Tender For Repair/Maintenance Of All Types Of Dg Set, Amf Panel And Other Connected Works In Metcalfe House And Jcb Lab Under Ge I Rnd Delhi, delhi-Delhi

Military Engineer Services-MES has published Tender For Repair/Maintenance Of All Types Of Dg Set, Amf Panel And Other Connected Works In Metcalfe House And Jcb Lab Under Ge I Rnd Delhi. Submission Date for this Tender is 21-01-2023. Prime Mover Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

35373076
Corrigendum : Tender For Repair/Maintenance Of All Types Of Dg Set, Amf Panel And Other Connected Works In Metcalfe House And Jcb Lab Under Ge I Rnd Delhi
Open Tender
Indian
Delhi
delhi
21-01-2023

Tender Details

Tender For Repair / Maintenance Of All Types Of Dg Set, Amf Panel And Other Connected Works In Metcalfe House And Jcb Lab Under Ge I Rnd Delhi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Jan-2023 Corrigendum01 Date 14-01-2023
2 06-Jan-2023 Corrigendum02 BOQ 14-01-2023
3 14-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 86500.0 /-
Tender Value
Refer document

BOQ Items

NAME OF WORK : REPAIR/MAINT OF ALL TYPES OF DG SET,AMF PANEL AND OTHER CONNECTED WORKS IN METCALFE HOUSEAND JCB LAB UNDER GE I RND DELHI
Sl. No. Item Description
1M&L for B check general servicing by authorised representative of manufacturer of DG set of capacity 125 KVA, replacement of oil filter, fuel filter, air filter, by pass filter cleaning of radiator with chemical afterdraining out engine/ lubrication oil, coolant flushing and cleaning of oil chamberafter opening of tappet cover/ top cover tappet clearence setting with injector timing adjustment refixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof solution, oil pan/ chamber gasketat the servicing and other work comes under B Check service as mentioned in B Check by the manufacturer complete all as specified and directed. Note:- Engine oil & Coolant will be paid separately under respective item.
2All as per item Ser No 1.00 above but of capacity 180 KVA.
3All as per item Ser No 1.00 above but of capacity 200 KVA.
4All as per item Ser No 1.00 above but of capacity 250 KVA.
5All as per item Ser No 1.00 above but of capacity 300 KVA.
6All as per item Ser No 1.00 above but of capacity 380 KVA.
7All as per item Ser No 1.00 above but of capacity 750 KVA.
8M&L for repair of self starter 12 V including rewinding of armature with super enamelled copper conductor wire of superier quality as per existing gauge, turn and pattern and replacement of bendex drive, carbon brush including services suitable for DG set 62.5 to 125 KVA complete all as specified and directed.
9M&L for repair of self starter 24 V including rewinding of armature with super enamelled copper conductor wire of superier quality as per existing gauge, turn and pattern and replacement of bendex drive, carbon brush including services suitable for DG set upto 750 KVA complete all as specified and directed.
10S&F in replacement of automatic battery charger with auto cut OFF suitable for 2X12V 180AH batteries with all required necessary wiring complete all as specified and directed.
11M&L for replacement of wiring complete to AMF panel for any capacity of DG set including interlock system of AMF panel with existing size of copper wiring including proper connection and testing complete all as specified and directed.
12S&F in replacement of self starter 24 volts suitable for upto 750 KVA DG sets complete all as specified and directed.
13S&F in replacement of battery brass terminals heavy duty suitable for 12V 180 AH battery with minimum 2 RM Battery Lead of copper cable single core complete all as specified and directed.
14S&F in replacement ofrelay 24 V 8 pin type as per matching to existing and properly connection and testing after completion complete all as specified and directed.
15S&F in replacement ofengine starting relay suitable for DG set of capacity upto 125 KVA as per matching to existing complete all as specified and directed.
16S&F in replacement ofengine starting relay suitable for DG set of capacity 200 to 750 KVA as per matching to existing complete all as specified and directed.
17S&F in replacement of Electronic timer suitable for AMF panel of DG setas per matching to exisitng, 230 V AC 50 Hz complete all as specified and directed.
18S&F in replcement of Voltmeter analog type for voltage range of (0-24V) as per matching to existing complete with all accessories and wiring complete all as specified and directed.
19S&F in replacement of Voltmeter analog type for voltage range of (0-500V) complete with all accessories and wiring complete all as specified and directed.
20S&F in replacement of Ammeter analog type for current range of (0-24Amps) as per matching to existing complete with all accessories and wiring complete all as specified and directed.
21S&F in replcement of Ammeter analog type for current range of (0-1000Amps) as per matching to existing complete with all accessories and wiring complete all as specified and directed.
22S&F in replacement of power contactor ML 6 suitable for AMF panel of DG set as per matching to existing complete all as specified and directed.
23S&F in replacement of power contactor ML 4 suitable for AMF panel of DG set as per matching to existing complete all as specified and directed.
24S&F in replacement of power contactor ML 3 suitable for AMF panel of DG set as per matching to existing complete all as specified and directed.
25S&F in replacement of power contactor ML 2 suitable for AMF panel of DG set as per matching to existing complete all as specified and directed.
26S&F in replacement of selector switch suitable for voltmeter and Ammeter complete all as specified and directed
27S&F in replacement of under voltage relay suitable for DG set upto 380 KVA complete all as specified and directed.
28Supply and Fix in replacement of complete wiring with single core 2.50 Sqmm multistranded copper cable with flexible conduit 15mm dia for DG set of various capacities complete all as specified and directed.
29S&F and testing Electronic Governor Controller for 200 to 750 KVA DG Set including taking down old Governor Controller complete all as specified and directed.
30Taking down the old unserviceable actuator from its position and S&F new actuator for upto 750 KVA DG set complete all as specified and directed.
31Opening the DG set of200 to 380 KVA , repair to any leakage in radiator, greasing of all movable parts & equipments and replacing allflexible/steel wire mesh type hose pipes including fuel pipe line, belts & bearings including re-assembling the complete parts and testing complete all as specified and directed. Note :- Spare parts required for replacement shall be measured & paid under following item.
32S&F Piston ring and liner for 200 to 380 KVA DG Setas per existing make & OEM complete all as specified and directed.
33Supply only Head valve, Head Guide, Head sheet & Head seal for 200 to 380 KVA DG Set as per existing make & OEM complete all as specified and directed.
34Supply only Injector sleeves & Head gasket for 200 to 380 KVA DG Set as per existing make & OEM complete all as specified and directed.
35Supply only Packing Kit for200 to 380 KVA DG Set as per existing make & OEM complete all as specified and directed.
36M&L for repair of Head and fuel injector assembly complete for 200 to 380 KVA complete all as specified and directed.
37M&L for repair of Turbo assembly completefor 200 to 380 KVA complete all as specified and directed.
38Opening the DG set of 750 KVA , repair to any leakage in radiator, greasing of all movable parts & equipments and replacing allflexible/steel wire mesh type hose pipes including fuel pipe line, belts & bearings including re-assembling the complete parts and testing complete all as specified and directed. Note :- Spare parts required for replacement shall be measured & paid under following item.
39S&F Piston ring and liner for 750 KVA DG Setas per existing make & OEM complete all as specified and directed.
40Supply only Head valve, Head Guide, Head sheet & Head seal for 750 KVA DG Set as per existing make & OEM complete all as specified and directed.
41Supply only Injector sleeves & Head gasket for 750 KVA DG Set as per existing make & OEM complete all as specified and directed.
42Supply only Packing Kit for750 KVA DG Set as per existing make & OEM complete all as specified and directed.
43M&L for repair of Head and fuel injector assembly complete for 750 KVA complete all as specified and directed.
44M&L for repair of Turbo assembly completefor 750 KVA complete all as specified and directed.
45Taking down the old unserviceable fan belt and Supply andFix Fan belt of existing size for DG Set of capacity 125 to 200 KVA complete all as specified and directed.
46Taking down the old unserviceable fan belt and Supply andFix Fan belt of existing size for DG Set of capacity 250 to 380 KVA complete all as specified and directed.
47Taking down the old unserviceable fan belt and Supply andFix Fan belt of existing size for DG Set of capacity 750 KVA complete all as specified and directed.
48Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifoldfor DG set 300 KVA including removing of existing asbestos rope or any other type of insulation complete all as specified and directed.
49S&F in replacement fly wheel ring of DG set of capacity 125 KVA complete all as specified and directed
50S&F in replacement fly wheel ring of DG set of capacity 200 to 380 KVA complete all as specified and directed
51Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 125 to 200 KVA complete all as specified and directed
52All as per item Ser No 39.00 above but 250 KVA.
53All as per item Ser No 39.00 above but 300 to 750 KVA.
54S&F in replacement of Changeover switch on load front operated 300 Amps 4 Pole 415 volt complete including properly connecting incoming and outgoing cable andtesting after completion complete all as specified and directed
55M&L for repair toradiator of 125 to 200 KVA DG set, arresting leakage if any by welding/brazing and refixing the same for complete all as specified and directed. Note :-Necessary coolant and distilled water required will be measured and paid seperately.
56All as per item Ser No 43.00 above but 250 to 380 KVA.
57M&L in replacement lead acid battery of size 12 Volt, 180 AH including charging complete all as specified directed.
58Removing old unserviceable insulating material asbestos rope and fixing of new asbestos rope of existing size and shape complete all as specified and directed.
59M&L for Spray painting of diesel generating setof capacity 125 to 200 KVA of accostic enclosure/open type with one coat of synthetic enamel paint, body colour shall be apple green, black for foundation base frame, red for all guards including preparing old surfaces complete all as specified and directed.
60All as per item Ser No 47.00 above but 250 KVA.
61All as per item Ser No 47.00 above but 300 KVA to 750 KVA.
62M&L for PCC 1:2:4 type B2 (using 20mm graded stone aggregate) for foundation of pole complete all as specified and directed.
63S&F in replacement of3 Pole MCCB, 630 Amp, 50 Hz, 415 V 36 KA rupturing capacity with microprosseor release and adjustable overload setting complete all as specified and directed.
64S&F in repair MCCB 125 Amps 3 pole breaking capacity 35 KA complete all as specified and directed
65All as per item Ser No 52.00 above but 100 Amp 3 pole 25 KA.
66All as per item Ser No 52.00 above but 250 Amp 3 pole 25 KA.
67All as per item Ser No 52.00 above but 200 Amp 3 pole 25 KA.
68S&F in repair MCCB 630 Amps 4 pole breaking capacity 50 KA complete all as specified and directed.
69S&F in repair MCCB 400 Amps 4 pole breaking capacity 36 KA complete all as specified and directed.
70S&F in repair MCCB 250 Amps 4 pole breaking capacity 36 KA complete all as specified and directed.
71Material and Labour for earthing complete with Steel earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron earth wire 4.00 mm dia by means of Copper nuts, bolts and washers.GI wire shall be laid in 20 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a)GI wire of 4 mm dia. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c)Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm diamild steel TMT bars suitable for carrying of pit cover.
72M&L for earth continuity conductor main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 4 mm galvanised iron wire complete all as specified and directed.
73Supply and laying in replacement GI pipe light grade of 50mm dia including new fittings laid in trenches or under road crossing for protection of UG cable complete all as specified and directed
74All as per item Ser No 61.00 above but 80mm dia.
75M&L for boring of holes under road, pavement, hard standing by trenchless techonology using ultra sound technique/mannually/mechanically and necessary machine including supply and laying of 100mm dia GI pipe light grade complete all as specified and directed.
76S&F in repair alternator of DG Set of capacity upto 200 KVA complete including rewinding & replacement of connected items such as bearing, sleeves Nut bolts, coupling etc complete all as specified and directed.
77All as per item Ser No 64.00 above but of capacity 200 KVA.
78Supply, installation, testing & commisioning ofAuto Main Failure (AMF) panel made out of 2 mm CRCA sheet in Door type, powder coated conforming to IS 8623 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase, 4 Wire, AC 50 Hz having aluminium bus bar capacity required tocarry current at 110% load of 200 KVA DG set with three phase and half neutral colour coded, pre-wired with copper flexible cable of size 4 Sqmm all as specified with the following accessories, control cable from Gen set to AMF panel& finishing complete with 7 tank process for powder coating in approved shade,having IP-42 degree of protection with hinged lockable doors,dust and vermin proof CPRI approved IP-54 duly painted with epoxy based powder coated paint complete all as specified and directed :- (i) Micro processor based MCCB 3 Pole of suitable capacity as recommended by OEM ,Manual draw out type with electrical contactor 500 Amps 4 pole for alternator (DG supply and Main Supply) -02 Nos. (ii) AIl controls indicators and standard fittings as follows : (a) Digital type Ammeter with in built selector switch ofsuitable capacity with CTs- 1 set. (b) Digital- type Voltmeter with in built selector switch of suitable capacity- 1 set. (c) Multifunctional digital meter for KWH, KVA, KW Amps, Volts, frequency, power factor etc.-1 No. (iii) Functions:- (a) Supply failure timer and restroration - 1 No (b) 3 impulse automatic engine Start/ stop logic.
79(iv) Announceation with indicators LED lamps for (a) Protective over loading relay-1No (b) Low bulb oil pressure, high water temperature, Engine overspeed, battery low voltage, under voltage -1 No, Earth fault relay-1 No. (v) Controls (a)Load on indicators. (b)Load Off indicators. (c)Engine start push button. (d)Engine stop push button. (e)Fault except/reset push button. (vi) Batterycharging SMPSunit within auto built manual : (a ) DC Volt meter. (b) DC Ammeter. (c) Charger rate selector switch.
80S&F earth pit chamber alongwith cover of Polymer, FRP Pit Cover of heavy high grade polypropelene for high stress and starin level of size 225x300x 195 mm complete all as specified and directed.
81S&F in replacement ACP retro sign board of size 1.5 x 1.1 Mtr using retro reflective high intensity prismatic reflective sheeting. The back ground of board is blue colour with white border and writing letter, numbers white colour mentioning the DG Set substation details, and single line schematic diagram of substation. Retro sign board shall be pasted on 3 mm thick ACP sheet. The board shall be fixed on Wall including fixing offastners, nuts, bolts, washer etc complete all as specified and directed.
82M&L in repair MS chequred plate of suitable size for cable duct cover 6mm thick and earth pit cover complete all as specified and directed.
83Excavation in trenches in soft/loose soil not exceeding 1.5m depth & not exceeding 1.5m in width over energised LT cables for carrying out brick work for protection of cable duct including for taking out and relaying of LT Cables etc complete all as specified and as directed.
84Returning, filling in including spreading, levelling watering and well ramming in layers not exceeding 25cm thick in soft/loose complete all as specified and directed.
85Removing surplus excavated materials to a distance n. exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
86M&L for burnt brick sub class "B" standard size for cable protection keeping width of the brick parallel to the length of the cable complete all as specified and directed.
87Supply and laying clean dry river sand in trenches, ducts including leveling, punning for cushioning of cables complete all as specified and directed. Note : Punned thickness of sand cushioning shall be measured.
88Supply and laying in trenches, fixed to wall/pole/tray etc UG cable XLPE insulated armouredheavy duty electric UG cable with aluminumconductor 1100 volts grade of cross sectional area of following size including taking out old unserviceable cable complete all as specified and directed.
8910 Sqmm 2 Core
9016 Sqmm 4 Core
9125 Sqm 3.5 Core
9235 Sqm 3.5 Core
93120 Sqm 3.5 Core
94240 Sqm 3.5 Core
95M&L in replacement of GI bracket made of 40 mm medium grade GI pipe bend to shape approx 1.2 mtr length including clamp, nut, bolt, washer etc complete for fixing of street light complete all as specified and directed.
96S&F in replacement Junction box SMC KIOSK box water proof of size 140x140x95 mm including fixing of terminal connector 100A 4 pole suitable for in and out connection of 4 core cable fixed on pole complete all as specified and directed.
97All as per item Ser No 77.00 above but 300x200x125mm.
98S&F in replacement copper cable 2.5 Sqm 3 core PVC sheathed multi core for connection of street lightinserting from top in side the pole and connectingin junction box complete including making Hole in Pole as per site complete all as specified and directed.
99M&L for PCC 1:2:4 type B2 (using 20 mm graded stone aggregate) for coping around pole complete all as specified and directed.
100S&F LED Post Top Lantern 25W wall luminaire with diffuser and painted spun aluminium deflector including taking down old unserviceable post top lantern complete all as specified and directed.
101S&F in replacement of LED Post Top bollard light 10 Wincluding necessary excavation and PCC work for fixing complete all as specified and directed.
102S&F powder coated pressure die cast aluminium SMD LED street light with heat resistant toughened glass of capacity 45 Watt including taking down old unserviceable street light complete all as specified and directed.
103S&F powder coated pressure die cast aluminium SMD LED street light with heat resistant toughened glass of capacity 70 Watt including taking down old unserviceable street light complete all as specified and directed.
104All as per item Ser No 84.00 above but of capacity 90 Watt.
105All as per item Ser No 84.00 above but of capacity 120 Watt.
106S&F LED flood light with pressure die cast aluminium housing 100 Watt with connectionincluding taking down old unserviceable flood light complete all as specified and directed.
107All as per item Ser No 87.00 above but 150 Watt.
108All as per item Ser No 87.00 above but 200 Watt.
109S&F in replacement driver for 45 W LED street light fitting complete all as specified and directed.
110All as per item Ser No 90.00 above but 75 W.
111All as per item Ser No 90.00 above but 100W.
112All as per item Ser No 90.00 above but 150W.
113S&F LED flood light 250 watt with pressure die cast aluminium housing complete with all accessories including taking down old unserviceable flood light complete all as specified and directed.
114S&F in replacement GI pipe light grade 50mm dia for laying of protection of UG cable complete all as specified and directed.
115S&F in replacement GI pipe light grade 40mm dia for laying of protection of UG cable complete all as specified and directed.
116Material and Labour for earthing complete with Steel earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron strip of 25x4 mmby means of Copper nuts, bolts and washers.Strip shall be laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a)GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly be tightened on GI watering pipe and embeded in PCC earth pit with open top suitable for watering of earth pits) (c)Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.
117M&L in replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 25x4 mm galvanised iron strip complete all as specified and directed.
118S&F in replacement of timer switchastronomical type, 415 Volt three Phase of 63 Amps rating with Three Pole ML-4contactor including one toggle switch for auto, off and Manual function and incomming MCB TP internally pre wired complete and fitted inside steel enclosure all as per site requirement complete all as specified and directed.
119S&F service cable 1100 volts grade heavy duty PVC insulated aluminium multistranded conductor served with inner sheathing of size 10 Sqmm 2 Core complete including taling down of old unserviceable cable complete all as specified and directed.
120M&L for servicing of AMF panel of any size/make, check all loose connections of end terminals, screws, nuts, bolts thimbles, clean all electric/electronic parts by using CRC spray, check contactors connections and its serviceability, check all relay setting of AMF panel and check all internal connections of AMF Panel and hinges and locking devices complete all as specified and directed.
121M&L for preparation of new steel or iron surface over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.