Tender For Provision Of Work Services And Other Br Work For External Walls Of Bldg No.63 At Cgdhq 15 Okha Under Ge I Cg Porbandar, Porbandar-Gujarat

Military Engineer Services-MES has published Tender For Provision Of Work Services And Other Br Work For External Walls Of Bldg No.63 At Cgdhq 15 Okha Under Ge I Cg Porbandar. Submission Date for this Tender is 02-01-2023. Wrenches and Drivers Tenders in Porbandar Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

35443621
Tender For Provision Of Work Services And Other Br Work For External Walls Of Bldg No.63 At Cgdhq 15 Okha Under Ge I Cg Porbandar
Open Tender
Indian
Gujarat
Porbandar
02-01-2023

Tender Details

Tender For Provision Of Work Services And Other Br Work For External Walls Of Bldg No.63 At Cgdhq 15 Okha Under Ge I Cg Porbandar - Material And Labour For Rolled Sections As In Framing For Cladding, Glazing And The Like Fixed With Angle Cleats And Connecting Plates, Etc. 3 M&L For Costomizing , Fabricatingglow Sign Board Consisting Of Letters Of Size300x500x50mm, 29 Nos ( Chankya Block Operational Wing ) ( English / Hindi / Gujarati ) In Time Roman Style Consisting Of 2 Mm Thick Aluminium Sheetwith Front Face Covered With Retro Reflective Thermo Acrylic Sheet And Providing Led Lights With Driver In Each Letter And Logoand Fixingover Acp Sheets At Any Height As To Maintain Min 5Mm Gap In Between Letter , Including Wiring, Control Panels, Completeall As Specified And As Directed By Engineer-In-Charge. 4 S&F Aluminium Composite Panels In All Colours Of Approved Brand For External / Internal Wall Cladding At All Heights And Elevations Including Necessary Aluminium Composite Panel Consist Of 3Mm Thermoplastic Core Of Anti Oxidant Ldpe Sandwitched Between Two Sking Of 0.5Mm Thick Alloy Sheet Making A Total Sheet Thickness Of 4Mm. The Surface Shall Be Finished With Pdvf Base Coating On The Top Side And Service Coating On The Reverse Side Shall Be With A Polymer Paint. The System To Be Fixed To The Brick / Stone / Masonry / Rcc Walls / Framed Structure With Necessaary Clamps, Bracket And Anchor Fasteners Fixed Over And Including Base Frame Fabricated With Aluminium Square Pipe Of Size 40Mm X 20Mm With 1Mm Thickness In 600Mm X 600Mm Size Of Grid Including Stainless Steel Screws, Nut Bolts, Washers, Cleats, Weather Silicon Sealent For Groove Filling, Backer Rods Etc, Complete All As Per Manufacturer Instrsuction And All As Specified And As Directed By Engr-In-Charge. All Clamps And Brackets Shall Be Hot Deep Galvanised Minimum 20 Microns, ( Items Include Cost Of Aluminium Frame, Acp Panels, Cramps, Weather Sealant, Gasket, Foam, Fixtures, Scaffolding, All Machineries And Any Fastening Strips, Nuts, Bolts, Rivets, Washers, Etc Complete ) .Make Of Acp : Alupex / Aludecor / Alstrong / Tm 5 M&L For Providing And Fixing 10 Mm Thick Plaster Of Paris Including For Sunk Or Raised Moulding Ceiling ( Gypsum Anhydrous ) To Flat Surface, Gi Frame Work For Seamless Ceiling Comprising Of Gi Perimeter Channel 0.55Mm Thick With Two Unequal Flanges Of 20Mm And 30 Mm And Web Of 27Mm Fixed To Surrounding Wall Using Nylon Sleeves And Screws At 450Mm Centre To Centre / Intermediate Channel 0.9Mm Thick Having Two Equal Flanges Of 15Mm And Web Of 45Mm Suspended From Soffit At Approx 900Mm Centre To Centre With Gi Cleat And Steel Expansion Fastenerswith And Including Ceiling Section ( Not Exc 1.2Mm Length ) Of 0.55Mm Thickness Having Kurled Web Of 50 Mm And Flange Of 26Mm Each With Lips Of 10.5Mm Fixed To The Intermediate Channel With Connecting Clips Across The Intermediate Channel At 457Mm Centre To Centre And Applying Two Coats Of Oil Bound Distemper Including Taking Down Existing Complete All As Specified And As Directed 6 M&L Double Charged Vitrified Ceramic Tiles With Light Shade 10 Mm Thich Square Or Rectangular Polished Area Of Each Tilles Exceeding 0.42 Sqm But Not Exceeding 1.00 Sqm In Floors Etcset And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Colour Of Tiles Including 15 Mm Thick Scread Bedding In Cement Mortar 1:4 , All As Specified 7 Demolition Of Concrete In Ground Floors And Pavings N Exc 15 Cm Thickness ( Below Or Above Ground Level ) 8 S&F 5Mm Thick Pvc Sheet Fillet Of Width 35Mm For Wall Paneling Inclusive Of Fixing On To Wall To Make Pvc Frame As Per Specification And Drawing 9 S&F Solid Pvc Wall Lining Consisting Of 5Mm Thick Plain Colour Pvc Sheet Inclusive Of Solvent Cement And Fixing At Site On Pvc Frame As Per Specifications And Drawing 10 M&L Rcc ( Nominal Mix ) Type B-1, 1: 2 : 4 ( Using 20Mm Graded Aggregates ) As In Fins, Fascias, Louvres, Parapets, And Railings Exc. 60Cm In Height, Newels, Balustrade, Andthe Like. 11 Formwork To Faces Of Walls, Retaining Walls, Abutments, Parapets And Staircase Railingsand Similar Work Including Attached Pillasters, Buttresses, Etc Rough Finished Vertical Or To Batter 12 Mild Steel Bars 10Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips 13 M & Lrendering 10 Mm Thick In Cm 1:4Onfair Facesof Roof Concretework Finished Even & Smooth Without Using Extra Cement. 14 Hand Rails, Half Round Or Other Steel Section Or Core For Wooden Hand-Rail Straight Portion, Drilled And Countersunk For Balusters Running Bars, For Doors, Balusters, Nosing To Steps Including Embeding In Concrete And Screwing Etc. Wind Ties For Roof Including Securing Boltsposts And Struts In Fencing Including Cutting Tops To Shape As Directed, Drilling Holes, Notching For Wire, Etc.; Flat Iron Fillets ( For Securing Wire Mesh Etc. ) Including All Necessarydrilling, Bolting Or Riveting, Etc., And Similar Work Conforming To Fe-290 Gde E-265 15 M&L For Preparation Of Newly Plastered / Untreated Surfaces And Applying Two Or More Coats Of 100% Premium Acrylic Emulusion Paint Having Voc 50Gm / Litre And Uv Resistance As Per Is 15489 : 2004, Alkali And Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade ( Company Depot Tinted ) With Silicon Aditives @ 1.43 Litre / 10Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre / 10 Sqm Ovre New Surfaces. 16 M&L For Preparation Of New Steel Surfaces Of Any Description And Applying Two Coats Of Epoxy Based Paint Over A Coat Of Red Oxide, Over 10Cm In Width Or Girth, Not Otherwise Described 17 Dismantling Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided For 18 Refixing Of Hand Rails Obtain From Item No 16 19 S &F Mcb ( Db ) Spn 6 Way Double Door 415 V Made Of Sheet Metal Enclosure For McbS As Incomming And Spn / Sp Mcb As Outgoing As Spoecifiedmake: Hager / Legrand / Schneider 20 M&L For Mcb Spn Pole 240 Volt C Curve 10 Ka, Isi Marked As Per Is / Iec 60898-1 2002Of 16 / 32Amps Capacity Ip 20Complete All As Specified And Directed 21 M&L For Mcb Sp 240 Volt C Curve 10 Ka, Isi Marked As Per Is / Iec 60898-1 2002Of 6 / 32Amps Capacity Ip 20Complete All As Specified And Directed 22 Supply And Fixreccessed Type Downlighter Led Fitting 18 / 20 Watt , 5700K, Cool White, With Driver Complete All As Specified And Directed Including Connecting Cable From Ceiling Rose To Terminal Block Of Luminaire All As Specified.Make : Philips ( Dn296b Led20s-6500 Psu Wh ) / Wipro / Crompton 23 Supply And Fixreccessed Type Downlighter Led Fitting 12 Watt , 3000K, Warm White, With Driver Complete All As Specified And Directed Including Connecting Cable From Ceiling Rose To Terminal Block Of Luminaire All As Specified.Make : Philips ( 12W Sky Cob Tilt Led Spotlight ( Ww ) ) / Wipro / Osram 24 M & L Submain Wiring With Two Runs Of 1.5 Sqmmsingle Core Pvc Insulated But Unsheathed Multi Stranded Copper Conductor Frls 1100 Volts Grade Cable Drawn Through And Including Pvc Conduit And One Run Of 1.5 Sqmm Single Core Pvc Insulated But Unsheathed Multistranded Copper Conductor 1100 Volts Grade Cable As Earth Conductor In Concealed / Surface Casing Caping But Shall Be Increased As Per Actual Site Requirement In Accordance With Clause No. 19.125 Of Ssr Part-I ) Isi Marked With Wallthickness Not Less Than 1.8Mm Including Conduit Accessories Like Bends, Tees, Junction Boxes Etc Fixed Concealed / Recessed In Wall Or Ceiling Etc Complete Complete As Specified. 25 M & L Submain Wiring With Two Runs Of 4 Sqmmsingle Core Pvc Insulated But Unsheathed Multi Stranded Copper Conductor Frls 1100 Volts Grade Cable Drawn Through And Including Pvc Conduit / Pvc Casing Caping And One Run Of 2.5 Sqmm Single Core Pvc Insulated But Unsheathed Multistranded Copper Conductor 1100 Volts Grade Cable As Earth Conductor In Concealed / Surface Casing Caping But Shall Be Increased As Per Actual Site Requirement In Accordance With Clause No. 19.125 Of Ssr Part-I ) Isi Marked With Wallthickness Not Less Than 1.8Mm Including Conduit Accessories Like Bends, Tees, Junction Boxes Etc Fixed Concealed / Recessed In Wall Or Ceiling Etc Complete Complete As Specified. 26 Taking Down Old / Existing Out Door Unit And M&L For Detecting The Cause Of Leakage In Any Type / Capacity Of 1.5 Tonne / 2.0 Ac And Ensuring The Complete System Leak Proof And Charging Of Refrigerant Gas With Appropriate Quantity And Re Install On Roof Includingproviding Appropriate Water Piping And As Directed By Eic Including Testing For Smooth Functioning Complete All As Specified And As Directed. 27 M&L For Refrigerant Tubing For Suction / Discharge / Liquid Tube Copper Pipe Of Size Including 3 / 8 & 5 / 8 Inches Od With Insulation Packing All As Per Site Requirement And As Directed By Engr-In-Charge

Key Value

Document Fees
INR 500 /-
EMD
INR 84000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: PROVN OF WORK SERVICE & OTHER B/R WORK FOR EXTERNAL WALLS OF BLDG NO.63 AT CGDHQ-15 OKHA UNDER GE I CG PORBANDAR
Sl. No. Item Description
1SCHEDULE "A"
2Material and labour for Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc.
3M&L for costomizing , fabricatingglow sign board consisting of letters of size300X500X50mm, 29 Nos (CHANKYA BLOCK "OPERATIONAL WING") (English/Hindi/ Gujarati) in Time Roman style consisting of 2 mm thick aluminium sheetwith front face covered with retro reflective thermo acrylic sheet and providing LED lights with driver in each letter and logoand fixingover ACP sheets at any height as to maintain min 5mm gap in between letter , including wiring, control panels,completeall as specified and as directed by Engineer-in-Charge.
4S&F Aluminium Composite panels in all colours of approved brand for external / internal wall cladding at all heights and elevations including necessary aluminium composite panel consist of 3mm thermoplastic core of anti oxidant LDPE sandwitched between two sking of 0.5mm thick alloy sheet making a total sheet thickness of 4mm. The surface shall be finished with PDVF base coating on the top side and service coating on the reverse side shall be with a polymer paint. The system to be fixed to the brick/ stone/ masonry/RCC walls/framed structure with necessaary clamps, bracket and anchor fasteners fixed over and including base frame fabricated with aluminium square pipe of size 40mm x 20mm with 1mm thickness in 600mm x 600mm size of grid including stainless steel screws, nut bolts, washers, cleats, weather silicon sealent for groove filling, backer rods etc, complete all as per manufacturer instrsuction and all as specified and as directed by Engr-in-Charge. All clamps and brackets shall be hot deep galvanised minimum 20 microns, (items include cost of aluminium frame, ACP Panels, Cramps, weather sealant, gasket, foam, fixtures, scaffolding, all machineries and any fastening strips, nuts, bolts, rivets, washers, etc complete).Make of ACP : ALUPEX/ALUDECOR/ALSTRONG/TM
5M&L for providing and fixing 10 mm thick plaster of paris including for sunk or raised moulding ceiling (Gypsum anhydrous) to flat surface, GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20mm and 30 mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre /intermediate channel 0.9mm thick having two equal flanges of 15mm and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fastenerswith and including ceiling section (not exc 1.2mm length) of 0.55mm thickness having kurled web of 50 mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre and applying two coats of oil bound distemper including taking down existing complete all as specified and as directed
6M&L double charged vitrified ceramic tiles with light shade 10 mm thich Square or Rectangular polished area of each tilles exceeding 0.42 sqm but not exceeding 1.00 sqm in floors etcset and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles including 15 mm thick scread bedding in cement mortar 1:4 , all as specified
7Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
8S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing
9S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing
10M&L RCC (Nominal Mix) Type B-1, 1: 2 : 4 (using 20mm graded aggregates) as in Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like.
11Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc rough finished vertical or to batter
12Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
13M & LRendering 10 mm thick in CM 1:4onfair facesof roof concretework finished even & smooth without using extra cement.
14Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing boltsposts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-265
15M&L for preparation of newly plastered/ untreated surfaces and applying two or more coats of 100% Premium Acrylic emulusion paint having VOC 50gm/litre and UV resistance as per IS 15489 : 2004, Alkali and Fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with Silicon Aditives @ 1.43 litre/10sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm ovre new surfaces.
16M&L for preparation of new steel Surfaces of any description and applying two coats of epoxy based paint over a coat of red oxide, over 10cm in width or girth,not otherwise described
17Dismantling wrought iron or mild steel work of any description not otherwise provided for
18Refixing of hand rails obtain from item No 16
19S &F MCB (DB) SPN 6 way double door 415 V made of sheet metal enclosure for MCB"s as incomming and SPN/SP MCB as outgoing as spoecified Make: Hager / Legrand/ schneider
20M&L for MCB SPN pole 240 volt C curve 10 KA,ISI marked as per IS/IEC 60898-1 2002of 16/32Amps capacity IP 20complete all as specified and directed
21M&L for MCB SP 240 volt C curve 10 KA,ISI marked as per IS/IEC 60898-1 2002of 6/32Amps capacity IP 20complete all as specified and directed
22Supply and fixreccessed type downlighter LED fitting 18/20 Watt ,5700K, cool white, with driver complete all as specified and directed including connecting cable from ceiling rose to terminal block of luminaire all as specified.Make : Philips(DN296B LED20S-6500 PSU WH)/Wipro/Crompton
23Supply and fixreccessed type downlighter LED fitting 12 Watt ,3000K, Warm white, with driver complete all as specified and directed including connecting cable from ceiling rose to terminal block of luminaire all as specified.Make : Philips(12W Sky COB Tilt LED Spotlight (WW))/Wipro/ Osram
24M & L submain wiring with two runs of 1.5 Sqmmsingle core PVC insulated but unsheathed multi stranded copper conductor FRLS 1100 volts grade cable drawn through and including PVC conduit and one run of 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable as earth conductor in concealed/surface casing caping but shall be increased as per actual site requirement in accordance with clause No. 19.125 of SSR Part-I) ISI marked with wallthickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling etc complete complete as specified.
25M & L submain wiring with two runs of 4 Sqmmsingle core PVC insulated but unsheathed multi stranded copper conductor FRLS 1100 volts grade cable drawn through and including PVC conduit / PVC Casing caping and one run of 2.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable as earth conductor in concealed/surface casing caping but shall be increased as per actual site requirement in accordance with clause No. 19.125 of SSR Part-I) ISI marked with wallthickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling etc complete complete as specified.
26Taking down old / Existing Out door unit and M&L for detecting the cause of leakage in any type/capacity of 1.5 tonne/2.0 AC and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity and re install on roof includingproviding appropriate water piping and as directed by EIC including testing for smooth functioning complete all as specified and as directed.
27M&L for refrigerant tubing for Suction/Discharge/liquid tube copper pipe of size including 3/8 & 5/8 inches OD with insulation packing all as per site requirement and as directed by Engr-in-Charge