Tender For Construction Of Teja Ji Chowk Rampura Road Rawatsar
Tender Value
15.41 Lakhs
Estimated cost
Bid Submission
09 Jan 2023
0 days left
EMD
30835
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
rawatsar → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Teja Ji Chowk Rampura Road Rawatsar
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P andcaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by Engineer. Cement Concrete Grade M-15 and above and PCC blocks |
| 2 | Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level.In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:4:8 (1 Cement : 4 fine/ coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 5 | Brick work with FPS bricks of classdesignation 75 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 6 | Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix : 1:4 (1 cement : 4 fine/ coarse sand) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level :1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars. |
| 9 | Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. |
| 10 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 11 | Supply and erection of Decorative Cast Iron pole as per approved design of following length with base plate on the cement concrete foundation of M-15 grade (1:1.5:3) with the help of anchor bolts of grade 6.8 (IS 1367 P III). The pole shall be made of Cast Iron as per IS 210:1993, precision machining and filling job to achieve good finish and a fine coat of primer on each element before assembling. After assembling of each element one coat of primer and two coats of P.U. paint are applied. Approved coloured UV resist coating of mat/ glossy/ metallic finish followed after air drying of pole. The pole shall have a weatherproof flush door and locking arrangements, two/ one arm bracket of length of 430/380mm complete in all respect. 2.6 Mtr. group 1 |
| 12 | Provide and fixing of LED POST TOP fixture made form Die cast aluminum graphite grey powder coated finished housing.lycarbonate opal diffuser. Low power Warm White (WW) LEDs connected in series and parallel combination with better Heatdissipation arrangement. Highly efficient constant current electronic driver having operating voltage range from 140- 280 Volt AC;provided with high voltage, open and short circuit protection. Suitable for 60mm OD pipe entry with fixing bolts. Degree ofprotection IP65 LED Make – Nichia/Philips/Osram/Cree or Equivalent LED color temperature range form 3000-5700°K ±300°K. Voltage surge protection 5KV. the luminaire should bear 5 KV surge protection,PF >=0.9(HPF) and total harmonic distortion of THD(I) <10% voltage range of 140-280V. Manufacturer to providecertificate of LM 80 LM 79 form source manufacturer and should have in house adequate testing facilities ( approved by Govt. of India ministry of science and technology/NABL) . Approved LuminaireMake: Philips, Bajaj, Keselec.LED POST TOP 45W |
| 13 | P & F of IP65 IK10 protected LED Bollard fixture. Light Fixture made of powder coated alluminium/Steel housing with diffuser for uniform distribution. The System level Luminous efficacy > 85 Lumen/W. SMD LEDs . CRI>70, CCT: 3000/4000/6000 K. The integral SMPS based electronic driver must be constant current and inbuilt surge protection of min. 4KV(L-N) and efficiency > 85%, PF>0.9 and input Voltage range of 90-270V AC at 50Hz. System life of 50000 burning hours with 70% of Initial Lumens maintained. Light should include quick connecting cable coupled with various mounting accessories. Light output in Cool white or Warm White Colour as per engineers choice. Fixture must be in compliance with IS/CE Standards. 1.0 Mtr Bollard Group 1 |
| 14 | Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI /ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \"A\" attached withthis BSR .Double pole MCB 40 A rating |
| 15 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works withISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , inexisting surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,makingconnections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additionaltechnical parameters of products/ work , refer Annexure \"A\"attached with this BSR.2 x 2.5 sq.mm |
| 16 | Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel not less then 1.2 mm thick Distributionboard as per PWD specification for electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3.Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link ,connecting wire of suitable rating and din bar,masking sheet,including making internal DB terminations with copper lugs and withdetachable gland plate, including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .IP-43 Double door (Three phase)4 Way ( 12 O/G + 8 I/C ) |
| 17 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured / Armoured aluminium cable of 1.1 KV grade as perPWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling ofexcavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as equired of size and as per points (a), (b), (c), mentioned below:-(a) Material :- H4- Grade aluminium conductor of purity >99.6 % &as per IS:1554 P-I / IS :7098 P – I(b) conductor shall have electrolytic aluminium confirming to IS8130, IS 3975-1999 for armouring of cables in armoured cableitems , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testingprocedures.(c) OEM Must have ISO 9001 & 14001 certifications for qualityassuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM testreport shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR.Armoured Cable 6.0 Sq. mm 2core |
| 18 | Painting two coats on specified surface with synthetic enamel paint of approved brand and shade, after thorough cleaning andnecessary filling to give even shade as per clause 803 of MoRT&H Specification including all material, labour.On steel surface |
| 19 | Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately.) Red sand stone. |
| 20 | Providing & applying \"Lime Kara on stone work only\" having carving stone work /decorative stone work (stone pillars, stone arches, railing etc.) as per traditional practice, as per specifications with grinded mortar in two coats with finishing complete in all respect. |
| 21 | Providing and fixing precast cement concrete M-20 grade (Using mechanical Concrete Mixer) kerb stone top and bottom width 115 and 165 mm respectively, 250 mm high on 150 mm thick PCC M-10 grade foundation as per design, including fixing at site as per clause 408 of MoRT&H Specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. |
| 22 | Construction of embankment with approved material obtained from borrow pit with all lifts and leads, transporting to site, spreading, grading to required slope and compacting by vibratory roller 8-10 tonne to meet requirement of table 300-2 including cost of compensation for earth taken from private land complete as per MoRT&H specification clause 305. (Lead taken upto 5 km) |
| 23 | Providing and erecting direction and place identifications retroreflctrorised sign as per IRC:67 made of high intensity grade sheeting vide clause 807.3, fixed over aluminium sheeting 2 mm thick supported on mild steel angle iron post 75 x 75 x 6 mm firmly fixed to ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing. Identification sign board of size above 0.90 sqm |
| 24 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding,buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and boltscomplete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 25 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.South (Red)Upto to 1500 Cm2 Tiles |
AI Tender Summary
Tender Timeline
Dec 29, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedJan 09, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 10, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender