Military Engineer Services-MES has published Tender For Repair / Maintenance / Conversion Of Overhead Lt Lines Into Ug Cable And Allied Works At Dronachal Bhopal. Submission Date for this Tender is 09-01-2023. Overhead Line Tenders in bhopal Madhya Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Excavation in trenches in soft/hard of any type soil not exceeding 1.5m deep and not exceeding 1.5 m wide and getting out complete all as specified and directed. |
2 | Returning, filling in including spreading, levelling, watering and well ramming excavated soilin layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays , struts have been erected and tested , complete all as specified and directed. |
3 | Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
4 | Supply and spread dry river sand for UG cable cushioning including punning on top and bottom of the cable completeall as specified and directed. |
5 | Supply and lay standard size common burnt clay building bricks sub class "B" for cable protection, laid dry complete all as specified and directed. |
6 | M&L for earthing complete with galvanised steel earth plate electrodesize 600x600x6.3mm thick burried directly in groundvertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron strip 32X6 mm earth lead by means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion.NOTES 1. The unit rate includes for protection pipe and GI strip dia from top of earth plate upto 5.00 meter above groung level. |
7 | M&L cutting PCC/floor/road and taking out cable and making good, including material as per existing after laying of pipe for cable protection complete all as specified and directed size of trench not more than 0.30 x 0.30 cm. |
8 | S&F in replacement of GI Pipe medium grade on wall/floorfor cable protection with fixing arrangement size 80mm dia complete all as specified and directed. |
9 | Supply and LayingXLPE heavyduty armoured electric under ground cable aluminum conductor 1100 volts grade in trenches/on pole through sleeves etc.complete all as specified and directed. |
10 | Cross sectional area 185 Sqm 31/2 Core. |
11 | Cross sectional area 120 Sqm 3.5 Core. |
12 | Cross sectional area 25 Sqm 4 Core. |
13 | Cross sectional area 35 Sqm 3.5 Core. |
14 | Cross sectional area 10 Sqm 4 Core. |
15 | Supply installation, testing and commissioning LT Feeder piller board out door type cubicle panel boardsuitable for 3 phase,4 wire 415 volt 50 hz factory febricated approved CPRI powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gaket for natural flow of air with canopy, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with alluminium bus bar three phase and neutral of capacity of 800 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mmmultistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , Panel shall be grouted on PCC foundation complete all as specified and directed with following accessories:- |
16 | INCOMING:- (a) MCCB 250 Amps, 415 volts4 pole 25 KA -01 No OUT GOING:- (a) MCCB 63 Amps microprocessor released 4 pole 415 Volts, 16 KA-10 Nos (b) Digital type Volt meter 0-500 Voltssquare typewith selector switch- 01 No. (c) Digital type Ammeter 0-400 Amps square typewith selector switch- 01 No. (d)Wiring complete with copper wire of suitable size (e) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set. (f) Cable glands brass of suitable size for cable. Note:- Approval of Engr-In-Charge must be obtainedfor Panel design/drawing and CPRI approval of manufacturerbefore placing order. |
17 | Dismantaling of cross arms of MS channel or angle sections incl nut bolts etc. |
18 | Dismantalingpin / shackle insulators any type any size. |
19 | Dismantaling of ACSR conductor |
20 | Dismantling earth wire or copper conductor, service feeder or distributor span |
21 | Dismantling stay assembly complete. (demolition of concrete, etc. and excavation measured separately) |