Tender For Certain Sanctioned Works Under Age Em No. Ii., kochi-Kerala

Military Engineer Services-MES has published Tender For Certain Sanctioned Works Under Age Em No. Ii.. Submission Date for this Tender is 16-01-2023. Cushioning Supplies Tenders in kochi Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

35481214
Corrigendum : Tender For Certain Sanctioned Works Under Age Em No. Ii.
Open Tender
Indian
Kerala
kochi
16-01-2023

Tender Details

Tender For Certain Sanctioned Works Under Age Em No. Ii. - Supply And Laying Ug Cable In Trenches / Passing Through Pipes / Fixed On Walls Or Poles Cable Xlpe Insulated, Screened, Pvc Bedded, Steel Strip Or Wire Armoured Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 3.5 Core 300Sqmm With Suitable Cable Gland Including Taking Down Of Unserviceable Cable Complete All As Specified And Directed. 2 Ditto All As Per Sl Item No 1, But Aluminium Conductor Of Size 3.5 Core 240 Sqmm. 3 Ditto All As Per Sl Item No 1, But Aluminium Conductor Of Size 3.5 Core 185 Sqmm. 4 Ditto All As Per Sl Item No 1, But Aluminium Conductor Of Size 3.5 Core 120 Sqmm. 5 Ditto All As Per Sl Item No 1, But Aluminium Conductor Of Size 3.5 Core 95 Sqmm. 6 Ditto All As Per Sl Item No 1, But Aluminium Conductor Of Size 3.5 Core 70 Sqmm. 7 Ditto All As Per Sl Item No 1, But Aluminium Conductor Of Size 3.5 Core 50 Sqmm. 8 Ditto All As Per Sl Item No 1, But Aluminium Conductor Of Size 4 Core 10 Sqmm. 9 Dismantling / Taking Down Steel Tubular Pole / Rcc Pole Any Size By Cutting From Foundation By Means Mechanically Or Manually All As Specified And Directed.Note : All Led Lights Fittings On Dismantling To Be Deposit To Mes Store Yard. 10 Re Fixing The Old Tubular Poles Obtained From Sl Item No. 9, To Be Fixed At New Location As Per The Direction Of Engineer In Charge Along With All Necessary Excavation, Pcc Foundation, Returning Filling, Pole Painting And Pole Fixtures Complete All As Specified.Note: The Rate Quoted Is Deemed To Be Included The Cost Of All Excavation, Foundation And Returning & Filling And Base Painting ( Pole Numbering ) Complete All As Directed By Engineer In Charge. 11 Supply And Fixing Hot Dipped Gi Octagonal, Pu Painted ( Grey Colour ) Poles Of 6 Metres Long With 01 Metre Arm Suitable For Mounting Of 01 Nos Of Led Street Lights Complete With Base Plate And Gi Foundation Bolts And Nuts Including Excavation And Foundation Complete All As Specified And Directed By Engineer-In-Charge. Note: The Rate Quoted Is Deemed To Be Included The Cost Of All Excavation, Foundation And Returning & Filling And Base Painting ( Pole Numbering ) Complete All As Directed By Engineer In Charge. 12 Supply And Fix In Repair Led Street Light Fitting1x70 Watt New Generation Energy Saving And Environmental Friendly Long Life Led Made Of Pressure Dia Cast Aluminum Housing With High Power Led As Lighting Source And Lens Embedded Pc Cover Having Top Opening Separate Driver Compartment With Ip 66 Protection And Heat Resistant Toughened Glass With Frame Complete All As Specified And Directed . 13 Excavation In Trenches Not Exceeding 1.5 Metre Wide And Not Exceeding 1.5 Metre In Depth For Foundation Of Pole And Laying Of Underground Electric Cable In Soft / Loose Soil Complete All Specified And Directed. 14 Supply And Spread River Sand For Cushioning And Covering Of Ug Cables In Trenches Complete All Specified And Directed. ( Note : For Measurement Purpose Only Punned Thickness Shall Be Measured And Paid ) 15 Material And Labour For Common Burnt Clay Building Bricks Sub-Class B Designation Of Size 230X115x75mm Complete All As Specified And Directed 16 Returning Filling In Including Spreading, Leveling Watering And Well Ramming In Layers Not Exceeding 25Cm Complete All Specified And Directed. 17 Removing Excavated Material Not Exceeding 50 Metre And Depositing Where Directed At A Level Not Exceeding 1.5 Metre Above The Starting Point Complete All Specified And Directed. 18 Material & Labour For Gi Tubing Medium Grade ( Isi Marked ) With All Fitting / Accessories For Protection Of Cable On Pole / Wall And Under Road Crossing Including Clamps, Nut Bolt Etc All As Specified And Directed Ofsize 40Mm Dia Including Taking Down Old Unserviceable Tubing Complete All As Specified And Directed. 19 Cutting Existing Road / Hardstand Of Any Type By Using Crow Bar Chisel Up To A Depth Of 30 Cm For Laying Gi Pipe Including Making Good The Surface By Returning Filling Watering Ramming In Layers 150 Mm Thick Pcc 1:2:4 Over 150 Mm Thick Hard Core Of Broken Bricks / Stones Over Returning Filling Watering Ramming In Layers Not Exceeding 25 Cm Thick Complete All As Specified And Directed By Engineer-In-Charge. 20 Supply And Wiring With Two Run Of Pvc ( Fr ) Insulated Multistranded Copper Conductor Cable Of 1.5 Sqmm Drawing Through Pvc Conduits With Continuous Earth Wire Pvc ( Fr ) Insulated Cable Of Size 1.5 Sqmm Connected To Earth Including All Conduit Accessories Complete All As Specified And Directed. ( Note: Two Run Of Sub Main Wire, One Run Of Earth Wire And One Run Of Pvc Conduit Pipe Measured As One Unit ) . 21 Supply & Fix In Street Light Timer Control Panel, Pole / Wall Mounting Made Out Of Crca Sheet Duly Powder Coated With Locking Arrangement, Including Internal Wiring Complete With Bypass Arrangements And Comprising Of Following ( Or As Manufactures Recommendation And Design ) Including Taking Down Old Unserviceable Timer Panel Complete All As Specified And Directed. ( A ) Incomer Mcb Tpn 63 Amps, 240 / 410V- 01 Nos ( B ) Digital Timer Switch - 01 No ( C ) Contactor Ac 3 Rating, 3Ph, Of Capacity 65 Amps - 01 No ( D ) On / Off Indicating Lamp - 01 Set ( E ) Auxiliary Change Over Switch 6 A - 01 No 22 Material &Labour For Earthing Completewith Galvanized Iron Or Steel Earth Plate Electrode 60Cm X 60Cm X 6Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Metres Below Ground Level ) With Top Edge Of Earth Plate Not Less Than 1.5 Metres Below Ground Level Connected To Galvanized Iron Strip 32X6 Mm By Means Of Nuts, Bolts, Thimbles, Check Nuts, Washers Of Gi Or Steel, Including Pcc ( Concrete Chamber ) Shall Be Pcc 1:3:6 Type C-1 Using 20Mm Graded Stone Aggregate, With Fair Finish Internal Surface Of Concrete Chamber Shall Be Given 15Mm Thick Plaster In Cm 1:4, Funnel With Wire Gauge Of ( 0.68Mm ) 8 Mesh Per Liner Inch, 80 Mm Thick Rcc Pit Cover 320 Mm X 320 Mm Of Rcc 1:2:4 Type B-1 Using 20 Mm Graded Stone Aggregate Reinforced With Xpm, Jalli And Charcoal Dust And Common Salt All As Shown In Electrical Plate No 3 Of Mes Ssr Part-Iand Specified Including Provision Of Earth Wire Protected By 40Mm Dia Medium Grade Gi Pipe And Watering Funnel With 20Mm Bore Medium Grade Gi Pipe, And Including All Excavation Andearth Work & Connecting The Earthing To An Earthing Test Point Or Lt Panel Etc, And Testing On Completion, Complete All As Specified & Directed By Engineer-In-Charge. 23 Supply And Fixing And Connecting Up Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit / Pipe As Directed / Specified For Loop Earthing Etc As Required Of Galvanised Iron Strip Of Size 32 X6 Mm Complete All As Specified And Directed. Note; This Item Shall Be Measured For The Quantity Used At Site After The Length Of Strip 7.5 Metre Complete All As Specified And As Directed. 24 Material, Labour And Using Tools & Plants For Underground Pneumatic Horizontal Drilling Of Holes Under Road, Pavement, Hard Standing As Required Length At Site By Trenchless Technology Using Ultra Sound Technique With Necessary Horizontal Direction Drilling ( Hdd ) Machine Including Providing Hdpe Pipe 50 Mm Outer Dia 0.40 Mpa Including Necessary Joint Connections And Laying Lt / Ht Cable. The Contractor Shall Be Conduct Underground Scanning To Detect Existing Ht / Lt Cable Line, Sewage Line, Ofc Cable Etc To Avoid Damage. The Entry / Exist Hole Must Be Large Enough To Fit The Drilling Tool And The Operator In It So They Can Aim The Tool. The Hole Also Must Be Deep Enough That As The Tool Compacts The Ground And The Surface To Be Remain Undisturbed. The Depth Of The Starting Bore Pit Depends On The Type Of The Soil That Is Being Worked In And How Well It Compacts. The Operator Shall Aim The Tool To The Desire Exit Point And Allow It To Perform It Function Creating A Bore Hole Under The Ground Without Disturbing Surfaces. The Operator Also Should Monitor The Surface To Make Sure That, It Is Undisturbed. As The Tool Near To The Exit Point It Is Slowed Down And The Exit Pit Should Be Dug To Locate Both The Tool And The Bore. As The Tool Enters The Exit Pit The Operator Should Choose Either Dig Up The Tool To Retrieve It Or Reverses The Tool Back Into The First Bore Pit To Retrieve It Including Connected Earth Work, All As Specified And Directed By Engineer-In-Charge. 25 Supply And Fix 4 Pole Mccb 200 Amp, 50 Hz, 415 V Fixed Thermal And Fixed Magnetic Including Suitable Enclosures With Rupturing Capacity 35 Ka All As Specified And Directed By Engineer In Charge 26 Supply And Fix On Load Change Over Switch 415V With Sheet Metal Enclosures 4 Pole Of Capacity 250 Amps Including All Fittings & Fixtures Complete All As Specified And Directed. 27 Supply And Fix 75Kva Servo Stabilizer For Automatic Operation, Three Phase, Naturally Oil Cooled, Indoor Type & Designed For Input Variation Between 300 V To 480 V With Output Voltage Stabilized At 415 With Accuracy ±1% , Lcd Display To Measure Input, Output Voltage And Output Current With Over Voltage , Under Voltage Over Load And Single Phase Protection With First Filling Of Transformer Oil Including All Necessary Incoming And Outgoing Connections With Ug Cables All As Specified And As Directed. 28 Supply And Laying Un-Reinforced Precast Concrete Cable Cover Class Lv Type-I Flat Size 250Mm X 150Mm X 40Mm Complete All Specified And Directed. 29 Supply And Fixing Gi Pipe Light Grade With Necessary Fittings In Floor / Pillar / Fixed On Pole Of Size 80 Mm Dia Complete All As Specified And Directed. 30 Ditto All As Per Sl Item No 29, But Gi Pipe Of Size 50 Mm Dia. 31 Ditto All As Per Sl Item No 29, But Gi Pipe Of Size 40 Mm Dia. 32 Supply & Install, Testing And Commissioning In Replacement Of Outdoor Type Floor Mounted Lt Panel Suitable For 415 Volts, 3 Phase 4 Wire, 50 Hz Ac Supply System Conforming To Is : 8623 / 93, Floor Mounted, Factory Made, Weather And Vermin Proof, Fully Ventilated And Fabricated Out Of Angle Iron 40Mm X 40Mm X 6Mm Thick Frame Work And Crca Sheet 3Mm Thick Having Aluminum Bus Bar Of Rating 600 Amps, Three Phase And One Neutral Fixed On Insulator And Bus Bar Insulated By Coloured Heat Shrinkable Sleeves. The Size Of The Outer Shell Should Not Less Than 1000Mm X 750Mmx 500Mm, Mounted On Angle Iron Stand Made Out Of Size 40Mm X 40Mm X 6Mm Grouted Of Digital Volt Meter & Amps Meter With Cts Including And Taking Down Of Old Existing Panel Complete All As Specified And Directed:- ( A ) Bus Bar Chamber Of 3 Phase And 1 Neutral 4 Strip 415 Volts With 600 Amps Aluminium Strip-1 Set ( B ) Mccb 400 Amp 35 Ka 4 Pole- 01 No ( Incoming ) ( C ) Mccb 200 Amp 35 Ka 4 Pole- 01 No ( Outgoing ) ( D ) Mccb100 Amp 25 Ka 4 Pole - 03 Nos ( Outgoing ) ( E ) Volt Meter Digital 0-500 Volt- 01 No ( F ) Amp Meter Digital 0-300 Amp - 01 No ( G ) Indicator Lamp Yellow, Red, Blue-01 Setnote: Hinged Doors To Be Provided For The Front And Rear Sides Of Panel In Addition Bolted Arrangement In Rear Side. Ca No, Name Of Work To Be Marked On The Panel In The Factory. 33 Supply & Install, Testing And Commissioning In Replacement Of Outdoor Type Floor Mounted Lt Panel Suitable For 415 Volts, 3 Phase 4 Wire, 50 Hz Ac Supply System Conforming To Is : 8623 / 93, Floor Mounted, Factory Made, Weather And Vermin Proof, Fully Ventilated And Fabricated Out Of Angle Iron 40Mm X 40Mm X 6Mm Thick Frame Work And Crca Sheet 3Mm Thick Having Aluminum Bus Bar Of Rating 400 Amps, Three Phase And One Neutral Fixed On Insulator And Bus Bar Insulated By Coloured Heat Shrinkable Sleeves. The Size Of The Outer Shell Should Not Less Than 750Mm X750mmx 500Mm, Mounted On Angle Iron Stand Made Out Of Size 40Mm X 40Mm X 6Mm Grouted Of Digital Volt Meter & Amps Meter With Cts Including Taking Down Of Old Existing Panel Complete All As Specified And Directed:- ( A ) Bus Bar Chamber Of 3 Phase And 1 Neutral 4 Strip 415 Volts With 400 Amps Aluminium Strip-1 Set ( B ) Mccb250 Amp 35 Ka 4 Pole - 01 No ( Incoming ) ( C ) Mccb 63 Amp 25 Ka 4 Pole- 04 No ( Outgoing ) ( D ) Volt Meter Digital 0-500 Volt- 01 No ( E ) Amp Meter Digital 0-300 Amp- 01 No ( F ) Indicator Lamp Yellow, Red, Blue -01 Setnote: Hinged Doors To Be Provided For The Front And Rear Sides Of Panel In Addition Bolted Arrangement In Rear Side. Ca No, Name Of Work To Be Marked On The Panel In The Factory. 34 Supply & Install, Testing And Commissioning In Replacement Of Outdoor Type Floor Mounted Lt Panel Suitable For 415 Volts, 3 Phase 4 Wire, 50 Hz Ac Supply System Conforming To Is : 8623 / 93, Floor Mounted, Factory Made, Weather And Vermin Proof, Fully Ventilated And Fabricated Out Of Angle Iron 40Mm X 40Mm X 6Mm Thick Frame Work And Crca Sheet 3Mm Thick Having Aluminum Bus Bar Of Rating 400 Amps, Three Phase And One Neutral Fixed On Insulator And Bus Bar Insulated By Coloured Heat Shrinkable Sleeves. The Size Of The Outer Shell Should Not Less Than 1000Mm X750mmx 500Mm, Mounted On Angle Iron Stand Made Out Of Size 40Mm X 40Mm X 6Mm Grouted Of Digital Volt Meter & Amps Meter With Cts Including Taking Down Of Old Existing Panel Complete All As Specified And Directed:- ( A ) Bus Bar Chamber Of 3 Phase And 1 Neutral 4 Strip 415 Volts With 400 Amps Aluminium Strip-1 Set ( B ) Mccb 630 Amp 35 Ka 4 Pole - 01 No ( Incoming ) ( C ) Mccb 160 Amp 25 Ka 4 Pole - 03 No ( Outgoing ) ( D ) Mccb 100 Amp 25 Ka 4 Pole - 03 No ( Outgoing ) ( E ) Volt Meter Digital 0-500 Volt - 01 No ( F ) Amp Meter Digital 0-300 Amp- 01 No ( G ) Indicator Lamp Yellow, Red, Blue -01 Setnote: Hinged Doors To Be Provided For The Front And Rear Sides Of Panel In Addition Bolted Arrangement In Rear Side. Ca No, Name Of Work To Be Marked On The Panel In The Factory. 35 Material & Labour For Straight Through Joint 3.5 Core 300 Sqmm With All Accessories Complete All Specified And Directed. 36 Material & Labour For Straight Through Joint 3.5 Core 185 To 240 Sqmm With All Accessories Complete All Specified And Directed. 37 Material & Labour For Straight Through Joint 3.5 Core 95 To 120 Sqmm With All Accessories Complete All Specified And Directed. 38 Material & Labour For Straight Through Joint 3.5 Core 25 To 50 Sqmm With All Accessories Complete All Specified And Directed. 39 Taking Down Carefully Copper / Aluminium Point Wiring ( Light, Fan, Socket Or Power ) Complete Including Fixtures And Fittings Such As Switches, Ceiling Roses, Pendants Regulators, Sockets, Light Fittings Etc Removing Materials From Site And Making Good Disturbed Surface Of Walls, Floors, Ceiling Etc , All As Specified And Directed. 40 Material And Labour For Concealed Point Wiring With 1.5 Sqmm Frls Single Core Multi Stranded Copper Conductor Cable Drawn Through And Including Erw Steel Conduit Of Suitable Dia Including 1.5 Sqmm Frls Copper Conductor Cable As Earth Continuity Conductor Completefor One Light Point Controlled By One Flame Proofswitch. 41 Supply & Fix Switch Flame Proof Rotary Type With Termination Box In Lm6, 16A, Single Pole 250V Complete All As Specified Directed. 42 Supply & Fix Cimfr Certified Led Flameproof Batten Suitable For Twin T8 Tube Of 20W Including Led Lamp 20W, Recommended For Gas / Vapor Group Of Lla & Iib And Zone 1 & 2, Ip65 Protected Complete All As Directed By Engineer In Charge.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 89000.0 /-
Tender Value
INR 44.50 Lakhs /-

BOQ Items

Name of Work:CERTAIN SANCTIONED WORKS UNDER AGE EM NO. II.
Sl. No. Item Description
1Supply and Laying UG cable in trenches/passing through pipes/fixed on walls or poles cable XLPE insulated, screened, PVC bedded, steel strip or wire armoured electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 300sqmm with suitable cable gland including taking down of unserviceable cable complete all as specified and directed.
2Ditto All as per Sl Item No 1, but aluminium conductor of size 3.5 core 240 Sqmm.
3Ditto All as per Sl Item No 1, but aluminium conductor of size 3.5 core 185 Sqmm.
4Ditto All as per Sl Item No 1, but aluminium conductor of size 3.5 core 120 Sqmm.
5Ditto All as per Sl Item No 1, but aluminium conductor of size 3.5 core 95 Sqmm.
6Ditto All as per Sl Item No 1, but aluminium conductor of size 3.5 core 70 Sqmm.
7Ditto All as per Sl Item No 1, but aluminium conductor of size 3.5 core 50 Sqmm.
8Ditto All as per Sl Item No 1, but aluminium conductor of size 4 core 10 Sqmm.
9Dismantling/taking down steel tubular pole / RCC pole any size by cutting from foundation by means mechanically or manually all as specified and directed. Note : All LED lights fittings on dismantling to be deposit to MES Store yard.
10Re fixing the Old tubular poles obtained from Sl Item No. 9, to be fixed at new location as per the direction of Engineer in charge along with all necessary Excavation, PCC foundation, Returning filling, Pole Painting and Pole Fixtures complete all as specified. Note: The rate quoted is deemed to be included the cost of all excavation, foundation and returning & filling and base painting (Pole Numbering) complete all as directed by Engineer in Charge.
11Supply and Fixing hot dipped GI octagonal, PU painted (Grey Colour) poles of 6 Metres long with 01 Metre arm suitable for mounting of 01 Nos of LED street lights complete with base plate and GI foundation bolts and nuts including excavation and foundation complete all as specified and directed by Engineer-in-Charge. Note: The rate quoted is deemed to be included the cost of all excavation, foundation and returning & filling and base painting (Pole Numbering) complete all as directed by Engineer in Charge.
12Supply and fix in repair LED Street light fitting1x70 Watt new generation energy saving and environmental friendly long life LED made of pressure dia cast aluminum housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP 66 protection and heat resistant toughened glass with frame Complete all as specified and directed .
13Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth for foundation of pole and laying of underground electric cable in soft/loose soil complete all specified and directed.
14Supply and spread River Sand for cushioning and covering of UG cables in trenches complete all specified and directed. (Note : For measurement purpose only punned thickness shall be measured and paid)
15Material and labour for common burnt clay building bricks sub-class "B" designation of size 230X115X75mm complete all as specified and directed
16Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25cm complete all specified and directed.
17Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point complete all specified and directed.
18Material & Labour for GI tubing medium grade (ISI marked) with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc all as specified and directed ofsize 40mm dia including taking down old unserviceable tubing complete all as specified and directed.
19Cutting existing road/hardstand of any type by using crow bar chisel up to a depth of 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 150 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
20Supply and wiring with two run of PVC (FR) insulated multistranded copper conductor cable of 1.5 Sqmm drawing through PVC conduits with continuous earth wire PVC (FR) insulated cable of size 1.5 Sqmm connected to earth including all conduit accessories complete all as specified and directed. (Note: Two run of sub main wire, one run of earth wire and one run of PVC Conduit pipe measured as one unit).
21Supply & Fix in street light TIMER control panel, pole/wall mounting made out of CRCA sheet duly powder coated with locking arrangement, including internal wiring complete with bypass arrangements and comprising of following (or as manufactures recommendation and design) including taking down old unserviceable timer panel complete all as specified and directed. (a) Incomer MCB TPN 63 Amps, 240/410V- 01 Nos (b) Digital timer switch - 01 No (c) Contactor AC 3 rating, 3ph, of capacity 65 Amps - 01 No (d)ON/OFF indicating lamp - 01 Set (e)Auxiliary change over switch 6 A - 01 No
22Material &Labour for earthing completewith galvanized iron or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Metres below ground level) with top edge of earth plate not less than 1.5 Metres below ground level connected to galvanized iron strip 32x6 mm by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-Iand specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering funnel with 20mm bore medium grade GI pipe, and including all excavation andearth work & connecting the earthing to an earthing test point or LT panel etc, and testing on completion, complete all as specified & directed by Engineer-in-Charge.
23Supply and fixing and connecting up Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe as directed/specified for loop earthing etc as required of galvanised iron strip of size 32 x6 mm complete all as specified and directed. Note; This item shall be measured for the quantity used at site after the length of strip 7.5 Metre complete all as specified and as directed.
24Material, Labour and using Tools & plants for Underground pneumatic horizontal drilling of holes under road, pavement, hard standing as required length at site by trenchless technology using ultra sound technique with necessary horizontal direction drilling (HDD) machine including providing HDPE Pipe 50 mm outer dia 0.40 Mpa including necessary joint connections and laying LT/HT cable. The contractor shall be conduct underground scanning to detect existing HT/LT cable line, sewage line, OFC Cable etc to avoid damage. The entry/exist hole must be large enough to fit the drilling tool and the operator in it so they can aim the tool. The hole also must be deep enough that as the tool compacts the ground and the surface to be remain undisturbed. The depth of the starting bore pit depends on the type of the soil that is being worked in and how well it compacts. The operator shall aim the tool to the desire exit point and allow it to perform it function creating a bore hole under the ground without disturbing surfaces. The operator also should monitor the surface to make sure that, it is undisturbed. As the tool near to the exit point it is slowed down and the exit pit should be dug to locate both the tool and the bore. As the tool enters the exit pit the operator should choose either dig up the tool to retrieve it or reverses the tool back into the first bore pit to retrieve it including connected earth work, all as specified and directed by Engineer-in-Charge.
25Supply and fix 4 Pole MCCB 200 Amp, 50 Hz, 415 V Fixed thermal and fixed magnetic including suitable enclosures with rupturing capacity 35 KA all as specified and directed by Engineer in charge
26Supply and fix ON LOAD change over switch 415V with sheet metal enclosures 4 pole of capacity 250 Amps including all fittings & fixtures complete all as specified and directed.
27Supply and fix 75KVA Servo Stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ±1% , LCD Display to measure input, output voltage and output current with Over voltage ,under voltage over load and single phase protection with first filling of transformer oil including all necessary incoming and outgoing connections with UG cables all as specified and as directed.
28Supply and laying un-reinforced precast concrete cable cover class LV type-I flat size 250mm x 150mm x 40mm complete all specified and directed.
29Supply and fixing GI pipe light grade with necessary fittings in floor /pillar/fixed on pole of size 80 mm dia complete all as specified and directed.
30Ditto All as per Sl Item No 29, but GI pipe of size 50 mm dia.
31Ditto All as per Sl Item No 29, but GI pipe of size 40 mm dia.
32Supply & install, testing and commissioning in replacement of outdoor type floor mounted LT panel suitable for 415 volts, 3 Phase 4 wire, 50 Hz AC supply system conforming to IS : 8623/93, floor mounted, factory made, weather and vermin proof, fully ventilated and fabricated out of angle iron 40mm x 40mm x 6mm thick frame work and CRCA sheet 3mm thick having Aluminum bus bar of rating 600 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The size of the outer shell should not less than 1000mm x 750mmx 500mm,mounted on angle iron stand made out of size 40mm x 40mm x 6mm grouted of digital volt meter & Amps meter with CTs including and taking down of old existing panel complete all as specified and directed:- (a) Bus bar chamber of 3 phase and 1 neutral 4 strip 415 volts with 600 Amps aluminium strip-1 Set (b) MCCB 400 Amp 35 KA 4 pole- 01 No ( Incoming) (c) MCCB 200 Amp 35 KA 4 pole- 01 No (Outgoing) (d) MCCB100 Amp 25 KA 4 pole - 03 Nos(Outgoing) (e) Volt meter digital 0-500 volt- 01 No (f) Amp meter digital 0-300 Amp - 01 No (g) Indicator lamp Yellow, Red, Blue-01 Set Note: Hinged doors to be provided for the front and rear sides of Panel in addition bolted arrangement in rear side. CA No, Name of Work to be marked on the Panel in the factory.
33Supply & install, testing and commissioning in replacement of outdoor type floor mounted LT panel suitable for 415 volts, 3 Phase 4 wire, 50 Hz AC supply system conforming to IS : 8623/93, floor mounted, factory made, weather and vermin proof, fully ventilated and fabricated out of angle iron 40mm x 40mm x 6mm thick frame work and CRCA sheet 3mm thick having Aluminum bus bar of rating 400 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The size of the outer shell should not less than 750mm x750mmx 500mm,mounted on angle iron stand made out of size 40mm x 40mm x 6mm grouted of digital volt meter & Amps meter with CTs including taking down of old existing panel complete all as specified and directed:- (a) Bus bar chamber of 3 phase and 1 neutral 4 strip 415 volts with 400 Amps aluminium strip-1 Set (b) MCCB250 Amp 35 KA 4 pole - 01 No ( Incoming) (c) MCCB 63 Amp 25 KA 4 pole- 04 No (Outgoing) (d) Volt meter digital 0-500 volt- 01 No (e) Amp meter digital 0-300 Amp- 01 No (f) Indicator lamp Yellow, Red, Blue -01 Set Note: Hinged doors to be provided for the front and rear sides of Panel in addition bolted arrangement in rear side. CA No, Name of Work to be marked on the Panel in the factory.
34Supply & install, testing and commissioning in replacement of outdoor type floor mounted LT panel suitable for 415 volts, 3 Phase 4 wire, 50 Hz AC supply system conforming to IS : 8623/93, floor mounted, factory made, weather and vermin proof, fully ventilated and fabricated out of angle iron 40mm x 40mm x 6mm thick frame work and CRCA sheet 3mm thick having Aluminum bus bar of rating 400 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The size of the outer shell should not less than 1000mm x750mmx 500mm,mounted on angle iron stand made out of size 40mm x 40mm x 6mm grouted of digital volt meter & Amps meter with CTs including taking down of old existing panel complete all as specified and directed:- (a) Bus bar chamber of 3 phase and 1 neutral 4 strip 415 volts with 400 Amps aluminium strip-1 Set (b) MCCB 630 Amp 35 KA 4 pole - 01 No ( Incoming) (c) MCCB 160 Amp 25 KA 4 pole - 03 No (Outgoing) (d) MCCB 100 Amp 25 KA 4 pole - 03 No (Outgoing) (e) Volt meter digital 0-500 volt - 01 No (f) Amp meter digital 0-300 Amp- 01 No (g) Indicator lamp Yellow, Red, Blue -01 Set Note: Hinged doors to be provided for the front and rear sides of Panel in addition bolted arrangement in rear side. CA No, Name of Work to be marked on the Panel in the factory.
35Material & Labour for straight through joint 3.5 core 300 Sqmm with all accessories complete all specified and directed.
36Material & Labour for straight through joint 3.5 core 185 to 240 Sqmm with all accessories complete all specified and directed.
37Material & Labour for straight through joint 3.5 core 95 to 120 Sqmm with all accessories complete all specified and directed.
38Material & Labour for straight through joint 3.5 core 25 to 50 Sqmm with all accessories complete all specified and directed.
39Taking down carefully copper/aluminium point wiring (light,fan,socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants regulators, sockets, light fittings etc removing materials from site and making good disturbed surface of walls, floors, ceiling etc ,all as specified and directed.
40Material and labour for Concealed point wiring with 1.5 sqmm FRLS single core multi stranded copper conductor cable drawn through and including ERW steel conduit of suitable dia including 1.5 sqmm FRLS copper conductor cable as earth continuity conductor completefor one light point controlled by one Flame proofswitch.
41Supply & Fix Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified directed.
42Supply & Fix CIMFR certified LED flameproof batten suitable for twin T8 tube of 20W including LED lamp 20W, Recommended for gas/Vapor group of llA & IIB and Zone 1 & 2, IP65 Protected complete all as directed by Engineer in charge.
43Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail