Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 07-01-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 14-01-2023 |
| Sl. No. | Item Description |
| 1 | BOQ (REPAIR/MAINT OF COOLERS,REFRIGERATORS, SPLIT AC/WINDOW AC/PACKAGE TYPE AC IN TECHNICAL AREA ANDCONDUCER MOTOR COOLING TOWER, DESCALING OF CONDUCER OF COMPRESSOR AT AF STATION SURATGARH.)(A) REGRIGERATOR |
| 2 | S & F in replacement freezer of refrigerator of capacity upto 165 ltrincluding soldering to copper pipes etc charging of refrigerant complete as specified and directed. |
| 3 | S & F in replacement freezer of refrigerator of capacity 190 ltr to 310 ltrincluding soldering to copper pipes etc charging of refrigerant complete as specified and directed. |
| 4 | Disconnecting old defective burnt sealed compressor unit of Refrigerator 286/310 Liters capacity of any make and replacement of same with new sealed compressor unit including soldering of copper pipes, foundation rubber bushes, nuts bolts, cleaning the refrigerant system and charging of refrigerant and testing complete all as specified and directed. Make: KIRLOSKAR/ KELVINATOR/ GODREJ/WHIRLPOOL/LG. |
| 5 | All as per Srl item No-3 here-in-before but capacity 165/180 litres. |
| 6 | S & F in replacement starting relay assembly suitable for refrigerator 165/286/310 litres capacity complete all as specified and directed.Make: RANUTROL/ INDFOSS/HI TECH. |
| 7 | S & F in replacement thermostat switch with defrostingarrangement suitable for Refrigerator 286/310/165 litres capacity including knob plate and screw complete all as specified and directed. Make: INDFOSS/ RANUTROL/ HONEY WELL/HI TECH. |
| 8 | Cleaning the gas system with CTC vacuum pump and charging the refrigerant R-134A with antimoist substance and filter along with rectification of leakage in the system of 165/286/310 litres capacity refrigerator complete all as specified and directed. (B) AIR CONDITIONERS |
| 9 | S & F in replacement starting relay assembly including cost of cover and clip for air conditioner window type and split type1.5/2 ton capacity complete all as specified. Make: HITECH/RENUTROL/ INDOFOSS/ SRI RAM. |
| 10 | S & F in replacement starting capacitor 80/100 mfd suitable for 1.5/ 2 ton Air Conditioner window type /split type complete all as specified and directed. Make: SIEMENS/KELL/ SHARDA/ TESLA/ ASIAN. |
| 11 | S & F in replacement starting capacitor 120-150 mfd suitable for 2 ton capacity Air Conditioner window type/split type complete all as specified and directed. Make: SIMENS/KELL/ SHARDA/ TESLA/ ASIAN. |
| 12 | S & F in replacement running capacitor 4+6 mfd suitable for blower motor 1/1.5 ton Air Conditioner window type//split type complete all as specified and directed. Make: SIMENS/KELL/ SHARDA/ TESLA/ ASIAN. |
| 13 | All same as per item No 11 above but of capacitor 36+6 mfd |
| 14 | All same as per item No 11 above but of capacitor 40+6 mfd |
| 15 | All same as per item No 11 above but of capacitor 45+6 mfd |
| 16 | All same as per item No 11 above but of capacitor 50+6 mfd |
| 17 | Disconnecting and taking downsplit air conditioner / window type /Tower type air conditionerof 1.5/2/4 Ton capacityof any make and transporting to work shop, cleaning the gas system with CTC and charging the refrigerant after vacuumising the system including the cost of refrigerant with anti moist substance and strainer including rectification of leakage in the system and refixing in the same position complete all as specified and directed. |
| 18 | S & F in replacementthermostat switch suitable for air conditioner window type 1/1.5/2.0 ton capacity including knob plate and screw complete all as specified and directed. Make: RENUTROL/ INDOFOSS. |
| 19 | S & F in replacement new sealed rotary compressor of capacity suitable for thewindow type / split typeAC of including soldering of copper pipe, cleaning of the refrigerant system of AC and fixingrubber pads for foundation, nuts and bolts etc. and testing of AC after replacement of any make complete all as specified and directed.Note :- Contractor shall be liable to replace the provided sealed compressor under the item during free replacement guaranteeperiod of the company if compressor goes defective during guarantee period.For this purpose guarantee certificate of manufacturer duly stamped and signed shall be submitted to department along with purchase voucher. Make: Techmash/Kirloskar Copland/ Voltas/ Carrier. |
| 20 | 1.5 Ton window AC |
| 21 | 1.5 Ton split AC |
| 22 | 2.0 Ton window AC |
| 23 | 2.0 Ton split AC |
| 24 | S & F in replacementreciprocating compressor of 1.5 Ton capacityfor window type / split type AC including soldering of copper pipe, cleaning of the refrigerant system of split AC,and rubber pads for foundation, nuts and bolts etc, and testing of split AC complete all as specified and directed by Engr-in-Charge. Make: Voltas/Hitachi/Samsung |
| 25 | All as per Serial item No. 19 here in before but 2 ton capacity \"for window type / split type\" AC. |
| 26 | S & F in replacementPVC air filter of approved make suitable for 1.5/2 ton capacity window type / split type AC complete all as specified directed. |
| 27 | S & F in replacementcopper condenser of approved quality and make suitable for 1.5/2 ton capacity window type AC/split type as per sample complete all as specified and directed. |
| 28 | S & F in replacementconnection lead , 3 core PVC insulated and PVC sheathed (copper) size 70/0.0076 ISI marked complete all as specified and directed. |
| 29 | S & F in replacementblower motor 1/5 HP 380 W, single phase, 230 Volts, 50 cycles suitable for 1.5/2 Ton window type/ split typeAC complete all as specified and directed. Make: AMERICAN UNIVERSAL/LANCER/AIR MASTER/COOL MASTER. |
| 30 | M & L for Rewiring of air conditioner window type with copper wire consisting of single core PVC size 40/0.0007 with necessary sleeves, terminal clips, thimbles, insulating taps and clamps complete all as specified and directed. |
| 31 | S&F sheet metal enclosure with socket plug top single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 amps , 240 Volts, complete all as specified and directed. Make :- Legrand/L&T/Havells. |
| 32 | S & F in replacementBlower fan blade set ofaluminium/ plastic suitable for 1.5/2 ton AC complete all as specified and directed. |
| 33 | S & F in replacementFront grill for Air conditioner of any make and model as per the existing design and make as approved by Engineer-in-Charge complete all as directed. Make:SIDWAL/ USHA/ BLUE STAR/NAPOLIAN. |
| 34 | S & F in replacement remote control for split type / window typeAir conditioner of 2 Ton capacity suitable for particular Make of AC and making proper connection and testing complete all as specified and directed.Make of AC: LG/Blue Star/Carrier/Voltas |
| 35 | S & F in replacement PLC Circuit board for split type / window type/Air conditioner of 2 Ton capacity suitable for particular Make of AC and making proper connection and testing complete all as specified and directed.Make of AC: LG/Blue Star/Carrier/Voltas |
| 36 | S & F in replacement INVERTER Based PLC Circuit board for split type / window typeAir conditioner of 2 Ton capacity suitable for particular Make of AC and making proper connection and testing complete all as specified and directed.Make of AC: LG/Blue Star/Carrier/Voltas |
| 37 | M & L for servicing window and split type air conditioner /Tower air type conditioner any type/size and make upto 2 and 4 TR, including cleaning all components thoroughly, oiling/ greasing of blower motor, decarboning of all electric connections, reconnecting,cleaning and washing of filters, descaling & cleaning of conditioner fins with brush and replacement of screws/nuts, assembly andtesting complete after servicing complete all as specified and directed. |
| 38 | Taking down window type Air conditioner of capacity 1.5/2 ton and shifting from one location to other location in the AF area, fixing with all required accessories including charging of refrigerent upto desired pressure all asdirected by Engineer-in-Charge. |
| 39 | All as per Serial item No.33 above but split type Air Conditioner including charging of refrigerant etc. complete all as directed by Engineer-in-charge. |
| 40 | Supply and fixing in replacement of cooling copper coil of any size as suitable for air conditioner of any type complete all as specified and directed |
| 41 | M&L for sub-main wiring with two single core 6 sq mm FR PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonary including 25 mm dia non-metallic PVC conduit fixed in wall including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge.Note:- Two run of 6 sqmm one run of 4 sqmm cable one run of conduit shall be measured as one length.Make : Polycab/Havells/Plaza HPL/Gloster |
| 42 | Repair /replacement /maintenance of voltage stablizer for automatic operation single phase air cooled indoor type input variation between 170 V to 280 V with output voltage stablized at 230 V wall mounting of capacity 3 KVA/ 4 KVA/5 KVA, complete all as specified and directed. |
| 43 | Taking down carefully aluminum /copper point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surface of wall/floor, etc. complete all as specified and as directed..Note :- Temporary power supply shall be provided by contractor. |
| 44 | M&L for point wiring (concealed) in and including rigid non metallic PVC conduit, medium grade, ISI marked,19/20 mm dia, with 4 sqmm FR PVC insulated & unsheathed, stranded copper conductor cable, single core, 1100 volts grade, ISI marked with cast iron pressed steel terminal boxes of suitable depth and 1.6 mm thick for mounting switches, sockets with 3 mm thick Bakelite laminated sheet cover with brass screws, cup washer and including FR PVC insulated & unsheathed stranded copper conductor of 2.5 sqmm ISI marked as continuous earth wire complete for socket outlet 3 pin 15 Amps on independent board, complete all as specified and directed.(C) CENTRAL AC PLANT |
| 45 | Cleaning and washing of microfilters of AHU ofgiven belowcapacity up to the satisfaction of Engineer In Charge including any other minor repair needed in AHU.Any broken filter shall be replaced with new one and same shall be paid under respective item. |
| 46 | Up to 10000 CFM |
| 47 | 10000 CFM to 20000 CFM |
| 48 | Descaling of condensor with the help of descaling chemical and nylon brush and cleaning of AHU filters blowers etc complete for the satisfaction of the Engr in charge of the following capacity of the AC plants of any make, complete all as specified & directed by Engineer-in-Charge:- |
| 49 | Upto to 15TR capacity |
| 50 | 15TR to 30TR capacity |
| 51 | 30TR to 50TR capacity |
| 52 | 50TR to 75TR capacity |
| 53 | Cleaning of cooling tower with one or two as per existing size, water basin and makeup tank with the help ofchemical and nylon brush,removing and refixing of PVC finches after washing,cleaning of condenser pipe line( in letand out let) including painting of out side of cooling tower with inlet and out let pipe line with one coat synthetic enamel paint of colour approved by engr in charge and inside painting of water tank of cooling tower used water proof black japan paint one coat including changing of unserviceable PVC guard water distributor, PVC pipe, etc complete for the satisfaction of the Engr-in-charge of the following capacity of the AC plantsat diffrent locations complete all as specified and as directed. |
| 54 | Upto 30TR |
| 55 | 30TR to 60 TR |
| 56 | More than 60TR |
| 57 | Removing old unserviceable port Y strainer and Material and labour for Y type strainer 150mm size of both end flanged including supply & welding flange of size 150 mm two nos, complete all as specified & directed by Engineer-in-Charge Make:Adeco/Zoloto or equivalent. |
| 58 | Removing old unserviceable port Y strainer and Material and labour for Y type strainer 100mm size of both end flanged including supply & welding flange of size 100 mm two nos, complete all as specified & directed by Engineer-in-Charge Make:Adeco/Zoloto or equivalent. |
| 59 | Removing old unserviceable port Y strainer and Materia and labour for Y type strainer 80mm size of both end flanged including supply & welding flange of size 80 mm two nos, complete all as specified & directed by Engineer-in-Charge Make:Adeco/Zoloto or equivalent. |
| 60 | Removing old unserviceable port Y strainer and Material and labour for Y type strainer 65mm size of both end flanged including supply & welding flange of size 65 mm two nos, complete all as specified & directed by Engineer-in-Charge Make:Adeco/Zoloto or equivalent. |
| 61 | Removing old unserviceable port Y strainer and Material and labour for Y type strainer 50mm size of both end flanged including supply & welding flange of size 50 mm two nos, complete all as specified & directed by Engineer-in-Charge Make:Adeco/Zoloto or equivalent. |
| 62 | Taking down old unserviceable butter fly valve and material and labour for butter fly valve with rubber packing of size 150 mm, complete all as specified & directed by Engineer-in-ChargeMake:Adeco/Zoloto or equivalent. |
| 63 | Taking down old unserviceable butter fly valve and material and labour for butter fly valve with rubber packing of size 100 mm, complete all as specified & directed by Engineer-in-ChargeMake:Adeco/Zoloto or equivalent. |
| 64 | Taking down old unserviceable butter fly valve and material and labour for butter fly valve with rubber packing of size 80 mm, complete all as specified & directed by Engineer-in-ChargeMake:Adeco/Zoloto or equivalent. |
| 65 | Taking down old unserviceable butter fly valve and material and labour for butter fly valve with rubber packing of size 65 mm, complete all as specified & directed by Engineer-in-ChargeMake:Adeco/Zoloto or equivalent. |
| 66 | Taking down old unserviceable butter fly valve and material and labour for butter fly valve with rubber packing of size 50 mm, complete all as specified & directed by Engineer-in-ChargeMake:Adeco/Zoloto or equivalent. |
| 67 | Taking down old unserviceable butter fly valve and material and labour for butter fly valve with rubber packing of size 40 mm, complete all as specified & directed by Engineer-in-ChargeMake:Adeco/Zoloto or equivalent. |
| 68 | Taking down old unserviceable butter fly valve and material and labour for butter fly valve with rubber packing of size 32 mm, complete all as specified & directed by Engineer-in-ChargeMake:Adeco/Zoloto or equivalent. |
| 69 | Taking down old unserviceable chiller / condensor mono block pump set of any size/capacity and supply and fixing commissioning and testing of condensor/chiller monoblock pump set of capacity 5HP (80mmx65mm) 23 mtr head,10 LPs, complete all as specified & directed by Engineer-in-ChargeMake Kirloskar model No.KDS/525 or Crompton or equivalent. |
| 70 | Taking down old unserviceable chiller / condensor mono block pump set of any size/capacity and supply and fixing commissioning and testing of condensor/chiller monoblock pump set of capacity 7.5KW/10HP (80mmx65mm) 25 mtr head,14 LPs, complete all as specified & directed by Engineer-in-Charge.Make Kirloskar model No.KDS-1040++ or Crompton or equivalent. |
| 71 | Taking down old unserviceable pressure guage supply and fixing testing of pressure guage of 0 to 100 PSI complete all as specified and directed. |
| 72 | Providing and fixing in position the mercury-in- glass industrial type thermometers complete with fitttings as directed. |
| 73 | Taking down old unserviceable/ broken pulley of AHU of any size and supply,fixing, testing and commissioning of new pulley suitable for any capacity AHU complete all as specified and as directed by Engineer in charge.Note : Any machining work needed at shaft of motor is also included in quoted rate. |
| 74 | Taking down old unserviceable AHU microfilters of any size and supply,fixing, testing and commissioning of new microfilters of existing size for any capacity AHUs complete all as specified and as directed by Engineer in charge. |
| 75 | Taking down old unserviceable AHU microfilters of any size and supply,fixing, testing and commissioning of new microfilters of existing size for complete AHU of capacity up to 10000 CFM complete all as specified and as directed by Engineer in charge. |
| 76 | Taking down old unserviceable AHU microfilters of any size and supply,fixing, testing and commissioning of new microfilters of existing size for complete AHU of capacity 10000 to 20000 CFM complete all as specified and as directed by Engineer in charge. |
| 77 | Taking down old unserviceable motor protector relay of any size and supply,fixing, testing and commissioning of new \"INT 69 DMY Motor Protector Relay\", Part No 22 A 407 S21 of Kriwan Make or equivalent suitable for 78.8 TR Central AC Plant unit of Bluestar Make operation complete all as specified and as directed by Engineer in charge.Note: Any other minor item required to make the unit functional shall be included in the quoted rate. |
| 78 | Taking down old unserviceable/ torn out canvas cloth of any size and supply,fixing and testing of new canvas cloth for making connection between AHU and Duct suitable for any capacity AHU complete all as specified and as directed by Engineer in charge. |
| 79 | Taking down old unserviceable motor pump coupling set of any size and supply,fixing, testing and commissioning of new motor pump coupling complete set along with rubber star coupling suitable for any capacity centrifugal pump set complete all as specified and as directed by Engineer in charge. |
| 80 | Taking down old unserviceable motor pump coupling\"s star rubber of any size and supply,fixing, testing and commissioning of new motor pump coupling\"s star rubber set suitable for any capacity centrifugal pump set complete all as specified and as directed by Engineer in charge. |
| 81 | Preparation of old painted surface of MS pipes and painting with one coat of synthetic enamel paint, as per colour code given by the deptt , complete all as specified and as directed by Engineer-in-Charge.(Note :- The rates includes for writing and marking description of pipes with white enamel paint) |
| 82 | Supply, fixing,testing and commissioning of 2 HP single phase open well submersible pump with approved make starter along with necessary cable( approximate 20 RM) and necessary medium grade GI pipe line( approximate 10 RM) connection of approved make as per the site requirement and as directed by Engineer In Charge. Make : Kirloskar KOSi-245 or equivalent. |
| 83 | Taking down old unserviceable electric strip heater and Supply, installation, testing and commissioning of electric strip heater of 3 KW complete all as specified and as directed.Make :Dass pass/Standard/Crown |
| 84 | Taking down old rusted unserviceable MS/GI tray of any size and supply,fixing, fabricating, testing and commissioning of new GI tray of approximate size 50 Inches X 13 Inches and sides raised by 1 inch made of minimum 18 gauge GI with black bitumen coatingsuitable for any capacity FCU water drain purpose complete all as specified and as directed by Engineer in charge.Note : Size of tray is tentative and may vary as per site requirement.Any minor item needed like PVC pipes for water draining etc shall be included in quoted rate. |
| 85 | Taking down old unserviceable Fan coil unit of any size and supply,fixing, testing and commissioning of new Fan Coil Unit of 1200 CFM having single phase motor with double shaft complete all as specified and as directed by Engineer in charge. |
| 86 | Taking down old unserviceable Fan coil unit of any size and supply,fixing, testing and commissioning of new Fan Coil Unit of 1000 CFM having single phase motor with double shaft complete all as specified and as directed by Engineer in charge. |
| 87 | Labour only for identification of breakdown of any type of AC Plants of any capacity and rectify the same with proper record mentioning time date and nature of defect duly signed by JE E/M and AGE E/MNotes:- (a) Spares required for major repair will be paid separately. (b) Contractor will produce the register at the time of payment. |
| 88 | Taking down old unserviceable cooling tower motor\"s cover/ umbrella of any size and supply,fixing and testing of new mettalic cover of cooling tower motor for protection of motor from rain for any capacity cooling tower all as specified and as directed by Engineer in charge. |
| 89 | Removing old unserviceable thermal insulation and Supply and insulation of thermal insulation on ducts/chiller pipe line exposed to sun light using closed cell O nitrile rubber elastometric insulation of density 40-55 kg/m3, minimum thickness 20mm, thermal conductivity of 0.037 W/mk at 20 degree celcius mean temp and MZ 7000(without any additional vapour barrier)and with chemical threatted factory laminated Woven fibre glass cloth with 200+/- 20 gsm to be applied on ducts manufactured recommended rubber based adhesive in a blend of solvents complete as per specificaions. |
| 90 | Supply, installation, testing and commissioning of acoustic insulation of pipe line with glass wool having thickness 25 mm resin bonded fibre glass, of 48 kg/cum density, covered with and 28 G Aluminium perforated sheet complete all as specified. |
| 91 | Taking down old unserviceable cooling tower of any capacity and Supply installation testing and commissioning of FRP cooling tower of 90 TR suitable heat rejection capacity with FRP water basin PVC fills water distribution arrangement with self rotating sprinkleres statically and dynamically balanced axile flow fan direct driven,TEFC motor,suction screen,over flow and drain connections suitable GI inspection ladder,steel supporting structure,antivibration mounting etc.complete as per manufactures design/specifications for 90 TR capacity of Plant of water in is 35degree celcius and water out is 29.4degree celcius complete all as specified and as directed. |
| 92 | Taking down old unservicable MCCB of any capacity and Supply, Fixing, testing of MCCB 3 Pole, 415 V, Adjustable type, 100Amps with breaking capacity 16 KA complete all as specified and as directed. |
| 93 | Taking down old unservicable MCCB of any capacity and Supply, Fixing, testing of MCCB 3 Pole, 415 V, Adjustable type, 160Amps with breaking capacity 36 KA complete all as specified and as directed. |
| 94 | Taking down old unservicable MCCB of any capacity and Supply, Fixing, testing of MCCB 3 Pole, 415 V, Adjustable type, 250Amps with breaking capacity 36 KA complete all as specified and as directed. |
| 95 | Taking down old unservicable MCCB of any capacity and Supply, Fixing, testing of MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA complete all as specified and as directed.. |
| 96 | Taking down old unserviceable Air vent valve 15/20 mm and supply and fixing testing of air vent valve 15 mm, complete all as specified & directed by Engineer-in-Charge |
| 97 | Supply and fixing power contactor 45 Amps, including taking down old unserviceable power contactor, complete all as specified & directed by Engineer-in-Charge Make :Siemens ,Havells, L&T . |
| 98 | Supply and fixing power contactor 32 Amps, including taking down old unserviceable power contactor, complete all as specified & directed by Engineer-in-ChargeMake :Siemens ,Havells, L&T . |
| 99 | Supply and fixing power contactor 25 Amps,including taking down old unserviceable power contactor, complete all as specified & directed by Engineer-in-ChargeMake :Siemens ,Havells, L&T . |
| 100 | Supply and fixing power contactor MNX-18 Amps,including taking down old unserviceable power contactor,complete all as specified & directed by Engineer-in-ChargeMake :Siemens ,Havells, L&T . |
| 101 | Supply and fixing over load relay 9 to 15 Amps,including taking down old unserviceable relay, complete all as specified & directed by Engineer-in-ChargeMake :Model No.ML 2 of L&T or equivalent. |
| 102 | Supply and fixing over load relay 6 to 10 Amp,including taking down old unserviceable relay, complete all as specified & directed by Engineer-in-ChargeMake :Model No.ML 2 of L&T or equivalent. |
| 103 | M&L for replacement of control wiring of AHU and AC plant panel with suitable copper conductor with all necessary connections all as specified and directed by Engr-in-Charge. |
| 104 | Disconnecting, dismantling the defective three phase induction motor 415 Volts of fan motors 50 HZ of any RPM for following capacities and re-winding with super enamelled copper wire of best quality of existing size/gauge and weight inciuding raplacement of insulation material,varnish bearing connection plate and all other petty items required to make the motor functional and reassembling the motor including installation commissioning and testing on full load, complete all as specified & directed by Engineer-in-Charge |
| 105 | 10 HP |
| 106 | 7.5HP |
| 107 | 5 HP |
| 108 | 3HP |
| 109 | Disconnecting dismantling of cetrifugal monoblock pump set of following capacities of pump any RPM and dismantiling defective parts such as impeller nut,gland,impeller key,gland packing water deflector bush bearings sleeve,gaskets,volute stud and nuts suction and delivery flange and stud and nuts and all other petty items required to make the pumpset functional and reassembling the pumpset including installation commissioning and testing, complete all as specified & directed by Engineer-in-Charge |
| 110 | 10 HP |
| 111 | 5 HP |
| 112 | 3HP |
| 113 | Material and labour for fanbeltfor usingof AHU Motor, Package unit, any size any plant of compressor complete all as specified and as directed. |
| 114 | Supply, Laying and testing MS pipes (ERW steel) heavy grade including cutting, bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 150 mm as per IS 1239 (2004)fixed in replacement of existing unserviceable pipes complete by cutting road and footpath and making surface good as per existing complete all as specified and directed. |
| 115 | Supply, Laying and testing MS pipes (ERW steel) heavy gradeincluding cutting, bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 100 mm as per IS 1239 (2004) fixed in replacement of existingunserviceable pipes complete by cutting road and footpath and making surface good asper existing complete all as specified and directed. |
| 116 | Supply, Laying and testing MS pipes (ERW steel)heavy grade including cutting, bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 80 mm as per IS 1239 (2004)fixed in replacement of existing unserviceable pipes complete by cutting road and footpath and making surface good as per existing,complete all as specified and directed. |
| 117 | Supply, Laying and testing MS pipes (ERW steel) heavy grade including cutting,bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 65 mm as per IS1239 (2004) fixed in replacement of existing unserviceable pipes complete by cutting road and footpath and making surface good as per existing complete all as specified and directed. |
| 118 | Supply, Laying and testing MS pipes (ERW steel)heavy grade including cutting,bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 50 mm as per IS 1239 (2004) fixed in replacement of existing unserviceable pipes complete by cutting road and footpath and making surface good as per existing complete all as specified and directed. |
| 119 | Supply, Laying and testing MS pipes (ERW steel)heavy gradeincluding cutting, bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 40 mm as per IS 1239 (2004)fixed in replacement of existing unserviceable pipes complete by cutting road and footpath and making surface good as per existing complete all as specified and directed. |
| 120 | Supply, Laying and testing MS pipes (ERW steel) heavy gradeincluding cutting, bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 32 mm as per IS 1239 (2004)fixed in replacement of existing unserviceable pipes complete by cutting road and footpath and making surface good as per existing complete all as specified and directed. |
| 121 | Supply, Laying and testing MS pipes (ERW steel)heavy grade including cutting, bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 25 mm as per IS1239 (2004) fixed in replacement of existing unserviceable pipes complete by cutting road and footpath and making surface good as per existing,complete all as specified and directed. |
| 122 | S&F Rotational moulded polyethylenewater storage tank tripple layered 10000 litres capacity (cylindrical vertical with closed top) hoistedand fixed in position including taking down old water storage tank, complete all as specified and directed.Make:- Sintex/Polycon/Fusion |
| 123 | S&F Rotational moulded polyethylene water storage tank tripple layered2000 litres capacity (cylindrical vertical with closed top) hoisted with thread tank cover and fixed in positionincluding taking down old water storage tank, complete all as specified and directed.Make:- Sintex/Polycon/FusionNote :- For item 101 & 102 - Quoted Rate shall including for making suitable connection of GI Pipe. |
| 124 | Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 17 of tender documents. |