Tender For Electrical Wiring And U.G Cable Replacement Work Of Powerhouse, Staff Quarters, Pump House, Meter Room At Dariapur Lighthouse, West Bengal.
Tender Value
7.87 Lakhs
Estimated cost
Bid Submission
16 Jan 2023
0 days left
EMD
15750
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
dariapur → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Electrical Wiring And U.G Cable Replacement Work Of Powerhouse, Staff Quarters, Pump House, Meter Room At Dariapur Lighthouse, West Bengal.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and fixing following size/ modules GI box/ PVC surface box alongwith modular base & cover plate for modular switches in recess/surface etc. as required. |
| 2 | 2 Module (75mm * 75mm) |
| 3 | 3 Module (100mm * 75mm) |
| 4 | 4 Module (125mm * 75mm) |
| 5 | 6 Module (200mm * 75mm) |
| 6 | 8 Module (200mm * 75mm) |
| 7 | 12 Module (200mm * 150mm) |
| 8 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 9 | 10 Amp switch |
| 10 | 2-way, 10 amp switch |
| 11 | 16/20 Amp switch |
| 12 | 3 pin 10 Amp socket outlet |
| 13 | 6 pin 16/20 Amp socket outlet |
| 14 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 15 | Supplying & fixing pvc batten/ angle holder including connection etc as required. |
| 16 | Installation , testing, commissioning of wall bracket/ celling fittings of all sizes and shapes containing upto two GLS/CFL/LED/ surfacelamps per fitting, complete with all accessories including connection etc as required. |
| 17 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 18 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 19 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 20 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 21 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 22 | Upto 450 mm Sweep |
| 23 | Supplying and fixing of following sizes of medium class PVC conduit /Casing capping along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 24 | 25 mm (PVC Casing Capping) |
| 25 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 26 | 3 x 1.5 sq. mm (33 coil of 90 mtrs) |
| 27 | 3 x 2.5 sq. mm (15 coil of 90 mtrs) |
| 28 | 3 x 4 sq. mm (4 coil of 90 mtrs) |
| 29 | 3 x 6 sq. mm (1 coil of 90 mtrs) |
| 30 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted\ including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 31 | 6 way, Double door |
| 32 | 8 way, Double door |
| 33 | 12 way, Double door |
| 34 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 35 | Single pole 6A/10A/16A (5 nos, 10 nos, 10 nos) |
| 36 | Double pole 32A |
| 37 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering and end to end connection. |
| 38 | up to 35 sq mm. |
| 39 | Earthing with G.I earth pipe 4.5 metre long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 40 | Providing and laying earth connection from earth electrode with 6 SWG dia GI wire in 15 mm diaG.I.Pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 41 | LED tube light batten, 20 watt, 4-feet. |
| 42 | 12 watt LED surface light for indoor. Round, white light. |
| 43 | Exhaust Fan 300mm, metal blade, heavy duty industrial type. |
| 44 | Wall mounting revolving fan. 400 mm sweep. |
| 45 | LED lamp 15 watt. B-22 holder. |
| 46 | 15 Watt LED bulkhead fitting for outdoor purpose. |
| 47 | Ceiling Fan with Sweep 1200mm and Hight performance even at low voltage. |
| 48 | 2.5 sq mm, 3-core, PVC copper armoured U.G cable. |
| 49 | Supply and fixing of 100 Amp, 440 Volt, porcelain kit kat fuse unit. |
| 50 | Digital multimeter with clamp tester. |
| 51 | Earth testeranalog, rotary type with kit (0.01-0.1 -10 -100 ohms) |
| 52 | 30 watt, LED street light fitting. |
| 53 | Supply of 24 Volt, 260 watt Solar photovoltaic module. |
| 54 | Supply and fixing of 50 Amp copper , 3-phase bus bar chamber with connection. |
| 55 | Supply and fixing of 63 Amp 3-phase, 440 volt ON/OFF rotary main switch with box with indicators. |
| 56 | Indicator 1-Modular. Make- Reputed |
| 57 | PVC 4X4 square Junction Box. |
| 58 | Insulation Tape 5 mtr roll. |
| 59 | Labour charges for removing of existing channel wiring complete including switch board, pipes,fittings, MCB boxes etc. |
AI Tender Summary
Tender Timeline
Dec 30, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedJan 16, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 17, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender