Housing Urban and Rular Development Boards / Undertakings / PSU Closing in 0 days TDR #35531556

Tender For Repair And Maintenance Of Internal And External Part Of Building Of Type I, Type-Ii And Type-Iii Residential Building Of Ps/Pc Bhajanpura, North-East District.

Issued by Boards / Undertakings / PSU · bhajanpura, Delhi
Tender Value
86.72 Lakhs
Estimated cost
Bid Submission
21 Jan 2023
0 days left
EMD
1.73 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
bhajanpura → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair And Maintenance Of Internal And External Part Of Building Of Type I, Type-Ii And Type-Iii Residential Building Of Ps/Pc Bhajanpura, North-East District.

BOQ

Name of Work: Repair and maintenance of Internal and external part of building of Type I, Type-II & Type-III Residential building of PS/PC Bhajanpura,North east district.
Sl. No. Item Description
1By Mechanical Transport including loading,unloading and stacking
2Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more.
3Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.
4Beyond 30 cm girth upto and including 60 cm girth
5Beyond 60 cm girth upto and including 120 cm girth
6Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
7Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
8With Chlorpyriphos E.C. 20% with 1% concentration
9Extra for levelling & neatly dressing of disposed soil completely asdirected by Engineer-in-charge.
10Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing :
111:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources).
12Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
13Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
14Centering and shuttering including strutting, propping etc. and removal of form for
15Suspended floors, roofs, landings, balconies and access platform
16Shelves (Cast in situ)
17Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
18Thermo-Mechanically Treated bars of grade Fe-500D or more
19Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
20Cement mortar 1:6 (1 cement : 6 coarse sand)
21Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
22Cement mortar 1:3 (1 cement :3 coarse sand)
23Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
24Granite stone slab colour black, Cherry/Ruby red
25Area of slab upto 0.50 sqm
26Area of slab over 0.50 sqm
27Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
28Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
29Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
30Kiln seasoned and chemically treated hollock wood
31Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.
32Kiln seasoned and chemically treated hollock wood
3335 mm thick
34Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
3535 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
36Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I)
37On one side only
38Extra for providing lipping with 2nd class teak wood battens 25 mmminimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
39Providing and fixing wire gauge shutters using galvanized M.S. wiregauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :
4030 mm thick shutters
41With ISI marked stainless steel butt hinges of required size
42Kiln seasoned and chemically treated hollock wood
43Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
44Fixed to openings /wooden frames with rawl plugs screws etc.
45Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
46150x10 mm
47100x10 mm
48Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
49125 mm
50100 mm
51Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Framesof cross-section 90 mm x 45 mm having single rebate of 32 mm x 15mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
52Providing and fixing to existing door frames.
5330 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
54Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge
55Providing and fixing wire gauge shutters using stainless steel grade 304wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws :
5630 mm thick shutters
57With ISI marked stainless steel butt hinges of required size
58Kiln seasoned and chemically treated hollock wood
59Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
60In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
61Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete.
62Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
63Size of Tile 600x600 mm
64Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10 mm and down gauge), includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as perstandard design :
65In 75x75 mm deep chase
66Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
67110 mm diameter
68Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion.
69Bend 87.5°
70110 mm bend
7112 mm cement plaster of mix :
721:4 (1 cement: 4 fine sand)
7315 mm cement plaster:
741:6 (1 cement: 6 coarse sand)
7518 mm cement plaster in two coats under layer 12 mm thick cementvplaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge
76Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification.
77Two or more coats on new work
78Finishing walls with Acrylic Smooth exterior paint of required shade :
79New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
80Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
81Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
82Two or more coats on new work
83Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
84Applying priming coats with primer of approved brand andmanufacture, having low VOC (Volatile Organic Compound ) content.
85With water thinnable cement primer on wall surfacehaving VOC content less than 50 grams/litre
86Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
87With cement mortar 1:4 (1 cement : 4 fine sand)
88Renewing glass panes and refixing existing wooden fillets:
89Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm)
90Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding
91Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge.
92Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in Charge
93Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineerin- Charge.
94Internal Work- Exposed on wall
95Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
96Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
97Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
98Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge
99Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :
100Of area 3 sq. metres and below
101Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
102For thickness of tiles 10 mm to 25 mm
103Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge:
104Up to 150 mm diameter
105Dismantling of flushing cistern of all types C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
106Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
107Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
108Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever) conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required:
109White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests
110Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
111W.C. pan with ISI marked white solid plastic seat and lid
112Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-
113White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
114Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
115Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
116Kitchen sink with drain board
117510x1040 mm bowl depth 250 mm
118Kitchen sink without drain board
119610x510 mm bowl depth 200 m
120Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
121Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
122Flexible pipe
12340 mm dia
124Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
125Providing and fixing soil, waste and vent pipes :
126100 mm dia
127Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
12875 mm diameter :
129Centrifugally cast (spun) iron socketed pipe as per IS: 3989
130Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :
13175 mm dia pipe
132100 mm dia pipe
133Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
134100 mm dia
135Sand cast iron S&S as per IS - 3989
13675 mm dia
137Sand cast iron S&S as per IS- 3989
138Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
139100 mm inlet and 75 mm outlet
140Sand cast iron S&S as per IS - 3989
141Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
14220 mm nominal dia Pipes
14325 mm nominal dia Pipes
144Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
14525 mm nominal dia Pipes
14632 mm nominal dia Pipes
147Providing and fixing uplasticised PVC connection pipe with brass unions :
14845 cm length
14915 mm nominal bore
150Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
151100 mm diameter
152Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
153Providing and fixing C.P. brass bib cock of approved quality conformingto IS:8931 :
15415 mm nominal bore
155Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
15615 mm nominal bore
157Providing and fixing C.P. brass stop cock (concealed) of standarddesign and of approved make conforming to IS:8931.
15815 mm nominal bor
159Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
16015mm nominal bore
161Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
162Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
163150 mm diameter S.W. pipe
164Providing and fixing square-mouth S.W. gully trap class SP-1complete with C.I. grating brick masonry chamber with water tightC.I. cover with frame of 300 x300 mm size (inside) the weight ofcover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design:
165100x100 mm size P type
166With common burnt clay F.P.S. (non modular)bricks of class designation 7.5
167Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps :
168100 mm diameter
169Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :
170First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.
171Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
172The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
173Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs,terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for aminimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
174With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
175Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge.
17675mm average thickness
177Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of \"L\" shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge.
178Providing and fixing 600 mm CP brass towel rail including all fittings and fixtures etc.complete.
179Providing and fixing G.I. 50mm dia tank nipple for water tank pipe, fitting of approved quality and colour directions of Engineer-in-charge.
180Removing the plants and bush from roots at the roof and wall surface and providing proper acid treatment to avoid future growth including dismentaling/demolishing the wall/roof slab (upto 0.3 cum) and repairing the same (Brick work with Cement mortar 1:6 (1 cement : 6 coarse sand)/ R.C.C. with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)). , all complete as per instruction of Engineer -in- charge.
181Credit fpr Dismantle/old/Unserviceable steel like M.S. Grill, M.S. Gate, M.S. Window, C.I, M.S. Girder, M.S. Angle and IRC Fabric etc. all complete as per direction of the Engineer-in-Charge.
182Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
183Group A
184Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
185Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
186Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
187Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
188(i)2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
189(ii)2 X 6 sq. mm + 1 X 6 sq. mm earth wire
190Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
191i) 3 x 1.5 sq. mm
192ii) 3 x 4 sq. mm
193iii) 3 X 6 sq. mm
194Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
195(i) 20 mm
196(ii) 25 mm
197Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
198Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1991 or 2 Module (75 mmX75 mm)
200Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
201Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
202Supplying and fixing call bell/buzzer suitable for DC/AC single phase 230 volts, complete as required as per the direction of engg -in- charges.
203Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required.
204Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
205Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt. Confirming to IP 66 protection complete in all respect. ( Makes : Philips / GE/ Havells/ Wipro/ Crompton/Jaquar )
206Supply, installation, testing and commissioning of 1200 mm (nominal size), 30 watt / 36 watt LED batten luminaire in aluminium housing with minimum light output 100 lumen/watt complete with all accessories, electronic driver,diffuser, directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.( Makes : Philips / GE/ Havells/ Wipro/ Crompton/Jaquar )
207Supply, installation, testing and commissioning of 12 Watt /15 Watt surface mountedLED downlighter luminairecomplete with all accessories and electronic driver, directly on ceiling / wall, including connections etc. as required. Makes : Philips / GE/ Havells/ Wipro/ Crompton/Jaquar)
208Supply, installation, testing and commissioning ofwallmounted light fixture complete with B22 base, diffuser and15 watt LED blub etc as requireddirectly onwall, including connections etc. as required.(Approved Makes:- Havells City 3 Wall light /orequivalent model Philips / Wipro/ Crompton /Jaquar)
209Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in recess etc. as required.
2106 Module
211Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
21210 Amp Modular switch
21320 Amp Modular switch
2143 pin 10 Amp socket outlet
2156 pin 20/25 Amp Socket outlet
216Supplying and fixing PolycarbonateBattan/Angle holder with 8/10 watt LED bulbincluding connection etc. as required.
217Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
21863 Amp
219100 Amp
220Supply, installation, testing and commissioning of 10 watt LED bulkhead fittings with IP 66 ingress protection complete with all accessories and electronic driver, etc as requireddirectly onwall, including connections etc. as required.Makes : Philips / CG/ Havells/ Wipro/ Crompton/Jaquar )
221Supply, installation, testing and commissioning of 600 mm (nominal size) 9/10 watt LED batten luminaire with minimum light output 100 lumen/watt complete with all accessories, electronic driver,diffuser, directly on ceiling/ wall, including connectionsetc. as required.( Approved Makes :- Wipro Garnet 10W LED Batten or equivalent model of Havells/ Crompton / Philpis / GE)
222Supplying, Installation, testing and commissioning ofBEE 5 star rated, 1200 mm sweepceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. Makes :- Crompton /Havell\"s / Usha / Orient )
223Supplying, installation, testing and commissioning of 30 W LED based Flood light luminaire,housing made up of pressure die cast aluminium / aluminium alloy, complete withdriver, cover andmountingbracket etc including installation directly onwall andconnection with 3 X1.5 sq.mm FRLS PVC insulated copper wire etc as required. The fixture should have a minimum system efficacy of 100 lumen/Watt, ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK >=05.The fixture driver should have an operating voltage range of 140-270 V, surge protection of >=3KV, PF >0.9 and THD<20%. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance.LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. (Approved Make: Phillips MODEL NO.BVP120 LED 35 CW FG S1 PSU GR OR similar in Schreder/ Lighting Science / GE/ Philips/ Jaquar )
224Supplying and installation of 300 mm sweep, 1400 RPM heavy dutyexhaust fan complete with louvers/shutters in the existing opening, including making the hole to suit the size of the above fan and making good the damage, connection, testing, commissioning etc. as required.(Havells makeISI markHeavy Duty Exhaust Fan or with similar specifications Crompton/Havells / Orient / Usha / Almonard)
225Supplying and installation of fresh air fanwith louver shutter 250 mm sweep in the existing opening including making the hole to suit the size of the above fan and making good the damage, connection, testing , commissioning etc as required.(Havells make Ventil Air-DX with self opening louvers or with similar specifications CG / Orient / Usha / Almonard/Havells )
226Painting of MS street light poles with one or more coat with superior quality super enamelled outdoor paint complete with rubbing the surface with ragmal and making the suface smooth after painting with silvar colour or the colour as per direction of engg in charge.
227Painting of MS Feeder Pillars/sub feeder pillarwith one or more coat with superior quality super enamelled outdoor paint complete with rubbing the surface with ragmal and making the suface even after painting with smoke gray colour or the colour as per direction of engg in charge.
228Repair of feeder pillar with wealding, repair/replacement of hing , damage MS portion complete as reqd.
229Routine servicing of main electric control pannel board complete in all respect
230Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
23112 way , Double door
232Supplying and fixing 5 amps to 32 amps, 240 Volts \"C\" series MCB\"s suitable for lighting and other loads of following poles in the existing MCB DB complete with connection, testing and commissioning etc as reqd. .
233a) Single Pole
234b) Double Pole
235Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required
236100 A, 16 KA,TPMCCB
237125 A, 16 KA,TPMCCB
238200 A, 25 KA,TPMCCB
239Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required..
240Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling etc as required.
241Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required
242Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
243Providing and fixing following sizesof sunmica sheet, with screw etc. as required with complete in all respects.
2444x4 inch
2457x4inch
2468x6 inch
2478x10 inch
24810x12 inch
249Dismentling of old surface / recessed wiring and distribution board of 01 no Type - III qtr and making the damage good etc as required as per direction of engineer-in-charge.
250Less for cost of dismental material retrieve from the Qtr/ buildings which will be kept by the contractor i.c Cu/Al conductor PVC insulated wire, switch box, PVC/MS conduit pipe, accessories, Old fans and other electrical fitments etc complete as reqd.

AI Tender Summary

OUR REF NO 35531556
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 86.72 Lakhs
LAST DATE 21-01-2023
Authority
Authority Name Housing Department
Work Description Repair And Maintenance Of Internal And External Part Of Building Of Type I, Type-Ii And Type-Iii Residential Building Of Ps/Pc Bhajanpura, North-East District.
Basic Detail
Tender No 127/DPHCL/ENGG/NIT/2022-23
Bidding Type Tender
Location
City bhajanpura
State Delhi
Key Dates
Publish Date 30 Dec 2022
Submission Date 21 Jan 2023
Open Date 23 Jan 2023
Finance
Tender Value 86.72 Lakhs
Tender Fee Ref. Documents
EMD 1.73 Lakhs
Exemption Not Available
Document List
31301f3e-7dd4-4651-a50b-7ce3a56ce469.html
BOQ_153013.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 30, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 21, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 23, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

31301f3e-7dd4-4651-a50b-7ce3a56ce469.html

xls

BOQ_153013.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders