Repairs/Maintenance To Compound Wall, Sewage System Etc., Repairs To Summer Cooling Appliances,External Water Supply Pipeline At 7N Det And Ramnad Under Ge Tirunelveli, Ramanathapuram-Tamil Nadu

Military Engineer Services-MES has published Repairs/Maintenance To Compound Wall, Sewage System Etc., Repairs To Summer Cooling Appliances,External Water Supply Pipeline At 7N Det And Ramnad Under Ge Tirunelveli. Submission Date for this Tender is 19-01-2023. Air Conditioner Tenders in Ramanathapuram Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

35516822
Repairs/Maintenance To Compound Wall, Sewage System Etc., Repairs To Summer Cooling Appliances,External Water Supply Pipeline At 7N Det And Ramnad Under Ge Tirunelveli
Open Tender
Indian
Tamil Nadu
Ramanathapuram
19-01-2023

Tender Details

Repairs / Maintenance To Compound Wall, Sewage System Etc., Repairs To Summer Cooling Appliances, External Water Supply Pipeline At 7N Det And Ramnad Under Ge Tirunelveli

Key Value

Document Fees
INR 500 /-
EMD
INR 75000.0 /-
Tender Value
INR 37.50 Lakhs /-

BOQ Items

Name of Work:REPAIRS/MAINTENANCE TO COMPOUND WALL, SEWAGE SYSTEM ETC., REPAIRS TO SUMMER COOLING APPLIANCES,EXTERNAL WATER SUPPLY PIPELINE AT 7N DET AND RAMNAD UNDER GE TIRUNELVELI (TENDER ID:2022_MES_572029 _1)
Sl. No. Item Description
1CIVIL WORKS
2Checking and attending to sewage line / manhole/septic tank blockage / leakage by cleaning of drains of dia not exceeding 150 mm including blocked manholes / Nahani traps/gully traps/was by rodding from manholes and well flushing after cleaning and removal of blocked/decomposed sludge/dirt and other material not exc 50 m and burning the same including removing and re fixing manhole covers without damaging complete by attending as a job. Note: Attending 5 complaints shall be measured as a job..
3Cleaning of septic tank bailing out fluid, decomposed materials sludge etc, scrapping and washing the wall with fresh water and disposal of decomposed materials, sludge etc out side MD land completed all as directed by Engr-in-charge for the following septic tanks :-
4(a) 100 users septic tank
5(b) 50 user septic tank
6(c) 25 User septic tank
7(d) 10 Users septic tank
8Excavation in trenches, not exceeding 1.5m wide, and not exceeding 1.5m in depth for foundation etc and getting out in hard / dense soil all as specified
9Returning filling in trenches including spreading levelling watering and well ramming in layers not exc 25cms in soil as specified and directed Engr-in-Charge
10Removing excavated material/soil to a distance not exc 250 mtr but n exc 500 m away and deposing where as directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engr-in-charge
11Demolition and breaking up SWG drain pipe of 150mm dia set in cement concrete as in trenches as directed by Engr-in-charge Note: Excavation and RFR will measured and paid separately.
12M&L for Plain cement concrete 1:3:6 type C2 (using 40mm graded granite stone aggregate) as in concrete bed to drain pipes for 150 mm dia including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
13M&L 150 mm dia HDPE Pipes PN 10 including laying in trenches with all necessary fittings as specified and as directed by Engr-in-Charge
14Demolition of brick work built in cement mortar or lime mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and pre cast concrete articles all as specified and as directed.
15M&L for brick work with sub class "B" bricks old size straight or curved on plan exc 6m mean radius built in CM (1:4) all as specified.
16M&L rendering 15mm thick plastering on fair faces of concrete surface in CM 1:4 with water proofing compound @ 2% by weight of cement even and fair surface complete all as specified and directed. Note:- Water proofing compound shall be measured and paid separately.
17Supply only integral water proofing compound complete all as specified and directed.
18Demolition ofPlain cement Concrete of any description and in any position not otherwise specifically provided for all as specified and as directed.
19M&L for Plain cement concrete 1:3:6 type C2 (using 40mm graded granite stone aggregate)in foundation, filling and mass concrete complete all as specified and directed.
20M&L Plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in benching to manholes, coping etc.. including necessary formworks complete all as specified and directed.
21Material and labour for Forming fair finish drain or channel 30cm inner girth in cement concrete using extra cement complete all as specified and as directed.
