Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #35497345

Tender For Special Repairs To Roof Of Building . No (P-161) At Ins Shivaji And Addn / Altn To Tele Exch Bldg. Necessitated Due To Induction Of Soc Role At Air Force Station Lonavla (8116/E8)

Issued by Statutory Bodies & Commissions/Committees · lonavla, Maharashtra
Tender Value
33 Lakhs
Estimated cost
Bid Submission
10 Dec 2023
0 days left
EMD
66000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
lonavla → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Special Repairs To Roof Of Building . No ( P-161 ) At Ins Shivaji And Addn / Altn To Tele Exch Bldg. Necessitated Due To Induction Of Soc Role At Air Force Station Lonavla ( 8116 / E8 )

BOQ

Name of Work:SPL REPAIRS TO ROOF OF BLDG. NO (P-161) AT INS SHIVAJI AND ADDN / ALTN TO TELE EXCH BLDG. NECESSITATED DUE TO INDUCTION OF SOC ROLE AT AIR FORCE STATION LONAVLA (8116/E8)
Sl. No. Item Description
1Dismantling Mangalore pattern roofing tiles single layer including ridge tiles.
2Dismantling battens for tiles any size exceeding 15cm in spacing.
3Dismantling wooden fillets in rafter purlins etc unframed work under 40 sq cm in sections.
4Dismantling of CGI/PGI sheet roofing any gauge and any thickness including ridge, valley gutter etc.
5Dismantling boarding any description fixed in any position fixed with nails.
6Dismantling timber scantling of framed work 40 sq.cm and over in section and in any position.
7S&F Roof trusses (framed) , trussed, purlin, crane gantries, rails including distance pieces , cleats etc. conforming to Fe 410-w (Gde -E-250) quality -A complete all as specified.
8M&L for prefabricated puf roofing panel with one side manglore pattern sheet & other side plain sheet with slight rib of 0.50mm TCT PPGI (Off white RAL 9002) with 60mm core of polyurethene foam of density 40 Kg/M3 (+2 Kg/M3) fixed with self tapping screws all as per manufacturer\"s instructions including all cutting as required as per site conditions having following specifications complete all as specified and as directed.(a) Top Sheet - Profile as approved by GE.(b) Bottom Sheet - Plain sheet with slight ribs.(c) Panel thickness - 50 mm.(d) Facing material - 300 Mpa Galvalume steel with 150 GMS Aluminium Zinc Coating.(e) Facing material thickness - 0.5 mm TCT.(f) Facing material coating - DFT 20 microns colour coated RMP/SMP/PVDF coating over 5 micron primer.
9S&F Pre painted galvalume aluminium zinc coating GI based plain steel sheeting 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall,eave boards, side capping (Shape as required) fixed with self tapping screws complete all as specified and as directed.
10S&F 0.80 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings(length and girth as fixed) , boarding with zinc coating 120 gram/SqM grade \"O\". Note :- Plain area will be measured for payments irrespective of curve/velly
11S&Fwind ties for roof including securing bolts including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 etc complete all as specified and directed.
12M&L cementconcrete 1:2:4 typeB-1using 20mm graded stone aggregate as in holdfast blocks all as specified
13Demolition of stone/brick work built in cement mortar.
14M/L for brick work with subclass \"B\" bricks, straight, or curved on plan exc 6m mean radius built in CM 1:4
15M&L for Preparation of new surface of steel and applying two coats of synthetic enamel paint over a coat of red oxide primer
16M&L for rendering in patches 10 mm thick in cement mortar 1:6 on walls and finished even and smooth without using extra cement including taking down cement plaster on brick/concrete surfaces and raking of joints, hacking for key, scrubbing down with water & scaffolding etc complete all as specified and as directed.
17M/L for rendering in patches 15 mm thick in cm 1:4 plaster on externalsurface ofbrick walls, concrete surfaces finishing the surface even and smooth without using extra cement and including taking down cement plaster on brick/concrete surfaces and racking out joints, hacking for key scrubbing down with water and necessary scaffoldings etc , complete all as specified and directed .
18M&L for preparation of newly plastered roof surfaces thoroughly by cleaning, washing and removing dust, dirt, oil, grease and loose particles. Cracks less than 2 mm shall be sealed with \"Pidilite URP\" manufactured by Dr Fixit or with \"Plaster seal\" manufactured by STP and cracks more than 2 mm and less than 5 mm shall be sealed with \" crack X wooder\" manufactured by Dr. Fixit or \" Plaster seal\" manufactured by STP and applying primer and two coats of water proof decorative elastomeric coating of approved shade/colour complete all as specified and as directed.Note :- (i) Primer shall be \" Prime seal \"manufactured by Dr. Fixit\" or \"Plaster seal\" manufactured by STP. (ii)Water proof decorative elastomeric coat shall be Rain coat DFT 100 manufactured by Dr Fixit or shalicry 215 manufactured by STP.(iii)The rate of application of primer and waterproofing coat shall be as per manufacturers instructions.(iv)A time gap of eight hours shall be maintained between the application primer and each water proof coat after application of sealant.(v)Unit rate quoted shall be deemed to include for necessary scaffolding for execution of the same.(vi) Application of primer and paint shall be done by the authorised applicator of the manufacturer of the paint and a certificate to this effect shall be produced by the contractor.
19M&L for preparing newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer over and including 3.00 mm thick white cement based wall care putty complete all as specified and as directed.Note:- Application of primer and paint shall be done by the authorised applicator of the manufacturer of the paint and a certificate to this effect shall be produced by the contractor.
20M&L for complete removal of existing treatment of old painted wall surfaces and applying 3.00 mm thick white cement based wall care putty for smooth finish and apply a coat of alkali resistant priming paint over smooth putty surface and apllying two coat of O.B.Dover priming coat surface of wall .etc of approved make & shade on walls and other places complete all as specified and as directed.
21Complete removal of existing treatment of external surface of wallincluding removing fungus /algae dirt, oil, grease and loose particles by wire brush,cleaning, washing and removing dust, . Cracks less than 2 mm, should be cleaned free of dust with a vaccum cleaner and apply Dr. Fixit Primeseal (Efflorescence resistant penetrating primer.) let it dry. Then pour Dr. Fixit Raincoat into these cracks and wait for it to dry Apply the first coat of Dr. Fixit Raincoat without any dilution at the rate of 2 sqm per litre and allow it to dry before taking up the second and third coats, the rate of application being the same, Drying time between coats will be 6 to 8 hrs, A total thickness of 1 to 1.2 mm must be achieved when Dr. Fixit Raincoat is dry and including necessary scaffoldings etc , complete all as specified and directedNote:- Application of primer and paint shall be done by the authorised applicator of the manufacturer of the paint and a certificate to this effect shall be produced by the contractor.
22M&L for filling cracks with polymer based chemical (Dr fixit cracks shrink free ) for cracks not exc 10 mm in width as per manufacturer instruction on wall surfaces on concrete or masonary including scaffolding etc complete all as specified and directed. Make:- Dr fixit /Berger / Perma
23Dismantling Wall and ceiling boards of any type or insulation boards/slabs/blankets, any thickness, including cover fillets etc complete all as specified and directed.
24M&L for powder coated aluminium snap grid frame work for false ceiling, with aluminium angle 25mmx25mmx1.5mm fixed to perimeter of wall, Main \"T\" runner 38mmx25mmx1.5mm and secondary/cross \"T\" runner 25mmx25mmx1.5mm to be interlocked in such a way that the size of grid shall be 605mmx 605mm including 6mm dia GI hangers (upto 1200mm length) adjusting level fixed to roof bymeans of ceiling cleats made out of GI flat 40x3mm, 60mm long and expansion hold fastners 12.5mm dia, 40mm long complete all as specified and as directed. Note:- The thickness of the powder coating shall not be less than 0.5 micron & the tint shall be as decided by GE.
25S&F 4 mm thick Non Asbestos (E-board) designer tiles (Electra) suitably fixed in false ceiling grid /frame with staples or screws complete all as specified and as directed.
26M&L for preparation of old painted wood surfaces of any description having width/ girth execeeding 10cm and apply one coat of synthetic enamel paint complete all as specified & as directed.
27M & L for Preparation of old painted steel surfaces of any description having width/girth exceeding 10cm and apply one coat of synthetic enamel paint complete all as specified and as directed.
28Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
29Dismantling floor, hearth or wall tiling including cementmortar beddingremoving serviceable tiles and rubbish off the premises etcand removal of rubbish/ demolished materials out of MD landcomplete all as specified and directed.
30M&L for Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 etc: complete all as specified and directed.
31M&L for vertified ceramic tiles 10mm (light shade of square/ rectangular) polished,area of each tilesnot exc 0.36 sqmin floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match etc, complete all as specified and directed.
32S&F aluminium powder coated (powder coating shall not be less than 0.5 micron) single/double leaf, partly glazed & partly panelled door in two panels having 12mm thick both side laminated MDF board in bottom panel and 5mm thick toughened tinted/plain glass in top panel on pivots alongwith hydraulic door closer (Aluminium Extruded section) brass door lock with four levers, 02 Nos of handles with rubber beading and glazing clips and using followingpowder coated aluminium section as mentioned in JINDAL catalogue complete all as specified &as directed :- Frame-14005, shutter vertical-19550 Top rail-19563, Middle rail-19525, Bottom rail- 19563, glazing clips- 19352 & Handle- 18566
33S&F aluminium powder coated partition, partly panelled & partly glazed with 12mm thick both side laminated MDF board in bottom panel and 5mm thick toughened tinted/plain glass in top panel fixed with clips, aluminium beads, rubber gaskets etc, centre to centre distance of vertical member shall n.exc 1mtr and horizontal members shall n,exc 1.10 mtr using following aluminium powder coated section as mentioned in JINDAL catalogue complete all as specified &as directed :- SP-20048, DP-20047 & glazing clips- 19352
34S&F of 4mm thick\"E\" classic designer board false ceiling with powder coated GI snap grid frame work of grid size 600 x 600 mm including cutting holes in brick wall built in cement mortar & making good in cement concrete 1:2:4 type B 0 Cement motar 1:3 complete all as specified and directed including all necessary drilling and necessary arrangement to fix items as under :-(a)27x27x0.55 mm thick GI angle powder coated duly plugged @ 600mm centre to centre alongwith perimeter of wall.(b) 25x25x0.55 mm thick GI tee powder coated as main and cross runners suspended with 1.6mm dia GI wire suspenders (n.exe 1.2 mtr length) with adjustable clamps and dash true fastners plugging in RCC slab/wooden truss/A.I Runner of slopped roof placed @ 600mm centre to centre from perimeter of wall.(c) Fixing of 4mm thick AC \"E\" Classic designer board of approved texture and finished complete.Note. The complete ceiling work shall be done as per manufactures instruction and as directed.
35S&F solid PVC WallLining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications
36S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification.
37M&L 5mm thick Rubber sheet with fabric backing or insert and plain coloured or marbled topping, matt or glossy , laid in floors with approved adhesive
38M&L for cement concrete in foundation, filling and mass concrete type C-2, 1:3:6 using 20mm graded aggregate as in foundation and sub base complete all as specified and directed.
39S&F wood any colour 3 seater linear modular office workstation size 1.2X0.60RM total 3.60RM length.45mm thick partiton panel height 1.2m with 3 Nos detachable drawers.(Photocpy of the same enclosed)
40M & L for Point wiring with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and includingproviding PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed.(a) One light point or one fan pointor bell point controlled by one switch
41(b) One 3 pin socket outlet, 5 Amp independent
42(c) One 3 pin socket outlet, 5 Amp on the same board with other switches
43All as per item No.2 here in before but wiring with cables of size 2.5 sqmm for wiring & cables of size 2.5 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and directed. (Note : cutting chases & making good of disturbed surfaces shall be measured and paid separately).
44S & F switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and as directed.
45S & F socket out let, 2 in 1, 3 pin,5 Amps, 240 volts complete all as specified and directed.
46S & F Switch socket combination, 2 in 1,5 Amps,flush type, 240 volts complete all as specified and directed.
47S & F Switch socket combination, 5 in 1, 5/15 Amps, 240 volts, flush type complete all as specified and directed.
48S & F Ceiling rose, 3 way PVC insulated bodycomplete all as specified and directed by engineer in charge.
49S & F Skylux GZi WH Series Recess mounted LEDdesigned high efficiency ,less THD value for operation & electical efficiency,LED Recessed 2 x 2 luminaries 36W, including complete all as specified and directed by Engg-in-charge.Make :- Bajaj (BZRSQL 36L LED GX D WH,SD ) or equivlent Crompton/Philps/Shakti.
50S&F in replacemen MCB DB SPN 8 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surfaceall as specified and directed
51S&F in repairs MCB SPN 40 to 63 AMP,240 Volts , Complete all as specified and directed.
52S&F in repairs MCB SP 5 To 32 AMP,single pole 240 Volts , Complete all as specified and directed.
53S&F in repairs MCB SP 32 to 63 ,single pole 240 Volts 10KA , Complete all as specified and directed.
54M&L sub main wiringof PVC FRLS insulated unsheathed two single core 4.00sqmm copper multi stranded conductor including one run of single core copper conductor of size 2.5 sqmm as earth wire drawing into PVC conduit on surface completeall as specified and directed.
55M&L for sub main wiring drawing through PVC casing and capping with four runs of single core 6 sq mm and two runs of 6.0 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts gradeall as directed.Note:- Two run of 6 sqmm wire and One run of 6 sqmm wire and One run of PVC casing caping will be measured as one running meter.
56Removing and Re-fixing hi wall split unit AC Cap 2.0 Ton indoor/outdoor complete with all accessories (copper pipe,drainge pipe,enclouser,voltage stablizer,MCB,Gass filling etc) completeall as specified and directed. (NOTE : (a) all damage items of AC parts with accessories and gas refilingdone by contrector (b) All making holl for pipedoing by drilling and after drillngmaking good of disturbed surfaces done by contrector.
57M &L for Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A 240 Volt all as specified and directed
58M&L MCB SPN 32 Amp,240 Volt complete all as specified.
59M&L sub main wiringof PVC FRLS insulated unsheathed two single core 4.00sqmm copper multi stranded conductor including one run of single core copper conductor of size 2.5 sqmm as earth wire drawing into PVC conduit on surface completeall as specified and directed.
60Chair CBA Steel with paded arms and padded cushion (Drg No - FD-75 (M))
61Book case with glass doors (Drg No - FD-356/90 (M))
62Sofa 5 seater (Drg No - FD/MAP - II/02)

AI Tender Summary

OUR REF NO 35497345
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 33 Lakhs
LAST DATE 10-12-2023
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repairs To Roof Of Building . No ( P-161 ) At Ins Shivaji And Addn / Altn To Tele Exch Bldg. Necessitated Due To Induction Of Soc Role At Air Force Station Lonavla ( 8116 / E8 )
Basic Detail
Tender No GE/LONAVLA/8116/E8
Bidding Type Tender
Location
City lonavla
State Maharashtra
Key Dates
Publish Date 28 Dec 2022
Submission Date 10 Dec 2023
Open Date 12 Jan 2023
Finance
Tender Value 33 Lakhs
Tender Fee 500
EMD 66000
Exemption Not Available
Document List
BOQ_640340.xls
Tendernotice_1.pdf
dbb67db6-92ad-4385-9e1f-761da4f4ad81.html
2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 28, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 10, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 12, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_640340.xls

pdf

Tendernotice_1.pdf

html

dbb67db6-92ad-4385-9e1f-761da4f4ad81.html

pdf

2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders