Tender For Annual Repair And Maintenance Of 15 Nos Bops Kalatila Reangbasti Reangfwd Sanjay Shivbari Sonarai Morachera Dhalai Malaya Baligaon Amtoli Chanan Rajkandi Bilaschera And Rangichera Of 105 Bn Bsf Under Shq Bsf Panisagar Sh Electrical Work
Tender Overview
Project Description
Annual Repair And Maintenance Of 15 Nos Bops Kalatila Reangbasti Reangfwd Sanjay Shivbari Sonarai Morachera Dhalai Malaya Baligaon Amtoli Chanan Rajkandi Bilaschera And Rangichera Of 105 Bn Bsf Under Shq Bsf Panisagar Sh Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and fixing 5/6 amps piano type switch on the existing switch box/ cover including connections etc. as required. |
| 2 | Supplying and fixing 3 pin 5/6 amp socket outlet piano type on the existing switch box/ cover including connections etc. as required. |
| 3 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 4 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 5 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 6 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 7 | Supplying and drawing 3x1.50SQMM of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 8 | Supplying and drawing 2x6 SQMM of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 9 | Supplying and fixing 15/16Amp modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 10 | Supplying and fixing 15/16Amp modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 11 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 12 | Supplying and fixing of 20 MM sizes of medium class PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 13 | Supplying and fixing 15/16Amp piano type switch on the existing switch box/ cover including connections etc. as required. |
| 14 | Supplying and fixing 15/16Amp piano type socket on the existing switch box/ cover including connections etc. as required. |
| 15 | Supplying and fixing 08 way, Double door , single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) |
| 16 | Supplying and fixing 5 amps to 32 amps rating, 240 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of Single Pole, \"C\" series in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 17 | Supplying and fixing 5 amps to 32 amps rating, 240 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of Double Pole, \"C\" series in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 18 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch,phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single coreable etc as required. Group \"A\" |
| 19 | Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonary enclosure with cover plate, having locking arrangement and watering pipe etc. with charcoal or coke and salt as reqd. |
| 20 | Supplying and Layingearth connection electrode with 6 SWG dia. G.I. wire in 15 mm dia G.I. pipe from earth electrode i/c connection with GI thimble excavation and re-filling as reqd. |
| 21 | Supplying and Laying6 SWG G.I. wire on surface or in recess for loop earthing as reqd. |
| 22 | Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 23 | Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 24 | Supplying and makingend termination with brass compression gland and aluminium lugsfor 3.5 X 120 sq. mm (45mm) of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 25 | Supplying, Installation, testing and commissioning of Switch Type steppedelectronic Mini fan regulator 120/280 Volts, in existing switch box including connection with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc as required. |
| 26 | Supplying,installation,testing & commissioning of 20/22 watt LED tube light fitting suitable for single phase AC complete with connection etc as required. |
| 27 | Supplying and fixing PVC batten/ angle holder along with 9/10 Watt LED lamp including connection etc. as required. |
| 28 | P/F of LED street light , 90 watts , i/c 32 mm dia pipe bracket of required shape. The fitting should be fitted on the wall/surface/pole by means of clamping arrangment i/c nut&bolts etc as required. |
| 29 | SITC 0F 1HP Monoblock Motor pump set 240 Volt 50 Hz, single phase, outlet size 40mm in the existing 40mm dia medium class GI pipe column joint with bolts in openwell/outside etc. as required. |
| 30 | Supply ,Installation, testing and commissioning ofExhaust fan metal type( ventilating fan ) 300 mm sweepsingle phase 230 v 50HZin the existing opening i/c making hole of suitable size and making good the damage connectionetc as required |
| 31 | Supplying and fixing louvers/ shutters complete with frame forexhaust fan of 300 mm sweep etc. as required. |
| 32 | Supply and fixing of Ceiling linear LED lighting fixture (for mirror light)having specification of 09 watts rated with 240V AC operation of model as per requirement with all accessories like LED driveretc. as required. |
| 33 | Dismantling of existing wiring, conduit, switch boards and making goods the damage plastering of holes painting, finishing work complete etc as required. |
| 34 | Supplying and Laying of one number PVC insulated and PVC sheathed/ XLPE power Aluminium cable of 1.1 KV grade of 3x120 SQMM size armured cable direct in existing HDPE/RCC/HUME/METAL PIPE etc as required, but excluding sand cushioning and protective covering. |
| 35 | Add labour cess @1% on total Amount andround off amount |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender