grade Including Earth Work, Earth Plate Surround By 15Cm Thick Packed Layer Of Charcoal And Common Salt Alternatively Upto 90Cm, 20Mm Bore Gi Watering Pipe Medium Grade, Gi Sheet Funnel Wire Mesh, Concrete Pit, Rcc Cover In Pcc 1:2:4 Type B-1 Duly Reinforced With Tmt Bars 8Mm Dia At The Rate Of 150Mm Center To Centre Spacing In Both Way With Suitable Lifting Handle And Pit / Chamber In Pcc 1:3:6 Type C-1, For Pit Cover And Connecting To Main Switch Board / Main Db’S Including Testing On Completion, Complete All As Shown In Electric Plate No. 3 Of Ssr Part-I And Directed. 63 Supply & Laying Xlpe Insulated, Armoured Heavy Duty Electric Power Cable With Aluminium Conductor, 1100 Volts Grade, Cross Sectional Area 10 Sqmm 2 Core, Complete All As Specified And Directed. 64 M&L For Dry River Sand, Laid In Trenches For Cable Protection, As 15Cm Thick Below The Cable And 8Cm Thick Above The Cable After Laying, Complete All As Specified And Directed.Note :- Punned Thickness Of Sand Shall Be Measured And Paid. 65 Supply & Laying Reinforced Precast Concrete Cable Cover, Class Lv, Type 1, Flate Size 250Mm X 150Mm X 40Mm, Confirming To Is 5820-1970, Complete All As Specified And Directed. 66 M&L For 40Mm Bore Light Grade Gi Tubing For Road Crossing And Cable Protection Or Fixed Alongwith Pole With Suitable Ms Clamps, Complete All As Specified And Directed.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 49460.0 /-
Tender Value
INR 24.73 Lakhs /-

BOQ Items

Name of Work :PROVN OF STORAGE ACCOMMODATION FOR AGE (I) (P) AT OAF, SRINAGAR.
Sl. No. Item Description
1Excavation in trenches, not exc. 1.5 mtr wide and not exc 1.5 mtr deep and getting out in any type of soil for foundation, laying of cables/pipe etc, complete all as specified and directed.
2M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
3M&L for RCC M-25 Grade (Design Mix) as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc. basement slabs, under reamed piles, complete all as specified and directed.
4M&L for RCC M-25 Grade (Design mix) as in columns, pillars, peirs, posts and struts, complete all as specified and directed.
5M&L for RCC M-25 Grade (Design mix) as in beams, lintels, over 1.5 mtr clear span etc, complete all as specified and directed.
6Use and waste formwork to sides of rough finished surfaces of concrete foundation, footing, bases of columns, plinth beam, side and soffits of plinth beam and similar work, complete all as specified and directed.
7Use and waste formwork to rough finished surfaces of concrete sides of columns, pillars as in square, rectangular or polygonal etc, complete all as specified and directed.
8Use and waste formwork to rough finished concrete surfaces,sides and soffits of floor or roof beams, lintel beams, cantilevers, shelves etc, complete all as specified and directed.
9M&L for brick work with sub class "B" bricks (old size), straight or curved on plan exc 6 mtr mean radius, built in CM 1:6, complete all as specified and directed.
10M&L for 10mm thick rendering on brick work or concrete surfaces of internal wall in CM 1:6, finished the surface even and smooth without using extra cement, complete all as specified and directed.
11M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work, concrete block masonry or concrete surface, finished the surface even and smooth without using extra cement, complete all as specified and directed.
12M&L for preparation of newly plastered surface of walls and applying three coats white wash, complete all as specified and directed.
13M&L for preparation of newly plastered surface of walls and applying two coats of cement base paint over a coat of wall primer, complete all as specified and directed.
14M&L for moorum/red bajari, filling in floors or pavings, laid in layers not exc. 15cm thick, spread, levelled and rammed including watering, complete all as specified and directed.
15M&L for hardcore of broken stone or boulders of gauge not exc. 63mm, deposited, spread and levelled in layers not exc. 15cm thick, watered and rammed to a true surface, complete all as specified and directed.
16M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base of floor, complete all as specified and directed.
17M&L for machine cut, mirror polished kota stone slab flooring 18-20mm thick, laid over and including 20mm thick screed bed in CM 1:6 and jointed and pointed with grey cement slury mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and directed.
18All as per item No 17.00 here-in-above but as in skirting of floor and fixed over 15mm thick plaster in CM 1:3, complete all as specified and directed.
19S&F steel windows with side hung shutters including box type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
20S&F 3mm thick plain sheet glass, ordinary quality and glazing with oil putty or wooden beads in sqare area not exc 0.50 Sqm in each pane, complete all as specified and directed. Note :- Fixing only rate is included in window/door shutter items considered therein.
21S&F pressed steel frames for doors with one or more rebates includings necessary fixing lugs, hold fasts, hinges, lock stricke plate etc size or section of frame 105mm x 60mm and including two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
22M&L for PCC 1:3:6 type C-0 (using 12.5mm graded crushed stone aggregates) as in back filling of chowkhats, complete all as specified and directed.
23S&F 35mm thick 2nd class hard wood flush door shutters, solid core construction with block board core and plywood face panels, commercial type on both sides, fixed to chowkhat at site, complete all as specified and directed.
24S&F 300mm size aluminium alloy anodised sliding door bolt,ISI marked with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections with fixing bolts and sliding bolt of extruded section, complete all as specified and directed.
25S&F mild steel 200mm long barrel tower bolts, ISI marked, stove enamelled black,complete all as specified and directed.
26S&F mild steel 150mm long barrel tower bolts, ISI marked, stove enamelled black,complete all as specified and directed.
27S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, over all length of cover plate 140mm, complete all as specified and directed.
28M&L for preparation of new wood or wooden based surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
29M&L for preparation of new steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
30M&L for cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggragate) as in lintel upto 1.5 mtr clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, coping, kneelers, apex stones, bed plates, kerbs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
31S&F mild steel rolled section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc, confirming to Fe 410-W-(Gde-E-250) Quality - "A",complete all as specified and directed. Notes :- Fabrication of roof truss, purlins post, rafter etc cutting, welding, bending, or any other nature of work shall be at site or shop and rate for the same shall be included in quoted rate.
32S&F mild steel plates (plain or chequered) channels, square or beams cut or notched (ordinary and counter sunk) forming holes, without any attachments or with riveted, bolted or welded attachments etc. confirming to Fe 410-W-(Gde-E-250) Quality - "A",complete all as specified and directed. Notes :- Cutting to required size and welding or bolting to beam, post, rafter shall be at site, rate for the same shall be included in quoted rate.
33S&F mild steel bolts 20-25mm dia, purpose made with hexagonal or square head one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long, complete all as specified and directed.
34S&F 0.50mm thick prepainted galvalume aluminium zinc coating GI based corrugated steel sheet of an colour having tensile strength of 550 Mpa minimum yeiled strength as in roof covering/cladding to wall, it shall be caoted withhot dip alloy of 55% aluminium, 43.5% zinc, 1.5% silicon and finished with resin coat on both surface @ 150 gm/Sqm of coating as specified and shall be fixed with hot dip galvanised, seld drilling and self tapping screws neoprened and EPDM washers as in roof covering, complete all as specified and directed.
35S&F 0.50mm thick prepainted galvalume aluminium zinc coating GI based plain steel sheet of an colour having tensile strength of 550 Mpa minimum yeiled strength as in roof covering/cladding to wall, it shall be caoted withhot dip alloy of 55% aluminium, 43.5% zinc, 1.5% silicon and finished with resin coat on both surface @ 150 gm/Sqm of coating as specified and shall be fixed with hot dip galvanised, seld drilling and self tapping screws neoprened and EPDM washers as in roof covering, complete all as specified and directed.
36Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25cm thick, complete all as specified and directed.
37Removing excavated material/soils to a distance not exc. 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed.
38S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape as required including cracking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed.
39All as per ser item No 38.00 here-in-above but 5mm dia and over upto and including 10mm dia in stirrups, spaces and binders.
40S&F anodised aluminium snap grid frame work for false ceiling including hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size, 60mm long and expansion hold fasteners 12.5mm dia, 40mm long, complete all as specified and directed.
41S&F 6mm thick asbestos cement building boards, plain, complete all as specified and as per manufacturer"s instructions.
42M&L for mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, raillings, staging for water tanks and similar work, confirming to Fe-290 Gde E-165, complete all as specified and directed.
43Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and directed.
44M&L for machine pressed precast concrete interlocking paver block of any shape and size, confirming to IS : 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment, laid over and including 25mm thick sand cushioning, complete all as specified and directed.
45M&L for 75mm thick cement concrete 1:3:6 type C-1 (using 20mm graded crushed crushed stone aggragates) as in plinth protection and paving, laid in slope, finished the surface even and fair including making joints at every 2.5 mtr and at corner and filled with bitumen 85/25 and sand in ratio 1:2, complete all as specified and directed.
46M&L for point wiring (concealed type) with 1.5 Sqmm copper conductor (multistranded) PVC insulated and unsheatheted FRLS electric cable 1100 volts grade wiring in PVC conduit of suitable size with all fittings & accessories and including PVC insulated electric cable 1100 volts 1.5 Sqmm (multistranded) copper conductor single core (Green colour) cable as continuous earth wire conncted to common earth dolly including sunk sheet terminal box made out of 1.6mm thick MS sheet, covered with 3mm thick plastic laminated sheet for one light point/fan point controlled by one switch 5 Amp, complete all as specified and directed.
47All as per ser item No 46.00 here-in-above but for one 3 pin 5 Amp socket outlet on the independent.
48All as per ser item No 46.00 here-in-above but for one 3 pin 5 Amp socket outlet on the same board with other switches.
49All as per ser item No 46.00 here-in-above but for one socket outlet 15 Amps on the independent board with 2.5 Sqmm copper conductor multistanded FRLS PVC insulated and sheathed electric cable 1100 Volts grade including PVC insulated and unsheathed FRLS electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly.
50S&F switch piano, flush type, 5 Amp, one way, 15 Amp, complete all as specified and directed.
51S&F socket outlet 2 in 1, 3 pin, 5 Amps, flush type,complete all as specified and directed.
52S&F switch socket combination outlet 5 and 15 Amp, 2 in 1, 5 pin, flush type, complete all as specified and directed.
53S&F switch socket combination outlet 5 Amp, 2 in 1 pin, flush type, complete all as specified and directed.
54S&F ceiling rose 3 terminal, size 65mm x 50mm, surface bakelite, complete all as specified and directed.
55S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc, complete all as specified and directed.
56S&F LED light fitting 1 x 20 Watt, 4 feet long 220 Volts, AC, decorative box type with driven, holder including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed.
57S&F LED street light fitting 35 Watt, 230 Volt, AC, outdoor type with high pressure die cast aluminium housing and heat resistant complete with driven, lamp bracket with impact and corrosion resistant including thermal management in multiple optics compete with IP 65/66 protection, complete all as specified and directed.
58S&F ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 Volt, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) and all accessories including connecting up with 3 core flexible coper conductor cable of suitable size from ceiling rose, complete all as specified and directed.
59S&F sheet metal enclosure, factory made double door shutter for DB SPN, 240 Volts, 8 ways with 200 Amps rated bus bar, neutral link, earth bar, complete all as specified and directed.
60S&F MCB SPN 32 Amps, 230 Volts "C" curve, 50 Hz, AC, 10 KA, complete all as specified and directed.
61S&F MCB SPN 5 to 32 Amps, 230 Volts "C" curve, 50 Hz, AC, 10 KA, complete all as specified and directed.
62M&L for earthing complete with galvanised mild steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with GI wire 4mm dia by means of lugs, bolts, nuts, check nuts, washers of galvanised iron or steel, GI protection pipe of 15mm bore, light grade including earth work, earth plate surround by 15cm thick packed layer of charcoal and common salt alternatively upto 90cm, 20mm bore GI watering pipe medium grade, GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B-1 duly reinforced with TMT bars 8mm dia at the rate of 150mm center to centre spacing in both way with suitable lifting handle and pit/ chamber in PCC 1:3:6 type C-1, for pit cover and connecting to main switch board / Main DB’s including testing on completion,complete all as shown in electric plate No. 3 of SSR Part-I and directed.
63Supply & laying XLPE insulated, armoured heavy duty electric power cable with aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm 2 core, complete all as specified and directed.
64M&L for dry river sand, laid in trenches for cable protection, as 15cm thick below the cable and 8cm thick above the cable after laying, complete all as specified and directed. Note :- Punned thickness of sand shall be measured and paid.
65Supply & laying reinforced precast concrete cable cover, class LV, type 1, flate size 250mm x 150mm x 40mm, confirming to IS 5820-1970, complete all as specified and directed.
66M&L for 40mm bore light grade GI tubing for road crossing and cable protection or fixed alongwith pole with suitable MS clamps, complete all as specified and directed.