Public Administrative Department Government Departments Closing in 0 days TDR #35379377

Tender For Construction Of Rcc(Ground Floor) (Three Storied Foundation Provision) Commercial Sheds With Brick Boundary Wall And Gate At Commercial Estate, Baganpara, Dist. Baksa, Btc

Issued by Government Departments · baganpara, Assam
Tender Value
91.76 Lakhs
Estimated cost
Bid Submission
05 Jan 2023
0 days left
EMD
1.83 Lakhs
Bank guarantee accepted
Document Fee
1900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
baganpara → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Rcc ( Ground Floor ) ( Three Storied Foundation Provision ) Commercial Sheds With Brick Boundary Wall And Gate At Commercial Estate, Baganpara, Dist. Baksa, Btc

BOQ

Name of Work: Construction of RCC(Ground floor) (three storied foundationprovision) Commercial sheds with brick boundary wall and Gate at Commercial Estate, Baganpara, Dist. Baksa, BTC
Sl. No. Item Description
1MAIN BUILDING -CIVIL WORKS2.31 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.sq
22.33 Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.
32.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil.
416.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
54.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal sizederived from natural sources)
65.22 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
75.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
85.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
95.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
105.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
115.9.3 Suspended floors, roofs, landings, balconies and access platform
125.9.16 Edges of slabs and breaks in floors and walls5.9.16.1 Under 20 cm wide
135.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
145.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
155.3 Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources).
166.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
172.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
184.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
196.12 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :6.12.1 Cement mortar 1:3 (1 cement : 3 coarse sand)
2010.31 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steelprimer, all complete as per the direction of Engineer-In-charge.
2110.30 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with :10.30.1 4.0 mm thick glass panes
229.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.9.48.1 Fixed to steel windows by welding
2310.6 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.10.6.2 80x1.20 mm M.S. laths with 1.20 mm thick top cover
2413.2 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.1 1:4 (1 cement: 4 fine sand)
2513.4 12 mm cement plaster of mix :13.4.1 1:4 (1 cement: 4 coarse sand)
2611.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick
2711.5 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardeningcompound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
2813.80 Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete.
2913.44 Finishing walls with water proofing cement paint of required shade :13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
3013.50 Applying priming coat: 13.50.3 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
3113.50.4 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)
3213.51 Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :13.51.2 Two coats
334.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
34Electrification Work1.8 :- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq. mm. Copper conductor single core cable etc. as required.1.8.1Group A
351.8.2Group B
361.14 :- Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.1.14.2 2 x 2.5. sq. mm + 1 x 2.5 sq. mm earth wire
371.14.32 x 4 sq. mm + 1 x 4 sq. mm earth wire
381.14.4 2 x 6 sq. mm + 1 x 6sq. mm earth wire
391.22 :- Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.1.22.3 150 mm x 75 mm x 60 mm deep
401.22.6 200 mm x 125 mm x 60 mm deep
411.22.7 200 mm x 150 mm x 60 mm deep
421.24 :- Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.1.24.1 5/6 A switc
431.24.4 3 pin 5/6 socket outlet
441.25 :- Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
451.28 :- Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1.28.3 4 Module
461.28.4 6 Module
471.28.5 8 Module
481.29 :- Supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
491.34 :- Supplyingand fixing brass batten/ angle holder including connection etc. as required.
501.44 :- Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
512.3 :- Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)2.3.16 way, Double door
522.10 :- Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.10.1Single pole
532.12 :- Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.12.263A
545.2 :- Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required
555.17 :- Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
56MR – 1:- Supplying with including fitting fixing Of ceiling fan etc. as directed by the Deptt.
57MR – 2 :- Supplying with including fitting fixing Of tube light etc. as directed by the Deptt.(Bajaj make) Code No. 11249 luminaries type 18 WH white.
58MR – 3 :-Supplying with including fitting fixing of LED Bulb 9 Watt. Etc. as directed by the Deptt.(LED home lighting Solution.)
59MR- 4 :- Supplying and fitting fixing 2 H.P. Single phase Centrifugal Mono block Pump set sync speed 2900 rmp. Model No. KDS-213with DOL Starter Control & switch gear (/ BCH/ L&T/Siemens/ equivalent make). With all accessories complete as required and as directed by the department.
60Payment to be made to the APDCL authority for load Security
61Brick Boundary Wall with gate Construction ofbrick boundary withintermediate RCC post tie beam , including cement bplastering both side wall and cement point complete as directed. i) Length of Wall (B)1. south side - 25.00 Rm 2. West side 10.00 RmT= 35.00 Rm
62ii) Length of Wall (A) 1. East side - 33.00 Rm2. South side 22.003. West side - 23.00 T= 78.00 RmDeduct for Gate - 1 x 5.00 = 5.00 Rm , 1 x 1.50 = 1.50Rm . T= 6.50 Rm,@ 78.00 Rm (-) 6.50 Rm = 71.50 Rm , T= 71.50 Rm
632.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
6416.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
654.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.5B 1:3:6 (1 cement : 3 manufactured sand derived from Recycled concrete Aggregate (RCA) : 6 graded stone aggregate 20 mm nominal size Recycled Aggregate (RA) )
665.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
675.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
685.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
695.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
705.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
715.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources)
725.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement5.2.2A 1:1.5:3 (1 cement : 1.5 coarse sand incuding manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA) upto 20%
7313.2 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.1 1:4 (1 cement: 4 fine sand)
7413.43 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :13.43.1 Water thinnable cement primer
7513.44 Finishing walls with water proofing cement paint of required shade :13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
769.48 Providing and fixing M.S. grills of required pattern in frames of windowsetc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete.9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc
7713.52 Finishing with Epoxy paint (two or more coats) at all locations preparedand applied as per manufacturer\"s specifications including appropriatepriming coat, preparation of surface, etc. complete.13.52.1 On steel work
78Hand Tube well 18.42 Boring with 100 mm diameter casing pipe for hand pump / tube well, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested :18.42.3 Beyond 12 m and up to 18 m depth
7918.43 Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality
8018.44 Providing and fixing to filter and lowering to proper levels 40 mm G.I. pipe for tube well including cleaning and priming the tube well.
8118.45 Providing and placing in position hand pump of approved quality for 40 mm diameter G.I. pipe complete with all accessories
822.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil.
8316.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
844.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.10 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
856.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
8613.2 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.1 1:4 (1 cement: 4 fine sand)
8711.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick
8811.5 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2
89Earth Filling2.25(a) Excavation, Earth filling, supplying and filling of local earth (including Royalty) by mechanical transportup to a lead 5KM also including running and watering of the earth in layers at exceeding 20 Cm in trenches, plinth, sides of foundation etc. completeTotal land area= 33.00x47.00 = 1551.00 SqmTotal Volumeas per profile measurement= 1551.00x1.48=2295.48 CMDeduct 12.5 % for shrinkage =2295.48x12.5%= 286.93 CMNet volume =2295.48-286.93=2008.55 CM

AI Tender Summary

OUR REF NO 35379377
AUTHORITY Government Departments
TENDER VALUE 91.76 Lakhs
LAST DATE 05-01-2023
Authority
Authority Name Bodoland Territorial Council
Work Description Construction Of Rcc ( Ground Floor ) ( Three Storied Foundation Provision ) Commercial Sheds With Brick Boundary Wall And Gate At Commercial Estate, Baganpara, Dist. Baksa, Btc
Basic Detail
Tender No No-5/2022-23
Bidding Type Tender
Location
City baganpara
State Assam
Key Dates
Publish Date 21 Dec 2022
Submission Date 05 Jan 2023
Open Date 05 Jan 2023
Finance
Tender Value 91.76 Lakhs
Tender Fee 1900
EMD 1.83 Lakhs
Exemption Not Available
Document List
250534cd-24b8-407e-a034-492d72156509.html
FOB_Baganpara.pdf
SBD_Baganpara.pdf
Tendernotice_1.pdf
BOQ_45164.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 21, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 05, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 05, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

250534cd-24b8-407e-a034-492d72156509.html

pdf

FOB_Baganpara.pdf

pdf

SBD_Baganpara.pdf

pdf

Tendernotice_1.pdf

xls

BOQ_45164.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders