Housing Urban and Rular Development Government Departments Closing in 0 days TDR #35357291

Tender For Supply Of Labour And Electric Work For Balance Work Of Residence Building Typ 2 (04 No) Fire Station Samthar Jhansi

Issued by Government Departments · samthar, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
29 Dec 2022
0 days left
EMD
68000
Bank guarantee accepted
Document Fee
1300
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
samthar → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply Of Labour And Electric Work For Balance Work Of Residence Building Typ 2 ( 04 No ) Fire Station Samthar Jhansi

BOQ

Name of Work:Supply of Labour for Balance work of Residence Building Typ-2 (04 nos) Fire Station Samthar Jhansi
Sl. No. Item Description
1Supply of Labour for TYPE 4 Nos. Residence Building
2First Class bricks works in 1:6 cement and coarse sand of 1.25F.M. mortar in foundation upto plinth supply oflabour and T&P etc. required for proper completion of the work including providing scaffolding rope, chahlies fixing and removal. in foundation.
3laying damp proof course 4.0cm thick with cement concrete 1:2:4 (1Cement: 2 Coarse sand : 4graded gtone aggregate 10mm nominal size) and curing complete.
4Painting on D.P.C. with two coats of air blown bitumen 85/50 @ 1.7 kg/sqm approx including cost of fuel if any.
5First Class bricks works in 1:6 cement and coarse sand of 1.25F.M. mortar in above plinth supply of all labour and T&P etc. required for proper completion of the work. But in super structure in 230mm wall including providing scaffolding rope, chahlies fixing and removal. In Super Structure.
6First Class bricks works in 1:4 cement and course sand of 1.25F.M. mortar in above plinth supply of all labour and T&P etc. required for proper completion of the work. But in super structure in 115mm wall including providing scaffolding rope, chahlies fixing and removal. In Super Structure work.
7Fixing of M.S. angle iron door, windows, ventilator frame made of approved M.S. angle iron wroght to required form including drilling hole, welding and reciting where necessary and also including supply of all materials, such as steel hinges of required size, nut & bolts etc. and also including all taxes, wastage and one coat of red oxide paint complete in all respect as per direction of Engineer in charge for proper completion of work at site of work.
8Fixing ofS.S. Railing Stair case
9fixing of M.S. angle iron Z section window (approved Section) with Specified design of grill out side openable design of window and gril as per approved drawing 10mmsq bar 75mm c/cand 3no. bar group @ 75mm and four group in horizontal including providing stay and one coat of red oxide primer excluding glass pans.
10fixing of M.S. grill of approved quality and drawing made of flat iron including supply of all materials, labour and T&P etc also including one coat of red oxide paint comp. in all respect as per direction of engineer-in-charge (S.I. No. New item 3)
11First Class bricks works in 1:3 cement and course sand of 1.25F.M. mortar in above plinth supply of all labour and T&P etc. required for proper completion of the work. But in super structure in 115mm wall including providing scaffolding rope, chahlies fixing and removal.
12R.C.C. work with cement approved course sand and 2 cm (3/4)” gauge approved stone ballast in the proportions of 1:1½;3 in outer work excluding supply of reinforcement and its bending but including its fixing and bending the same with 24 B.W.G.G.I. Binding wire and including necessary centering and shuttering etc. and also including Supply of all labours and T&P etc. required for proper completion of work binding wire cost being including in the item but for R.C.C. work.Column
13R.C.C. work with cement approved course sand and 2 cm (3/4)” gauge approved stone ballast in the proportions of 1:1½;3 in outer work excluding supply of reinforcement and its bending but including its fixing and bending the same with 24 B.W.G.G.I. Binding wire and including necessary centering and shuttering etc. and also including Supply of all labours and T&P etc. required for proper completion of work binding wire cost being including in the item but for R.C.C. work.Lintel & Sunshed
14R.C.C. work with cement approved course sand and 2 cm (3/4)” gauge approved stone ballast in the proportions of 1:1½;3 in outer work excluding supply of reinforcement and its bending but including its fixing and bending the same with 24 B.W.G.G.I. Binding wire and including necessary centering and shuttering etc. and also including Supply of all labours and T&P etc. required for proper completion of work binding wire cost being including in the item but for R.C.C. work.RCC for Beam
15R.C.C. work with cement approved course sand and 2 cm (3/4)” gauge approved stone ballast in the proportions of 1:1½;3 in outer work excluding supply of reinforcement and its bending but including its fixing and bending the same with 24 B.W.G.G.I. Binding wire and including necessary centering and shuttering etc. and also including Supply of all labours and T&P etc. required for proper completion of work binding wire cost being including in the item but for R.C.C. work.R.C.C. Slab
16Fixing and Removing Of Shuttering in Beam & Collumn
17Mild steel or iron in plain work such as reinforced concrete or reinforced brick work (when not included in an over all rates) wrougth to required shape as necessary including bending for proper completion of the work . R.C.C. work
18filling of sand also including supply of all materials, labour and T&P etc. required for proper completion of the work.
19Cement concrete in 1:4:8 with cement, sand and (22.40-43)mm granite stone ballast (crusher broken) in foundation including supply of all labours and T&P etc. required for proper completion of work.
2015 mm thick plaster with cement mortar over brick work minimum thickness not to be less than 3/8”(10mm) thick including supply of all labour and T&P etc. required for proper completion of the work for proper completion of the work but with cement and approved coarse sand in 1:6 cement & fine sand of 1.25F.M. mortar. inside
2112mm thick plaster with cement mortar over brick work minimum thickness not to be less than 3/8”(10mm) thick including supply of all labour and T&P etc. required for proper completion of the work for proper completion of the work but with cement and approved coarse sand in 1:6 cement & fine sand of 1.25F.M. mortar. in outside
22laying of 8 to 10mm thick ivory or light shade Vitrified tiles of 600mmX600mm size in flooring or skirting laid with 1:3 ( 1cement : 3 Coarse sand) finishing with cement slurry & with pigment grouting & polishing complete i/c supply of all materials, labour T&P required for proper completion of work. in flooring
23laying of 8 to 10mm thick ivory or light shade Vitrified tiles of 600mmX600 mm size in flooring or skirting laid with 1:3 ( 1cement : 3 Coarse sand) finishing with cement slurry & with pigment grouting & polishing complete i/c supply of all materials, labour T&P required for proper completion of work. in Skiting
24laying of 20mm thick Kota stone flooring over 20mm thick base of Cement mortar 1:4 (1cement: 4 coarse sand) laid over jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete.
25fixing 5mm thick China white Glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials labour and tools etc. required for completion of the work . (Size of tiles upto 200X300 mm) in flooring
26fixing 5mm thick China white Glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials labour and tools etc. required for completion of the work . (Size of tiles upto 200X300 mm) in wall
27Making Grooves 10 to 12mm wide X 8mm deep in plaster on the wall or in ceiling etc.
28Making of Drip Couars in same shade or faces i/x supply of all materials, labour etc.
29fixing of 32cm (1.1/4”) thick Commercial Quality (Kanju) Sitapur ply or other approved ply wood flush shutters.
30Supply and fixing of Oxidize door fitting.
31Putty two coated including all Labour T&P etc complete.
32Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
33Weather coat two coat coats------- Finishing walls with Acrylic Smooth exterior paint of required shade 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) sqm 90.00
34Painting or Varnishing on iron works in small areas or new wood work with one coat of ready mixed priming paint & one coat of approved superior quality ready mixed paint or clear synthetic varnish including Supply of all materials labour and T&P etc. required for proper completion of the work. Paint to be used should confirm to the ISI no.103 1950 (In two coat.) wood work.
35Fixing Panes of glass with equal or equivalent ISI marked quality putty Brads and springs and including supply of all materials and labour ete complete. (3.80 to 4.7mm thick)
36fixing of aluminium sheet 24 gauge in door shutter with B & snew----Toilet
3725mm(1½”) thick 1:2:4 plain cement concrete floor with cement, approved coarse sand and 2cm(3/4”) graded approved stone laid in panels finished with 3mm. (1/8”) flooring coat of neat cement or cement and marble dust in 5:1 as specified over removing and over lapping mortar at the joints of panel sand removing any and giving them a uniform finish including Supply of all labour and T&P etc. required for proper completion of the work.
38Providing and injecting chemical for peri constructional Anti-termite and creating and chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling jun ction of wall and floor. Along the external per meter of binding expansion joints currounding of pipes and conduit etc. complete. (plinth area of the building at 6313 (part 2013) IMIDACLOPRID SC 30.5 concenterate or any othe approved material sush as Hepthachlor of Chlordane wall be used. The rate of application of chemical em\"ulsion shall be as follows :- treatment of top surface of plinth filling 5 liters per sqm.
39fixing of Jali door Shutter in teak wood
40fixing of Stainless steel masqutio proof jali window.
41fixing of ward rob shutter
42fixing of Grenite Stone flooring and nosing window sil and courter
43filling of Sinder in Sukan portion of toilet
44fixing of M.S. Sheet door
45laying “Brick bat Coba” 100 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with aerelic cement concrete water proofing compound filled gaps of coba & including supply of all materials labour T&P etc. required for proper completion of work and as per direction of E.I.C.
46fixing 110mmø PVC pipe complete with rose heads bends M.S. Clamps 2.5cmX3mm fixed to walls by 15cm long 6mmø nail and including repair of plaster pointing etc if damaged during fixing of the pipes including cost of all material labour, tools and plant etc. required for proper completion of work.
47Making Khurra
48Moulding of Graynite stone
49Supply of Labour for SEPTIC TANK FOR 25 USER
50Excativion in foundation in mixed soil
51filling of Sand
52Lean Concrete in 1:4:8 in C:C/S:S/ballest (40mm)
53R.C.C. work with cement approved course sand and 2 cm (3/4)” gauge approved stone ballast.
54Brick work in 1:4 C:C/Sand mortar in sides
5520mm Plaster with 1:2 C:C/S + neat cement
56R.C.C. in 1:1½:3 C:C/S:S/G Top cover
57Cutting & binding of for steel
5840mm P.C.C. flooring in 1:2:4 C:C/S:S/G
5912mm plaster outer side
60Supply of Labour for SOAK PIT (Inner Dia 2.50mts)
61Excavation in foundation insoil mixed with moram/kankar in bundelkhand area requiring use of specials tools and plants such as pick axes and sabbal etc. (Rate ins including Royality) (¶d2/h)
62First Class bricks works in 1:4 cement and coarse sand of 1.25F.M. mortar in foundation upto plinth supply of all labour and T&P etc. required for proper completion of the work including providing scaffolding rope, chahlies fixing and removal. in foundation. (Honey Comb Brick Work with 1:4 C:Sand) (¶d2/h)
63Filling of Brick Bats (¶/4) = 0.79
64R.C.C. work with cement approved course sand and 2 cm (3/4)” gauge approved stone ballast in the proportions of 1:1½;3 in lintels of doors and windows excluding supply of reinforcement and its bending but including its fixing and bending the same with 24 B.W.G.G.I. Binding wire and including necessary centering and shuttering etc. and also including Supply of all labours and T&P etc. required for proper completion of work binding wire cost being including in the item but for Slab etc.
65Mild steel or iron in plain work such as reinforced concrete or reinforced. for Slab.
66Brick on edge
67Supply and fixing 110mmø PVC pipe complete with rose heads bends M.S. Clamps 2.5cmX3mm fixed to walls by 15cm long 6mmø nail and including repair of plaster pointing etc if damaged during fixing of the pipes including cost of all material labour, tools and plant etc. required for proper completion of work.
682cm. (.3/4”) thick cement plaster in Dedo or skirting in 1:2 consisting of one part of cement and 2 part in panels, finished with 3mm. (1/8”) floating coat of neat cement or cement and marble dust in redio of 5:1 including Supply of all labour and T&P etc. required for proper completion of the work. (For dedo skirting)
6915 mm thick plaster with cement mortar over brick work minimum thickness not to be less than 3/8”(10mm) thick including supply of all labour and T&P etc. required for proper completion of the work for proper completion of the work but with cement and approved coarse sand in 1:6 cement & fine sand of 1.25F.M. mortar. inside
70Casting of Man Hole Chamber 600X600X750
71Fixing Of P.V.C Pipe 150 mm Dia
72Supply of Labour for Sanitary & Water Supply
73fixing of European type white glazed earthen ware W.C. pan Indian approved 1st Quality ISI marked backlight seat cover and lit of C.P. brass hinges and rubber buffers.
74fixing Ist Quality W.C. Orrisa pan white glazed earthen ware ISI marked WC pan size 580mm(Hindustan, Cera make) including supply of all materials, labour and T&P etc. required for proper completion of work.
75fixing of Wash hand Basin size 550x400mm ISI marked basin (Hindustan, Cera, Parrywere make)
76Laying of Stanless Steel Sink of size 600X450X200mm with drainges board
77fixing of C.P. Brass towel rail 600mm size together with pair of C.P. brass brackets to fit towel rail.
78fixing of 600X400mm beveled edge mirror of superior glass mounted on 6mm thick A.C. Sheet or plywood sheet and fixed to plastic sleeves with C.P. Brass screws and washers.
79fixing of C.P. Soap dise.
80fixing of PVC Tank 1000 lits.
81fixing of Angle cock
82fixing of 15mmø C.P. Short body Bib cock.
83fixing of 100X75mm PVC Nahani Trap.
84fixing of C.P.waste 32mmø
85fixing of C.P.waste 40mmø
86fixing of C.P. Jali 100mmø
87fixing of C.I. Door Tee 100mmø
88fixing of C.I. Door Tee 75mmø
89fixing of C.I. Door bend 100mmø
90fixing of C.I. Door bend 75mmø
91Supply and fixing of M.S. Clamp.100mmø
92Supply and fixing of M.S. Clamp.75mmø
93Making lead Joint 100mmø
94Making lead Joint 75mmø
95fixing of C.I.Pipe ISI mark C.I.pipe 100mmø
96fixing of C.I.Pipe ISI mark C.I.pipe 75mmø
97fixing of G.I.pipe 15mmø
98fixing of G.I.pipe 20mmø
99fixing of G.I.pipe 25mmø
100fixing of 15mm PVC Connection 45mm long.
101fixing of Gate Valve.25mmø
102fixing of Gate Valve. 15mmø
103fixing of C.I. Collar 100mmø
104fixing of C.I. Collar 75mmø
105Cutting of Hole in R.C.C.
106fixing of C.I. Plan bend 100mmø
107fixing of C.I. Plan bend 75mmø
108Supply of Labour for Construction of APRON DRAIN 250mm wide
109Excavation in foundation insoil mixed with moram/kankar in bundelkhand area requiring use of specials tools and plants such as pick axes and sabbal etc. (Rate ins including Royality)
110Supply and filling of Sand.
111Cement concrete in 1:4:8 with cement, sand and (22.40-43)mm granite stone ballast (crusher broken) in foundation including supply of all materials, labours and T&P etc. required for proper completion of work.
112First Class bricks works in 1:4 cement and course sand of 1.25F.M. mortar in above plinth supply of all materials, labour and T&P etc. required for proper completion of the work. But in super structure in 230mm wall including providing scaffolding rope, chahlies fixing and removal. In Super Structure.
11325mm cement concrete flooring 1:2:4 ( 1 cement: 2 coarse sand:4 graded stone aggregate of size 12.5mm and below) by laid over concrete finished with floating coat of neat cement (base concrete to be paid separately) including fixing of glass strips. (Excluding cost of glass strips.)
1142cm. (.3/4”) thick cement plaster in on Drain Side & Top in 1:2 consisting of one part of cement and 2 part in panels, finished with 3mm. (1/8”) floating coat of neat cement or cement and marble dust in redio of 5:1 including Supply of all materials labour and T&P etc. required for proper completion of the work.
115Electric Work (Labour With Material)
116Wring point for light with 1.5 Sq. mm FRLSHinsulated multistrend single core copper conductor cable in PVC conduit with 1.5 Sq. mm FR PVC insuleted multistrend copper conductor cable as earthwire drawn inside Modular type switch & celling rose angle/ batten holder on 3mm thick phenolic paminated backlite sheet etc.complete in all respect.
117Wring point for fan/fresh air fan (light duty exhaust fan) with 1.5 Sq. mmFRLSH insulated multistrend single core copper conductor cable in PVC conduit with 1.5 Sqmm FR PVC insuleted multistrend copper conductor cable as earthwire drawn inside Modular type switch & celling rose angle/batten holder on 3mm thick phenotic paminated backlite sheet etc. complete in all respect.
118Wring point for plugwith 1.5 Sq. mm FRPVC insulated multistrend single core copper conductor cable in PVC conduit with 1.5 Sq. mm FR PVC insuleted multistrend copper conductor cable as earthwire drawn inside Modular type switch & socket etc. complete in all respect.
119Wring point for call Bell with 1.5 Sq. mm FRLSH insulated multistrend single core copper conductor cable in PVC conduit with 1.5 Sq. mm FR PVC insuleted multistrend copper conductor cable as earthwire drawn inside plano type switch & socket etc. complete in all respect.
120Wring point for Exhaust Fan with 1.5 Sq. mm FRLSHinsulated multistrend copper conductor cable in PVC conduit with 1.5 Sq. mm FR PVC insuleted multistrend copper conductor cable as earthwire drawn inside 15A Modular plano type switch & Ceiling rose on 3mm thick backlite sheet complete in all respect.
121S/F of hexagonal fan box with hexagonal side of approx 80mm in legnth fabricated from 16 SWG MS sheet incorporating 10 mm dia, MS round bar as per approved complete in all respect.
122Supply & wiring of submains with two number 10 sq.mm PVC insulated single core copper conductor in 25mm dia heavy duty PVC conduit with 1 no. 6sq.mm FR PVC insulated multistrend single core copper conductor cable as earth continulty wire drawn inside the conduit complete in all respect.
123Supply & wiring of submains with two number 6 sq.mm PVC insulated single core copper conductor in 25mm dia heavy duty PVC conduit with 1 no. 4 sq.mm FR PVC insulated multistrend single core copper conductor cable as earth continulty wire drawn inside the conduit complete in all respect.
124Supply & wiring of submains with Four number 10 sq.mm PVC insulated single core copper conductor in 25mm dia heavy duty PVC conduit with 2 no. 6 sq.mm FR PVC insulated multistrend single core copper conductor cable as earth continulty wire drawn inside the conduit complete in all respect.
125Supply & wiring of submains with two number 2.5 sq.mm PVC insulated single core copper conductor in 25mm dia heavy duty PVC conduit with 1 no. 1.5 sq.mm FR PVC insulated multistrend single core copper conductor cable as earth continulty wire drawn inside the conduit complete in all respect.
126Supply and fixing of batten holder complete in all respect
127Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects.
128S/F of LED Tube light with Batten suitable for up to 1X22 Watt LED tube light complete including tube etc.On surface complete in all respect CAT-AA
129S/Laying of \"Al\" conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size of as directed by the Engineer - Incharge, complete in all respect. The armouring of the cable ahsll be properly connected with the earth conductor by clamps etc. 50 sq.mm 3.5 core.
130Supply & Erection of factory fabricated and wired metal cald dust and vermin proof floor mounting M.S.Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB (Fore Pole 36KA with thermal maganatic release) Switches complete and instrument chamber etc. complete in all respects. The instrucment chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameter (KVA, P.F.KW etc.) in each phase with touch type selector switches for different reading, instrument fuses, current transformer etc.. The MCCB\"s shall be complete with sultable cable end boxes, compression glands and indicating lampon incoming etc.The Job includes the grounting of the board as per direction of Engineer-in-charge. All out goings of 100Amp. and above with be provided shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of Cat A & B Only. Incoming :- 100Amp. MCCB-01 No. outgoing 63amp MCCB-2 Nos , 32amp MCCB 1 Nos.
131Supply & burying of Earthing Electrode T-19 (Hot Dip Galvanized), Length 300mm, Outer pipe 50mm, inner pipe 25, Terminal dia 12mm, Outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip galvanization up to 100 micron filled with crystllingnce conductive mixture (CCM) having anti corrosive & conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm squre C.I. frame with hinged cove & masonty housing. (From electrode terminal to switch board, cost of 25x3 G.I. strip will be extra) Make: As approved in U.P.P.W.D., & C.P.R.I. Certified.
132S&L of 25mm x 3mm G.I. Strip from earth electrode directly in the ground as requird complete in all respect.
133S/F of electronic fan regulator 120-280 V ISI marked ,on the existing switch board including making connections, required material, labour T/P etc. for proper completion of work to the satisfaction of Engineer in Charge of work.
134S/F of 6Amp. To 32 amp. SPMCB (10 KA)Cat B
135S/F of 63 amp DP MCB CAT- B
136S/F of 40ampSPMCB CAT- B
137S/F of 63 amp SPMCB CAT- B
138S/F of 63 amp FP MCB CAT- B
139S&F surface/flush mounting 8 ways SPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge. Cat-B
140S & F surface/Flush mounting 4ways V TPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge. CAT -B
141S&F surface/flush mounting 4 ways SPN distribution board without MCB complete in all respect, as directed at site byEngineer in charge. Cat -A
142S&F of Power plug with 20A/250volt flush type switch and 5 pin 20A/250V flush type universal socket in suitable MS box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer.
143Supply of Erection of Ceiling fan 1200 mm ISI mark. Sweep, 230/250 Volts, 50 Hz standared down rod, bleads including connection etc. complete as required.
144S/F of Light duty Exhaust Fan 300mm
145Supply and fixing of M.S. Drum Dully painted with luvers making hole in wall for exhaust fan complete.
146S/F of LED Bulb 9 Watt
147Supply and fixing of Call bell
148S/F fan sheet cover of backelite sheet
149Supply & wiring of submains with two number 1.5 sqmm PVC insulated 1100 V grade Multistrand single core copper conductor in 20mm dia heavy duty PVC conduit with 1 no. 1.5sqmm FR PVC insulated multistrend single core drawn inside the conduit complete in all respect.
150S/F OF exhaust fan lovers 12\"

AI Tender Summary

OUR REF NO 35357291
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 29-12-2022
Authority
Authority Name Uttar Pradesh State Construction and Infrastructure Development Corporation Limited
Work Description Supply Of Labour And Electric Work For Balance Work Of Residence Building Typ 2 ( 04 No ) Fire Station Samthar Jhansi
Basic Detail
Tender No 32/SE/Jhansi/ET/2022-23
Bidding Type Tender
Location
City samthar
State Uttar Pradesh
Key Dates
Publish Date 19 Dec 2022
Submission Date 29 Dec 2022
Open Date 29 Dec 2022
Finance
Tender Value Ref. Documents
Tender Fee 1300
EMD 68000
Exemption Not Available
Document List
0a6173ac-23c4-4d66-9ab2-d8aa10115b06.html
BOQ_1250761.xls
laboursamtharnit.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 19, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 29, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 29, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

0a6173ac-23c4-4d66-9ab2-d8aa10115b06.html

xls

BOQ_1250761.xls

pdf

laboursamtharnit.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders