Tender For Minor Work For Non-Residential Building At Lbs Hospital, Khichripur, Delhi. Sub Head Providing Steel Tower Structure For Exhaust System For 1200 Kva Dg Set As Per Dpcc Norm, delhi-Delhi

Public Works Department-PWD has published Tender For Minor Work For Non-Residential Building At Lbs Hospital, Khichripur, Delhi. Sub Head Providing Steel Tower Structure For Exhaust System For 1200 Kva Dg Set As Per Dpcc Norm. Submission Date for this Tender is 27-12-2022. Diesel Generators Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

35371913
Tender For Minor Work For Non-Residential Building At Lbs Hospital, Khichripur, Delhi. Sub Head Providing Steel Tower Structure For Exhaust System For 1200 Kva Dg Set As Per Dpcc Norm
Open Tender
Indian
Delhi
delhi
27-12-2022

Tender Details

Minor Work For Non-Residential Building At Lbs Hospital, Khichripur, Delhi. Sub Head Providing Steel Tower Structure For Exhaust System For 1200 Kva Dg Set As Per Dpcc Norm

Key Value

Document Fees
Refer document
EMD
INR 114278.0 /-
Tender Value
INR 57.13 Lakhs /-

BOQ Items

Name of Work: Minor work for non-residential building at LBS Hospital, Khichripur, Delhi. (Sub Head: - Providing steel tower structure for exhaust system for 1200 KVA DG Set as per DPCC Norm).
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
2All kinds of soil
3Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials.
4All kinds of soil.
5Open timbering in case of shafts, wells, cesspits, manholes and the like including strutting and shoring complete (Measurements to be taken of the face area timbered):
6Depth not exceeding 1.5 m.
7Depth exceeding 1.5 m but not exceeding 3 m.
8Depth exceeding 3 m but not exceeding 4.5 m.
9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
10Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level :
111:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
12Centering and shuttering including strutting, propping etc. and removal of form for :
13Foundations, footings, bases of columns etc. for mass concrete.
14Suspended floors, roofs, landings, balconies and access platform.
15Lintels, beams, plinth beams, girders, bressumers and cantilevers.
16Columns, Pillars, Piers, Abutments, Posts & Struts.
17Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position & binding all complete upto plinth level.
18Thermo-Mechanically Treated bars of grade Fe-500D or more.
19Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying ,excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge.(Note: Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately.)
20All works upto plinth level
21Supplying & fixing of 8 nos. foundation bolt of size 1200mm long x 25mm dia along with anchor plate of 1mtr x 1mtr x 10mm thick etc. as required.
22Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all loads including all lifts involved.
23Designing, fabrication, providing, lifting, hoisting & fixing of M.S. welded steel tower duly fabricated with M.S. channel, M.S. angle, M.S. plate, M.S. Flats suitable for supporting 300 mm dia 30 Mtr. height exhaust pipe of DG Set including painting etc. complete as required.
24Designing, fabrication, providing, lifting, hausting & fixing of 300mm dia welded black steel pipe made from 5mm thick M.S. Sheet conforming to IS:3589 (with neccessory clamps, vibration issolators & fittings but excuding valves)for exhaust piping of D.G.Set duly insulated with 50 mm thick insulation of minimum 80 kg per cubic meter density resin bounded fibre glass/mineral Wool/Rockwool covered with wire mesh & finally applying 0.63 mm thick aluminum sheet cladding etc. complete as required as per specifications.
25SITC of 6watt nominal rating LED aviation light on the existing steel tower i/c connections, testing etc. asrequired.
26Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
27Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
28Providing and fixing 25mmx5mm G.I. strip on surface or in recess for connections etc. as reqd.
29Providing & fixing of lighting conductor finial made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.
30Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
31Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)
32Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
33Supplying, laying & fixing of 3 X 2.5 Sq.mm.PVC sheathed and PVC insulated/XLPE copper cunductor armoured power cable of 1.1 KV grade on the existing steel structure etc. as required.
34Supplying & laying of various size of PVC sheathed and PVC insulated/XLPE aluminium conductor armoured power cable of 1.1 KV grade in the existing masonry open duct etc. as required.
353.5x400 Sqmm
363.5x300 Sqmm
373.5x185 Sqmm
38Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
393.5x400 Sqmm
403.5x300 Sqmm
413.5x185 Sqmm
42Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
433.5x400 Sqmm
443.5x300 Sqmm
453.5x185 Sqmm