Military Engineer Services-MES has published Tender For Repair / Replacement / Maintenance Of Central Ac Plant -10 Tr, Hot Water Generator, Central Heating Plant (10 Tr And 33 Tr) Heaters / Blowers And Certain Misc Works At 901 Su Af Stn Nathatop. Submission Date for this Tender is 16-01-2023. Electric Generator Tenders in udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

35373006
Corrigendum : Tender For Repair / Replacement / Maintenance Of Central Ac Plant -10 Tr, Hot Water Generator, Central Heating Plant (10 Tr And 33 Tr) Heaters / Blowers And Certain Misc Works At 901 Su Af Stn Nathatop
Open Tender
Indian
Jammu And Kashmir
udhampur
16-01-2023

Tender Details

Repair / Replacement / Maintenance Of Central Ac Plant -10 Tr, Hot Water Generator, Central Heating Plant (10 Tr And 33 Tr) Heaters / Blowers And Certain Misc Works At 901 Su Af Stn Nathatop

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-01-2023
2 10-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work :Repair /Replacement/Maintenanceof central AC plant -10 TR, Hot water Generator, Central Heating plant (10TR/&33TR Heater/blowers and certain Misc works at 901 SU AF Stn Natatop..
Sl. No. Item Description
1Maintenance / servicing / repairing/ cleaning / Painting works/ for AC plant package type 10 x 3= 30 TR package plant,condenser Air cooled type-06 Nos, Compressor 5.5 TR -06 Nos, Thermometer / pressure gauge/ complete duct / AHU packagecomplete system, Connection tubes, PCB & sensor system, humidifier system (heating)/ hot water generatorand the following works/maintenancecarried out this scope work & and replacement of unsvparts paid separately mentioned &complete Natatop stn all as specified and directed Engr-in-Charge . (Note :1 :- Item Srl no: 1, (a) Above all attending to complaint/break down calls when called upon.Repair/replacement of microprocessor control if installed.Reporting the healthiness of the plant and suggesting improvements if any) (b)The work will be carried out either by Voltas personnel or its authorized sub- contractors as directed by Voltas. (c) This scheme does not cover damage to equipment / ancillaries or failure due to environmental conditions and due to contaminated / hard water, there itmes measured and paid separatly under respetive schedule. (d) Each plant will be tested in the presence of GE, Engineer-in- Charge and ref of the user unit. (e) The test results shall be recorded and shall be preserved duly signed by the contractor, Engineer-in- Charge and ref of the user unit. (f)The contractor shall get the sample of all the materials approved from in presence of Rep of user before placing the order for bulk procurment (g)The material procured and brought at site by the contractor shall be got approved from Engr-in- Charge in presence of rep of user before incorporation in the work. (i)Clean water strainers. (ii)Check the earth connection and fuses.(iii)Clean the condenser and otherequipments. (iv)Check for leakage of gas (exterior).(v)Clean the controls.(vi)Clean all the air filters.(vii)Check compressor oil for discoloration or contamination. (viii)Check starting and running current and voltage while running.(ix)Check the insulation resistance valve. (x)Defrost cooling coil, close suction line slowly and note the efficiency.(xi) Check leak in the seal of shaft.(xii)Check leak LP and HP cut-outs i.e. 5 lbs/inch2 for LP and 150 lbs/inch2 for HP.(xiii) Check expansion valves. (xiv)Check for entire system with the help of water & soap.(xv) Clean the drip tray with water.(xvi)Check the condition of blower fans, shafts and its direction of rotation.(xvii)Check the ducting condition.(xviii) Check the working of the plants and limits of vibration and noise (xix) Carry out the capacity test. (xx) Check suction and delivery of the compressor and its efficiency.(xxi)Clean the condenser with compressed air, brush and water carry out pressure test at 250 psi of CO2 for any eaks.(xxii)Dismantle the weather make chamber by removing duct connections and opening the return air box, clean the evaporator coil, drip tray, ducting and repair the return air box (if required) , paint the system and re-install the same.(xxiii) Overhaul the blower motor including cleaning of runners.(xxiv) Check the service valves for wear.(xxv)Overhaul the compressor motor and starter xxviClean the contacts of LP/HP switches.(xxvi) Check and adjust the alignment of belts and their tension.(xxvii)Check the wiring and all the connections including meggering.(xxviii)Complete test for leaks.(xxix) Check thermostatic switch and clean the contacts(xxx) water cooled system/water line clening & paintng incl cooling tower (xxxi) all pump any size overhuling and repairing /replacement of unserviceable gland / shaft/ bearing/ gland cupling complete(xxxii) Cooling tower cleaning with Scrapper .
2M&L for Descaling of Water cooled Condencer of Package unit with cleaning of cooling coil, Air filters and cleaning of Cooling Tower of 10 TR
3M&L for R-22/407 & 410Gas Charging for Ductable & Packaged type AC plant include welding work complete all as specified and as directed.
4M&L forN2 Flushing, leakage testing & Vaccummissing for AC plant complete all as specified and as directed.
5M&L forMotorized Dampers for DuctableAC complete all as specified and as directed.
6M&L forMotorized Dampers for PackagedAC complete all as specified and as directed.
7M&L for the following spare parts complete all as specified and as directed by Engr-in- charge. Note for Srl item No 7.01 to 7.36 : The material procured and brought at site by the contractor shall be got approved from Engr-in- Charge and GE in presence of rep of user before incorporation in the work.
8S&F in repair Compressor of capacity 5.5 toncomplete all as specified and as directed by Engr-in-Charge. Make: Voltas or its equivalent
9S&F in repair PCB circuit for Ductable type AC complete all as specified and as directed by Engr-in- charge.
10S&F in repair PCB circuit for Packaged type AC complete all as specified and as directed by Engr-in- charge.
11S&F in repair Blower motor IDU for Ductable type AC complete all as specified and as directed by Engr-in- charge.
12S&F in repair Blower motor IDU for Packaged type AC complete all as specified and as directed by Engr-in- charge.
13S&F in repair Condensor fan motor ODU for Ductable & Packged type AC complete all as specified and as directed by Engr-in- charge.
14S&F in repair Air filter for Ductable type AC complete all as specified and as directed by Engr-in- charge.
15S&F in repair Air filterfor Packagedtype AC complete all as specified and as directed by Engr-in- charge.
16S&F in repair Blowerfor Ductable type AC complete all as specified and as directed by Engr-in- charge.
17S&F in repair Blower for Packagedtype AC complete all as specified and as directed by Engr-in- charge.
18S&F in repair Single Phase preventer complete all as specified and as directed by Engr-in- charge.
19S&F in repair AL powder coated Grill complete all as specified and as directed by Engr-in- charge.
20S&F in repair AL powder coated Diffusers complete all as specified and as directed by Engr-in- charge.
21S&F in repair Motorized Dampers for Ductabletype AC complete all as specified and as directed by Engr-in- charge.
22S&F in repair Motorized Dampers for Packagedtype AC complete all as specified and as directed by Engr-in- charge.
23S&F in repair HP-LP Switch Ductable type AC complete all as specified and as directed by Engr-in- charge.
24S&F in repair HP-LP Switch Packaged type AC complete all as specified and as directed by Engr-in- charge.
25S&F in repair Sensor for ductable type AC complete all as specified and as directed by Engr-in- charge.
26S&F in repair Sensor for Packaged type AC complete all as specified and as directed by Engr-in- charge.
27S&F in repair Expension valve 5.5 TR complete all as specified and as directed by Engr-in- charge.
28S&F in repair Insulation Nitrile Rubber 13mm complete all as specified and as directed by Engr-in- charge.
29S&F in repair Canvass Connection fire proof complete all as specified and as directed by Engr-in- charge.
30S&F in repair Copper piping, Insulation, supporters, Nut bolts, painting of pipe ( If requierd ) Angle bracket etccomplete all as specified and as directed by Engr-in- charge.
31S&F in repair Acoustic sound proofing complete all as specified and as directed by Engr-in- charge.
32S&F in repair 2 HP motor with long shaft ,3 phase, 415 volt, 50 Hz complete as per existing model with suitable starter complete all as specified and directed by Engr-in- charge. ( Make: Kirlosker/ CRI/Texmo)
33S&F in repair up to 3 HP motorcomplete rewinding and replacing condensior fan body,suitable size of stater ,1 phase, 220 volt, 50 Hz complete setas per existing Model complete all as specified and directed by Engr-in- charge.
34S&F in repair 3 HP motor with long shaft ,3 phase, 415 volt, 50 Hz complete as per existing Modelwith suitable starter complete all as specified and directed by Engr-in- charge. ( Make: Kirlosker/ CRI/Texmo)
35S&F in repair MCCB 4 Pole, Microprocessor Based 250A, Breaking capacity 36 KA, 415 V, 50 Hzwith OL, SC, protection, -01 Nos complete all as specified and as directed by Engr-in- charge. (Make : Siemens cat part No : 3VT2725-2AA46-0AA0,L&Tcat part No 3VT9225-6AP00,Schneider cat part No CM92151OOOOAGor itsEquivalent)
36S&F in repair MCCB 4 Pole, Microprocessor Based 100 A, Breaking capacity 36 KA, 415 V, 50 Hzwith OL, SC, protection, -01 Nos complete all as specified and as directed by Engr-in- charge. (Make : Siemens cat part No : 3VT1710-2EC46-0AA0, L&T cat part No : DZ1F0100DXH1A & or its Equivalent Schneider/Legrand )
37S&F in repair MCCB 4 Pole, Microprocessor Based 160A, Breaking capacity 36 KA, 415 V, 50 Hzwith OL, SC, protection, -01 Nos complete all as specified and as directed by Engr-in- charge. (Make : Siemens: 3VT2725-2AA46-0AA0, L&T cat part No - 3VT9216-6AP00 & Schneider cat part No : CM92152OOOOAG or its Equivalent)
38S&F in repair Heating element 3000 watts complete all as specified and as directed by Engr-in- charge.
39S&F in repair Power contactor 32 Amps 3 pole as per sample complete all as specified and as directed by Engr-in- charge.
40S&F in repair Power contactor 100Amps 3 pole as per sample complete all as specified and as directed by Engr-in- charge.
41S&F in repair Air pressure meter /guageas perexisting model complete all as specified and as directed by Engr-in- charge.
42S&F in repair Temperaturemeter /guageas perexisting model complete all as specified and as directed by Engr-in- charge.
43S&F in repair GM gate Valve glope type 15mm complete all as specified and as directed by Engr-in- charge.
44Disconnectingthe motor with centrifugal pump set and Repair/Rewinding of motor ofcapacity 3/5 HP three phase 415 Volts ,50 HZ byrewinding the motor with super enamelled copper conductor of standard size including varnish, insulation paper and tape . Assembly of motor with pump set with necessary studs, bolts, washers and bearing etc complete all as specified and directed.
45Disconnectingthe motor with centrifugal pump set and Repair/Rewinding of motor ofcapacity 7.5/10 HP three phase 415 Volts ,50 HZ byrewinding the motor with super enamelled copper conductor of standard size including varnish, insulation paper and tape . Assembly of motor with pump set with necessary studs, bolts, washers and bearing etc complete all as specified and directed.
46Disconnecting of startor and Replacement of unserviceable/ burned spare parts robust 4 pole contactor type TC1-DX/ over load relay type LR3DM/ auto start switch with Auto/manual start DIP switch, voltmete with 3P selector switch & TP MCB for Short circuit protection, suitable for relay range 12 to 25 Amps etccomplete all as specified and directed.
47S&F in repair cast iron Butterfly Valve 100mm bore , SS dise type with handlever operated,lining test pressure PN 1.6ISI marked including welding workwith all fittings such as nuts , bolts, washers and rubber gasketetc complete in all respect all as specified.
48S&F in repair cast iron Butterfly Valve 80mm bore , SS dise type with handlever operated,lining test pressure PN 1.6ISI marked including welding workall fittings such as nuts , bolts, washers and rubber gasketetc complete in all respect all as specified.
49S&F in repair cast iron Butterfly Valve , SS dise with handlever operated,lining test pressure PN 1.6ISI marked of size 50 mm diaincluding welding workall fittings such as nuts , bolts, washers and rubber gasketetc complete in all respect all as specified.
50Servicing of hot water boiler, disconcting electric drain out water opening of burner chamber boilerasembly, al accessories and mountingtaking out helical coil of make-alfa therm hot generator 100000K Cal / Hrs, cleaing of combustion chamber reparing/ replacement of any unsv part as specified in eachitcomplete all as specifeid and directed , ms mentioned. Note:-The job shall be carried out during entire period of contract. Repair of hot wate boiler of cqapacity 100000K cal/Hr including repair / replacement of following parts from item No. (a) to (o) to make it functional as specified and directed by Engr-in-Charge.
51S&F in repair helical coil asembly complete all as specified and as directed by Engr-in- charge.
52S&F in repairinput ignition transformer220 volts ofoutput 11KV to 14 KV complete all as specified and as directed by Engr-in- charge.
53S&F in repairgasket suitable for hot water boiler complete all as specified and as directed by Engr-in- charge.
54S&F in repair sequence controller for hot water boiler complete all as specified and as directed by Engr-in- charge.
55S&F in repair refactory plate as per sample complete all as specified and as directed by Engr-in- charge.
56S&F in repair of differential pressure Gauge- 0 to 10 Kg/ Cm square suitable for hot water boiler complete all as specified and as directed by Engr-in- charge.
57S&F in repair photo cell for hot water boiler complete all as specified and as directed by Engr-in- charge.
58S&Fin repair motorised barrel pump of capacity 1 HP , 2850 RPM, Single phase with rubber hose pipe 15 RM complete with all accessories complete all as specified and directed by Engr-in-Charge . Make: Bharat, Kirloskar
59S&F in repairgate valve of capacity 50mm dia suitable for hot/ cold water complete all as specified and as directed by Engr-in- charge. Make: Leader/ surya parkash.
60S&F in repairgate valve of capacity 40mm dia suitable for hot/ cold water complete all as specified and as directed by Engr-in- charge. Make: Leader/ surya parkash ISI marked.
61S&F in repair of solenoid valve for hot water boiler complete all as specified and as directed by Engr-in- charge
62S&F in repair of fuel TPL pipe to buring assembly for hot water boler complete all as specified and as directed by Engr-in- charge
63S&F in repair of fuel filter assembly 1/2 Ltr capacity with filter complete all as specified and as directed by Engr-in- charge
64S&F in repairburner of boiler for 1 L K cal make ecoflame or equivelant or as per sample complete all as specified and as directed by Engr-in- charge
65S&F in repair starting panel of boiler for 1 LK cal make as per sample Rapid cool complete all as specified and as directed by Engr-in- charge
66S&F in repairelectronic buzzer for hot water boiler of 1 L Kcal complete all as specified and as directed by Engr-in- charge
67Replacement of Gun-metal, globeor gate valves, 40mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked),complete all as specified & directed by Engr-in-Charge.
68Replacement of Gun-metal, globeor gate valves, 50mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked),complete all as specified & directed by Engr-in-Charge.
69S&F in repairMNX 9 contacter type for hot waterboiler of 1 L kcal complete all as specified and as directed by Engr-in- charge
70S&F in repair Bimetallic relay of 3 to 5 Amp for hot water boiler of 1 L kcal complete all as specified and as directed by Engr-in- charge
71S&F in repair single phase preventer for hotwater boiler of 1 L kcal complete all as specified and as directed by Engr-in- charge
72S&F in repair control module for hot water boiler of 1 L Kcal complete all as specified and as directed by Engr-in- charge
73S&F in repair testing and commissioning of centrifugal pump set of capacity 3 HP, 3 phase , 415 Volt, 50 HZ & discharge, Head22 to 33 m, size 50x40mm, dischare 4.5 to 2.5 l/s asspecified and directed by Engr-in-Chage.
74Taking down old unsv cable and supply and laying of PVC insulated sheathed6 sqmm, 3 core flate mulfistrand copper conductor cable completeall as specified and directed by Engr-in-Chage.
75S&F in replacement of nozzel for WHB as specified and directed by Engr-in-Chage
76S&F in replacement reducer nipplefor WHB as specified and directed by Engr-in-Cahge.
77S&F in replacement of teflon tape for WHB as specified and directed by Engr-in-Chage.
78M&L for Rewinding of pump motor of capcity 5 HP with super enamled copper and wire of same gauge etcusing best quality of insulationmateruals turning polishing of motor shaft by machining, replacement of bearing -02 Nos including all necessaryrepair work to make the equipment functional, as directed by Engr-in-Chage.
79M&L for Rewinding of pump 3 HP with replacement of different unsv parts including all necessary repair work to make the equipment fully functional, as directed by Engr-in-Chage.Note:- Spare parts to be replaced for this item will be measured and paid separately.
80S&F in repair of following item as required for overhauling/ repairing the centrifugalpump set under srl item No. 08 to 9.
81(a) Impeller
82(b) Pump shaft
83(c)Thrust Bearing
84(d)Water seal
85(e) NRV
86(f) Bushing
87M&L for & cleaning of water tank of capacity 10,000 ltr PVC insulated sintex tank using cleaning solution and de-silting as specifed and dircted by Engr-in-chage.
88S&F in repair star delta starter suitable for 5 HP submersible pump as specifed and directed by Engr-in-chage.
89S&F in repair star delta starter suitable for 20 HP submersible pump as specifed and directed by Engr-in-chage.
90S&F in repair star delta starter suitable for 3 HP submersible pump as specifed and directed by Engr-in-chage.
91M&L in repair K-flex for following MS/ GI pipe 19 thick K-flex insulation including jointing and fixing material such as tape insulation self adhesive with aluminium cladding size of aluminium cladding is not less than 0.1mm
9280 mm dia
9350 mm dia maek: K-flex/ superion
94Taking up or down GI tubing on trench / surfac / wall and connection including cleaning & re-fixing and removalof following size:-
9520 mm & 25 dia
9640 mm & 50 mm dia
97Taking down of unsv pipe of any make and size except 40/50 mm dia.
98S&F steel water tube medium grade galvanised with all fittings including shor lengths, laid in trenchs/ floors / wall with all fittings (such as bends, elbows, Tee, short, pieces,connectors, back nuts, diminishingpieces, caps andplugs, nuions etc.) following size as specified.
9950 mm dia
10040 mm dia
101Taking down of existing MS sheet hot water storage 1500 Ltrs tubulartank from the mounting and checking it forany leakages , damges etc and making on site arrangement for repair of tank by welding with suitable size MS plate making it completely leak proof and refixing the same after wraping with insulation at the existing height and dullyfixing with fastner, nust and boltsetc complete all as specified and directed by Engr-in-chage.
102Supplyand laying of PVC insulatedsheathed multi starndedcopper conductor submersible pump 20 HP cable 10 sqmm , 4 core mulfistrand copper conductor cable complete all as specifiedand directed by Engr-in-charge.
103Repair/ attending break down of boiler to make completely functional in all respect to with out replacing spare parts completeall as specified and as directed. Note: The item includeany typeof breakdown and sundry item cost deemed to be include inthe quoted rate. Note:The work under subject BoQ (item No. 1 to 26) is meant for maint and repair of Boiler in AF Stn 901 SU under GE (AF) Udhampur. The work shall be executed on ground on required basis but being remote station and extreme wheather condition contractor must stand by all the materual and Engineer to rectify the breakdown of Boiler Contractor shall deploysufficient resources to keep smooth workingof boiler in the AF Stn. In addition any breakdownshall be communicated to contractor or his representative by concerned Engr-in-charge / JE E/M through phone call, text message, complaintslip and or in wirting through site order book or through other means. Non complying of attending breakdown by contractor within 24 hoursafter notify the complaint, recovery @ 2000/ per day shall be recovered from contractor"s payment for ech breakdown so notified.
104S&F in repair of GI socket 20/25/40/50 /80 MM complete as per existing size all as specifeid and as directd
105Dismantling Geyser of capacity 25/35 & 50 litrestaking out burnt out partsof geysersand replacement with new parts complete all as as directed by AGE E/M-for following :-(Make : Crompton/Bajaj/Usha/Recold ) Note :- Wornt out parts and spareswill be measured and paid for separately
106S&F in repair to geyser, capacity 25/35 & 50 ltr with under mentioned following items :-
107S&F in repair Inner tank made out of copper/ stainless steel of capacity 25/35 Ltrs.
108S&F in repair Inner tank made out of copper/ stainless steel of capacity 50 Ltrs
109S&F in repair Heating element 2 kw Round type .make- Recold/ Crompton/Bajaj/Usha
110S&F in repair Heating element 1.5 kw.Recold/ Crompton/Bajaj/Usha
111S&F in repair Heating element 1.0 kw.Recold/ Crompton/Bajaj/Usha
112S&F in repair Thermostat switcs
113S&F in repair Appartus platefor 25/35/50 litres capacity
114S&F in repair Heating element 2 kw tikona type.make- Recold/ Crompton/Bajaj/Usha
115S&F in repairs of Heavey Stainless steelgeyser connection pipe304 Grade Graiding for extra connection including taking down complete all as specified and as directed. Make : Usha / Bajaj/ Crompton
116S&F in repairs of Heaveyduty PVC pipe( 36" inchforgeyser connection pipe for extra connection inclluding taking downcomplete all as specified and as directed. Make : Usha / Bajaj/ Crompton
117S&F in repairs base 09 Nuts assembly, compatible to existing geyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete including taking down all as specified and as directed.
118S&F in repairs base 06 Nuts assembly, compatible to existing geyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket including taking down complete all as specified and as directed.
119S&F in repairs GI tubing medium gradeof size 25mm bore ISI marked galvanized with allfittings such as bends, elbows, tees, checknuts, unions nipples etc for cold water pipe line complete all as specified and as directed .
120GI tubing medium gradeof size 20mm bore ISI marked galvanized with allfittings such as bends, elbows, tees, checknuts, unions nipples etc for cold water pipe line complete all as specified and as directed including taking down old.
121S&F in repairs GI tubing medium gradeof size 15mm bore ISI marked galvanized with allfittings such as bends, elbows, tees, checknuts, unions nipples etc for cold water pipe line complete all as specified and as directed.
122Plug type bib taps, cast iron, screwed for iron pipe and fixed of size 15/20 mm bore diacomplete all as specified and as directed.
123S&F in repairsStop valves/angle vale 15mm , cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for ironpipe or for unions and fixed complete all as specified and as directed.
124S&F in repairsStop valves/angle vale 20mm , cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for ironpipe or for unions and fixed
125S&F in repairs plug top 3 pin 15 Amp ISI marked including taking down complete all as specified and as directed. (Make: Anchor/ legrand/indoasian)complete all as specified and as directed.
126M&L in repair of colour Red/Green0.5 wattB22 Holder base complete all as specified and as directed(.Make: Wipro/Bajaj/Surya )
127Supply and fixing Plug socket board with metal socket and plug DP 20 Amp (I Phase ,1 Neutral and earth ) complete including taking down all as specified and as directed.(Make Legrand/ indoasian/ havells)
128Servicing and maintanence forIndoor unit split type Air conditioners of any type / capacity taking down carefully indoor unit servicing and cleaning for all filter, blower, Indoor coil assy, PCB terminal block, frame grill assy incl greasing for blower motor complete withreassembling the same one, inclgood cleaning carefully for out side area used saft cloth with coolin/ shopand testing the same to the entire satisfaction of Engineer-in-Charge, all as directed. Note :- Spares required for repair work will be measured and paid for separately under respective item of BOQ
129Servicing and maintanence forOut door unitforsplitAC and window Air conditioners of any type / capacity servicing , cleaning for all filter, fan blade ,coil assy,terminal block, frame grill assy, coil guard incl greasing for fan motor complete withreassembling the same one, inclgood cleaning carefully for out side area used saft cloth with coolin/ shopand testing the same to the entire satisfaction of Engineer-in-Charge, all as directed. Note :- Spares required for repair work will be measured and paid for separately under respective item of BOQ
130Disconnecting, cutting and takingoutcondensorCoil assy for indoor / outdoor unit find out gas leaking area and brazing work complete and cleaning refitting with testingcomplete all as specified and directed by the Engineer-in-charge. Note :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account.
131Disconnecting, cutting and taking out unserviceable compressor (R-22 gas ) for 1.5 Ton Spilt type ACand replacing with same new compressor including soldering /brazing as required withgas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge. Make : Voltas/Bluestar/LLoyd/Carrier Note :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account.
132Disconnecting, cutting and taking out unserviceable compressor (R-22 gas ) for 2 Ton Spilt type ACand replacing with same new compressor including soldering /brazing as required withgas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge. Make : Voltas/Bluestar/LLoyd/Carrier Note :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account.
133Disconnecting, cutting and taking out unserviceable compressor (R-410a gas ) for 1.5 Ton Spilt type ACand replacing with same new compressor including soldering /brazing as required withgas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge. Make : Voltas/Bluestar/LLoyd/Carrier Note :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account.
134Supply and replacing thermostate switch for 1.5 Ton capacity Air conditioner single phase 240 Volts and 2 Ton Air conditioner 415 Volts, all as specified and directed. Make :- Renutrol/Indfoss or equivalent as approved by GE.
135Supply and replacing control card (PCB) of inner unit of 1.5 Ton AC, all as specified and directed.
136Supply and replacing (eixsiting same size ) Indoor unit blower motorfor 1.5 Ton capacity AC, all as specified and directed.
137Supply and replacing (eixsiting same size ) Indoor unit blower/fan and bushes for 1.5 Ton capacity AC, all as specified and directed.
138Supply and replacing (eixsiting same size ) Indoor unit blower motor for 2.0 Ton capacity AC, all as specified and directed.
139Supply and replacing (eixsiting same size ) Indoor unit blower /fan and bushes for 2 Ton capacity AC, all as specified and directed.
140Supply and replacing (eixsiting same size )outdoor unit blower motorfor 1.5 Ton capacity AC, all as specified and directed.
141Supply and replacing (eixsiting same size )outdoor unit blower /Fan blade withbushes for 1.5 Ton capacity AC, all as specified and directed.
142Supply and replacing (eixsiting same size )outdoor unit blower motorfor 2.0 Ton capacity AC, all as specified and directed.
143Supply and replacing (eixsiting same size )outdoor unit blower/Fan blade with bushes for 2.0 Ton capacity AC, all as specified and directed.
144Supply and replacing Hot and cold valve for 1.5/2.0 Ton capacity AC, all as specified and directed.
145Supply and replacing window AC fan motorfor 1/1.5/2 Ton capacity AC, all as specified and directed.
146Supply and replacing window AC fan motor blade / fanfor 1/1.5/2 Ton capacity AC, all as specified and directed.
147Supply and replacing running capacitor 45 mfd + 10 mfd (combined unit), all as specified and directed by Engineer-in-Charge. Make :- Apcos/Natraj/Tesla/Spark
148Supply and replacing running capacitor 36 mfd + 10 mfd (combined unit), all as specified and directed by Engineer-in-Charge. Make :- Apcos/Natraj/Tesla/Spark
149Supply and replacing starting capacitor 80 mfd - 100 mfd, all as specified and directed by Engineer-in-Charge. Make :- Apcos/Natraj/Tesla/Spark
150Supply and replacing starting capacitor 60 mfd - 80 mfd, all as specified and directed by Engineer-in-Charge. Make :- Apcos/Natraj/Tesla/Spark
151Supply and replacing running capacitor 10 mfd + 10 mfd (combined unit), all as specified and directed by Engineer-in-Charge. Make :- Apcos/Natraj/Tesla/Spark
152Supply and replacing starting relay of 1.5/2.0 Ton window complete all as specified and directed by Engineer-in-Charge. Make :- Renutrol/Indfoss
153Supply and replacing route pipe (copper tube) of size 3/8" dia complete with insulation all as specified and directed by Engineer-in-Charge.
154Supply and replacing route pipe (copper tube) of size 5/8" dia complete with insulation all as specified and directed by Engineer-in-Charge.
155Supply and replacing route pipe (copper tube) of size 1/4" dia complete with insulation all as specified and directed by Engineer-in-Charge.
156Supply and replacing route pipe (copper tube) of size 1/2" dia complete with insulation all as specified and directed by Engineer-in-Charge.
157Supply and replacing filter flap for indoor unit (existing size ) complete set all as specified and directed by Engineer-in-Charge.
158Supply (existing same model)and replacingcodensor outdoor unit complete for 1.5 ton AC all as specified and directed by Engineer-in-Charge.
159Supply(existing same model) and replacing codensoroutdoor unit complete for 2.0 ton AC all as specified and directed by Engineer-in-Charge.
160Supply and refilling of gasR-22/410Ain 2 Ton / 1.5 Ton AC including necessary arrangement for gas filling all as specified and directed by Engineer-in-Charge.
161Supply andrefilling of gas R-410ain 1.5 Ton AC including necessary arrangement for gas filling all as specified and directed by Engineer-in-Charge.
162Supply and replacing thermal overload relay for 1.5/2.0 Ton AC all as specified and directed by Engineer-in-Charge. Make :- Renutrol/Indfoss
163M&L in repair of rewinding of Electronic Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designedlow and high voltage cut out protection for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA.(Make : V- Guard model VWR 400 equivalent Micro tech) all as directed.
164M&L in repair ofrewinding ofElectronic Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designedlow and high voltage cut out protection for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA.(Make : V- Guard model VWR 400 equivalent Micro tech) all as directed.
165M&L in repair ofrewinding of voltage stabilizer of capacity 3 to 5 KVA single phase and rewinding of the main transformer unit with standard copper enamelled wire and making connection (internal), testing the stabilizer to the entire satisfaction of Engineer-in-Charge, all as directed.
166Supply and replacing control card of voltage stabilizer PCB sensor etc.all as specified and directed by Engineer-in-Charge.
167S&F in repairselector switch for input and output voltage all as specified and directed by Engineer-in-Charge.
168S&F in repairIcs and relays all as specified and directed by Engineer-in-Charge.
169Taking out the Refrigerator of capacity 280/310 Ltr and replacement of following parts, reassembly of unit and testing the same to the entire satisfaction of the Engineer-in-Charge.
170S&F in repair of compressor sealed unit including necessary brazing work as required.
171S&F in repair of Thermostate switch suitable for 280/310 Ltrs caapcity refrigerator. Make :- Renutrol/Indfoss or equivalent as approved by GE.
172M&L for refilling of gas as per existing gas in the compressor of refrigerator of any make and capacity with R-134a gas/ carbon free gas.
173S&F in repair of thermal overload relay for 280/310 Ltrs capacity refrigerator. Make :- Renutrol/Indfoss or equivalent as approved by GE.
174Disconnecting the refrigerator of capacity 165/210 ltr and replacement of the following spares required for repairwork including reassembly and testing all as directed.
175S&F in repairof Thermostate switch suitable for 165/210 Ltrs caapcity refrigerator. Make :- Renutrol/Indfoss or equivalent as approved by GE.
176S&F in repairCapilliary tube including brazing work.
177S&F in repairof thermal over load relay.
178S&F in repair of compressor sealed unit including necessary brazing work as required.
179S&F in repair of Ics and relay.
180Taking out Deep Freezer 320 Ltr capacity 230 V AC 50HZ , supply and replacement of following unserviceable parts, reassembling the same after repair and testing on load after completionof job, all as directed.
181S&F in repairof compressor sealed unit including necessary brazing work as required. Make ; Voltas/ blue star/ carrier
182S&F in repair Thermal over load relay. Make :- Renutrol/Indfoss or equivalent as approved by GE.
183Supply and refilling of gasas per existing gas including necessary arrangement for gas filling.
184S&F in repairof Thermostate switch. Make :- Renutrol/Indfoss or equivalent as approved by GE.
185Taking down indoor/outdoor unit of capacity 1.5/2.0 ton capacity after opening electrical connections, securing the refrigerant gas in the compressor and opening refrigeration pipe line safely. Shifting the inddor/outdoor unit for fixing at new places, mounting after drilling hole over out door unit stands, connecting refrigeration pipe line with indoor unit, electrical connection and charging refrigeration gas complete all as specified and directed by Engr-in-Charge. Note :- Additional Refrigerant gas and copper pipe line and insulation will be measured and paid for separately
186S&F in repairof out door unit withcopper condensor compressor , factory made fixingarrangement / stand and required copper tube (3/8")/ (5/8") / (1/4") not less than03 RM complete setfor split type AC 1.5 ton capacity Hot and cool -03 star ,complete all as specified and directed by the Engineer-in-charge.(Make : Voltas/Bluestar/LLoyd/Carrier/ godrej)
187S&F in repairof out door unit with compressorcomplete setfor split type AC 2.0 ton capacity Hot and cool -03 strar, complete all as specified and directed by the Engineer-in-charge.(Make : Voltas/Bluestar/LLoyd/Carrier/ godrej)
188Stands for outdoor unit including drilling hole, nuts bolts , fastners etc complete all as required at site.
189S&F in repairIndoor unit suitable for out dooor unit 1.5 TR, with PCB, Remote operation facilated with mode convertor, Temprature Low & High, Timer, Fan speed controller, , Rlape rotation, outoswing, slip rode, plasticair filter , water drain pipe not less than 03 RM,required 03 core PVC insulated and PVC sheathed cable card size 2.5 sqmm not less than 03 RM all as specified and directed byEngr-in-Charge.
190All as above srl no item No. 88 but suitable for 02 TR outdoor unit.
191Submain wiring with Four single core PVC insulated flexible copper conductor cable FRLS of size 6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6 Sqmm as earth lead in & including surface PVC conduit Heavey duty fixing to wall with clamps complete all as specified anddirected by Engr-in-Charge Note: four runs of 6 sqmm and one run of 6 sqmm cable and one run of PVC conduit shall be measured as one RM.
192S&F in repairMCB single pole 240 volts 5 to 30 amps C" Curve, with rupturing capacity 10 KA, all as specified.
193S&F in repairMCB single pole & neutral 240 volts 20amps C" Curve,with rupturing capacity 10 KA, all as specified.
194S&F in repair MCB TPN 240 volts 32amps C" Curve,with rupturing capacity 10 KA, all as specified.
195S&F in repairof distribution board iron clad, double door with IP-43 1K-09 protection suitablefor MCB TPN as incommer and MCB SP as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link completeall as required at site or directed by Engr-in-Charge.
196S&F in repairSwitch socket out let multi purpose 2 in one, 3 pin, 6 and 16 Amp flush type universal all as specified and directed by the Engineer-in-Charge.
197S&F in repair the (exisitingmodel ) Plug Top 3 pin suitable for 230 Volts 50 HZ 16/20Amps, all as specified.
198S&F in repair to DB pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB including taking downcomplete all as specified and directed by the Engineer-in-charge.
199M&L in repair of defrost timer for domestic refrigerator complete all as specified and directed by the Engineer-in-charge. Make :- Kelvinator/Godrej/Voltas/LG
200S&F in repairof float valve with PVC float ball brass stem & fly nut complete with screwed for iron pipe 15 mm bore complete all as specified and directed by the Engineer-in-charge. Make :- Prayag/Parko or equivalent as approved by GE.
201M&L for rewiring of monoblock pump (Tullu pump) up to 3 HP 230 Volts, single phase, complete including transformer , Two coat painting one coat of red oxide paint along with minor repair of pump such as repair / replacement of bush/ ball bearing, gland rope, impeller setting and rubber gasket etc. all as specified and directed by the Engineer-in-charge.
202S&F in repairof insulation of GI tubing 19mm thick of size 28mm internal dia including jointing material with self adhesive sclvent etc including aluminium claddingcomplete all as specified and directed by Engr-in-Charge.
203Supply only thermic fluid of capacity above 200 degree temp as vaporisation temperaturecomplete all as specified and directed by Engr-in-Charge.
204S&F in repair MCB single pole& Nutral240 Volts 32 to 60 Amps with rupturing capacity 10KAcomplete all as specified and as directed. Make Hager/MDS/Merlin Gerin
205S&F in repair MCB single pole 240 Volts 5 to 30 Amps with rupturing capacity 10KA complete all as specified and as directed. Make Hager/MDS/Merlin Gerin
206S&F in repairMCB Tripplepole 240 Volts 40Amps with rupturing capacity 36KA complete all as specified and as dierected . Make Hager/MDS/Merlin Gerin
207S&F in repair MCB Tripplepole 240 Volts 63Amps with rupturing capacity 36KA complete all as specified and as directed . Make Hager/MDS/Merlin Gerin
208M&L for lagging / insulation of pipe in repair of GI pipe including plumbing etc if required with 25mm thick bounded mineral wool pre sections "SNAP ON" pipe sections of denicity 144 Kg/cum conforming to IS-9842 for 50mm dia GI pipe including chicken mesh wire netting 25 mm gauge, 20mm mesh added and with alluminium foil of .01 mm complete all as specified and directed.
209S&F in repair Gun metal globe or gate valve with iron wheel head screwed both endsfor iron pipes and fixed suitable for 40 mm dia pipe complete all as specified and as directed.
210S&F in repair Gun metal globe or gate valve with ironwheel head screwed both endsfor iron pipes and fixed suitable for 25 mm dia pipecomplete all as specified and as directed.
211S&F in repair MS pipe heavy grade with all fittings laid in floor / trenches / on the wall nominal dia 50 mm as per IS 3589 of 1981 thickness 5.4 mmincluding taking down complete all as specified and directed at site by Engr-in-Charge
212MS pipe heavy grade in repair with all fittings laid in floor / trenches / on the wall nominal dia 25 mm as per IS 3589 of 1981 thickness 5.4 mm including taking down complete all as specified and directed at site by Engr-in-Charge
213S&F in repair of Stop valves,cast copper alloy screwed down high pressure with crutch or butterfly handel screwed both ends for iron pipe or for brass ferrule and fixed for 25 mm bore pipe,complete all as specified and directed at site.
214S&F in repairof Off Load Change over switch 200 Amps with enclosure Rated Voltage 415 AC 50HZ Type 4 Pole complete all as specifed and as directed
215S&F in repair Off Load Change over switch 400 Amps with enclosure Rated Voltage 415 AC 50HZ Type 4 Pole complete all as specifed and as directed
216S&F in repairOff Load Change over switch 100 Amps with enclosure Rated Voltage 415 AC 50HZ Type 4 Pole complete all as specifed and as directed
217S&F in repairof 15/16 Amps switch socket combinationwith PVC box complete all as specified and as diercted .
218Dismentalling ofsquirrel cage induction ofmotor capacity 3 HP ,440 volts 1500 RPM andrewindingwith supper enamelledcopper conductorwire as perexisting gauge and Nos of turnsincluding insulation material and taking out from its orginal position and transportation from site to workshop completeall as directed.
219S&F in repairOFR up to 2500 watt 13fin oil filledradiator for Noiselessheating adjustable thermostateand three heat setting featuring safety tilt and an autothermal shut off to prevent overheating complete all as specified and as diercted .
220S&F in repairof corded electric of 1500 W to 2400 W copper heat pillar portable type room heater 230 volts AC with replacement of twin halogen rods capacity 750 watt / 1000 watt / 1200 watt complete all as specified and directed.
221Maintenance / servicing / repairing / cleaning etc of thermic fluid 4x1 lakh K-cal central air heating plant with air pressure / water pressure / chemicals etc alongwith disconnection all relay / transformer / photo cell/ burner and refixing after repair with testing commissioning etc all as specified and directed by Engr-in-Charge. Each
222Supply only tempareture controllerTC-513 complete all as specified and as diercted
223Supply only Sequence controllerLOA-24171 B27complete all as specified and as diercted .
224Supply only photocell QRB1A complete all as specified and as diercted .
225Supply only Ignition electrode complete all as specified and as diercted .
226S&F in repairof heater /blowerheating rodhalogen type warm white startrack 24&23CM pin type corded electricany size any cap or as per existing size complete all as specified and as directed
227S&F in repair PCB controller - Model - RDF-510,230 volt, AC 50 HZ complete all as specified and as directed. Make-SIEMENS Cat part No - 210308E or its equivalent.
228S&F in repair singlephase permanently lubricated 1/12 HP-62 watt for indoor unit of central Air heating plant complete all as specifiedand as directed. Make : GE motor India PVT Ltd- Model NO 5KCP 29DG686 or its equivalent.
229S&F in repair of solenoid valve suitable for indoor unit of central heating plant complete all as specifiedand as directed.
230S&F in repair SPE echo frame -ignition transformer - COFIE 820-T-120complete all as specifiedand as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail