Tender For Repair Maintenance Of Tower Acs Misc Other Air Conditioning Works And Summer Appliances At Naval Officers Mess Under Ge (U) Pm Delhi Cantt-10., delhi-Delhi

Military Engineer Services-MES has published Tender For Repair Maintenance Of Tower Acs Misc Other Air Conditioning Works And Summer Appliances At Naval Officers Mess Under Ge (U) Pm Delhi Cantt-10.. Submission Date for this Tender is 26-01-2023. Air Conditioner Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

35516989
Corrigendum : Tender For Repair Maintenance Of Tower Acs Misc Other Air Conditioning Works And Summer Appliances At Naval Officers Mess Under Ge (U) Pm Delhi Cantt-10.
Open Tender
Indian
Delhi
delhi
26-01-2023

Tender Details

Repair Maintenance Of Tower Acs Misc Other Air Conditioning Works And Summer Appliances At Naval Officers Mess Under Ge ( U ) Pm Delhi Cantt-10.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 90120.0 /-
Tender Value
INR 45.06 Lakhs /-

BOQ Items

Name of Work: REPAIR/ MAINTENANCE OF TOWER ACS MISC OTHER AIR CONDITIONING WORKSAND SUMMER APPLIANCES AT NAVAL OFFICERS MESS UNDER GE (U) P&M DELHI CANTT-10.
Sl. No. Item Description
1Taking downoftower type AC 4 TR Capacityincluding cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing connections from heating mode to cooling mode or vice-versa andkeepingthe AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing positioncomplete all specified and as directed by Engineer-in-Charge. Notes :- (i) Replacement of defectivespares for making the AC units in satisfactory working conditionwill be measured & paidseparately under relevant items and Labour charges for taking out old spares & refixing of new sparesshall deemed to be included in unit quoted rate. (ii) Penaltywill be charged for not attending complaint from 12 Hoursto 24 hours Rs. 500/- each complaint. Furtherif complaint not attended and rectifiedwithin 24 hours after intimation (Intimation will be given by message/whats app/mail by mentioningtime of complaint,for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency and double of the job order amount to be deducted from contractors dues.
2Supply and fixing Baimetal overload relay 6-10A. (Make:- L &T /ABB/ Seimens )
3Supply and fixingContractor MNX 12. ( Make:- L &T / ABB/ Seimens )
4Supply & fixing Condenser fan blade of Aluminiumfor towertype A.C of Capacity 4 TR as per Existing size as specified and directed by engineer-in-charge.
5Supply and fixingIn Repair single phase preventer VSP 1. ( Make:- L &T / ABB/ Seimens )
6Disconnecting the main printed circuit board (PCB) and repair the PCB with electric accessories and sensors as per existing suitable for Tower AC of capacity 4 TR and refixing it complete with all testing and commssioning as directed by Engr-in-Charge.
7Supply & fixing in repairs of suction valve set of size 15.9mm (5/8"") for Tower 4 TR capacity complete all as directed by Engr-in-Charge. Note:- Supply & filling of refrigerant gasshall be measured and paid under relevent item.
8Supply & fixing in repairs of Discharge valve set of size 9.52 mm (3/8"") for Tower 4 TR capacity complete all as directed by Engr-in-Charge. (Make:- LG/ Voltas/ Blue Star/ Hitachi). Note:- Supply & filling of refrigerant gasshall be measured and paid under relevent item.
9Supply & fixing in repairs of Expansion valve for tower type AC of capacity 4 TR complete all as directed by Engr-in-Charge. (Make:- Danfos, Emerson, Temsuch)
10Taking down unserviceable reversible valve for split AC of capacity 1.5TR and supply & fixing new reversible valve with solenoid coil including required different copper pipe with PCB and remote alteration/modification complete all as specified and directed by Engr-in-charge. (Make:- LG/ Voltas/ Blue Star/ Hitachi) (Note 01:- Supply & filling of refrigerant gasshall be measured and paid under relevent item.) (Note 02:- various size copper pipe used for this to be included in above quoated artes.) (Note 03:- Any Alteration or modifation including electronic component required in PCB and Remote to be included in above quoated rates.) Note 04:-carryout the pressure test of refrigeration system, detecting leakage and charging the refrigerant gas of matching description as per existingincluding soldering and brazing of leaking copper tubing complete all as specified and directed to be included in above mentioned rates.
11ditto- all as per item No. 10 above but window type Air Conditioner of capacity1.5 TR.
12ditto- all as per item No. 10 above but window type Air Conditioner of capacity2 TR.
13ditto- all as per item No. 10 above but spilt type Air Conditioner of capacity2 TR.
14Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the Tower type Air Conditioner of Cap4 Ton,of any make any type from any location
15Supply , Installingand testing of new sealed unit compressor 4TR for Tower type Air Conditioner of Cap4 Tonalongwith test certificate from manufacturer includingcleaning and removing dust/dirt from the cooling coil condenser coilwith necessary modification of capillary tube etc&Charging of Gas R-22/R-134A/R-410 and commissioning complete all as specified & directed by Engg-in-Charge. (Make:- Emerson /Tecumseh/ Danfos) Note :-1. Gas charging shall be paid spepartely under relevent item. 2. Transportation Charges from siteto trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above.
16Supply & fixing in repairs of air blower motor copper wounded for 4TR capacity towerAC as per existing complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.)
17Disconnecting the mains and taking out the unserviceable condenser coilof Tower AC of capacity 4TR of any make from any location and supply, fixing and testing new condenser coil as per existing size & patterns for complete all as specified & as directed. (Make:- Voltas/Carrier/LG)
18Supply & fixing in repairs of evaporator/cooling coil for tower type Air Conditioner of capacity 4 TRof existing make and size complete all as specified & as directed by Engr-in-Charge.
19Dismantling and removing defective burnt blower unit motor of any capacity and make of indoor units of tower type AC of capacity 4 TR capacity rewinding the motor with enamel copper binding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing all as directed.
20Dismantling and removing defective burnt outdoor unit motor of any capacity and make of indoor units of tower type AC of capacity 4 TR capacity rewinding the motor with enamel copper binding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing all as directed.
21Material and labour for applying POP gypsum paste in hole of wall as directed and specified by engineer in charge.
22Dismantling and Refixing the Split AC of 1.5/2 TR Including Drilling of holes into a brick wall for connecting Indoor with OutDoor Unit’s pipes and Connecting indoor and outdoor units with copper pipes and installation of drainage pipes and Fixing Outdoor unit on separately ODU stand, Temperature & gas pressure testing,gas charging,Carpentry work, Plumbing, masonry & white cementing Note : Drain Pipe, Copper of required size, Refrigenent gas , Outdoor stand , power plug, MCB and Copper wire to be paid under relevent item
23Material and labour in repair for MS iron cross arms, bracing supports , clamps and back plates fabricated from strctural steel sections including nuts, bolts,washers, welding bending cold or hot , drilling holes for bolts in any shape or sizefor outdoor stand/desert cooler stand/ tower ac stand (indoor / Outdoor) as indicated and inclusive of one coat of zinc cromate primer , one under coat & one finishing coat & good quality of aluminium paint all as specified and directed.
24Supply & fixing in Repair Outdoor Unit (ODU) Stand for 4 TR Type tower AC as directed and specified by engineer in charge.
25Supply & fixing in Repair Outdoor Unit (ODU) Stand for 1.5TR/ 2 TR Type split AC as directed and specified by engineer in charge.
26Supply & fixing heavy duty hard copper pipe 10mm (3/8") dia/ bore complete including insulation brazing, welding, nuts,bolts and screws of required size including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.(Make:- Maxflow/mandev/ rajco)
27ditto- all as per item No. 26 above but copper pipe 15mm (5/8") dia/ bore.
28ditto- all as per item No. 26 above but copper pipe 12mm (1/2") dia/ bore.
29ditto- all as per item No. 26 above but copper pipe 6mm (1/4") dia/ bore.
30Taking down unserviceable insulation for copper pipe, supply and fixing new insulation for copper pipes suitabale for tower/Split AC of capacity from 1.5 to 4.0 TR all as specified and directed by Engineer-in-charge.
31Taking down unserviceable UPVC drain pipe and supply & fixing new PVC drain pipe 15 mm dia for Split/window AC all as specified and directed by Engineer-in-charge. (Make:- Prayag/ Supreme/ Prince.)
32Taking down unserviceable UPVC drain pipe and supply & fixing new PVC drain pipe 20 mm dia for Split/window AC all as specified and directed by Engineer-in-charge. (Make:- Prayag/ Supreme/ Prince.)
33Taking down unserviceable UPVC drain pipe and supply & fixing new PVC drain pipe 25 mm dia for Split/window AC all as specified and directed by Engineer-in-charge. (Make:- Prayag/ Supreme/ Prince.)
34Supply and fillingrefrigerant gas R-22/R-32/R-410A/R-134 in window type /Split Type AC/ Tower type unit of capacity 1.5/2//4 TR. (Make : Mefron/Floron/ Refron.)
35Material and labour for detecting the leakage of gas at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting & brazing of copper tubes testing and commissioning complete in satisfactory working condition all as specified and as directed.
36Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded,unsheathed1100 volts grade in PVC casing caping(heavy grade) of adequit size with all fittings and casing capingaccessories of surface type including one run 6 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694)as earth wire including taking down old unservisible sub main wiring complete all as specified and as directed. (Make of cable:-NICCO / FINOLEX / RR KABEL/ HAVELL"S/ POLYCAB / KEI INDUSTRIES LTD and make of Casing caping:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST.)
37Material and labour for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded,unsheathed1100 volts grade in PVC casing caping(heavy grade) of adequit size with all fittings and casing capingaccessories of surface type including one run 4 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694)as earth wire including taking down old unservisible sub main wiring complete all as specified and as directed. (Make of cable:-NICCO / FINOLEX / RR KABEL/ HAVELL"S/ POLYCAB / KEI INDUSTRIES LTD and make of Casing caping:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST.)
38Supply and fixing in repairs of metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 32 Amps including taking down old unserviceable metal clad socket complete all as specified and as directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T)
39Supply and fixing in repairs of MCB TPN415 volts 32 Amps, 16 kA, "C" curve complete all as specified and as directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T)
40Supply & fixing in repair metal clad socket of 20 Amps complete all as specified & as directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T)
41Supply & fixing in repairs metal clad plug with two pin of capacity 20 Ampscomplete all as specified & as directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T)
42Supply & fixing in replacementonly Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver LED tube light fitting 20 watt including LED tube, 230 volt complete all as specified and directed. (Make :Havells cat part No LUMILINEBS9WLED830SPCWH or equivalent model of make Phillips /Surya Roshni Ltd / Bajaj/ Crompton Greaves/ C & S Electric)
43Disconnecting the unserviceable PCB of any make invert AC of capacity 1.5/2 TR and refixing the same after necessary repair of PCB for satisfactory functioning of the AC unit Complete all as specified and as directed.
44Dismantling of existing repairable Non-Inverter/inverter Refrigerators of any make and from its position after disconnecting electric connections, transporting from site to contractor"s workshop for carrying out repairs and renewal/replacement of parts, reassembling and transporting back to the site including installation of the same on the same location and making electric connection etc, all as specified and directed by Engineer-in-Charge. Note :-1. Replacement of defectivespares for making the Refrigerator units in satisfactory working condition will be measured & paidseparately under relevant items and Labour charges for taking out old spares and fixingof new sparesshall deemed to be included in unit rate quoted.
45Supply only capillary tube of existing size including necessary brazing suitable for 165-310 ltrs capacity refrigeratorall as specified and directed. (Make:- As per sample)
46Supply only overload protector relay suitable for 165-310 ltrs capacity refrigerator all as directed. (Make:- Renutrol/ Sri Ram/ Microtech)
47Supply only thermostat suitable for 165-310 ltrs capacity refrigerators all as directed. (Make:-HONEY WELL/ INDFOSS/ RENUTROL /SIEMENS/ DASPASS.)
48Supply only freezer door with spring of refregierators of any capacity all as directed. (Make : Suitable for Whirlpool/ LG/Samsung/ Godrej make refrigerator).
49Supply only vegetable basket with glass suitable for 165-310 ltrs capacity refrigerators all as directed. (Make : Suitable for Whirlpool/ LG/Samsung/ Godrej make refrigerator).
50Supply only PVC defrost tray as per sample suitable for 165-310 ltrs capacity refrigerators. (Make : Suitable for Whirlpool/ LG/Samsung/ Godrej make refrigerator).
51Material and labour for inspection from the authorised repair centre of respective company ( LG/Whirlpool/Samsung) to find out the defects in compressor, PCB, and carrying out the required repair.
52Supply and fillingrefrigerant gas R-134/ R-600 in water co0ler/ refrigerator/ deep freezer of various capacity. (Make :Honeywell/ Sterlin/Duplon.)
53Supply and fixing in replacementinverter type compressor for refrigerators of capacity 225 to 310 ltrs. Make:Emerson/ Tecumseh/LG
54Supply and fixing in replacementPCB compatible suitable for inverter type refrigerators of capacity 225 to 310 ltrs.
55Material and labour for dismantling the existing window type air conditioner complete of capacity 1.5/ 2.0 TR and refixing to any other location after servicing including cutting of window grills, covering the open space of old location and new place of fitting complete all as specified & as directed.
56Supply and fixing in replacement 4mm thick wooden play for exposed space for window AC complete as specifed and directed.
57Supply and fixing in replacement wood wollen pad of suitable size for 24” sweep desert cooler complete all as specified and directed 01 Set comprising of 3 Nos of pads (Make:- As per sample.)
58Supply and fixing in replacement only 3 pin plug top 15 Amp for desert cooler complete all as specified and directed. (Make-Anchor/Kinjal/Havells)
59Supply and fixing inreplacementpump motor 230 Volts, single phase, AC suitable for Plastic body/Steel body Desert cooler complete all as specified & as directed. (Make- cool master/ Crompton Greaves/ Khaitan/ indcool.)
60Supply and fixing in replacement ofdesert cooler kit fan motor, single speed, 230 V, 50 Hz of capacity 90 Watt 1450 RPM, copper wounded including nuts bolts for fixing complete all as specified and directed. (Make : Crompton Greaves/Usha/Khaitan)
61Supply and fixing in replacement Desert cooler exhaust fan motor, single speed, 230 V, 50 Hz of capacity 150 Watt 1400 RPM, copper wounded including nuts bolts for fixing including taking down old unserviceable one complete all as specified and directed.(Make- cool master/ Crompton Greaves/ Khaitan/ indcool.)
62Taking downof split type AC 1.5/2 TR Capacityincluding cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner OR cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing connections from heating mode to cooling mode or vice-versa and keepingthe AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge.
63Taking downofWindow type AC 1.5/2 TR Capacityincluding cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing connections from heating mode to cooling mode or vice-versa andkeepingthe AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing positioncomplete all specified and as directed by Engineer-in-Charge. Notes for Ser Item No 76 & 77 :- (i) Replacement of defectivespares for making the AC units in satisfactory working conditionwill be measured & paidseparately under relevant items and Labour charges for taking out old spares & refixing of new sparesshall deemed to be included in unit quoted rate. (ii) Penaltywill be charged for not attending complaint from 12 Hoursto 24 hours Rs. 500/- each complaint. Furtherif complaint not attended and rectifiedwithin 24 hours after intimation (Intimation will be given by message/whats app/mail by mentioningtime of complaint,for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency and double of the job order amount to be deducted from contractors dues.
64Supply only Running capacitor 36+6 MFD. (Make:- Epcos/ Usha/ Keltron.)
65Supply only Running capacitor 45+5 MFD. (Make:- Epcos/ Usha/ Keltron.)
66Supply only Running capacitor 50+6 MFD. (Make:- Epcos/ Usha/ Keltron.)
67Supply only Starting capacitor 80-100 MFD. (Make:- Epcos/ Usha/ Keltron.)
68Supply only Starting capacitor 100-120 MFD. (Make:- Epcos/ Usha/ Keltron.)
69Supply only Starting Relay 1622. (Make:- Hytech/ Renutrol/ Sri Ram/Microtech.)
70Supply only Starting Relay 2000. (Make:- Hytech/ Renutrol/ Sri Ram/Microtech.)
71Supply only Overload Relay. (Make:- Hytech/ Renutrol/ Sri Ram/Microtech.)
72Supply only Thermostat switch 2059/2064/2054. (Make :- Indfos/ Renutrol).
73Supply only Condenser fan blade for Window type A.C of Capacity 1.5/2 TR made of Plastic.
74Supply only Condenser fan blade for spilt Type A.C of Capacity 1.5/2 TR made of Plastic.
75Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for split AC of capacity 1.5/2 TR as directed by Engr-in-Charge.
76Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for window AC of capacity 1.5/2 TR as directed by Engr-in-Charge. Note for item No 78 to 90:- Materials of item Nos 78 to 90 to be incorporated in item Nos 76 & 77 here-in-before.
77Supply & fixing in repairs plastic louvers (Front panel)for Window AC 1.5/2 TR complete all as directed by Engr-in-Charge.
78Supply & fixing in repairs of capillary tube for Split/ Windowtype AC of capacity 1.5/2 TR complete all as directed by Engr-in-Charge. (Make:- As per Sample)
79Supply & fixing in repairs of capillary filter for Split/ Windowtype AC of capacity 1.5/2 TR complete all as directed by Engr-in-Charge. (Make:- As per Sample)
80Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the Split/window type Air Conditioner of Cap1.5/2 Ton,of any make any type from any location as directed and specifed.
81Supply , Installingand testing of new sealed unit compressorfor window type Air Conditioner ofCapacity 2 TR with necessary modification capillary tube etc&Charging of Gas R-22/R-410a/R-32 and commissioning complete all as specified & directed by Engg-in-Charge. (Make:- Emerson /Tecumseh/ LG) Note :-1. Gas charging shall be paid spepartely under relevent item. 2. Transportation Charges from siteto trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above.
82ditto- all as per item No. 81 abovebut window type Air Conditioner ofCapacity1.5 TR. (Make:- Emerson /Tecumseh/ LG)
83ditto- all as per item No. 81 abovebut spilt type Air Conditioner ofCapacity 2 TR. (Make:- Emerson /Tecumseh/ LG)
84ditto- all as per item No. 81 abovebut spilt type Air Conditioner ofCapacity 1.5 TR. (Make:- Emerson /Tecumseh/ LG)
85Supply & fixing in Replacementof Indoor Air blower motor for Split 1.5 TR & 2 TR capacity complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.)
86Supply & fixing in replacement of copper wounded condenser fan motor for Split type AC of 1.5 TR & 2 TR capacity outdoor units complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.)
87Disconnecting the mains and taking out the unserviceable condenser coilof window type AC of capacity 1.5/ 2TR of any make from any location and supply, fixing and testing new condenser coil as per existing size & patterns for complete all as specified & as directed. (Make:- Voltas/Carrier/LG)
88ditto- all as per item No. 87 above but spilt type Air Conditioner Capacity 1.5/ 2 TR. (Make:- Voltas/Carrier/LG)
89Supply & fixing in repairs of evaporator/cooling coil for window type Air Conditioner of capacity 1.5/ 2TRof existing make and size complete all as specified & as directed by Engr-in-Charge. (Make:- As per Sample)
90ditto- all as per item No. 89 above but spilt type Air Conditioner Capacity 1.5/ 2 TR. (Make:- As per Sample)
91Supply and fixing in repairs of1.5TR capacity split type Air Conditioner outdoor kit including condenser coil, blower motor, chasis, base plate complete set except compressor complete all as specified & as directed by Engr-in-Charge. (Make:- Nepoleon/ Commander/ Camipro/ Skoda.)
92ditto- all as per item No. 91 above but spilt type Air Conditioner of capacity2 TR. (Make:- Nepoleon/ Commander/ Camipro/ Skoda.)
93Taking down unserviceable indoor unitof split type AC of any make andsupply & fixing new indoor unit complete set suitable for 1.5 TRcapacity complete all as directed by Engr-in-Charge. (Make:- LG/Carrier/Voltas.)
94ditto- all as per item No. 93 above but spilt type Air Conditioner of capacity2 TR. (Make:- LG/Carrier/Voltas.)
95Supply and fixing in repairs of 2 TR capacity window type AC kit including condenser coil, cooling coil, front grill blower motor, chasis, base plate complete set except compressor. (Make:- Nepoleon/ Commander/ Speed.)
96Supply and fixing in repairs of 1.5 TR capacity window type AC kit including condenser coil, cooling coil, front grill blower motor, chasis, base plate complete set except compressor. (Make:- Nepoleon/ Commander/ Speed.)
97Supply and fixing in replacement Honeycomb based cooler pad for air washer of 50mm thickness size complete all as specified and directed.
98Taking down carefully existing surface/concealed unserviceable copper/Aluminium point wiring(light, fan socket or power) complete with fittings such as switches, ceiling rose, lamp holder, regulators, sockets, F/Tube/Sketch light fittings, wooden terminal box, plastic laminated sheet cover, from Teak Wood batten including TeakWood batten or PVC conduitscomplete all as specified & as directed.
99Material and labour for point wiring using 1.50 sqmm size FRLS, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) for wall and 25mm PVC medium grading grade casing and caping in the ceiling wherever required with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.2 mm thick pressed steel terminal box for mounting fittings and covered with 3 mm thick white bakelite / laminated hard glossy surface sheet top cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size FRLS stranded copper conductor cable as in earth wire and connecting all metal parts to common earth dolly for one light / Fan / exhaust fan / Bell point controlled by one, one way switch complete all as specified & directed by Engr-in-Charge. (Make of cable:-NICCO / FINOLEX / RR KABEL/ HAVELL"S/ POLYCAB / KEI INDUSTRIES LTD) (Make of Conduit:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST)
100All as per item No. 99.00 above but for one 5 pin 5/6 Ampere socket outlet point controlled by one, one way switch on the same board complete all as specified and directed by Engr-in-Charge.
101All as per item No.99.00 above but for one 5 pin 5/6 Ampere socket outlet point controlled by one, one way switch on independant board complete all as specified and directed by Engr-in-Charge.
102Material and labour for point wiring for one 15/16 Ampere socket outlet independent point using 2.50 sqmm FRLS size (Nominal cross sectional area), PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade concealed (not less than 25 mm dia) for wall and 25mm PVC medium grading grade casing and caping in the ceiling wherever required with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.2 mm thick pressed steel terminal box for mounting fittings and covered with 3 mm thick white bakelite / laminated hard glossy surface sheet top cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 2.50 sqmm FRLS size stranded copper conductor cable as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed. (Make of cable:-NICCO / FINOLEX / RR KABEL/ HAVELL"S/ POLYCAB / KEI INDUSTRIES LTD Make of Conduit:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST)
103Supply & fixing in repair socket out let 2 in 1, 3/5 Pin, 15/16 Ampere, 230V AC, flush type complete all as specified and as directed. (Make : Anchor / Cona / Kinjal /Havells)
104Supply & fixing in repair ceiling rose, 3 phase, PVC / polycarbonate, surface type, 65mm x 50mm, insulated body, three terminals complete all as specified and as directed. (Make : Anchor / Ess Ess Kay / Havells/ Cona)
105Supply & fixing in repair modular switch one module, 15/16 Amp, one way, 230 volts AC complete all as specified and as directed by Engr-in-Charge. (Make : Anchor / Cona / Crabtree / Legrand / Indo Asian (Glint))
106Supply & fixing in repair of modular socket outlet (two module) 5/6 amps, 2 in 1, 2 & 3 pin combined, 230 volts AC complete all as specified and as directed by Engr-in-Charge. (Make : Anchor / Cona / Crabtree / Legrand/ Indo Asian (Glint) )
107Supply & fixing in repair modular socket out let (two module), 2 in 1, 3 Pin suitable for 5/6 Amp and 3 Pin suitable 15/16 Amp combined, 230 volts AC complete all as specified and as directed by Engr-in-Charge. (Make : Anchor / Crabtree / Legrand / Indo Asian (Glint)
108Supply & fixing in repair of electric ding dong bell, 230 volt AC, single pole, complete all as specified and as directed by Engineer-in-Charge. (Make :- Anchor / Cona / Wipro / Bajaj/Havells)
109Supply & fixing in repair of flush type bell push, 5 Amps complete all as specified and as directed by Engr-in-Charge. (Make : Anchor / Cona /Kinjal / Havells)
110Supply & fixing in repair of lamp holder, PVC/polycarbonate type, insulated body with back plate of batten fitting complete all as specified and as directed. (Make : Anchor / Ess Ess Kay / Plaza / Havells)
111Supply & fixing in repair of stepped type 5 steps 100 watts electronic fan regulator flush type on the existing phenolic laminated sheets etc as required all as specified and as directed. (Make : Anchor / Havells / Usha / Crompton / Bajaj)
112Supply & fixing in repair of Modular Fan regulator step type, 1 Module size complete all as secified and as directed. (Make: Havells / Legrand/ Crabtree/ Anchor)
113Disconnecting from mains/taking out existing unserviceable/defective Servo Voltage of capacity 10 KVA of any size, type, and make removing from foundationand shifting from ground floor to II/III floor of building complete all as specified and as directed.
114Material and labour forpainting outside body with synthetic enamel paint of existing tint/colour of 10 KVA voltage stablizer complete all as specified and as directed.
115Material and labour for on line Dehydration/filteration of Servo Voltage Stablizer oil including filteration using automatic centrifuging machine minimum three cycles to achieve dielectric strength 40 to 60 KV breaking capacity at 2.5mm gap by absorbing and abolishing all sludge particles as per BS-66-1963 including topping up with new transformer oil as required complete all as specified and as directed. Note- (i)Centrifuging Machine with all T&P & testing machine of oil required for dehydration shall be arrange by contractor. (ii) Oil required for topping up the stablizer will be measured & paid separately as supply only under respective item of this Sch.
116Supplying and filling/topping up transformer oil low viscocity, dielectric strength 35 to 40 KV breaking voltage for topping up servo voltage stablizers duly centrifuging including filter action by using automatic centrifuging machine to achieve min 35 to 40 KV breaking capacity at 4 mm gap by absorbing and abolishing all sludge particles for use as per BS-B-66-1983 complete all as specified and as directed..
117Supply, installation, testing and commissioningin replacement complete indoor unitfor tower type split AC of 4 TR, inclusive ofblower motor, blower, PCB circuit ,wiring kit with cooling coil etc,suitable for R-410A/R-32 Gas, including all copper tubing of required size & electrical cabling up to 5 metre all as required as per site complete all as specified and directed.Make: Lloyd /Carrier/ Blue star/Voltas/Hitachi. Indoor Unit Technical specification- Nominal cooling cap -3.5 TR, Indoor fan motor-300 watt, Dimension(WXDXH): 55 cm X 35 cm X 180 cm. Gross weight: 60-70 KG, Operating temp.- >17 °C, Controller-Remote Control, IDU Noise (dB)-52 dB, Air Flow (m³/h)-1680 m³/h, Input Power (W)-5490 W, Cooling Capacity (W)13500 W. Note :- Old taking down indoor unit of any capacity and size shall be deposited to MES store yard from existing location. The rate include necessary transportation & Manpower to dismantling and transporting of the unit.
118Supply, installation, testing and commissioningin replacement complete outdoor unit for Tower type split AC of 4 ton, without scroll compressor, suitable for R-410A/ R-32 Gas,condenser coil, wiring kit , condenser fan motor, condenser fan, terminal etc also making platform for outdoor unit with suitable size of fastener and MS frame work stand and making good the disturb surface including all copper tubing of required size, control wiring all as required as per site complete all as specified and directed. Make:Model No- GLT48B01AG of Lloyd or equivalent model ofCarrier/ Blue star/Voltas/Hitachi. Outdoor Unit Technical specification- Power Supply- 3 phase, 380-415 Volt, 50 Hz, Outdoor fan motor-290 watt, Fan motor speed-830 RPM, Dimensions(WXDXH): 94.6 cm x 41.0 cm x 81.0 cm, Gross weight - 75-93 KG, Refrigerant piping-Max pipe lenght-20 mtr, Max difference in level-10 mtr Note :- The outdoor unit shall be replaced from roof of building of height 40-50ft. Note :- Old taking down Outdoor unit of any capacity and size shall be deposited to MES store yard from existing location. The rate include necessary transportation & Manpower to dismantling and transporting of the unit.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail