| 1 | De-sludging/cleaning completely of solid/liquid sludge etc manually from inside the soak pit of field flush latrine and removal of sludge to a distance not exceeding 100 meters and depositing in a excavated pit of appropriate size as directed and filled up with earth in each layers of 30 cm thick including spreading bleaching powder and including taking out manhole cover slab for cleaning and resetting after cleaning complete as specified and directed.Note :- (i) Earth to be filled over the pit shall be filled after sufficient absorption of liquid and size of pit shall be made accordingly.(ii)To avoid any health hazard orspreading of any foul gas, bleaching powder shall be spread as directed by the Engineer-in-charge.Cost of supply of bleaching powder, spreading bleaching powder and excavating the earth pit and fillingof earth etc shall be deemedto be included in the rate quoted under this item . |
| 2 | Excavating over areas, n exc 1.5 m deep and getting out in hard/dense soil complete all as specified and directed. |
| 3 | Excavating over areas exc 1.5 m andn exc 3m deep and getting out in hard/dense soil complete all as specified. |
| 4 | M&L for PCC 1:3:6 type C-2 (Using 40mm gradedcrushed stone aggregate) as in cement concrete in foundations filling and mass concretecomplete all as specified and directed. |
| 5 | M&L Sand filling as in back filling under floors or in foundation including watering and consolidation complete all as specified and directed. |
| 6 | Removing excavated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed. |
| 7 | S&F Modular Septic Tank of Capacity 9500 Ltrs (30-50 Users) (plastic septic tank) with inlet/outlet sizes of 160mm, 2 domed ends coupled type includng all accessoried and lowering into position and fixed to inlet and outlet pipes complete all as per manufacturer instructions and directed by Engineer-in-Charge. Make:- Supreme/ Sintex Plastics/ Aqua tech. |
| 8 | M&L for Brick work with sub class \"B\" bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed by Engineer in Charge |
| 9 | M&L for Brickwork with sub-class `B’ bricks in one and half brick thick honey comb walling built in cement mortar 1:4 complete all specified and directed by Engineer in Charge . |
| 10 | M&L for RCC M25 (Design mix) inslabs supported on walls, beams and column in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 11 | Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (horizontal or sloping for flat) complete all as specified and as directed. |
| 12 | S&F mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 13 | M&L for Loose filling with broken bricks aggregate of gauge 80 to 150 mm in soakage wells complete all as specified and as directed. |
| 14 | S&F CI manhole covers medium grade 600 mm dia complete all as specified and as directed. |
| 15 | M&L for 150mm internal dia ofsalt glazed stone ware drain pipes laid in trenches and jointed complete all as specified and as directed. |
| 16 | S&F PVC (SWR) 110 mm dia pipes single socketed in any length with rubber ring joints laid in trenches or in floor complete all as specified and as directed. |
| 17 | S&F 150mm Internal Dia DWCPE pipes (SN-8) pipe ISI Marked laid in trenches and jointed complete all as specified and as directed. |
| 18 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 150mm internal dia pipes complete all as specified and as directed. |
| 19 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces inCM 1:4 surface finished even and smooth without using extra cement complete all as specified and directed. |
| 20 | M&L for precast RCC 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as in cover slabsand set incement mortar 1:6 including providing necessary form work and mould complete as specified and directed. |
| 21 | M&L for Cleaning of WC, Urinal, inspection chamber, gully trap/ floor trap by manually and rod including removal of sludge and other foreign materials as described in item no 1.00 here in before complete as specified and directed. |
| 22 | S&F in repair vitreous china wash down water closet pan (Pedestan pattern), white (excluding flushing cistern & flush pipe) including all fittings complete as specified and directed.. |
| 23 | S&F in repairs vitreous china Squatting pan \"ORISSA\"pattern of size 580x440mm white, with integral foot rests and accessories (excluding flushing cistern & flush pipe)including provisioning of lime concrete bedding complete as specified and directed. |
| 24 | S&F in repairs PVC valve less, syphonic action type, flushing cistern low level, 10 liter capacity with it\"s complete accessories, fixed complete including connection to water pipe and PVC 32mm dia flush pipe etc complete as specified and directed. |
| 25 | S&F Health faucet (ABS Body) mild steel chormium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified & directed by Engineer-in-Charge. |
| 26 | S&F Modular Septic Tank of Capacity 5500 Ltrs (20-30 Users) (plastic septic tank) with inlet/outlet sizes of 160mm, stand alone type includng all accessoried and lowering into position and fixed to inlet and outlet pipes complete all as per manufacturer instructions and directed by Engineer-in-Charge. Make:- Supreme/ Sintex Plastics/ Aqua tech. |
| 27 | Excavating in trenches n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil all as specified and directed. |
| 28 | All as per item No.27 above, but depth exc 1.5m n exc 3.0m. |
| 29 | M&L for cement concrete 1:3:6 type C-2 (Using 40mm gradedcrushed stone aggregate) as in foundations filling and mass concretecomplete all as specified and directed. |
| 30 | Demolition and breaking up drain pipes PVC SWR in any position including fittings like bends and tee etc complete all as specified and directed. |
| 31 | M&L Providing PCC 1:2:4 Type B-1(using 20mm greded crushd stone aggregate) as in coping etc.including necessary form workcomplete all as specified and as directed. |
| 32 | S&F in repairs two way bib cock with wall flange chromium plated with crutch or butterfly handle screwed down screwed for iron pipe 15 mm bore and fixed complete all as specified and as directed. |
| 33 | S&F 110 mm bore PVC (SWR) bends any radius complete all as specified & directed. |
| 34 | S&F 75 mm bore PVC (SWR) bends any radius complete all as specified & directed. |
| 35 | S&F 110 mm bore PVC (SWR) junction single, (single T), equal or unequal with door complete all as specified & directed. |
| 36 | S&F 75 mm bore PVC (SWR) junction single, (single T), equal or unequal with door complete all as specified & directed. |
| 37 | S&F PVC grease trap 100 ltrs capacity consisting of removable bucket inlet and outlet connections as recommended by the manufacturer of make: supreme Industries Ltd/Sintex |
| 38 | Surface dressing n exc 15cm deep in hard/dense soilcomplete all as specified and directed. |
| 39 | M&L 75mm thick PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregated) as in sub base complete all as specified. |
| 40 | M&L PCC 1:2:4, type B0 (using 12.5mm graded crushed stone aggregate) as in copings, kerbs and the like incl weathering, slightly rounded or chamfered angles and throating, as directed including necessary form workcomplete all as specified and as directed |
| 41 | M&L 60mm thick Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS 15658- 2006 M-35 grade, laid as directed to any shape. Complete all as specified and as directed |