22Demolition of cement concrete reinforced cover slabs of man holes etc n.exc 15 cm thick all as specified & directed.
23M&L for Precast cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in manhole/ gully trap cover slab set in cement mortar 1:4 including necessary form work all as specified and directed.
24M&L for TMT bars 10mm and over cut to length, bend to shape required incl cranking, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and as directed
25Taking down cement plaster on brick or stone walls etc including all quoins,arches,pillars, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
26M&L for rendering 10mm thick in cement mortar 1:6on fair faces of brick work or concrete surfacescomplete all as specified and as directed.
27M&L for preparation of new plastered wall surface and applying two coat of cement base paint over a coat of primer complete all as specified.
28M&L for preparation of old plastered wall surface and applying one coat of cement base paint complete all as specified.
29M&L for preparing Old steel surfaces over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified.
30Demolition ofPlain cement Concrete of any description and in any position n exe 15cm thk (below or above GL) all as specified and as directed.
31M&L for 100 mm thick PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in floor, laid in panel, surface finished fair and even without using extra cement including necessary formwork complete all as specified and as directed.
32M&L Forming Contraction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound grade "A" all as specified and as directed.
33REPAIRS TO COOLING APPLIANCES
34Providing comprehensive annual maintenance periodical/preventive maintenanceincluding annual maintenance of cooling appliances ( Split type Air Conditioners, Water coolers, Refrigerators and Deep Freezers) as per manufacturer specificationby providing one AC/Refrigeration mechanic including replacement ofcomponents as listed in subsequent items here in after. The maintenance of cooling appliances includes the following:- (a) Cleaning of coil unit with dust blower, lubricate the indoor and outdoor fan motor with oil. (b) Cleaning of air filters, indoor unit grills & filters through air blower. (c) Checking and cleaning the drain connection and air filter periodically, washing of coil with ventiklean solution once in a contract period. (d) Check and replace the refrigerant pipe once in a contract period or as and when required. (e) Check and repair the minor electrical fault in incoming supply. (f) Check and replace the water PVC pipe. (g)Replacementof faulty spares/components (h) Carry out the monthly, quarterly and annual maintenance of all cooling appliances of any make & capacity with job card and making the Cooling Appliances functional (Each Job contains 3 Complaints)
35Supply only the following new items for 1.5 / 2.00 Ton CapacitySplit type AC including testing and commissioning etc complete all as directed.
36Capacitor60 MFD.
37Air filters.
38Condenser fan motor 1.5 HP with blade set .
39Blower fan motor 1.6 HP with blade set. Make:
40Blower with circular leaf.
41Copper condenser coil unit (for A/C)
42Copper cooling coil unit (for A/C)
43Indoor motor capacitor 2.5 MFD. Make:
44Stainer tube (copper)
45Capillary tube (copper)
46Non return valve (For gas top up charging)
47Remote control suitable for Non inverter model Split AC. Make :LG
48Remote control suitable for Non inverter model Split AC. Make :Bluestar
49Remote control suitable for Non inverter model Split AC. Make :Daiken
50Remote control suitable for Non inverter model Split AC. Make : Universal
51Remote control suitable forinverter model Split AC. Make :Bluestar
52Remote control suitable for inverter model Split AC. Make :Daiken
53PCB board suitable for indoor unit of Non inverter model split AC 1.5/2.0 TR Make :LG
54PCB board suitable for indoor unit of Non inverter model split AC 1.5/2.0 TR Make :Bluestar
55PCB board suitable for indoor unit of Non inverter model split AC 1.5/2.0 TR Make :Daiken
56PCB board suitable for indoor unit of Inverter model split AC 1.5/2.0 TR . Make :LG
57PCB board suitable for outdoor unit of Inverter model split AC 1.5/2.0 TR . Make :LG
58PCB board suitable for indoor unit of Inverter model split AC 1.5/2.0 TR . Make :Daiken
59PCB board suitable for outdoor unit of Inverter model split AC 1.5/2.0 TR . Make :Daiken
60Copper pipe of size 1/2" for suction line with foam insulation
61Copper pipe of size 1/4" for discharge line with foam insulation
62Swing Motor for indoor unit
63Outdoor unit stand
64Condenser fan motor blade
65Indoor Motor blower
66Supply and fixPVC insulated unsheathed cables of size 2.5 sqmm 3 core multi-stranded Copper conductor wire suitable for geysers complete all as specified and as directed.
67Supply and fixMetal plug top for ACcomplete all as specified and as directed.
68Supply only the new following items for3.00 Ton Capacity Floor standing /Voltas make Tower AC including testing and commissioning etc complete all as directed.
69Air filters.
70Condenser fan motor with blade set .
71Blower fan motorwith blade set.
72Blower with circular leaf.
73Condenser coil unit (for A/C)
74Cooling coil unit (for A/C)
75Indoor motor capacitor 2.5 MFD.
76Strainer tube (copper)
77Capillary tube (copper)
78Non return valve (For gas top up charging)
79Remote control suitable for Non inverter Tower AC.
80PCB board suitable for outdoor unit.
81PCB board suitable for indoor unit.
82Copper pipe of size 5/8" for suction line with foam insulation
83Copper pipe of size 3/8" for discharge line with foam insulation
84Swing Motor for indoor unit
85Outdoor unit stand
86Condenser fan motor blade
87Indoor Motor blower
88Supply and fixPVC insulated unsheathed cables of size 4 sqmm 5 core multi-stranded Copper conductor wire suitable for geysers complete all as specified and as directed.
89Three phase metal plug top
90Supply only the new following items for water cooler 40/80 Litres capacityincluding testing and commissioning etc complete all as directed.
91Relay unit
92PVC float valves , high pressure with polythene float and fly nut screwed to iron pipe or ferrule of bore 15 mm.
93Thermostatassembly
94Water tap suitable for water cooler.
95Starting Capacitor 80-100 MFD
96Running capacitor 36 MFD
97Condenser fan motor 1.6HP with blade set
98Over load protector (OLP)
99Supply only new compressor including pumping out oil, cleaning the refrigeration system with CO2 and charging refrigerant gas (M-22/F-22) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning all as directed for the following appliances :-
100Split type AC 1.5 Ton capacity. Make: Bluestar or Voltas /LG/Samsung/Panasonic
101Split type AC 2.0 Ton capacity.Make: Bluestar or Voltas /LG/Samsung/Panasonic
102Water cooler 40/80 Litres capacity . Make: Samsung or Voltas /LG/Bluestar
103Floor standing/Tower AC3 Ton Capacity. Make : Voltas or LG/Bluestar/Samsung
104Repair to stabilizer of capacity 4 or 5 KVA capacity by removing the old / burnt transformer and replaced with new transformer complete all as directed.
105Repair to stabilizer by removing the old / burnt relay board suitable for Voltage stabilizer of capacity 4 KVA / 5 KVA capacity
106M & L Painting complete with super enamel paint of approved colour for water coolerall as specified and directed.
107Supply and fix condensed water PVC flexible pipe of standard quality of suitable size fixing with suitable clamps on wall for split type AC of capacity of 1.5/2.0 Ton complete all as specified and as directed.
108Supply only R22 /R32 /R410 Gas complete all as specified and directed.
109Supply only R134a Gas complete all as specified and directed.
110Dismantling and disconnecting carefully the existing split AC 1.5/2.0 Ton capacity after disconnecting the copper pipe and electrical connection, Cleaning the refrigeration system with CO2 and fixing in a new position including, brazing, testing and commissioning complete all as directed for the following cooling appliances :- NOTE : The wt of refrigerant used for filling/top up shall be measured and paid under respective item.
111Supply only 2 nos of1/2" x 3/8" Foam Heat Insulated Pipe Black for Air Conditioner complete all as specified and directed.
112Material and labour for making good of surface withsealing the cavity /hole drilled to facilitate tubing, using white cement/POP and cleaning the surface to match with existing surface complete all as specified and directed.
113Material only for following items for refrigerators/Deep Freezers 320 Litres capacity including testing and commissioning etc complete all as specified and directed.
114(a) Relay unit.
115(b) Thermostat assembly.
116(c)Condenser coil
117(d) Freezer for double door refrigerator
118Supply only new compressor including pumping out oil, cleaning the refrigeration system with CO2 and charging refrigerant gasproviding NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning all as directed for the following appliances :-
119(a) Refrigerators 310/320 litres capacity.Make: Samsung or Voltas /LG/Bluestar
120(b) Deep Freezers 320 litres capacity.Make: Samsung or Voltas /LG/Bluestar
121M & L Painting complete with super enamel paint of approved colour for Refrigerator/ water coolerall as specified and directed.
122REPAIRS TO WATER SUPPLY
123Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for laying pipe or excavation in pits not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in any type of soil, complete all as specified
124Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type ofsoil, complete all as specified
125Removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
126Taking down bore steel tubing and connections, removal from site for taking into creditcomplete all as specified and as directed by the Engineer-in-Charge of following bore sizes:-
127(a) 20 mm bore steel tubing
128(b) 25 mm to 32 mm bore steel tubing
129(c) 40 mm to 50 mm bore steel tubing
130(d) 80 mm bore steel tubing
131Supply and fixGI tubingmedium gradeincluding provision of necessary fittings like Tee,Bend,Socket,Elbow, Short pieces connectors, plugs, unions, etc and accessories laid in trenchesall as specified and directed by Engineer-in-Charge of following bore sizes:-
132(a) 20 mm bore steel tubing
133(b) 25 mm bore steel tubing
134(d) 40 mm bore steel tubing
135(e) 50 mm bore steel tubing
136(f) 80 mm bore steel tubing
137Supply and FixingGI tubingmedium grade including provision of fittings like Tee,Bend,Socket,Elbow, Short pieces connectors, plugs, unions, etc and accessories on walls/roofs all as specified and directed by Engineer-in-Charge of following bore sizes:-
138(a) 20 mm bore steel tubing
139(b) 25 mmbore steel tubing
140(d) 40 mm bore steel tubing
141(e) 50 mm bore steel tubing
142M & L for cutting and screwing (or lengthening screw on pipe to form connector) in the existingbore steel tubingfor alterations or additions (Each cut measured) after taking down existing steel tubing complete all as specified and as directed by the Engineer-in-Charge of following bore sizes:-
143(a) 20 mm bore steel tubing
144(b) 25 to 32 mm bore steel tubing
145(c) 40 mm to 50 mm bore steel tubing
146M & L for cutting and screwing (or lengthening screw on pipe to form connector)done in position without taking down in the existingsteel tubing for alterations or additions (Each cut measured) complete all as specified and as directed by the Engineer-in-Charge of following bore sizes:-
147(a) 20mm bore steel tubing
148(b) 25 to 32 mm bore steel tubing
149(c) 40 mm to 50 mm bore steel tubing
150S & F of gun metal gate valve, painted finish, with forged brass spindle and iron wheel head, screwed both ends internally IS-778 marked, Class-2,for iron pipe of following sizes complete all as specified and directed.
151(a) 20 mm bore steel tubing
152(b) 25 mmbore steel tubing
153(c) 32 mmbore steel tubing
154(d) 40 mm bore steel tubing
155(e) 50 mm bore steel tubing
156Supply and fix in repairbrass float valve, ISI marked high pressure with polythene float and fly nut complete, screwed of following size / bore including necessary GI fittings such as elbow, reducer, nipple etc.
157(a) 20 mm dia
158(b) 25 mm dia
159(d) 40 mm dia
160(e) 50 mm dia
161Supply and fix Pressure gauge 5" dia, 0 to 14 Kg/cm2 range fixing on delivery pipe of pump set and removing existing defective pressure gauge and taken as credit complete all as specified and as directed.
162Supply and fixsluice valves flanged end, cast iron body, flanged and drilled and non rising type stainless steel spindlewith nut, long body, class P N 1.6, conforming to IS 14846 of 2000 for following sizesincluding all flange joint with rubber or fiber board, bolts, nuts and washers complete including pumping out accumulated water all as specified and directed by Eng-in-Charge of following sizes.
163(a) Sluice Valve, Class PN 1.6, 63mm dia
164(b) Sluice Valve, Class PN 1.6, 80mm dia
165(c) Non Return Sluice Valve, 80mm dia
166Supply and fixFoot Valve screwed / flanged including necessary fittings like connectingflanges of following sizes.
167(a) Foot Valve 50 mm dia
168(b) Foot Valve63 mm dia
169Replacement of GI flange having holes(ISI marked) suitable for 40mm bore pipe including joinery material such as rubber gasket bolt units and washers etc in place of unserviceable all as directed.
170All as per item No.65 above but Suitable for 50 mm bore pipe
171All as per item No. 65 above but Suitable for 80 mm bore pipe
172Replacement of GI union of both end lock nut screwed with leak proof washer connected to existing GI tubing of 20mm bore in place of unserviceable complete all as directed (ISI marked)
173All as per item No. 66herein before but suitable for 25 mm bore pipe
174All as per item No. 66 herein before but suitable for 40 mm bore pipe
175All as per item No. 66herein before but suitable for 50 mm bore pipe
176Material and labour forby scraping / cleaning with wire brushes to remove the old painting from pump, motor, coupling guard, MS common base frame and painting with two coats of synthetic enamel paint of approved quality over a coat of red oxide primer as specified below here in after for 1 / 2 / 3 & 5 HP pumping sets:-(a)Motor and pump - Smoke Grey colour (b) Coupling guard and motor air grill - Post office Red colour.(c)Common base frame - Black colour (d)Suction line and delivery line in side pump house - Navy blue colour for fresh water pipe lines. (e) Writing SM/MES No 25 mm wide in white colour on motor and pump.
177M & L for earthing complete with galvanised steel earth plate electrode60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 32x6mm GI strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 in SSR part1 connected to earthing test point, including 20 mm GI pipe (Medium grade) for watering and 40 mm GI pipe (Medium grade) for protection of earth strip andetc..including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wire mesh ,funnel, lugs and charcoal, salt etc all as applicablecomplete all as specified and as directed by the Engineer-in-Charge
178M & L for earthing complete with galvanised steel earth plate electrode60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3in SSR part 1 connected to earthing test point, including 20 mm GI pipe (Medium grade) for watering and 40 mm GI pipe (Medium grade) for protection of earth strip andetc..including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wire mesh ,funnel, lugs and charcoal, salt etc all as applicablecomplete all as specified and as directed by the Engineer-in-Charge
179Taking down defective mono block / Centrifugal pump setfrom foundation by opening of coupling and foundation bolts and transporting to workshop for repairing and reassembling after servicing and overhauling complete with oiling/greasing, lubricating the parts including repair / replacement of worn out parts and replacement of base foundation nuts and bolts and re-installing ,necessary electrical connection and testing for satisfactory performance complete all as specified and directed by Engineer - in - Charge.for electric driven pump set of 1 HP/ 2 HP capacity Note:- (i) The rate quoted for this item shall includes labour charge only for maint repair and replacement of defective/UNSV spares/accessories. Spares are to measured and paid separately under subsequent items. (ii) Cost of other minor items/spares such as nut, bolts washers, gaskets,etc which are not covered under Sch "A" but required for effective functioning of the plant shall be deemed to included in this item. (ii) The cost of spares shall be paid under relevant items given below (iii)In case of any damage to thepipes during the time of removal of the pump set ,contractor shall be responsible for repairing the same without any extra cost to the government.
180Rewinding of motorcoil complete as per IS-396 of 1953 using super enameled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional.(Note: Supply only items required for repair shall be meausred and paid under relevant items herein after)
181Supply onlyBall bearings (drive and non drive end)
182Supply onlyElectro dynamically balanced bronze impeller
183Supply onlyImpeller Key
184Supply onlyWater Seal
185Supply only Terminal connection with terminal box
186Supply only Condenser suitable capacity / MFD
187All as per item No :70 herein before but pump set of capacity 2 HP/ 3 HP Note: The cost of spares shall be paid under relevant items given below as" Supply only".
188Rewinding of motorcoil complete as per IS-396 of 1953 using super enameled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional.
189Supply only Ball bearing (Drive and Non drive end)
190Supply only Cooling fan blade
191Supply only Cooling fan cover with suitable screws
192Supply only Terminal box with terminal connection
193Supply only Electric dynamically balanced bronze impeller
194Supply only Shaft mild steel
195Supply only Gun Metal bush
196Supply only Gland cup with bolts and nuts
197Supply only Flange drilled suitable size with bolts, nuts and washersincluding rubber gasket
198Supply only Air cock nozzle brass
199Supply only Shaft coupling
200Supply only Thrust bearing
201Supply only Rotor sleeve
202Supply and fix Three phase direct online starter, suitable for 1 HP - 5 HP Pump/motor including necessary electrical connections and taking down old unserviceable all as directed.Make : L & Tor equivalent
203Supply and fix single phase preventer 3 phase 415 voltsincluding taking out old unserviceable all as directed..Make: L & T or equivalent.
204Taking down defective mono block / Centrifugal pump setfrom foundation by opening of coupling and foundation bolts and transporting to workshop for repairing and reassembling after servicing and overhauling complete with oiling/greasing, lubricating the parts including repair / replacement of worn out parts and replacement of base foundation nuts and bolts and re-installing ,necessary electrical connection and testing for satisfactory performance complete all as specified and directed by Engineer - in - Charge.for electric driven pump set of 0.5 HP/1 HP capacity Note:- (i) The rate quoted for this item shall includes labour charge only for maint repair and replacement of defective/UNSV spares/accessories. Spares are to measured and paid separately under subsequent items. (ii) Cost of other minor items/spares such as nut, bolts washers, gaskets,etc which are not covered under Sch "A" but required for effective functioning of the plant shall be deemed to included in this item. (ii) The cost of spares shall be paid under relevant items given below (iii)In case of any damage to thepipes during the time of removal of the pump set ,contractor shall be responsible for repairing the same without any extra cost to the government.
205Rewinding of motorcoil complete as per IS-396 of 1953 using super enameled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional.
206Supply onlyBall bearings (drive and non drive end)
207Supply onlyElectro dynamically balanced bronze impeller
208Supply onlyImpeller Key
209Supply onlyWater Seal
210Supply only Terminal connection with terminal box
211Supply only Condenser suitable capacity / MFD
212Supply only Gun Metal bush
213Supply only Gland Cup with bolts and nuts
214Supply only GI Flange drilled suitable size bolts, nuts, washers and rubber gasket
215Supply only Shaft Mild steel
216Supply only Rotor sleeve
217All as per item No 74 herein before but pump set of capacity 5 HPNote: The cost of spares shall be paid under relevant items given below as " Supply only".
218Rewinding of motorcoil complete as per IS-396 of 1953 using super enameled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional.
219Supply only Ball bearing (Drive and Non drive end)
220Supply only Cooling fan blade
221Supply only Cooling fan cover with suitable screws
222Supply onlyTerminal box with terminal connection
223Supply only Electric dynamically balanced bronze impeller
224Supply only Shaft mild steel
225Supply only Gun Metal bush
226Supply onlyGland cup with bolts and nuts
227Supply only Flange drilled suitable size with bolts, nuts and washers including rubber gasket
228Supply only Air cock nozzle brass
229Supply only Shaft coupling
230All as per Slitem No :75 herein before but pump set capacity 5 HP . Note: The cost of spares shall be paid under relevant items given below as " Supply only".
231Rewinding of motorcoil complete as per IS-396 of 1953 using super enameled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional.
232Supply only Thrust bearing
233Supply only Electro dynamically balanced bronze impeller
234Supply only Gun Metal bush
235Supply only Gland Cup with bolts and nuts
236Supply only GI Flange drilled suitable size bolts, nuts, washers and rubber gasket
237Supply only Shaft Mild steel
238Supply only Rotor sleeve
239All as per Slitem No :76 herein before but Non- clogging submersible pump set capacity 7.5 HP . Note: The cost of spares shall be paid under relevant items given below as " Supply only".
240Rewinding of motorcoil complete as per IS-396 of 1953 using super enameled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional.
241Supply only Thrust/ball bearing
242Supply only Electro dynamically balanced bronze impeller
243Supply only Cooling fan blade
244Supply only terminal box with terminal connectors
245Supply only Shaft Mild steel
246Supply only Gun Metal bush
247Supply only chlorine test kit. Make: Aqua/Highbird/RMCO
248Supply only O-tolidine regent solution in 500 ml bottle(Make : Glaxo/SDS/Water Chem)
249Supply only Calcium Hypochlorite 65% to 70% Chlorine content in granular form (Calcium based Granular disinfectant for water treatmentof drinking water ). Packed in 45 Kgs each Drum. Make:- Sree Rayalaseema Hi Strength Hypo Ltd.(Brand :- PURI CHLOR)or approved by NMPT Committee of E-in-C"s Branch.Note:- The contractormust submit the NSF Certificate of the product, FSSAI Registration and COC (Certificate of Compliance) in original from manufactures by All India Authorized MES Distributor for each batch of product delivered indicating. Including chemical analysis report by all India authorized MES Distributor. Product must have min. 65% Chlorine Contents suitable for Human Consumption.
250Replacement of Fabricated MS angle iron/channel of any section and foundation bolts, nuts and washer made ofMSof suitable sizes including painting for motor/pump bed foundation including cement work with PCC in grouting etc complete all as directed.
251Material and Labour Cleaning valve chamber of any size by removing all unwanted particles such as mud, sand, dust, dirt, decayed leaves etc. and applying two coats of white wash to all internal and external surfaces of valve chamber all as directed by Engineer-in-charge.
252Cleaning the internal and external surface of UG sump / Static water tankof capacity up to 10000 gallons and well by scrapping/brushing and removing all silt dust etc from walls, floors, clean with water and bleaching powder and applying one coat of lime wash to all internal surfaces and complete removal of sand,dust.dirt and other unwanted coatings from the exterior wall surfaces by suitable means and painting with weather proof oil bound distemper to complete side wall and top surface of sump including writing particulars such as capacity of sump, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting to incoming and outgoing pipe lines and valves/valve chambers with approved colour (Pipe line exposed above surface) of any size complete all as directed
253Cleaning the internal and external surface of Shallow well of size 4.50 mtr dia. and 6 mtr depth by scrapping/brushing and removing all silt dust etc from walls, floors, clean with water and bleaching powder and applying one coat of lime wash to all internal surfaces and complete removal of sand,dust.dirt and other unwanted coatings from the exterior wall surfaces by suitable means and painting with weather proof oil bound distemper to complete side wall of shallow well including writing particulars such as depth of shallow well, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting topipe lines and valves with approved colour (Pipe line exposed above surface) of any size complete all as directed
254Cleaning the internal and external surface of deep Open well of size 7-10 mtr dia. and 10-15 mtr depth by scrapping/brushing and removing all silt dust etc from walls, floors, clean with water and bleaching powder and applying one coat of lime wash to all internal surfaces and complete removal of sand,dust.dirt and other unwanted coatings from the exterior wall surfaces by suitable means and painting with weather proof oil bound distemper to complete side wall of shallow well including writing particulars such as depth of shallow well, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting topipe lines and valves with approved colour (Pipe line exposed above surface) of any size complete all as directed
255Cleaning the internal surfaces of Over Head Tank at 45 m height / staging by scrapping down/brushing and removing all silt dirt, algae etc from walls, floors, washing/ cleaning with water and applying one coat of white wash to all internal surfaces of walls and ceilings complete including writing particulars such as capacity of OH tank, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting to incoming and outgoing pipe lines and valves/valve chambers with approved colour (Pipe line exposed above surface) of any size complete all as directed all as directed by Engineer-in-charge for 100000 Litres capacity
256Cleaning the internal surfaces of Over Head Tank at 15 m height / staging by scrapping down/brushing and removing all silt dirt, algae etc from walls, floors, washing/ cleaning with water and applying one coat of white wash to all internal surfaces of walls and ceilings complete including writing particulars such as capacity of OH tank, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting to incoming and outgoing pipe lines and valves/valve chambers with approved colour (Pipe line exposed above surface) of any size complete all as directed all as directed by Engineer-in-charge for 15000 Ltr capacity.
257Material and Labour Cleaning rain water collection well (depth 3 mtr: meant for collection of rain water and pumping away the collected water by submersible pumps of 7.5 HP during rainy season) by removing all unwanted particles such as mud, sand, dust, dirt, decayed leaves etc. and applying two coats of white wash to all internal and external surfaces of collection well including painting of submersible pumps 7.5 HP and connected pipe lines ( 2 Pump sets in each rain water collection chamber) with synthetic enamel paint of approved colour all as directed by Engineer-in-charge.
258NOTE FOR SL ITEM NO 82 TO 88 - 1. T & P for dewatering UG Sump / Static Tank has to be arranged by the contractor. Rate quoted is inclusive of material and labour required for dewatering. Nothing extra shall be paid separately. 2. All the operations should be executed by trained workers and technicians, properly dressed along with gum boots, safety harness to work as per the direction of Engineer in charge. Contractor shall bring suitable fittings to connect cleanout pipe and suitable length pipe using cleanout facility if available and operational without damaging water tank. Nothing extra shall be paid separately. Contractor shall be responsible for complete cleaning, suction, disposal activity and thereafter. Any damages to water tank during cleaning operation shall be repaired by the Contractor with no cost to MES. Contractor shall ensure and implement safe working conditions for his laborers during execution , all necessary safety measures and harness shall be used before taking-up work. Suitable lighting and ventilation should be provided by the contractor before cleaning of covered tanks. Agency shall be solitary responsible for the lapses in the safety during the work and allied compensations. Nothing extra shall be paid separately, etc. complete as per direction of Engineer In-charge.
259Supply and fix Three phase direct online starter , suitable for7.5 HP Pump/motor. including necessary electrical connections and taking down old unserviceable all as directed.Make : L & Tor equivalent
260Supply and fixSingle phase direct online starter, suitable for0.5 - 2 HP Pump/motor including necessary electrical connections and taking out old unserviceable all as directed.Make: L & T or equivalent.
261Material and labour repair to sluice valve 80 mm dia. ( inside valve chamber and fixed above ground at pumping installations) for smooth operation including replacement of gland packing, bolts, nuts and washers etc cleaning and painting to sluice valve 80 mm dia. with black enamel paint two coats over a coat of red oxide primer all as specified and directed.
262Material and labour for disconnectany size/ model of pump set from the foundation bed to carry out minor repair work such as greasing, gland rope packing, nut & bolts, washers and flanged and complete the correctrotational alignment for smooth functioning all as directed by the Engr-in- charge.
263Supply and fix Gland rope (graphite rope ) (size 1/2",1/4",3/4") suitable for pump size 1 HP-5 HPincluding taking out old unserviceable all as directed.
264Removal of dust and cleaning the Earth pitand washingthe same, applying one coat of white wash , writing the letters such as for Pump set Numberas required at sitewith enamel paint of black colour on pit cover complete all as specified and as directed.
265Sub main wiring with four runs single core 4sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and two runs of 4 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit, 25mm dia/PVC casing capping 32 mmand conduit accessories concealed/surface of wall/roof/ceiling etc complete all as specified and directed. Note: Four runs of 4sqmm and two runs of 4 sqmm cable and one run of 25mm dia conduit/casing capping shall be measured as one unit length.
266Sub main wiring with four runs single core 6 sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and two run of6 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 32 mm dia/PVC casing capping 32 mm including conduit accessories all as specified and directed.Note: five runs of 6 Sqmm cable and one run of 32 mm conduit / casing capping will be measured as one unit length.
267Supply and connecting flat three core, PVC insulated industrial Flat cable for submersible motor, 4 sqmm (Nominal area) with multi stranded copper conductor, 1100 volts grade connected from starter to submersible pump motor complete all as specified and directed.
268Supply and connecting flat three core, PVC insulated industrial flat cable for submersible motor, 6 sqmm (Nominal area) with multi stranded copper conductor, 1100 volts grade connected from starter to submersible pump motor complete all as specified and directed.
269Supply and fix Single phasing preventer & dry run protection relay (voltage based) making necessary electrical connections all as directed by the Engineer-in-charge. Make : L & T
270Material and labour for repairing of 5 HP non- clogging diesel pump set including dismantling replacement of piston and crankshaftbearing, replacing injectors , replacing fuel filters, hand pump , replacing Lub oil ,removing carbon and sludge deposits in crank case and piston , replacing piston rings, replacing air filters, tightening the throttle linkages, lubricating and servicing of pump all as directed and as specified by Engr- in - charge.
271Cutting existing bituminous road and excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth by cutting existing bituminous road not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in any type ofsoil, complete all as specified
272M & L for 100 mm thick cement concrete 1:2:4 type B-1, using 20mm graded aggregate for making good the disturbed road surface after laying of pipe line over returned filled and compacted earth surface to match with existing road level complete all as specified and as directed.
273M & L for PCC 1:4:8 Type D2 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
274M & L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge
275M & L for providing cement concrete 1:2:4 Type B0 using 12.5mm graded aggregate as in copings, complete all as specified and as directed by the Engineer-in-Charge.
276Material and labour for fixing valve chamber cover in replacement, fabricated from MS sheet 3mm thickness, fixing Angle at all sides, with two Nos of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement complete all as specified and as directed by the Engineer-in-Charge.
277Material and labour for demolition of brickwork or stone/boulder masonry, laid dry (Demolition) complete all as specified and as directed by the Engineer-in-Charge.
278Material and labour for preparation of new steel surface and applying two coats of approved colour synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
279Schedule of credit amount brought back from Ser Page No.49- Rs.1,12,793.00will be deducted from the above quoted amount to derive the contract sum. SIGNATURE OF CONTRACTOR