Public Works Department-PWD has published Tender For Supply Installation Testing Commissioning Of Ac System With Allied Electrical Installation Work At Geography Lab, Statistics Laboratory And Atal Tinkering Lab In Hooghly Collegiate School-Electrical Installation Work. Submission Date for this Tender is 02-01-2023. Laboratory Equipment Tenders in hooghly West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

35366872
Tender For Supply Installation Testing Commissioning Of Ac System With Allied Electrical Installation Work At Geography Lab, Statistics Laboratory And Atal Tinkering Lab In Hooghly Collegiate School-Electrical Installation Work
Open Tender
Indian
West Bengal
hooghly
02-01-2023

Tender Details

Supply Installation Testing Commissioning Of Ac System With Allied Electrical Installation Work At Geography Lab, Statistics Laboratory And Atal Tinkering Lab In Hooghly Collegiate School-Electrical Installation Work - 1 Distribution Wiring In 2 X 22 / 0.3 ( 1.5 Sqmm ) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire ( Brand Approved By Eic ) In 20Mm Size Pvc Rigid Conduit Fr ( Precision Make ) , With 1X22 / 0.3 ( 1.5 Sqmm ) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire For Ecc, To Light / Fan / Call Bell Points With Modular Type Switch ( Brand Approved By Eic ) Fixed On Modular Gi Switch Board With Top Cover Plate And 2 No. Suitable Size “Ph & N” Copper Bar & Earthing Attachment Fixed On Wall Incl. Mending Good Damages To Original Finish. 1.1 Average Run 11 Mtr [ 1 ( F ) / E-24 ] ( For Atal Tinkering Lab ) 2 Distribution Wiring In 1.1 Kv Grade 22 / 0.3 ( 1.5 Sqmm ) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire ( Brand Approved By Eic ) In 20Mm Size Pvc Rigid Conduit Fr ( Precision Make ) , With 1.1 Kv Grade 1 X 22 / 0.3 ( 1.5 Sqmm ) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire As Ecc, To 6A 3 Pin Modular Type Plug Socket & Switch ( Brand Approved By Eic ) As Per Gs. 2.1 On Board [ 3 ( A ) / E- 24 ] 3 Supply & Fixing 240 V, 4 Nos. 6 A, 3 Pin Modular Type Plug Socket With 4 Nos. 6A Modular Type Switch ( Brand Approved By Eic ) , 16A Modular Switch Type Mcb ( C-Curve ) And Indicator Without Plug Top On 2 Row 18 Module Gi Modular Type Switch Board With 2 Row 18 Module Top Cover Plate Flushed In Wall Incl. S&F Switch Board And Cover Plate And Making Necy.Connections With Pvc Cu Wire And Earth Continuity Wire Etc. [ 12 / E-18 ] 4 Supplying & Fixing Gi Modular Switch Board Of The Following Sizes Complete With Three No. Suitable Size Copper Bar With Holes ( For Ph, N & E ) Fixed On Bakelite / Hard Rubber Insulator Over The Ms Welded Chairs Incl. Top Cover Flushed In Wall For Housing The Board After Cutting The Brick Wall Incl. Making Earthing Attachment, Painting And Mending Good Damages To Building Works [ 1 ( B ) / E-17 ] 4.1 6 Module 5 Supply & Fixing 240 V 6 A Modular Type Switch ( Brand Approved By Eic ) On Existing Gi Modular Type Switch Board Having Top Cover Plate And Making Necessary Connections As Required [ 3 ( A ) / E-17 ] 6 Supply & Fixing 240 V 16 A Modular Key Type Switch ( Brand Approved By Eic ) On Gi Modular Type Switch Board Having Top Cover Plate And Making Necessary Connections As Required [ 3 ( B ) / E-17 ] 7 Supply & Fixing 240 V, 6A, 5 Pin Modular Type Plug Socket ( Brand Approved By Eic ) , Without Switch & Plug Top, On Existing Gi Modular Type Switch Board With Top Cover Plate And Making Necy. Connections With Pvc Cu Wire And Earth Continuity Wire Etc [ 4 ( A ) / E-17 ] 8 Supply & Fixing 240 V, 16 A, 3 Pin Modular Type Plug Socket ( Brand Approved By Eic ) , Without Plug Top And Switch, On Existing Gi Modular Type Switch Board With Top Cover Plate And Making Necy. Connections With Pvc Cu Wire And Earth Continuity Wire [ 4 ( B ) / E-17 ] 9 Supply & Fixing 240 V, 25 A, 3 Pin Modular Type Plug Socket ( Brand Approved By Eic ) , Without Plug Top And Switch With 2 Module Gi Modular Type Switch Board With Top Cover Plate Flushed In Wall And Making Necy. Connections With Pvc Cu Wire And Earth Continuity Wire Etc. [ 5 ( A ) / E-17 ] 10 Supply & Fixing 240 V, 25 A, Modular Type Starter ( Brand Approved By Eic ) With 25A Modular Switch Type Dp Mcb ( Ccurve ) And 4 Module Gi Modular Type Switch Board With 4 Module Top Cover Plate Flushed In Wall Incl. S&F Switch Board And Cover Plate And Making Necy. Connections With Pvc Cu Wire And Earth Continuity Wire Etc. [ 17 / E-19 ] 11 Supply & Fixing 240 V, 25 A, 3 Pin Modular Type Plug Top With Indicator ( Brand Approved By Eic ) & Necy. Connections. [ 5 ( B ) / E-17 ] 12 S & F, 415V, 3 Phase, Mug-6, Dol Starter With Over Load Relay Range ( 9-14 ) Amp Make:- L & T 13 Supplying And Fixing Mcb Ss Enclosure With Ip-20 / 30Protection, Powder Coated Provision For Two / Four Pole Mcb, Concealed In Wall After Cutting The Wall & Mending Good The Damages To Original Finish Incl. Painting, Connection & Provision For Earthing Attachment 13.1 4 Way [ 11 / D-9 ] 14 Supplying And Fixing Double-Door Spn Mcb Distribution Board With Ip-42 / 43 Protection, Concealed In Wall As Per Gs. 14.1 2+12 Way [ Siemens Enclosure ( 8Gb32102rc14 ) / Schneider Enclosure- ( A9hsnd12 ) Or Equivalent Model Of Legrand / Crabtree ] As Per Direction Of Eic. [ 13 / D- 9 & D-10 ] 15 Supplying And Fixing Double Door Horizontal Tpn Mcb Distribution Board With Ip-42 / 43 Protection, Concealed In Wall As Per Gs. ( Make - Legrand / Schneider / Crabtree ) As Per Direction Of Eic. ) 15.1 6Way Make - Legrand, Enclosure-607716 / Schneider, Enclosure-A9htnd06 / Crabtree, Enclosure- ( Dcdkthodcw06 ) Or Equivalent Cat Of Siemens / L&T As Approved E.I.C As Approved By E.I.C [ 14 / D- 10 ] 15.2 4 Way Make - Legrand, Enclosure-607715 ) / Schneider, Enclosure- ( A9htnd04 ) / Crabtree, Enclosure- ( Dcdkthodcw04 ) [ 14 / D- 10 ] 16 Supplying And Fixing Double Door Vertical Tpn Mcb Distribution Board For Mccb Incomer With Ip-42 / 43 Protection, On Angle Iron Frame On Wall As Per Gs As Per Direction Of Eic. 16.1 8 Way ( Up To 160 A ) Make - Legrand, Enclosure 607914 / Schneider-Enclosure-A9hvd08m / L&T, Enclosure- ( Ltvd08mgn ) [ 15 / D- 11 ] 17 Supplying And Fixing 240 / 415 V Mcb Isolator On Din Rail Of Existing Dbs And Necessary Connection As Per Gs [ Make-Legrand / Schneider / Siemens / Crabtree / L&T ) As Per Direction Of Eic. ] 17.1 40 A Dp [ 6 / D- 5 ] 17.2 40 A Fp [ 6 / D- 5 ] 17.3 63 A Fp [ 6 / D- 5 ] 18 Supplying And Fixing 415 V Four Pole Mccb Of Breaking Capacity 25Ka / 35Ka In Existing Vertical Dbs Including Necessary Connection As Per Gs. [ Make - Legrand / Schneider / L&T ) As Per Direction Of Eic. ] 18.1 160 A [ 10 / D-8 ] 19 Supplying And Fixing 240 / 415 V Mcb Of Breaking Capacity 10Ka & C Characteristics On Din Rail Of Existing Dbs And Necessary Connectionas Per Gs [ Make-Legrand / Schneider / Siemens / Crabtree / L&T ) As Per Direction Of Eic. ] 19.1 6-32 Sp [ 7 / D- 6 ] 19.2 32 A Tp [ 7 / D- 6 ] 19.3 63 A Tp [ 7 / D- 6 ] 20 Supplying And Fixing 415V, Tpn Sfu With Sheet Steel Enclosure On Flat Iron / Angle Iron Frame On Wall With Nuts Bolts Etc Incl. S & F 3 Nos. Din Type Hrc Fuse As Per Rating. 20.1 160A Tpn Sfu [ 4 ( A ) / D-3 ] 20.2 63A Tpn Sfu [ 4 ( A ) / D-3 ] 21 Supplying And Fixing Double Door Sheet Steel ( 16Swg ) , Powder Coated Cable End Box For Tpn Db Horizontal / Vertical Enclosure With Ip-42 / 43 As Per Gs 21.1 4Way ( Horizontal ) [ 16 / D-12 ] 21.2 6 Way ( Horizontal ) [ 16 / D-12 ] 21.3 8 Way ( Vertical ) [ 16 / D-12 ] 22 S & F 3 Phase Timer Box Made Of 14 Swg Ms Sheet ( Size Approx– 400 X 350 X 175Mm ) With Powder Coated Synthetic Paint Incl. Hinged Type Ms Door , Inter Locking System Consisting The Following Materials : 1 ) S & F 24 Hr. Timer ( L & T , J648b1 / Legrand ) – 1 No. 2 ) S & F 440 Volt 40A 3P Contactor ( L & T, Ml – 3 , Ss90721 ) – 1 No. 3 ) 6 Amp Auto Mannual Toggle Switch – 1 No. ( L &T ) 4 ) Indicating Lamp B & G ( L&T ) – 2 Nos. 5 ) 440V, 40A, 10Ka, C Series Tp Mcb ( L&T / Legrand ) On Din Rail For Incoming- 1No. 6 ) 100A Capacity 4W Brass Stud Type Connector On Frp Chair For I / C & O / G- 2Nos All Control Circuit Wiring Would Be Made By 1X1.5 Sqmm Stranded Cu Wire ( Frls ) And The I / G & O / G Circuit With 1X6sqmm Copper Wire Maintaining Colour Code Incl Taping, Socketing To Complete The Work. The Box Should Be Fixed On Wall With Suitable Size Of Flush Nut And Necy. Connection. ( For Controlling Three Phase Concealed Split Ac ) 23 S&F Of 250V Timer Db ( Equivalent To 12 Way Spndb In Size ) With Double Door Sheet Steel Enclosure, Neutral Bar, Din Rail, With Lp43 Protection Comprises With 25 A Dp Mcb ( C-Curve 10Ka ) And 1 No 24 Hr Analog Time Switch And 1 No 25 A Power Contactor Complete With Internal Wiring With Suitable Size Of Copper Wire Including 1 No Toggle Switch And Led Indicator And Earthing Attachment As Per Direction Of Eic ( For Controling Single Phase Split Ac Machines ) 24 S / F Stainless Steel Water Proof Looping Cable Box Of Size 200X150x100mm Having Hinged Top Cover With Rubber Gasket Lining, Railway Type Mechanical Locking Anangement, Earthing Terminal With Lug Etc. Of The Following Size As Indicated Above, Comprising Of One Din Rail For Fixing Of Fp Isolator Inside It. 25 Supplying And Drawing 1.1 Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Single Core Stranded Copper Wire Of The Following Sizes In The 19Mm / 25Mm Prelaid Polythene Pipe / Pvc Rigid Conduit As Per Gs. 25.1 3 X ( 1.5 Sqmm ) For ( 1*5A+ 1*5A ) Board [ 1 ( B ) / E- 9 ] 25.2 2X ( 2.5 Sqmm ) +1X ( 1.5 Sqmm ) [ 1 ( S ) / E-9 ] ( For 1*6A+1*16A Socket, 4X6a Computer Board ) 25.3 2X ( 4 Sqmm ) +1X ( 2.5 Sqm [ 1 ( V ) / E- 9 ] ( For 04 Nos. 2 Tr Ac ) 25.4 2X ( 6 Sqmm ) +1 X ( 4 Sqmm ) [ 1 ( Y ) / E- 9 ] ( From Htpndb To Spndb ) 25.5 4X ( 6Sqmm ) +2X ( 4 Sqmm ) [ 1 ( A11 ) / E- 9 ] ( For 4 Nos. 5 Ton Ac ) 25.6 4X ( 16 Sqmm ) +2X ( 10 Sqmm ) [ 1 ( G1 ) / E- 9 ] ( From To Vtpn To Htpn ) 26.00 Supplying And Fixing Pvc Rigid Conduit Fr [ Precision Make ] Of Following Sizes On Wall, Ceiling With Saddles And Other Accessories As Required And Mending Good Damages To Building Works 26.10 20 Mm Size [ 7 ( A ) / E- 16 ] 26.20 25 Mm Size [ 7 ( B ) / E- 16 ] 27.00 Cutting Channel Of Required Size On Masonry Wall By Electric Operated Cutting Machine Incl. Supplying & Fixing Of Heavy Gauge Polythene Pipe Of Following Diameter As Per Gs. 27.10 19 Mm Dia 3 Mm Thick [ 6 ( A ) / E- 3 ] 27.20 25Mm Dia 3 Mm Thick [ 7 ( A ) / E- 3 ] 28.00 Supplying & Fixing Sheet Metal Inspection Box ( 16 Swg ) Of The Following Sizes Flushed In Wall By Housing The Same After Cutting Brick Wall Incl. Making Earthing Attachment, Painting And Mending Good Damages To Building Works 28.10 150 Mm X 100 Mm X 65 Mm [ 11 ( B ) / E-4 ] 28.20 200 Mm X 150 Mm X 65 Mm [ 11 ( D ) / E-4 ] 29.00 Supply & Fixing Bakelite / Perspex Top Cover On Existing Switch Board By Brass Screws After Making Housing For Switch By Cutting Bakelite / Perspex Cover And Making Necessary Connections As Required 29.10 150 Mm X 100 Mm X 65 Mm [ 12 ( B ) / E-4 ] 29.20 200 Mm X 150 Mm X 65 Mm [ 12 ( D ) / E-4 ] 30.00 S & F Solderless Copper Socket By Crimping Of Copper Wires. 30.10 A ) 1.5 Sq Mm 30.20 B ) 2.5 Sq Mm [ 9 ( I ) / F-5 ] 30.30 C ) 4 Sq Mm [ 9 ( Ii ) / F-5 ] 30.40 D ) 6 Sq Mm [ 9 ( Iii ) / F-5 ] 30.50 E ) 10 Sq Mm [ 9 ( Iv ) / F-5 ] 30.60 F ) 16 Sq Mm [ 9 ( V ) / F-5 ] 31 Supply Of 4 / 3.5 / 2 Core Xlpe Insulated & Sheathed Armoured Aluminium Conductor Cables For Working Voltage Up To 1100 Volts Of Following Sizes [ Make- Nicco / Gloster / Kei / Havells As Approved By E.I.C ] 31.1 3 Core 10 Sq.Mm ( For Gong Bell ) 31.2 4 Core 35 Sq.Mm ( From Panel To Htpndb ) 31.3 4 Core 70 Sq.Mm ( From Panel To Normal Vtpn ) 32 Laying Of One No. Cable Upto 35 Sqmm In Underground Trench 460Mm Wide X 760 Mm Average Depth, With Brick Protection On The Top Of The Cable With 8 ( Eight ) Nos. Bricks Per Metre, Including Filling The Space Between The Brick & Cable And Also The Trenchwith Shifted Soil, Leveling Up And Restoring Surface Duly Rammed [ 1 ( A ) / F2 ] 33 Laying Of Cable Upto 3 / 4 Core 25 Sqmm On Wall / Surface Incl. S & F Ms Saddles With Earthing Attachment In 10 Swg Gi ( Hot Dip ) Wire, Making Holes Etc. As Necy. Mending Good Damages And Painting [ 2 ( B ) / F1 ] 34 Laying Of Cable From 3 / 3½ Core 35 Sqmm To 50 Sqmm On Wall / Surface Incl. S & F Ms Saddles With Earthing Attachment In 2 X 10 Swg Gi ( Hot Dip ) Wire, Making Holes Etc. As Necy., Mending Good Damages And Painting [ 2 ( C ) / F1 ] 35 Laying Of Cable As Below, After Cutting Floor / Pavement / Wall / And Making Holes Incl., Embedding The Cable At An Average Depth Asbelow And Mending Good The Damages To Original Finish Incl. Removing The Rubbish 35.1 From 2.5 Sqmm To 35 Sqmm At An Average Depth Of 75 Mm In Floor / Pavement / Wall Etc. ( 5 ( I ) / F3 ) 36 Supply & Fixing Of Perforated Gi Cable Tray With Perforation Not More Than 17.5% Suspended From Ceiling Incl. S&F Gi Connector, 6Mm Dia Ms Suspender, Bolts & Nuts, Steel Fastener Etc. As Required Of The Following Size. Incl. Al Painting Of Ms Support. 36.1 200X50x1.25Mm ( 18Swg ) [ 34 ( A ) ( Ii ) / D-14 ] 37 Laying Of Cable As Below, On Existing Cable Tray And Binding With Suitable Size Gi Wire 37.1 From 70Sqmm To 150Sqmm [ 6 ( Ii ) / F-3 ] 38 Supplying & Fixing Medium Gauge Gi Pipe ( Isi-Medium ) Protection With Necessary Fittings As Per Gs & Direction Of Eic. 38.1 32 Mm Dia [ 11 ( B ) / F-6 ] 39 Laying Only Cable Upto 50 Sqmm Through Existing Rcc / Hume / Gi Pipe / Open Masonary Trench For Single, 2, 3, 3½ & 4 Core [ 3 ( A ) / F-1 ] 40 Supplying And Fixing Compression Type Gland Complete With Brass Gland, Brass Ring & Rubber Ring For Dust & Moisture-Proof Entry Of Xlpe / Pvc Armoured Cables As Below : 40.1 3Core 10 Sq.Mm [ 7 ( D ) / F4 ] 40.2 4 Core 35 Sq. Mm [ 7 ( D ) / F4 ] 40.3 4 Core 70 Sq. Mm [ 7 ( D ) / F4 ] 41.00 Finishing The End Of Following Xlpe / Pvc Armoured Cables By Crimping Method Incl. Supplying And Fixing Solderless Socket ( Dowels Make ) , Tapes, Anticorrosive Paste & Jointing Materials : 41.10 3Core 10 Sq.Mm [ 8 ( B ) / F5 ] 41.20 4 Core 35 Sq. Mm [ 8 ( B ) / F5 ] 41.30 4 Core 70 Sq. Mm [ 8 ( B ) / F5 ] 42.00 Fixing Only Single / Twin Fluorescent / Led Light Fitting In The Ceiling Fixed With “L” Type Ms Clamp For Rc Ceiling / Ms Pipe As Per Gs Direction Of Eic [ 17 / C-2 ] 43.00 Fixing Only Single / Twin Florescent Light Fitting Complete With All Accessories Directly On Wall / Ceiling As Per Gs. [ 14D / C-2 ] 44.00 Extra For Suspension Exceeding 25 Cm With S&F Additional 2 No. 20 Mm Dia Ei Conduit ( 14 Swg ) Supports & Necy. Pvc Insulated Wire And Painting Etc. As Required By 2X24 / 0.20 Mm ( 1.5Sqmm. ) Flexible Copper Wire Of 1.10 Mt. Length. [ 16 / C-2 ] 45.00 Supply And Delivery Of Single / Twin Industrial Led Batten Luminaries Incl. Supply Of 1 No. / 2Nos. 18W Led Tube 45.10 Twin Fittings [ Philips Make Cat No. Tmc-501 P1xt-Led 22W P3242 Or Equivalent Make Cg / Bajaj / Wipro / Magik ] Incl. 2 Nos. 18W Master Led Tube ( With 2 Years Warranty 46.00 Supplying & Fixing Iron Beam Fan Clamp Of Two Piece Type, As Per Approved Specification, Fabricated From 40 Mm X 9 Mm Ms Sheet Flat Suitable For Beam Having Flange Upto 150 Mm Wide [ 30 / D14 ] 47.00 S & F Of Ms Down Rod 14 Swg 20 Mm Dia Ms Conduit As Per Gs & Direction Of Eic. [ Ns ] 48.00 Supply & Fixing 240V, Modular Socket ( 2 Module ) Type Fan Regulator ( Step Type ) ( Brand Approved By Eic ) On Existing Modular Gi Switch Board With Top Cover Plate Incl. Making Necy. Connections Etc. [ 10 / E18 ] 49.00 Fixing Only Ceiling Fan Complete With Blades, Canopy, Fork, Rubber Bush Etc As Per Gs [ 21 ( A ) / C-3 ] 50.00 Engraving The Deptt. Number With 10 Mm Lettering On The Body As Per Gs. [ 24 ( A ) / C-3 ] 51.00 Painting Upto 10 Letters Of The Engraved Number With Approved Black / Red Paint As Required As Per Gs [ 26 ( A ) / C-3 ] 52.00 Fixing Only Cabin Fan On Wall / Ceiling By S&F Rag Bolts, Nuts & Washers ( 6 Mm Dia X 62 Mm Long ) Or As Reqd. Incl. S&F 24 / 0.20 Pvc Insulated Flexible Copper Wire 0.5 Mt. Length [ 29 / C-4 ] 53.00 Supply Of Ac Ceiling Fans Of 1200Mm Sweep With Burst-Proof P2 / S3 Capacitor Complete With All Accessories Without Regulator. ( Make - Usha-Striker Or Equivalent Model Of Havells / Cg / Orient As Approved By E.I.C ) 54.00 Supply Of 450Mm Sweep Wall Bracket Fan ( High Speed ) With Metal Body & Blades ( Orient - Wall-Ii Tornado Or Equivalent Cat Of Cg / Epc / Cinni ) With Necessary Wooden Board On Wall With Nuts, Bolts, Washer Etc. ( With 2 Years Warranty Order And Warranty Certificate Should Be Provide ) 55.00 Supply 240 V , 12 Inch Electric Gong Bell ( Reputed Make ) , Material Steel , Silver Color 56.00 Earthing With 50 Mm Dia Gi Pipe 3.64 Mm Thick X 3.04 Mts. Long With Tata-Medium Gi Pipe As Per Gs [ 2 ( A ) / G-1 ] 57.00 Extra For Providing Masonery Enclosure On The Top Of The Earth Electrode Of Overall Size 86.36 Cm X 86.36 Cm X 46 Cm Deep ( Below Ground Level ) Complete With Cemented Brick Work ( 1:6 ) Of 25 Cm Width Duly Plastered With Cement Morter ( Inside ) Cl Hinged Inspection Cover Of Size 36.56 Cm X 35.56 Cm With Locking Arrangement, Gi Reducer Including Drilling Of 46 Nos. 12 Mm Dia Holes On The Gi Pipe. [ 3 ( A ) / G-2 ] 58.00 Excavation Of Soil For Installation Of Earth Electrode And Filling & Ramming. ( For Soft Soil ) [ 1 ( A ) / G-1 ] 59.00 Extra For Treatment Of Soil By Using Salt & Charcoal Or Coke For Plate Electrode [ 3 ( B ) / G-2 ] 60.00 Connecting The Equipments To Earth Busbar Including S & F Solid Gi ( Hot Dip ) Wire Of Size As Below As Per Gs 60.10 No.-10 Swg [ 5 ( A ) ( Iv ) / G-2 ] 61.00 Connecting The Equipments Body To Earth Busbar Including S & F 25 Mm X 6 Mm Galvanised ( Hot Dip ) Ms Flat On Wall / Floor With Gi Saddles As Required And Connection To Equipments Incl. Drilling Holes, With Bolts, Nuts, Washers Etc. [ 5 ( D ) / G-3 ] 62.00 Supplying & Fixing Earth Busbar Of Galvanized ( Hot Dip ) Ms Flat 25 Mm X 6 Mm On Wall Having Clearance Of 6 Mm From Wall Including Providing Drilled Holes On The Busbar Complete With Gi Bolts, Nuts, Washers, Spacing Insulators Etc. As Required [ 4 ( A ) / G-2 ]

Key Value

Document Fees
Refer document
EMD
INR 15922.0 /-
Tender Value
INR 7.96 Lakhs /-

BOQ Items

Name of Work:SITC of AC system with allied E.I work at Geography lab, statistics laboratory and Atal Tinkering lab in Hooghly Collegiate School----Electrical Installation work.
Sl. No. Item Description
1Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit "FR" (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish.
2Average Run 11 Mtr [1(f)/ E-24 ] ( for Atal Tinkering lab)
3Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit "FR" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) as per GS.
4On Board[3 (a) / E- 24]
5Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc. [ 12/E-18 ]
6Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works[1(b)/E-17]
76 Module
8Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required [3(a)/E-17]
9Supply & Fixing 240 V 16 A Modular key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required [3(b)/E-17]
10Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc[4(a)/E-17]
11Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire [4(b)/E-17]
12Supply & Fixing240 V, 25 A, 3 pin Modular type plug socket(Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plateflushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.[ 5(a) / E-17]
13Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[17/E-19]
14Supply & Fixing240 V, 25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. [5(b) / E-17]
15S & F, 415V, 3 phase, MUG-6, DOL Starter with over load relay range (9-14) Amp Make:- L & T
16Supplying and fixing MCB SS enclosure with IP-20/30protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment
174 Way [11/D-9]
18Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.
192+12 Way [Siemens Enclosure(8GB32102RC14)/ Schneider Enclosure-(A9HSND12) or equivalent model of Legrand / Crabtree] as per direction of EIC. [ 13 / D- 9 & D-10 ]
20Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand/ Schneider/ Crabtree) as per direction of EIC. )
216Way Make - Legrand, Enclosure-607716/Schneider, Enclosure-A9HTND06/Crabtree, Enclosure- (DCDKTHODCW06) or equivalent cat of Siemens/L&T as approved E.I.C as approved by E.I.C[ 14 / D- 10 ]
224 Way Make - Legrand, Enclosure-607715)/ Schneider, Enclosure- (A9HTND04) / Crabtree, Enclosure- (DCDKTHODCW04)[14 / D- 10 ]
23Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wallas per GS as per direction of EIC.
248 Way ( Up to 160 A )Make - Legrand, Enclosure 607914/Schneider-Enclosure-A9HVD08M/L&T,Enclosure- (LTVD08MGN)[15 / D- 11 ]
25Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ]
2640 A DP [ 6 / D- 5 ]
2740 A FP [ 6 / D- 5 ]
2863 A FP [ 6 / D- 5 ]
29Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kAin existing Vertical DBs including necessary connection as per GS. [Make - Legrand / Schneider/L&T) as per direction of EIC.]
30160 A [10/D-8]
31Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. ]
326-32 SP[ 7 / D- 6]
3332 A TP[ 7 / D- 6 ]
3463 A TP[ 7 / D- 6 ]
35Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.
36160A TPN SFU[4 (a)/D-3]
3763A TPN SFU[4 (a)/D-3]
38Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 as per GS
394Way (Horizontal) [16/D-12]
406 Way (Horizontal) [16/D-12]
418 Way ( vertical ) [16/D-12]
42S & F 3 phase timer box Made of 14 SWG MS sheet (size approx– 400 X 350 X 175mm)with powder coated synthetic paint incl. hinged type MS door , inter locking system consisting the following materials : 1) S & F 24 Hr. timer (L & T , J648B1/Legrand) – 1 no. 2) S & F 440 Volt40A3P contactor (L & T, ML – 3 , SS90721) – 1 no. 3) 6 amp auto mannual toggle switch – 1 no. (L &T) 4) Indicating lamp B & G (L&T) – 2 nos. 5) 440V, 40A, 10KA, C series TP MCB (L&T/ Legrand)on din rail for incoming- 1no. 6) 100A capacity 4W Brass stud type connector on FRP chair for I/C & O/G- 2nos All control circuit wiring would be made by 1x1.5 sqmm stranded Cu wire(FRLS) and the I/G & O/G circuit with 1x6sqmm copper wire maintaining colour code incl taping, socketing to complete the work.The box should be fixed on wall with suitable size of flush nut and necy. connection. (for controlling three phase concealed split AC )
43S&F of 250V timer DB (equivalent to 12 way SPNDB in size) with double door sheet steel enclosure, neutral bar, din rail, with lP43 protection comprises with 25 A DP MCB (C-curve 10ka) and 1 no 24 hr analog time switch and 1 no 25 A power contactor complete with internal wiring with suitable size of copper wire including 1 no toggle switch and LED indicator and earthing attachment as per direction of EIC ( for controling single phase Split AC Machines)
44S/F Stainless Steel water proof looping cable box of size 200x150x100mm having hinged top Cover with rubber gasket lining, railway type mechanical locking anangement, earthing terminal with lug etc. of the following size as indicated above, comprising of one din rail for fixing of FP Isolator inside it.
45Supplying and Drawing 1.1 KV single core stranded "FR" PVC insulated & unsheathed single core stranded copper wire of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS.
463 x(1.5 sqmm)for (1*5A+ 1*5A) board [1(b) / E- 9 ]
472x(2.5 sqmm)+1x(1.5 sqmm)[ 1(s) / E-9 ] (for 1*6A+1*16A Socket, 4x6Acomputer Board)
482x(4 sqmm)+1x (2.5 sqm[ 1(v) / E- 9 ] (for 04 nos. 2 Tr AC)
492x(6 sqmm)+1 x (4 sqmm) [ 1(y) / E- 9 ](From HTPNDB to SPNDB)
504x(6sqmm)+2x(4 sqmm) [ 1(a11) / E- 9 ] (for 4 nos. 5 ton AC)
514x(16 sqmm)+2x (10 sqmm) [ 1(g1) / E- 9 ] (from to VTPN to HTPN)
52Supplying and fixing PVC Rigid Conduit "FR" [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works
5320 mm size[ 7(a)/ E- 16 ]
5425 mm size[ 7(b)/ E- 16 ]
55Cutting Channel of required sizeon masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipeof following diameteras per GS.
5619 mm dia 3 mm thick[ 6 (a)/ E- 3 ]
5725mm dia 3 mm thick [ 7 (a)/ E- 3 ]
58Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works
59150 mm x 100 mm x 65 mm[11(b)/E-4]
60200 mm x 150 mm x 65 mm[11(d)/E-4]
61Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required
62150 mm x 100 mm x 65 mm[12(b)/E-4]
63200 mm x 150 mm x 65 mm[12(d)/E-4]
64S & F solderless Copper socket by crimping of Copper wires.
65a)1.5 sq mm
66b) 2.5 sq mm[9(i) / F-5]
67c) 4 sq mm [9(ii) / F-5]
68d) 6 sq mm [9(iii) / F-5]
69e) 10 sq mm [9(iv) / F-5]
70f) 16 sq mm[9(v) / F-5]
71Supply of4/3.5/2 Core XLPEInsulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make- Nicco/Gloster/KEI/Havells as approved by E.I.C]
723 Core 10 Sq.mm (for Gong bell)
734 Core 35 Sq.mm (from panel to HTPNDB)
744 Core 70 Sq.mm (from panel to Normal VTPN)
75Laying of one No. cable upto 35 sqmm in underground trench 460mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed [1(a)/F2 ]
76Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [2(b)/F1 ]
77Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting [2(c)/F1 ]
78Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth asbelow and mending good the damages to original finish incl. removing the rubbish
79From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.(5(i)/f3)
80Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.
81200x50x1.25mm (18SWG)[ 34 (a )(ii)/D-14 ]
82Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire
83From 70sqmm to 150sqmm [ 6 (ii) /F-3 ]
84Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS & direction of EIC.
8532 mm dia [11(b)/F-6]
86Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core [3(a)/F-1]
87Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
883Core 10 Sq.mm[7(d)/F4 ]
894 Core 35 Sq. mm[7(d)/F4 ]
904 Core 70 Sq. mm[7(d)/F4 ]
91Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
923Core 10 Sq.mm [8(b)/F5]
934 Core 35 Sq. mm[8(b)/F5]
944 Core 70 Sq. mm[8(b)/F5]
95Fixing only single/twin fluorescent/LED light fitting inthe ceilingfixed with “L” type MS clamp for RC ceiling / MS pipe as per GS direction of EIC [ 17/C-2 ]
96Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS.[ 14d/C-2 ]
97Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [16/C-2]
98Supply and delivery of single/twin Industrial LED Batten luminaries incl. Supply of 1 no./2nos. 18W LED Tube
99Twin fittings [Philips make Cat No. TMC-501 P1xT-LED 22W P3242 or equivalent make CG / Bajaj / Wipro/ Magik] incl. 2 nos. 18W Master LED Tube(with 2 years warranty
100Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9 mm MS sheet flat suitable for beam having flange upto 150 mm wide[30/D14]
101S & F of MS down rod 14 SWG 20 mm dia MS conduit as per GS & direction of EIC.[NS]
102Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [10/E18]
103Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [ 21 (a) / C-3 ]
104Engraving the deptt. number with 10 mm lettering on the body as per GS.[ 24 (a) / C-3 ]
105Painting upto 10 letters of the engraved number with approved black /red paint as required as per GS[ 26(a)/C-3 ]
106Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length [ 29/C-4 ]
107Supply ofac ceiling fans of 1200mm sweep with burst-proof P2/S3 Capacitorcomplete with all accessories without regulator.( Make - Usha-Striker or equivalent model of Havells/CG/Orient as approved by E.I.C)
108Supply of 450mm sweep wall bracket fan(high speed) with metal body & blades(Orient - Wall-II Tornado or equivalent cat of CG/EPC/Cinni) with necessary wooden board on wall with nuts, bolts, washer etc.(With 2 years warranty order and warrantycertificate should be provide)
109Supply 240 V , 12 inch Electric gong bell (reputed make), material steel , silver color
110Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS[ 2(a)/G-1]
111Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
112Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1]
113Extra for treatment of soil by using salt & charcoal or coke for plate electrode[3(b)/G-2]
114Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
115No.-10 SWG [5(a)(iv)/G-2]
116Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. [5(d)/G-3]
117Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [4(a)/G-2]
118Add GST @18%:- Rs
119Add LWC @ 1% except item no.-31,45,53 ,54& 55 :-