Tender For Renovation Strengthening Of Ei, Fans, And Submersible And Other Allied Electrical Work At M And Cw Centre Sarai Mohalla In Ward No. 31E Under Ssz
Tender Value
3.88 Lakhs
Estimated cost
Bid Submission
04 Jan 2023
0 days left
EMD
7800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Shahdara → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Renovation Strengthening Of Ei, Fans, And Submersible And Other Allied Electrical Work At M And Cw Centre Sarai Mohalla In Ward No. 31E Under Ssz
BOQ
| Sl. No. | Item Description |
| 1 | EarthingwithG.I.earthpipe4.5metrelong,40mm dia includingaccessories,andprovidingmasonryenclosurewith cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 2 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 3 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with piano type switch, phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc. asrequired.Group C |
| 4 | Rewiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable and 1.5 sq.mm FRLS PVC insulated copperconductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.Group-C |
| 5 | supply and fixing of following sizes medium class pvc conduit along with accessories in surface / recess including cutting the walland making good the same in case of recessed conduit as required a)25 mm |
| 6 | Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3x2.5 sq.mm |
| 7 | 3x4 sq.mm |
| 8 | Supplying and fixing following piano type switch/ socket on theexisting switch box/ cover including connections etc. as required. 5/6 amps switch |
| 9 | 15/16 A switch |
| 10 | 3 pin 5/6 A socket outlet |
| 11 | 6 pin 15/16 A socket outlet |
| 12 | LayingandfixingofonenumberPVCinsulatedandPVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 13 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm |
| 14 | supply of XLPE PVC SheathedAl. Conductor Armoured Cable for working voltage upto 1.1kV confirming to IS-7098(Part-I) of following sizes: 2 x 10 sq.mm |
| 15 | 4 x 25 sq.mm |
| 16 | supply and fixing of Metal box 180mm x 100 mmx 60 mmdeep (nominal size) on surface / recess with suitable size of phenolic laminated sheet cover infrontincluding providing and fixing 6 pin5/6 &15/16A socket outlet and 15/16A piano type switch ,connection painting etc as required. |
| 17 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker single polesuitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 18 | Supplying and fixing 63 Amprating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 19 | Supplying and fixing Single pole blanking plate in the existing MCB DB complete etc. as required |
| 20 | S& F of compartment cubical type panel board duly powder coated made out of16 SWG MS Sheet with insulated aluminium bus bar i/c interconncetioncopper wiring arrangment for mounting for switch gears, change over swichtes,MCCB i/c making the foundation brick work/ angle iron frame on floor/wall with proper locking arrangement etc. complete as required at site. Depth 30 to 60 cm |
| 21 | Providing and fixing following Rating and breaking capacity MCCB WithThermomagnaticreleaseandTerminal Spreaderin existing cubicalpanel board including drillingholes in cubical panel ,making connection etc as required.disconnector fuse switch unit inside the existing panel board with ISI Marked HRC fuses including drilling holes in cubile panel making connection etc as reqd. 200A,16KA,TPMCCB |
| 22 | 100A ,16KA,TPMCCB |
| 23 | Providing and fixing following capacity TP&N disconnector fuse switch unit,sheet enclosure typewith side handle operation , ISI mark,making connections, etc. as required.200A ,TP&N |
| 24 | Supply and fixing of 4.5 Kg DCP with COCO2 fire extinguisher (wall mounting type)gas cartridge fire extinguisher (conforming to IS: 2171 with cylinder fully charged) |
| 25 | SITC of 60W LED Flood Light luminiare fitted with lense, made of pressure die cast aluminium housing & toughned glass cover complete with the following specification as reqd.. (b) Total system wattage =60 watt +/- 5%c)Luminaire Efficacy>=100 Lm/wd) Power Factor>=0.95sf) Protection IP-66 |
| 26 | supply and fixing of 400mm single phase swing wall fan as reqd. |
| 27 | Supplying and fixing following rating, four pole, (three phaseand neutral), 415 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DBcomplete with connections, testing and commissioning etc. asrequired.63A |
| 28 | SITC of single phase/three phase monoblock pump set complete with allaccessories workable on 240/415V ,50HZ ac supply 2hp single phase pump set head from 12-30 meter suction and delivery 25*25mm |
| 29 | P&F ofwater/weather proof junction/pole box made out of 16 SWG MS sheet steel of size200x150x100mmdeep dully painted complete with one No SP-MCB(6to32Amp) and neutral link & locking arrangement etc as reqd. |
| 30 | Supplying and fixing metal box of following sizes (nominal size)on surface or in recess with suitable size of phenolic laminatedsheet cover in front including painting etc. as required.180 mm X 100 mm X 60 mm deep |
| 31 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door |
| 32 | SITC of surface mounting LED luminaire suitable for 1X20 watt LED rating complete with extruded aluminium batten prewired with high efficient LEDs with the following: a) Total System Wattage 20 ±5% Wattb) Luminaries effucacy = 100 lumens/watt c) Power factor = 0.95 |
| 33 | SITC of 45W LED street Light luminiare fitted with lense, made of pressure die cast aluminium housing & toughned glass cover complete with the following specification as reqd... (a) Total system wattage =45watt +/- 5%b)Luminaire Efficacy>=100 Lm/wc) Power Factor>=0.95d) Protection IP-66 |
| 34 | Supply and fixing of 32 mm dia G. I pipe ( Medium class) 1 mtr long bracket 1/c wiring with 2.5 sq mm copper conductor wire as required. |
| 35 | supply and layingof 6 sq mm aluminium conductor PVC insulated flat twin core W/P wire complete as required |
| 36 | Supply of 15\" (380mm) sweep 1400 rpm exhaust fan fan heavy duty complete with shutters, blades etc as reqd. |
| 37 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 38 | Providingand fixing of invertor of 2000 VA2 Nos 150 AH Batterieswith trolley suitable for keeping 2 Nos Batteryand 1 no inverter i/c wiring & connections etc as reqd. |
| 39 | Supply, Installation, Testing and Commissioning of 1200mm sweep, BEE 5 star rated, ceiling fan with Brush LessDirect Current (BLDC) Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, Power Factor not less than0.9, Service Value (CMM/W) minimum 6.85, Air deliveryminimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulatorunit for speed control and all remaining accessoriesincluding safety pin, nut bolts, washers, temperaturerise=75 degree C (max.), insulation resistance more than2 mega ohm, suitable for 230 V, 50 Hz, single phase ACSupply, earthing etc. complete as required. |
| 40 | Rewinding of AC ceiling fan / Exaust fan of all sizes and make i/c oiling, greasing as required. |
| 41 | SITC of Desert cooler in metalic body of 18mm gauge ,12 inch deep capacity with fan of 18 inch size having 3 blades heavy duty motor with iron angle stand as per required size and design |
| 42 | Supply of 1.5 Ton Window Air Conditioner ( 5 star rating) ( copper conduncer) along with cu cableremote suitable for,230 V +- 10 %electric supply as reqd. |
| 43 | P&F of 4 KVA Voltage Stabilizer with TDR and Triple step, High & Low voltage Cutt off device complete as reqd. |
| 44 | Standard Installation charges for Window AC including labour and petty items reqd. for the installation of the same as complete as reqd. |
| 45 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required.D) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 46 | Lifting of existing submersible pump set with its all acecessories form well and lowering the same along with all accessories from depth50 meter to 100 meter complete as required |
| 47 | supplying,lowerig,testing and commissioning of following capavity vertical type ,multistage, totally enclosed ,water filled, deep well sumbersible pumping set complete i/c connection etc a required a single phase 1.5 H.P. having discharge of 72 LPM at 49 M head |
| 48 | P and F following sizes of PVC insulated and PVC sheathed copper conductor 3 core submersible cable confirming to IS.647/1990 etc. as reqd. Elec94.a 3 X 2.5 sq.mm. |
| 49 | Supply, installation, testing and commissioning of cubical type control panel board for single phase submersible pumping set of following rating complete with contractor, relay, M.C.B, condenser, Voltmeter, ammeter and indication lamp etc including connections as reqd. )A)-1.5 H.P. rating submersible P/Set. |
| 50 | Supply, lowringand fixingfollowing sizeG.I. pipes(M-Class)i/ccutting, threading on both side etc ISI Markedas reqd. 25 mm dia nominal bore |
| 51 | Supply, lowringand fixingfollowing sizeG.I. pipes(M-Class)i/ccutting, threading on both side etc ISI Markedas reqd. 32 mm dia nominal bore |
| 52 | SITC of floor mounted hot, cold and normal water dispenser having cold water storage capacity 3.2 liter, cooling capacity 3 liter per hour, flow rate 3 liter per hour, hot water storage capacity 1 liter , heating capacity 5liter per hour etc as required. |
AI Tender Summary
Tender Timeline
Dec 28, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedJan 04, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 05, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender