Tripura State Electricity Corporation Limited-TSECL has published Tender For Extension Of Additionalht /Lt Line(Additional Quantity From Previous Parmanent Connection Estimates) Alongwith 2X100kva Substationfor Providing Connection To Bru Settlement Rehabilitants At Kalajhari Area Under Amarpurr.D Block Within The Juris. Submission Date for this Tender is 27-12-2022. Overhead Line Tenders in amarpur Tripura. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supply |
2 | 9.0 mtr. Long steel TublurPole |
3 | 8 mtr. Long steel TublurPole |
4 | 9 mtr. Long PCCPole |
5 | 8 mtr. Long PCC Pole |
6 | Stay set complate |
7 | 11 KV Stay/Guy insulator (Porcelin) |
8 | LT Stay/Guy insulator (Porcelin) |
9 | Stay wire 7/2.50 sqmm |
10 | MS Channel (100 x 50x50x 6 mm ) |
11 | MSl Channel ( 75 x 40x40x 6 mm ) |
12 | MS Angle ( 65x 65x 6 mm) |
13 | MS Angle ( 50x 50x 6 mm) |
14 | 11 KV 2 GOS(three phase Polymeric type) |
15 | 11 KV 2 DOF (three phase Polymeric type) |
16 | 11KV L.A (Polymeric 9KV, 5KA) |
17 | 11KV Polymeric composite 45KN Disc Insulator |
18 | 11KVDisc fittings(6/1/2.59 & 6/1/3.35) |
19 | 11KV 320 mm CD polymer composite PIN iNsulator |
20 | ACSR Weasel(30.00Sq. Mm) Conductor |
21 | 8 SWG G.I Wire |
22 | LT Shackle Insulator(3x3.5) |
23 | LT Shackle straps and bolts |
24 | 12X300mm and 16x75mm etc assorted N&B |
25 | MS Nuts & Bolts (2.3&4) |
26 | LT AB Cable(3x35+1x16+1x25) Sq. mm |
27 | LT Insulation Piercing Connectors(IPC) main 16-95 Sq. mm & tap 4 to 35(50) Sq.mm |
28 | Eye hook |
29 | Cable end Cap(25-35mm/50mm) |
30 | Service line Anchor clamp 18-50mm |
31 | Cable Ties |
32 | Pole Clamp(25-50mm) |
33 | Suspension Clamp Asembly with straps & Buckle(25-35 mm) |
34 | LT Dead End Clamp Assembly with Straps & Buckle(25-35 mm) |
35 | Distribution Box Three Phase(25 mm) |
36 | 100 KVA Transformer(Three Phase) |
37 | 11KV Danger plate |
38 | Rewireable porceliene Cut-Out 100Amps |
39 | Bimetalic Lugs(120 Sq. mm) |
40 | PVC Single Core 16mm Sq. |
41 | PVC Single Core 70mm Sq. |
42 | Erection |
43 | Supply of fabricatedclamp of assorted size of MS flat (50x6mm) with double Coat of red oxide promer coated & 2 nos ISI marked machine made nut & bolts of Size 16x75 mm & washer for erection of stay set. |
44 | Supply of stay clamps of assorted size of MS flat (50x6mm)for erection of stay set |
45 | Supply of 60 Kg Salt and 55 Kg Charcoal (For 1 Pit) |
46 | Supply of 2.5 mtr. Long 40 mm dia G.I Pipe(Make TATA JINDAL) |
47 | 8mtr. Long PCC Pole at any kind of soil upto a depth of 1/6th of pole heightin/c excavation, refilling the pit with soil up to the ground level , ramming & making complete in all respect i/c hand cart carriage & manual carriage with necessary loading & unloading etc as reqd.( PCC Pole 8 mtr long ) |
48 | 9 mtr. Long PCC Pole at any kind of soil upto a depth of 1/6th of pole heightin/c excavation, refilling the pit with soil up to the ground level , ramming & making complete in all respect i/c hand cart carriage & manual carriage with necessary loading & unloading |
49 | 8 mtr. Long Tubular Pole at any kind of soil upto a depth of 1/6th of pole heightin/c excavation, refilling the pit with soil up to the ground level , ramming & making complete in all respect i/c hand cart carriage & manual carriage with necessary loading & unloading etc as reqd.( ST Pole 8 mtr long (SP 30) |
50 | 9 mtr. Long Tubular Pole at any kind of soil upto a depth of 1/6th of pole heightin/c excavation, refilling the pit with soil up to the ground level , ramming & making complete in all respect i/c hand cart carriage & manual carriage with necessary loading & unloading etc as reqd.( ST Pole 8 mtr long (SP 30) |
51 | Painted stay set complete direct in earth with 19 mm dia 1.8 mtr long painted stay rod ,anchor plate of size 300x300x8 mm ,thimble, turn buckle ,7/3.15 mm dia GI stranded wire & stain insulatorinsulator etc in/c supply of MS Clamp,Nut & Bolts etc asa reqd. & making complete in all respectas direction of Eng-in-charge (GI Stay set HT 20 sq mm) |
52 | Painted Stay set complete direct in earth with 19 mm dia 1.8 mtr long painted stay rod ,anchor plate of size 300x300x8 mm ,thimble, turn buckle ,7/3.15 mm dia GI stranded wire & stain insulatorinsulator etc in/c supply of MS Clamp,Nut & Bolts etc asa reqd. & making complete in all respectas direction of Eng-in-charge (GI Stay set LT 16 sq mm) |
53 | 0.8 mtr long MS Channel (100 x 100x50x 6 mm ) for sub stn. etc |
54 | 2.8 mtr long MS Channel (100 x 100x50x 6 mm ) for sub stn. etc |
55 | 2.8 mtr long MS Channel ( 75 x 40x40x 6 mm )for sub stn. GO,DO fixing bkt. Etc |
56 | MS Channel ( 75 x 40x40x 6 mm ) 0.3mtr longfor single poletopcross arm |
57 | MS Channel ( 75 x 40x40x 6 mm ) 1.2mtr longfor single polebottamcross arm |
58 | MS Channel ( 75 x 40x40x 6 mm ) 2.2mtr longfor single polebottamcross arm |
59 | MS Angle ( 65x 65x 6 mm) 1.5 mtr long SPGuarding cross arm |
60 | MS Angle ( 65x 65x 6 mm) 2.8 mtr long DPGuarding cross arm |
61 | MS Angle ( 65x 65x 6 mm) 2.5 mtr long DP cross arm |
62 | 11 KV 200 Amp GOS unit set of three nos inc. necessary connection complete as per technical specification (Excluding the cost of back clamp, nuts & bolts)11 KVG.O.S (three phase)(Polymeric type) |
63 | 11 KV DOF unit set of three nos inc. necessary connection complete as per technical specification (Excluding the cost of back clamp, nuts & bolts) 11 KV D O F (three phase)(Polymeric type) |
64 | 9 KV, 5 KA single pole metel oxide gapless type LA, inc. necessary connection complete as per technical specification.11 KV PolymericLA,9 KV,5KA |
65 | 11 KV disc insulator with fittings, nuts & bolts, washers etc. as reqd. as per direction of Engineer-in-charge. (11 KV Polymer composite 45 KN Disc Insulator) |
66 | 11 KV 320 mm CD Polymer composite PIN Insulator |
67 | Erection ofACSRweasel (30 Sq. mm ) ConductorLaying & stringingin/c hoisting &binding etc. complete as required |
68 | Erection of 8 SWG Gi wire Laying & stringing in/c hoisting &binding etc. complete as required |
69 | Erection of LT AB Cable (3x35+1x16+1x25) Sq. mmLaying & stringingin/c hoisting &binding etc. complete as required |
70 | Erection &fitting & fixing of LT Insulation Piercing Connectors (IPC)all sizes of 1.1 KV grade in/c connection from main cable to distribution box, Tee-Off line as per direction og Eng-in-charge. |
71 | Erection &fitting & fixing of LT Insulated Dead End Anchoring Clamp in/c pole clamp, Eye Hook for cable messanger of1.1 KV grade PCC/ST pole with the help of pole brackets or Steel Straps & Buckleas per direction og Eng-in-charge. |
72 | Erection &fitting & fixing of LT Insulated Suspension Clamp in/c pole clamp, Eye Hook for cable messanger of1.1 KV grade PCC/ST pole with the help of pole brackets or Steel Straps & Buckleas per direction og Eng-in-charge. |
73 | Erection &fitting & fixing of service main 3 phase distribution boxof1.1 KV grade PCC/ST pole with the help of pole brackets or Steel Straps & Buckleas per direction og Eng-in-charge. |
74 | Insttalation/ Positioning of 11/0.430 KV , 3 phase 63 KVA distribution transformer on polewithnecessary connections & fitting & fixing of all allied assessories , components as redq.For making complete in all respect for energizing |
75 | Fitting & Fixing11KV Danger plate |
76 | Fabrication of Steel Materials |
77 | Providing Sub-Station protective fencing by 75 x25 mesh of 2.5x3.5 mtr.and height of 1.5 mtr. As per Engineering recruitment by 01 nos. MS Angle post (50x50x6mm) of height 2.0mtr .Horizontal Bar 6x3.5 mtr and 6x2.5 mtr and vertical Bar 10x1.5 mtr of MS flat (35x6mm) and single part of MS Grildoor of size L-1.5 / B-1.2 mtr with locking arrangement including necessary grouding and painting by Aluminium paint over red oxide priming of approved quality as reqd . as per TS including supply of all materials (MS Angle will be supplied by the Deptt) |
78 | Erection Earthing with G.I pipe 2.5 mtr. Long and 40 mm dia, inc. excavation, refilling with alternate layer of salt & charcoal as per drawing (excluding supply of G.I wire, nuts & bolts, etc. as required). |
79 | Erection of protective guarding / cross lacing for 415/240 volt line by GI wire 98/10 SWG as per technical specificationacross road/river/telecom line etc.in horizontal/verticle formation complete with spool/Reel insulator |
80 | Grouting with CC of Ratio 1:2:4(1 Cement(Cement Concrete, A= 600 x600 x630 -(3.14x(165/2)Sqx630)=220108443.8Sqmm, B=3.14x(420/2)Sqx457-(3.14x(165/2)Sqx457)=53516785.38Sqmm, A+B =273624229.2Sqmm=0.273 Cum)):2 Rover Sand: 4 Jhama Brick Aggregate of 20 mm, normal Size) including supply of Cement sand and brick aggregate complete with excavation, refilling of earth ramming alongwith centering shuttering as required @ 0.273 cum per Steel Tubuler Pole as per TSECL Specification etc. and applying paints with ready mixed primer(Two or more coats) and alluminium paint of approved quality to give an even shade etc, as required as per direction of Engg-In-Charge. |
81 | Maintening adequate clrearance from overhead line conductors by trimming of tree branches for way leaves |
82 | Carriage of9.0Mtr long PCC poles by mechacical Transport from ESD-AMPstoreyardto working site including loading, unloading and stackingetc. as reqd.a) Upto the lead range of 25KM , i) For maximum 5(five) poles, ii) Beyond 5(five) poles |
83 | Carriage of8.0Mtr long PCC poles by mechacical Transport from ESD-AMPstoreyardto working site including loading, unloading and stackingetc. as reqd. a) Upto the lead range of 25KM, i) For maximum 5(five) poles, ii) Beyond 5(five) poles |
84 | Carriage of8.0Mtr length Steel Tubularpoles by mechacical Transport from ESD-AMPstoreyardto working site including loading, unloading and stackingetc. as reqd. a) Upto the lead range of 25KM , i) For maximum 5(five) poles, ii) Beyond 5(five) poles |
85 | Carriage of9.0Mtr length Steel Tubular poles by mechacical Transport from ESD-AMPstoreyardto working site including loading, unloading and stackingetc. as reqd. a) Upto the lead range of 25KM , i) For maximum 5(five) poles, ii) Beyond 5(five) poles |
86 | Providing single phase service connection with laying of PVC cable from nearby Electrical Pole to the consumer premises upto 35Mtr. In length supported by G.I wire, Reel insulator in/c fitting-fixing of Energy Meter as reqd. |
87 | Carriage of 100kva Trnsformer by mechacical Transport from ESD-AMPstoreyardto working site including loading, unloading and stackingetc. as reqd. |
88 | Drawing of single phase service connection with GI wireReel Insulator etc. As reqd. in/c fitting, fixing & commissioning of Energy meter in consumer premises and supply of 9Watt lamp, 5Amp Holder, 16Amp DP Switch , 16Amp Cutout, main switch etc internal wiring as reqd. in/c a coil earthing (TSECL will supply energy meter) for 260 Nos service approx. (Previous approved rate - Rs.2765.00 + Rs.277.00 (10% enhanced)= Rs.3042.00) as per saubhagya guideline and specification |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy