Tender For E-Quotation For Electro-Mechanical Components By Supplying And Fitting And Replacing Of Electro-Mechanical Components Of Baharagora Multi Village Rural Water Supply Scheme, jamshedpur-Jharkhand

Drinking Water And Sanitation Department has published Tender For E-Quotation For Electro-Mechanical Components By Supplying And Fitting And Replacing Of Electro-Mechanical Components Of Baharagora Multi Village Rural Water Supply Scheme. Submission Date for this Tender is 03-01-2023. Coats and Jackets Tenders in jamshedpur Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

35489091
Tender For E-Quotation For Electro-Mechanical Components By Supplying And Fitting And Replacing Of Electro-Mechanical Components Of Baharagora Multi Village Rural Water Supply Scheme
Open Tender
Indian
Jharkhand
jamshedpur
03-01-2023

Tender Details

E-Quotation For Electro-Mechanical Components By Supplying And Fitting And Replacing Of Electro-Mechanical Components Of Baharagora Multi Village Rural Water Supply Scheme- 1 BOOSTING P/PLANT W.T.PAT Mohanpur of Bahragoda RWSS Cost towards supply installation and testing and commissioning of Horizontal split casing type centrifugal pump Make-Mather &Platt/Kirloskar /WPIL capable of discharhing-100 m³/hr clear water against total head 30 meters, coupled with suitable 3 phase. 1440 RPM, 50Hz TEFC sq. cage induction motor Make-Kirloskar, CGL/ABB mounted on a common M.S. Channel fabricated base plate with following accessories-1. Sutable size N.R Valve1 No2. Sutable size sluice Valve 1 No3. Sutable size Check Valve/Foot Valve1 No4. Pressure gauge1 No5. M.S Base Plate 1 No6. Tyre coupling set 1 Noetc all complete. 2 Cost towards dismantling of old Foundation and removing the residuals out of the pumping plant and Making of New PCC foundation 4’x3’ x2.5’ size & M.S joint 4”X6”-2 nos. with supplying all mortar materials & foundation bolts 6 nos. with all labour tools and tackles loading unloading with alignment leveling and jointing as per P.W.D Specification (1:2:4) etc all complete. 3 Cost towards supplying Installation & commissioning of 160 Amp, 440 VMotor Panel Board made of 2mm thick MS sheet of suitable size, dust and vermin proof consisting of following accesories :(i)160 Amp MCCB – 1 No.(Incoming feeder) (ii)100 Amp MCCB – 02Nos (outgoing feeder). (iii)32 Amp MCB -1 No. for lighting load and other utiliti load.(iv)FASD Starter suitable for the 12.5 HP Motor Pumpset – 2 Nos.(L&T make)(v)Copper Bus Bar- 4 pole 160 amp 415volt copper strip bus bar enclosed in MS sheet, etc. all complete job. (vi)LED display Voltmeter – (0-500 V) & Amp Meter(0-100A) – 2 Sets, Phase indicating lamp-6 Nos.Along with overload relay, single phase preventer proper inside wiring with suitable size of copper conductor with wall/floor mounting facility, Cubical panel box etc. all complete including transportation and fitting and mounting charges at P/Plant. 4 Cost towards repairingof 63 KVA transformer with changing of HT & LT bush-3 sets each , Top-up transformer oil upto-100 ltrs, fuse wires as per required. 5 Cost towards supplying and laying of 3core 95 sq.mm aluminium armoured cable from transformer to MCP 6 Cost towards Chemical earthing 40feet and 80mm hole size with electrode and chemical compound etc. with watering pipe and locking arrangements including soldering, riveting, jointing G.I. flat strip 20mm X 3mm to all equipments. 7 Cost towards supplying and installing 100 watt LED street light complete set all complete including labour charges. For clear water p/plant. 8 Cost towards supplying Installation and commissioning of 63 KVA Servo controlled (oil cooled) automatic voltage stabilizer suitable for output voltage of 415 + 1% 3 phase, 50 Hz with copper wound transformer as mentioned below. The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%.The stabilizer should be constructed in cubical box,with bidirectional wheels for easy handling necessary monitors and user’s controls on front panel such as inducation alarm, voltmeter and selector switch for measuring input and output voltage auto manual selector switch.Raise low push buttons etc. suitable capacity termination strips and bus bars for incoming and outgoing cable should be provided .All three phases shall be independently monitored and corrected following protections and indication shall be incorporated as per IS:9815a) Over Voltage/Under Voltageb)Single Phasing c) Cut off contactorwith electronic output sensing unit d) Suitable change over switch and earthing 100 KVA Oil cooled Servo controlled automatic voltage stabilizer (output 415 unit+ 1%) Input 280 to 450 Volt. Make: Powerline/Servokon 9 Cost towards of Changeover switch TPN on load with sheet sheel enclosure Capacity Amp for by pass arrangement of servo voltage stabilizer Make C&S Havell s/L&T with all labour & tools and materials. 10 Supplying and laying of 25 sq.mmx3core x1.1 Kv grade with ISI make PVC insulated and unarmored flexible copper cable from MCP to motor terminal box with suitable copper lugs etc 11 PART –BRAW WATER PUMPING PLANT – INTAKE WELL AT JAMSOLA Providing all labours, tools, Tackels and technician fordisconnection and taking out20 HP VT P/Set with column pipe into intake well all complete. 12 Cost towards all labour, tools, tackles and technicianfor opening, dismantling. repairing and overhauling of20 HP 04 stage bow l assembly VT pump having head58 meter. discharge- 43m3/hr speed 1460 rpmi. With S/F of S.S. pump shaft-- 01 No.ii. Top and bottom bush- 02 Nos.,iii. Intermediate bushes -5 Nos.iv. Spider cut less rubber bushes- 04 Nos.v. Locks Vi. Impeller copper bush-06 Pcs.vii. G.M. impeller- 04 Nos. viii. 30mm diaS.S. line shaft-10 ft each 3 nos.ix. 30mm dia. SS.head shaft- 5 ft. each I Nos.x S. S Socket and bush-04 Nos. each. xi, Ferro collar ball rubber bush -12pc xii. Ball sleeve bush-07 Nos each all materials as per required reassembling the same at workshop refitting at site etc. all complete(Rate after deducting the scrap materials). 13 Providing all labours, tools, Tackels and technician forloweringafter repairing of20 HP VT P/Set with column pipe into intake well all complete. 14 Cost towards supplying all labour tools and tackles for Complete opening, dismantling. of 20 HP 440 Volt,50c/s, star delta, 3phase VT motor by supplying supperenameled copperwireandthentapping,varnishing, heating & testing on lull load and repairing of stator and rotor with including the deduction of cost of burnt copper wire approx. 18.5 kg.With changing of following bearing:- (i) Ball bearing -as per sample-01 No. and (ii) Thrust bearing as per sample (SKF Make) at raw water p/plant. 15 cost towards transportation charges of above pump motor set and other linings materials from p/plant to workshop and vice versa. 16 Supplying and laying of 25 sq. mm x 3 core X 1.1 KV grade with ISI mark PVC insulated and unarmoured flexible copper Cable from MCP to motor terminal box with suitable copper thumble socket etc. 17 S/F of 90 watt LEDFloodlighting luminaire with pressure die cast housing and toughened glass cover, operating voltage range 100V-270V AC with structure,stand, clamp, tee, wires and switches etc. all completeincluding repairing of lighting arrangements inside and outside of pump house at raw water p/plant. 18 Costtowardssupplying andfitting of lighteningarrester suitable for building protection with EarthingElectrode ,Earthing Compound, copper wires and earth work etc. all complete job. 19 Cost towards replacement of old panel by supply installation & commissioning of new standing type floor mounting industrial panel board comprising 200 amp copper bus bar nos. in M.S Steel(14SWG) Housing.•200 amp T.P.N MCCB make L&T as incomer feeder.• 100 amp T.P.N MCCB make L&T 2 nos as outgoing feeder.• Ammeter-digital ammeter with selector switch L&T/C&S make• Voltmeter- Degital voltmeter in 3 phase RYB• Indicating lamp LED- L&T/SIEMENS/C&S make in Red, Yellow and Blue colour 1 set.• 32 amp MCB for light load and other loads of L&T /Havel’s/C&S make (2 no.)• FASD starter (Make-L&T) Suitable for above pump set. Panel should be dully painted with two coats super enameled paint of approved color one coat of red oxide primer and internally wired with suitable size of copper wire etc. all complete. 20 Cost towards supplying Triple spur gear type chain pully block of 3 tonne capacity with 6m lift complete with load chain and hand chain suitable for above lift, tested to 50%over load as per IS 3832 carrying ISI mark with travelling trolley etc. 21 Cost towards of Changeover switch TPN on load with sheet sheel enclosure Capacity Amp for by pass arrangement of servo voltage stabilizer Make C&S Havell s/L&T with all labour & tools and materials. 22 Cost towards supplying and laying of 3core 95 sq.mm aluminium armoured cable from transformer to MCP 23 Cost towards supplying Installation and commissioning of 63 KVA Servo controlled (oil cooled) automatic voltage stabilizer suitable for output voltage of 415 + 1% 3 phase, 50 Hz with copper wound transformer as mentioned below. The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%.The stabilizer should be constructed in cubical box,with bidirectional wheels for easy handling necessary monitors and user’s controls on front panel such as inducation alarm, voltmeter and selector switch for measuring input and output voltage auto manual selector switch.Raise low push buttons etc. suitable capacity termination strips and bus bars for incoming and outgoing cable should be provided .All three phases shall be independently monitored and corrected following protections and indication shall be incorporated as per IS:9815a) Over Voltage/Under Voltageb)Single Phasing c) Cut off contactorwith electronic output sensing unit d) Suitable change over switch and earthing 100 KVA Oil cooled Servo controlled automatic voltage stabilizer (output 415 unit+ 1%) Input 280 to 450 Volt. Make: Powerline/Servokon

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work:E-Quotation FOR Electro-mechanicalcomponents by supplying and fitting and replacing ofElectro-mechanical Components of BAHARAGORA Multi village Rural Water supply Scheme
Sl. No. Item Description
1BOOSTING P/PLANT W.T.PAT Mohanpur of Bahragoda RWSS Cost towards supply installation and testing and commissioning of Horizontal split casing type centrifugal pump Make-Mather &Platt/Kirloskar /WPIL capable of discharhing-100 m³/hr clear water against total head 30 meters, coupled with suitable 3 phase. 1440 RPM, 50Hz TEFC sq. cage induction motor Make-Kirloskar, CGL/ABB mounted on a common M.S. Channel fabricated base plate with following accessories- 1. Sutable size N.R Valve1 No 2. Sutable size sluice Valve 1 No 3. Sutable size Check Valve/Foot Valve1 No 4. Pressure gauge1 No 5. M.S Base Plate 1 No 6. Tyre coupling set 1 No etc all complete.
2Cost towards dismantling of old Foundation and removing the residuals out of the pumping plant and Making of New PCC foundation 4’x3’ x2.5’ size & M.S joint 4”X6”-2 nos. with supplying all mortar materials & foundation bolts 6 nos. with all labour tools and tackles loading unloading with alignment leveling and jointing as per P.W.D Specification (1:2:4) etc all complete.
3Cost towards supplying Installation & commissioning of 160 Amp, 440 VMotor Panel Board made of 2mm thick MS sheet of suitable size, dust and vermin proof consisting of following accesories : (i)160 Amp MCCB – 1 No.(Incoming feeder) (ii)100 Amp MCCB – 02Nos (outgoing feeder). (iii)32 Amp MCB -1 No. for lighting load and other utiliti load.(iv)FASD Starter suitable for the 12.5 HP Motor Pumpset – 2 Nos.(L&T make)(v)Copper Bus Bar- 4 pole 160 amp 415volt copper strip bus bar enclosed in MS sheet, etc. all complete job. (vi)LED display Voltmeter – (0-500 V) & Amp Meter(0-100A) – 2 Sets, Phase indicating lamp-6 Nos.Along with overload relay, single phase preventer proper inside wiring with suitable size of copper conductor with wall/floor mounting facility, Cubical panel box etc. all complete including transportation and fitting and mounting charges at P/Plant.
4Cost towards repairingof 63 KVA transformer with changing of HT & LT bush-3 sets each , Top-up transformer oil upto-100 ltrs, fuse wires as per required.
5Cost towards supplying and laying of 3core 95 sq.mm aluminium armoured cable from transformer to MCP
6Cost towards Chemical earthing 40feet and 80mm hole size with electrode and chemical compound etc. with watering pipe and locking arrangements including soldering, riveting, jointing G.I. flat strip 20mm X 3mm to all equipments.
7Cost towards supplying and installing 100 watt LED street light complete set all complete including labour charges. For clear water p/plant.
8Cost towards supplying Installation and commissioning of 63 KVA Servo controlled (oil cooled) automatic voltage stabilizer suitable for output voltage of 415 + 1% 3 phase, 50 Hz with copper wound transformer as mentioned below. The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%.The stabilizer should be constructed in cubical box,with bidirectional wheels for easy handling necessary monitors and user’s controls on front panel such as inducation alarm, voltmeter and selector switch for measuring input and output voltage auto manual selector switch.Raise low push buttons etc. suitable capacity termination strips and bus bars for incoming and outgoing cable should be provided .All three phases shall be independently monitored and corrected following protections and indication shall be incorporated as per IS:9815 a) Over Voltage/Under Voltage b)Single Phasing c) Cut off contactorwith electronic output sensing unit d) Suitable change over switch and earthing 100 KVA Oil cooled Servo controlled automatic voltage stabilizer (output 415 unit+ 1%) Input 280 to 450 Volt. Make: Powerline/Servokon
9Cost towards of Changeover switch TPN on load with sheet sheel enclosure Capacity Amp for by pass arrangement of servo voltage stabilizer Make C&S Havell s/L&T with all labour & tools and materials.
10Supplying and laying of 25 sq.mmx3core x1.1 Kv grade with ISI make PVC insulated and unarmored flexible copper cable from MCP to motor terminal box with suitable copper lugs etc
11PART –B RAW WATER PUMPING PLANT – INTAKE WELL AT JAMSOLA Providing all labours, tools, Tackels and technician fordisconnection and taking out20 HP VT P/Set with column pipe into intake well all complete.
12Cost towards all labour, tools, tackles and technician for opening, dismantling. repairing and overhauling of 20 HP 04 stage bow l assembly VT pump having head 58 meter. discharge- 43m3/hr speed 1460 rpm i. With S/F of S.S. pump shaft-- 01 No. ii. Top and bottom bush- 02 Nos., iii. Intermediate bushes -5 Nos.iv. Spider cut less rubber bushes- 04 Nos. v. Locks Vi. Impeller copper bush-06 Pcs. vii. G.M. impeller- 04 Nos. viii. 30mm diaS.S. line shaft-10 ft each 3 nos. ix. 30mm dia. SS.head shaft- 5 ft. each I Nos. x S. S Socket and bush-04 Nos. each. xi, Ferro collar ball rubber bush -12pc xii. Ball sleeve bush-07 Nos each all materials as per required reassembling the same at workshop refitting at site etc. all complete(Rate after deducting the scrap materials).
13Providing all labours, tools, Tackels and technician forloweringafter repairing of20 HP VT P/Set with column pipe into intake well all complete.
14Cost towards supplying all labour tools and tackles for Complete opening, dismantling. of 20 HP 440 Volt,50c/s, star delta, 3phase VT motor by supplying supperenameled copperwireandthentapping,varnishing, heating & testing on lull load and repairing of stator and rotor with including the deduction of cost of burnt copper wire approx. 18.5 kg. With changing of following bearing:- (i) Ball bearing -as per sample-01 No. and (ii) Thrust bearing as per sample (SKF Make) at raw water p/plant.
15cost towards transportation charges of above pump motor set and other linings materials from p/plant to workshop and vice versa.
16Supplying and laying of 25 sq. mm x 3 core X 1.1 KV grade with ISI mark PVC insulated and unarmoured flexible copper Cable from MCP to motor terminal box with suitable copper thumble socket etc.
17S/F of 90 watt LEDFloodlighting luminaire with pressure die cast housing and toughened glass cover, operating voltage range 100V-270V AC with structure,stand, clamp, tee, wires and switches etc. all complete including repairing of lighting arrangements inside and outside of pump house at raw water p/plant.
18Costtowardssupplying andfitting of lighteningarrester suitable for building protection with Earthing Electrode ,Earthing Compound, copper wires and earth work etc. all complete job.
19Cost towards replacement of old panel by supply installation & commissioning of new standing type floor mounting industrial panel board comprising 200 amp copper bus bar nos. in M.S Steel(14SWG) Housing. •200 amp T.P.N MCCB make L&T as incomer feeder. • 100 amp T.P.N MCCB make L&T 2 nos as outgoing feeder. • Ammeter-digital ammeter with selector switch L&T/C&S make • Voltmeter- Degital voltmeter in 3 phase RYB • Indicating lamp LED- L&T/SIEMENS/C&S make in Red, Yellow and Blue colour 1 set. • 32 amp MCB for light load and other loads of L&T /Havel’s/C&S make (2 no.) • FASD starter (Make-L&T) Suitable for above pump set. Panel should be dully painted with two coats super enameled paint of approved color one coat of red oxide primer and internally wired with suitable size of copper wire etc. all complete.
20Cost towards supplying Triple spur gear type chain pully block of 3 tonne capacity with 6m lift complete with load chain and hand chain suitable for above lift, tested to 50%over load as per IS 3832 carrying ISI mark with travelling trolley etc.
21Cost towards of Changeover switch TPN on load with sheet sheel enclosure Capacity Amp for by pass arrangement of servo voltage stabilizer Make C&S Havell s/L&T with all labour & tools and materials.
22Cost towards supplying and laying of 3core 95 sq.mm aluminium armoured cable from transformer to MCP
23Cost towards supplying Installation and commissioning of 63 KVA Servo controlled (oil cooled) automatic voltage stabilizer suitable for output voltage of 415 + 1% 3 phase, 50 Hz with copper wound transformer as mentioned below. The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%.The stabilizer should be constructed in cubical box,with bidirectional wheels for easy handling necessary monitors and user’s controls on front panel such as inducation alarm, voltmeter and selector switch for measuring input and output voltage auto manual selector switch.Raise low push buttons etc. suitable capacity termination strips and bus bars for incoming and outgoing cable should be provided .All three phases shall be independently monitored and corrected following protections and indication shall be incorporated as per IS:9815 a) Over Voltage/Under Voltage b)Single Phasing c) Cut off contactorwith electronic output sensing unit d) Suitable change over switch and earthing 100 KVA Oil cooled Servo controlled automatic voltage stabilizer (output 415 unit+ 1%) Input 280 to 450 Volt. Make: Powerline/Servokon
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail