Military Engineer Services-MES has published Tender For Repair And Maintenance Of Summer Appliance And Voltage Stabilizer At Fatehgarh Cantt. Submission Date for this Tender is 28-01-2023. Voltage Stabiliser Tenders in fatehgarh Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 14-Jan-2023 | Amendment to tender Docu | Other | 21-01-2023 |
2 | 21-Jan-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 28-01-2023 |
Sl. No. | Item Description |
1 | Taking out/dismantlingdefected window/ split type air conditioner of any make and capacity from various locations (irrespective of height) and transporting to contractor workshop to carry out necessary repair as required by replacing the unserviceable parts with new one including cleaning the airconditioner with water and air fresher and refixing the same on various locations as directed after repairing including testings onload at site complete all as specified and directed. Note: All spares, fan motors, relay, capacitor, overload etc shall be measured and paidseparately underrespective supply onlyitems. |
2 | Servicing of walk-in-cooler suitable for medicines of desired temprature range of 6+-2 degree C with evaporater, condenser unit 10,000 BTU/Hr of Capacity 2TR compete all as specified and dircted. |
3 | Dismantling / taking out unserviceable burnt sealed compressor unit 1.5/2.0 TR from air conditioner and fixing the hermetically sealed rotary type compressor new unit of any capacity including necessary brazing the same with existing refrigerant pipe, supply and charging refrigerant gas including testing all as specified and directed by engineer incharge Note: (i) Hermetically Sealedcompressor shall be measured and paid separately under supply only. |
4 | Supply only hermetically sealed rotary type compressor unit of capacity 2.0 TR complete all as specified and directed. |
5 | Supply only FHP (Frictional Horse Power) motor of capacity 1/5 to 1/18 single phase 920 RMP with starting and running capacitor suitable for Window Type AC complete all as specified and directed. |
6 | Supply only Running Capacitor 36-60 MFD all as specified and directed |
7 | Supply only starting relay suitable for 1.0/1.5/2.0TR compressor all as specified and directed. (Make: HI-tech/Classic or as per recommended by manufacture or equivalent as approved by AGE(I).) |
8 | S&F in replacement of Thermostat suitable for ACs of all type (Split/Window) complete all as specified and directed. |
9 | Supply only Cooling Fan Blade suitable for window type AC/ Split AC of any make & capacityall as specified and directed. |
10 | Supply only of Blower Fan Motor suitable for Split AC (Outdoor side) of any capacity & make all as specified and directed. |
11 | Supply onlyPCB for a Window AC 1.5 TR capacity & make recommended by the manufacturer and as directed. |
12 | Supply onlyPCB for a split type AC 1.5/2.0 TR capacity & make recommended by the manufacturer and as directed. |
13 | Supply only ML-1 contactor 240 volt, 25 Amp for split type AC 1.5/2.0 TR complete all as specified and directed |
14 | Supply only cooling coil suitable for split type AC of capacity 1.5/2.0 TRpart all as specified and directed |
15 | Supply only condensening/cooling coil suitable for window type AC 1.5/2.0 TR Air conditioner for suitabel welding complete. |
16 | supply Only Insulation Pipe for copper tube (White / Black Colour) of 1/4"" & 1/2" as per site requirement and all as directed |
17 | Supply only copper tube 3/4"" as per site requirement and all as directed. |
18 | Supply only copper tube 1/4"" as per site requirement and all as directed |
19 | M & L for rewinding of stator of FHP motor of size 1/5 to 1/18 single phase 920 RPM with super quality of copper wire of existing size complete with varnishing, backing, testing including painting with one coat of synthetic enameled back paint complete all as specified and directed. |
20 | M&L for charging of Refrigerant Gas (R-134A/R-22/R-410A/R-32) in window/Split Type Air conditioners 1.5/2.0 TR at site/contractor"s workshop including all necessary work such as cost of refrigerant, welding to refrigerant pipe line, copper pipe etc and testing complete. |
21 | Taking out old U/S voltage stabilizers of capacity 1 KVA to 5 KVA from MES store/site and repair the same in MES work shop (if the transformer found burnt, thesame shall be re-winded in the workshop of contractor as directed. |
22 | S&F Main Relay 24 volts 25 Amps etc complete all as specified and directed. |
23 | S&F Main Control Circuit (PCB) etc all as specified and directed. |
24 | S&F in replacement Sheet Metal Enclosure with metal clad socket and earth plug with one number MCB 20/32 Amp including connecting complete all as specified. |
25 | Taking out old unserviceable burnt sealed compressor from Refrigerator/Deep freezer and fixing the new hermetically sealed complressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing all as specified and directed. Note: (i)Hermetically sealedcompressor shall be measured and paid separately under supply only item. |
26 | Supply only hermetically sealed compressor suitable for refrigerator/Deep freezer of capacity 80 Ltr/165 Ltr/286 Ltr/310 Ltr. |
27 | S&F Relay suitable for refrigerator/Deep freezer 165/286/310 Ltr capacityall as specified and directed. |
28 | Supply & FixingPCB for Refrigerator/Deep freezer 165/286/310 Ltr capacity & make recommended by the manufacturer and as directed. |
29 | S&F in replacement of Thermostat suitable for refrigerator/Deep freezer 165/286/310 Ltr capacity complete all as specified and directed. |
30 | M&L for Gas charging of refrigerators/deep freezers of any capacity at site or contractor"s workshop with necessary gas (R-12 / R-134A gas), filter, anti moist and soldering/Brazing etc complete all as specified and directed. |
31 | Dismantling / taking out unserviceable burnt sealed unit of compressor from water coolers any make and capacity and fixing new hermetically sealed compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply and charging refrigerant gas including testing all as specified and directed by engineer incharge. Note: (i) Hermetically Sealed compressor shall be measured and paid separately under supply only. |
32 | Supply only new sealed unit compressor suitable for water cooler 40/80 Ltr complete all aspecified and directed. |
33 | Supply & Fixing of FHP motor with suitable Fan Blade Single Phase 1/8 to 1/35 HP suitable for up to 150 Ltr capacity water coolers including testing all as specified and directed. |
34 | Taking out water cooler of any make and capacity from position and cleaning the complete condenser coil & storage tank with chemical base solution and soda water including servicing, oiling, of FHP motor checking of electrical & water supply connection and re-fixing the same on its original position and testing complete. |
35 | S&F in replacement of starting capacitor 80-100 MFDall as specified and directed. |
36 | S&F in replacement of Relay & OLP suitable for water cooler of any make & capacity complete all as specified and directed. |
37 | S&F in replacement of Thermostat switch suitable for water cooler complete all as specified and directed. |
38 | S&F in replacement of running capacitor 4 MFD 230 volts 50 Hzs AC suitable for water cooler and desert cooler including taking out old capacitor complete all as specified and directed. |
39 | M&L for gas charging of water cooler of any capacity and including refrigerant gas (R-12/R-134A) as directed at site or contractor workshop as directed including necessary work such as pipe line etc and testing complete. |
40 | S&F in replacement of condenser coil complete with copper capillary tube and aluminium fins for water cooler of any make and capacity complete. |
41 | S&F in replacementHoneycomb Cooling Pad for desert cooler of existing make complete all as specified and directed. |
42 | S&F in replacement of wood wool pad 15mm thick made out of chicken wire mesh filled with fine quality wood wool and stitched with Gi wire for desert cooler of any make complete all as specified and directed. |
43 | S&F in replacement of front grill Air diverter of PVC with selector switch and 2 No indicator for Desert cooler of any make and capacity complete all as specified and directed. |
44 | M&L for rewinding of stator of exhaust fan/kit fan 18" sweep 900 RPM of any make with super quality of winding copper wire of existing size complete with varnishing, backing, testing including painting with synthetic enameled paint of gray colour complete all as specifieda and directed. |
45 | Supply and fixing in replacement of submersible water lifting pump of capacity 1.25 m head, 230 Volts complete all as specified and directed. |
46 | S&F in replacement of Kit fan motor 450 mm sweep 1350/1400 RPM.Complete all as specified and directed. (Make: Everest/Summer Cool/Khaitan ) |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy