Tender For Repair And Maintenance Of Stp And Connected Work And Replacement Of Lighting Arrester At Various Locations And Fire Fighting Equipments At Map Areaat Sevoke Stn Under Ge Sevoke Road, Kalimpong-West Bengal

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Stp And Connected Work And Replacement Of Lighting Arrester At Various Locations And Fire Fighting Equipments At Map Areaat Sevoke Stn Under Ge Sevoke Road. Submission Date for this Tender is 02-02-2023. Sewage Treatment Plant Tenders in Kalimpong West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

35515600
Corrigendum : Tender For Repair And Maintenance Of Stp And Connected Work And Replacement Of Lighting Arrester At Various Locations And Fire Fighting Equipments At Map Areaat Sevoke Stn Under Ge Sevoke Road
Open Tender
Indian
West Bengal
Kalimpong
02-02-2023

Tender Details

Repair And Maintenance Of Stp And Connected Work And Replacement Of Lighting Arrester At Various Locations And Fire Fighting Equipments At Map Areaat Sevoke Stn Under Ge Sevoke Road

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Jan-2023 DATECORRIGENDUM Date 25-01-2023
2 16-Jan-2023 DATECORRIGENDUM1 Date 02-02-2023
3 23-Jan-2023 BOQCORRIGENDUM BOQ 02-02-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 92000.0 /-
Tender Value
INR 46 Lakhs /-

BOQ Items

Name of Work: REPAIR AND MAINT OF STP AND CONNECTED WORK AND REPLACEMENT OF LIGHTING ARRESTER AT VARIOUS LOCATIONS AND FIRE FIGHTING EQUIPMENTS AT MAP AREAAT SEVOKE STN UNDER GE SEVOKE ROAD
Sl. No. Item Description
1M & L for dismantlingdefective sewage non clog type sewage pump set of 10/7.5HP capacity at site opening suction, delivery pipe line connections,coupling nut bolts and taking out the pump set and transportingto the contractors workshop for repair, machine workand transporting to the site, refixing, assembling coupling with motor,lowering downand connecting suction and delivery line and testing on full load for 04 hours including providing gland packing and making the pump leak proof incl any other minor work as required at site and directed by Engineer-in-Charge. Note:-i) Spare parts replaced shall be measured and paid separately as supply only under respective item of schedule ii)Transportation charges for the motor towksp & back are deemed to be included in rates quoted, no extra payment will be made on this account. iii)Pump set issued for repair must be returned & installed duly repaired within seven days otherwise Rs 500 per day per pump will deducted from the bill as penalty. iv)Minor items like nut/bolts, bearing grease, packing gaskets of required size to be taken in consideration while quoting the rates. No extra payment will be made on this account.
2Supply onlyspare parts for submersible sewage pumpset of capacity10HP
3Impeller sets for one pump
4Mechanical seal set
5Oil Seal
6Rubber gasket sealing
7M & L for rewindingburnt coilsof Induction Motor stator of following capacity with super enamelled copper winding wire as per existing size and guage to achieve therequired /specifiedRPM including taking out old unserviceable winding ,cleaning/ repairing damaged slots , completeall as specified and as directed. Note:-i) Spare parts replaced shall be measured and paid separately as supply only under respective item of schedule. ii)Transportation charges for the motor toworkshop & back are deemed to be included in rates quoted, no extra payment will be made on this account. iii) Motor issued for rewinding must be returned & installed duly repaired within seven days. (iv) Contractor will arrange testing of motor on full load for contineous eight hours. Contractor or his rep will be present on the site during the testing period. v)Minor items like connection plate, copper lugs for cable,connection plate cover to be considered while quoting the rates. No extra payment will be made on this account.
810 HP
97.5 HP
105HP
11Supply only flat submersible cable 3 coremulti stranded copper conductor of size 6 sqmm.ISI marked complete all as specified and as directed.
12Supply onlySteel wire rope, PVC insulated of size 10 mm dia of suitable size/ length and fixed with clamps, nuts & boltsand washers etc for holdingcolumn pipes / GI pipes of submersible pump set complete all as directed by Engr-in-Charge.
13Labour only for inspection of fault in panel,starter, motors and replacement of unsv electronic parts including taking down and testing all as directed by Engr-in -Charge. (Note: 1.spare parts of panel, starter will be paid separately under respective items 2. All T& P and TPT used is deemed to be included in item rate)
14Supply only Power contactor suitable for 5HP of existing make and capacity
15Supply onlyPower contactor suitable for 7.5/10 HP of existing make and capacity
16Supply onlySingle phase preventor suitable for5 HP of existing make and capacity
17Supply onlySingle phase preventorsuitable for 7.5/10 HP of existing make and capacity
18Supply onlyDigital panel volt Meter 3 phaseFlush Mounting 96x96mm, Accuracy Class-I, input voltage measurement range 17-520V AC (P-P)
19Supply onlyDigital panel ammeter, 3 phase 5A,Flush Mounting 96x96mm, Accuracy Class-I, CT/PT Site programmable
20Supply onlyIndicator lamp 3 phase
21Supply onlyElectronic Timer160-500V ,for 3-30sec
22Supply onlyOver load relay suitable for5HP of existing make and capacity
23Supply onlyOver load relay suitable for7.5/10 HP of existing make and capacity
24Supply onlyON OFF push button
25Supply only dry run protection relay
26Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth forlaying of UG cable/pipe in soft loose soil complete all as specified and as directed.
27Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed.
28Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
29M&L for providing sand cushioning for protection of UG cable in trenches with dry (coarse) sand approved quality including filling ,spreading and punning down to desired thickness complete all as specified and as directed.
30Supply and laying burnt clay sub class B brick as cable protection all as specified and directed.
31M& L for laying LT underground Cable, including takingdown existing u/s XLPE insulated, heavy duty armoured sheathed 1100 volts grade 16 Sq mm, 4 core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete incl making necessery cable end connection with lux/tape all as specified and as directed.
32All as per item No 12 above but 10sqmm, 2 core all as specified.
33All as per item No 12 above but 120sqmm, 3.5 core all as specified.
34S & F cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 10 to 35Sqmm, indoor/outdoor type including taking out & relaying damaged cable after repair complete all as specified and as directed.(Excavation and connected items will nbe measured and paid separately.)
35All as per item No 15 above but size 70-150 sqmm 4 core all as specified and as directed.
36Supply and fixing GI pipe 40 mmmedium grade for UG cable protection with all fitting fixed topole or laid in trenches or laid in floor/rood all as directed.
37Taking down existing unserviceable/Faulty LT UG cable 1100V of any size from existing location and relaying the same after necessary repair work all as specified and as directed (Note: Items if required for repair and excavation works will be measured and paid separately under relevant items)
38Relaying of old recovered cable cover or brick of any size in trenches all as directed by Engr-in-Charge
39Supply and fixing cable junction box with terminals having dressed with four colour Tap, having protection"weather proof" for outside installation with metric knockout entry for cable of size 16 sqmm 4 core and size 155x210x92mm with terminals and provision of one MCB SP 6A complete with all pole brackets and fixing arrangements all as specified and as directed.
40M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings with MCB SP in junction box, complete all as specified and directed.
41M&L MCCB 4 Pole,including taking down old u/s having current rating 63-100 Amp, thermal magnetic adjustable 70%-100% breaking capacity 16 KA at 415V,50Hz, Frame size/type CH along with spider links complete all as specified and as directed
42Supply, install, testing & commissioningof approved factory made outdoor cubical typeLT feeder piller Box outdoor type suitable for 3 phase 4 wire 415V,50 Hz, of appropriate size as approved by Engr-in-charge totally enclosed weather, dust vermin proofmade of angle iron frame50mm X50mmX6mm with cable entry and exit through bottomwith double compression cable glands and gaskets and 3.15mm thick panel (cold rolled cold annealed ) front & back side operated double door with properhinge and locking arrangement with Al bus bar fixed on porcelain insulator and shall be complete incld internal wiring using with suitable size of copper conductorcablesand aluminium stripsfor incoming and outgoingconnections of all switches/MCB"s,/MCCB",Bus bar cable alley .Bus bar shall be insulated with colour code/sleeves/tapes including necessary PCC (1:3:6)type C2 for foundation /Platformall as specified and directed.LT panel boardshall be completed in all respects with taking out of unserviceable panel and inclthe following accessories:- Incoming :- (i) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitprotection having double insulation & positive insulation-01 No. (ii) Current transformer 200/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set Outgoing :- (i)Aluminium busbar insulated with coloured tape of rating 500 Amps rating 03 Nos and 01 Nos 400Amps (i) MCCB 200 Amps 4 pole breaking capacity 25 KA-01 Nos (ii) MCCB 125 Amps 4 pole breaking capacity 25 KA-01 Nos (iii) MCCB 63 Amps 4 pole breaking capacity 16 KA-06 Nos thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No. All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer and should be connected with bus bar through bus bar.The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape. Platform for the panel with PCC1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level.
43Supply , installation , testing and commissioning of chlorine feed high pressure dozing pump set with accessories having minimum flow rate of 25 LPH, minimum discharge pressure 15 Kgs/cm2 and liquid chlorine dozing system consisting of atleast 100 ltr FRP tank with accessories and fitted with automatic mixer (non manual) including making connection in main line and fixing arrangement including testing for maintaining 2-3 PPM including taking out u/s dozing pump and remove from site complete all as specified and directed.Note: (i) Unsv dozing pump shall be deposited in MES store yard of AGE E/M Sevoke Road.
44M & L for blocking of incoming sewage water in sump,dewatering desliting / taking out accumulated sludge, Silt, Mudetc. from sewage collection sump and connected channels including scrapping down and cleaning internal surface of walls, Floors, Roofs, Mechanical Parts and cleaning blockage of wash out channels, pipes Drainage system etc. and removing the same to a distance not exc. 50 Metre and reopening of blockage of sump complete all as specified and as directed.
45M & L for cleaning of Equalizing tank /grit chamber/ oil grease chamber/stilling chamber of Sewage Water in thetank and Removing of settle down Sewage sludge cum mud/De-Silting etcall as required at site anddirected by the Engineer-in-Chargefor Sewage tank as per existing size). Note: The rate quoated by the tenderer is deemed to be included in the unit rate of the following as mentioned in Srl item 26.01, 26.02 & 26.03.
46Diesel/ electric Driven Pump Set of appropriate capacitywith operatorsincluding necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes.
47Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved
48Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge.
49M & L for dewatering, desliting / Taking out accumulated sludge, Silt, Mudetc. from FAB Reactor,tube settler tank, TWTand connected channels including scrapping down and cleaning internal surface of walls, Floors, Roofs, Mechanical Parts and cleaning blockage of wash out channels, pipes Drainage system etc. and removing the same to a distance not exc. 50 Metre complete all as specified and as directed. Note: The rate quoated by the tenderer is deemed to be included in the unit rate of the following as mentioned in Srl item 27.01, 27.02 & 27.03.
50Diesel/ electric Driven Pump Set of appropriate capacitywith operatorsincluding necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes.
51Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved
52Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge.
53M & L for blocking of incoming sewage water in sump,dewatering desliting / taking out accumulated sludge, Silt, Mudetc. from sewage collection sump and connected channels including scrapping down and cleaning internal surface of walls, Floors, Roofs, Mechanical Parts and cleaning blockage of wash out channels, pipes Drainage systemcapacity of size etc. and removing the same to a distance not exc. 50 Metre and reopening of blockage of sump complete all as specified and as directed. Note: The rate quoated by the tenderer is deemed to be included in the unit rate of the following as mentioned in Srl item 28.01, 28.02 & 28.03.
54Diesel/ electric Driven Pump Set of appropriate capacitywith operatorsincluding necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes.
55Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved
56Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge.
57Removal of MBBR media from MBBR tank, Tube settler media from tube settler tank, Filter media for DMF and ACF filters and reloading the same after cleaning and new media reloading complete all as specified and directed by Engineer-in- Charge.
58Supply and pouring Bio media made of plastic and corrugated shape having surface area 260 sqm/cum in MBBR as directed by Engr-in-charge. Make: MM Aqua, Bharat, SIMA
59Material for replacement of quartz silica sand 32-64 grade complete all as specified and directed by Engr-in-charge.
60Material for replacement of quartz silica sand 16-32 grade complete all as specified and directed by Engr-in-charge.
61Material for replacement of quartz silica sand 8-16 grade complete all as specified and directed by Engr-in-charge.
62Material for replacement of quartz silica sand 4-8 grade complete all as specified and directed by Engr-in-charge.
63Material for replacement of activated carbon complete all as specified and directed by Engr-in-charge.
64M & L for painting with two coat of black bituminous paint internal surface of ACF /DMF complete all as specified and as directed
65M & L for painting with two coat of silver colour paint external surface of ACF/DMF incl one coat of red oxide after scapping old paint complete all as specified and as directed
66Material & Labour for painting to exposed CI/GI/MS pipe lines of header/suction/delivery of pumps any type/make/size including sluice valves, fittings and non return valves at water supply installations as per specified colour code after cleaning and scraping out old paint including writing/marking complete all as specified and directed by Engineer-in-charge
67S & Fas in repairsDry run protection relaywith detection of single phase preventor,VI meter(current based), 3 Phase Motor Starter or as per existing sizecomplete all as specified and as directed
68Supply, laying , jointing, welding & testing MS pipe ( Heavy duty Class "c") including fitting as required of following sizes laid in treches or laying oe floor for connecting to various STP accessories and to connect outgoing water main including taking down the unserviceable pipe all as directed by Engr-in-charge. Note:- MS flange and flange joint complete with jointing material shall deemed to be included in the unit rate of this item
69100 mm bore
7080 mm bore
7150 mm bore
72Material and labour for CI butterfly valve of following sizes, stainless steel disc as per IS 13095 class PN-1.0 complete with nuts, bolts, washer and rubber gasket including taking out old unserviceable butterfly valve complete all as specified and directed by Engr-in-charge.
7325 mm bore
7480 mm bore
75100 mm bore
76M&L for servicing of air compressor coupled with blower motor 30 HP capacity Installed at Sewage treatment plant including necessary arrangement to transporting to workshop fro re-grinding of shaft, oiling ,greasing etc and necessary replacement of wornout bolts ,nuts ,washers, silencer, belt drivers, pressure guage, air-filter, bearings,ringsetc . Re-assembling the compressure with blower motor , commissioning and testing to the entire satisfaction of Engineer - in - charge .
77Supply only compressure oil all as specified and directed by Engineer - in- charge .
78M&L for replacement of MS Shaft of the electric motor of 30 HP 440 Volts in repairs complete all as directed.
79M & L for dismantling of 30 HP motor,transporting to workshop and rewinding with super enamelled wire of existing guage size, varnishing, heating and refixing motor on its location including testing for 06 hrs continuous run complete all as specified and as directed
80M&L for servicingof 3 Phase 415 Volts 1440 RPMCentrifuge Motor coupled with NC HorizontalMulti staging Pumping Set as following: (a) Taking out Motor from its Position by decoupling from Pump and disconnecting all cable connections, Heating & varnishingto stator with super quality varnish Reassembeling the motor, greasing the bearing with bearing grease ,Reinstall the Motor at its existing Position , couple with the Pump connecting all cable connections and testing on completion complete all as specified by Engineer-in- Charge. b). Taking out Pump from its Position by decoupling from Motor and disconnecting , degreasing bearingand display all the parts without damaging any portion for inspection of Engineer-in- Charge to ascertain the serviceability of existing parts, Replacement of Gasket set and gland packing rope,greasing the bearing with bearing grease ,Reassembeling the Pump complete with all existingserviceable parts, Reinstall the Pump at its existing Position , couple with the Motor and connecting all suction delivery waterconnections and testing on completion complete all as specified by Engineer-in- Charge.
81Surface dressing in hard/dense soil,not exceeding 15cm deep for cleaning the area by cutting the unwanted bushes/vegetation growth in and around the area of installation/around the valve pit chamber/along the pipeline routes if reqd etc all as specified and directed by Engr-in-charge.
82M & L for Scraping old paint of Electric Panel and Painting with two coats of syntheticenameal paint over a coat of red oxide primerincluding disconnecting electric connection and re-wiring without any damage of existing parts as directed by Engnr-in-Charge complete as all specified and as directed.
83S & F in repair outer cover of decanter installed at MAP STP plant of existing size and dimensions including testing of decanter complete all as specified and as directed.
84M&L for cement concrete 1:3:6 type C-2 (40mm graded aggregate) as in foundation and bed concrete complete all as specified and as directed
85Supply and mixing of Sodium hypochloride having 10% chlorine content.
86Supply and mixing of Dewatering Poly Electrolite 100 % Purity.
87Testing of following parameters in discharge water sample obtained from sewage treatment plant through authorised govt. agency:- (i) PH (ii) TSS (iii) BOD (iv) COD (v) Residual Chlorine (vi) Coliform.
88Supply & install test point terminal made out of GI strips 32mm x 6mm with GI nuts & bolts mounted on busbar insulators (02 Nos) fixed on wall complete all as specified and as directed.
89M&L for air termination single pointed aluminium rod 12mm diaand 300 mm long all as specified and as directed.
90M&L aluminium strip 25x3 mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and directed.
91M&L for porceiline insulator suitable for fixing earthing strip to the wall/floor etc complete all as specified and directed.
92S&F galvanised iron strip 32 x 6 mm burried in ground for interconnection of earthing complete all as specified and directed.
93M & Lfor earthing complete with galvanized steel pipe electrode 40mm bore , medium grade, 2.5 meters length, buried directly and preferably vertically in ground with top edge not less than 1.25 meters below ground level connected with earthing lead galvanized iron strip of size 25x5 mm connected to galvanized earth pipe by means of bolts, nuts, checknuts and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanized steel tube for watering with one end fix with cast iron funnel and wire-mesh , with protection pipe of 32 mm dia light grade galvanized steel tubing upto 7.5 meters length for drawing earthlead including common salt, charcol , bentonite in alternate layers etc, complete all as shown in EP number 2 of SSR part-1 including testing on completion and including taking down old u/s earthing & testing complete all as specified and as directed.
94S & F in repair stainless steel 2 way Fire Brigade Inlet connection ISI marked with inbuilt Check Valve including taking down and removed from site complete all as specified and as directed.
95S & F in repair stainless steel 63 mm bore Heavy Duty Single Headed Fire Hydrant Landing valve As per IS:5290 type "A" ISI marked with ABS Blank capincluding taking down unserviceablve valve and removing from site complete all as specified and as directed.
96S & F in repair Hose reinforced rubber lined fire Pipe ofSize 63 mm bore ( 15 Mtr Length ) WithBoth Side SS coupling ISI marked Male & Female connection type including taking down complete all as specified and as directed.
97S & F in repair Branch Pipe with SS Nozzle as per IS 903 ISI marked including taking and removing from site down complete all as specified and as directed.
98S & F in repair of Hosebox made of 18 gange MS sheet 800 mm x 600mm x 250 mm with double door with 4 mm thick glasses and door fram made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete including taking out old unservicebale Hose box and removing from site compelte all on specified and directed.
99S & F in repairHose reel Drum ( Wall Mounted) swingingtype as per IS : 884 includingHose pipe Length 30 Mtr Long of Size:- 20 mm bore thermo plastic hose as per IS 12585, ISI markedwith PVC ¾ “ Shutoff Nozzle (Hydraulically Crimped) including taking down and removing from site complete all as specified and as directed.
100S & F in repair PVC Shut off Nozzle Size 20 mmbore ISI marked including taking down complete all as specified and as directed and removing from site.
101S & F in repair Hose Clamp including taking down and removing from site complete all as specified and as directed.
102S & F in repair 100mm Dual Plate Check Valve :- Cast Iron Body , D.I. Doors ,Nitrile /EPDM Seat ,Stainless Steel Shaft and springs P.N. 1.6 including taking down unserviceable and removing from site complete all as specified and as directed.
103Supply & Refilling of Carbon di Oxide Fire Extinguisher 4.5 Kg each complete all as specified and as directed.
104Supply & Refilling of ABC Powder Fire Extinguisher 6 Kg Each complete all as specified and as directed.
105Supply & Refilling of D-Fire Mechanical Foam Extinguisher 9 Ltr capacity each complete all as specified and as directed.
106Supply & Refilling of Watermist baseFire Extinguisher 9 Ltr capacity each complete all as specified and as directed.
107Supply only following Items:
108Fire Extinguisher Hose Pipe ABC Type
109Fire Extinguisher Hose Pipe CO2 Type
110valve kit for Fire ExtinguisherABC Type
111Fire Extinguisher valve for foam type
112Fire Extinguisher valve forWatertype
113Pressure Meter
114Hanging Clip ( Hooke ) for Fire Extinguisher
115Carbon di Oxide Fire Extinguisher 4.5 Kg each
116ABC Powder Fire Extinguisher 6 Kg Each
117D-Fire Mechanical Foam Extinguisher 9 Ltr capacity each
118Watermist baseFire Extinguisher 9 Ltr capacity each
119Labour only for Control Panel Fault Detection & Rectification by changing Necessary defective Components along with necessary copper wire, Lugs, Terminal etc. including testing complete all as specified and as directed. Note: Spare parts will be measured and paid separately under approprite item
120Supply only following Items:
1213 Pole 32 A Power Contactor
122Thermal Overload Relay ,Relay Range 14-23 A
123Setof 3 Phase Indicating Lamps (Red Yellow & Blue )
124Push Button Assembly with auxiliary contact BlockStart & Stop
12563 Amp TPN MCB10 KA
1261 Pole 2 Way Rotary Cum Switch for Auto & Manual selection
127Single Phase Preventer
128Danfoss Make KP35 Pressure Switch
129Ball Valve 15 mm
130PVC Insulated & PVC Shethed Multi core bright Annealed bare Copper Conductor flexible Round Cables Size 1 Sq mm 2 core FRLSH
131Servicing of motor pump set by disassembling, (i)Motor Front over and back cover part by part dismantling, Internal Coil Heat Varnish, Insulation Testing & refixing. (ii) Pump Part by part Dismantling, ThroughServicing, replacement ofbearing & Gland Packing /Mechanical seal,re assembly with proper alignment complete all as specified and as directed.
132M & L for painting of motor pump set complete all as specified and as directed
133Supply, laying, jointing & testing MS tubing heavy grade 100mm bore with all fittings such as bends, elbow, tee, socket, reducers, unions etc as required at site laid in trenches or fixing complete with clips, wall hooks etc. complete all as specified and directed.