| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with piano type switch, phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc. asrequired.Group C |
| 2 | Rewiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable and 1.5 sq.mm FRLS PVC insulated copperconductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.Group-C |
| 3 | supply and fixing of following sizes medium class pvc conduit along with accessories in surface / recess including cutting the walland making good the same in case of recessed conduit as required a)25 mm |
| 4 | Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3x2.5 sq.mm |
| 5 | 3x4 sq.mm |
| 6 | 3x6 sq.mm |
| 7 | Supplying and fixing following piano type switch/ socket on theexisting switch box/ cover including connections etc. as required. 5/6 amps switch |
| 8 | 15/16 A switch |
| 9 | 3 pin 5/6 A socket outlet |
| 10 | 6 pin 15/16 A socket outlet |
| 11 | supply of XLPE Insulated PVC Sheathed Al. Conductor Armoured Cable for working voltage upto 1.1kV confirming to IS-7098(Part-I) of following sizes: (a) 2 x 10 sq.mm |
| 12 | LayingandfixingofonenumberPVCinsulatedandPVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 13 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm |
| 14 | supply and fixing of Metal box 180mm x 100 mmx 60 mmdeep (nominal size) on surface / recess with suitable size of phenolic laminated sheet cover infrontincluding providing and fixing 6 pin5/6 &15/16A socket outlet and 15/16A piano type switch ,connection painting etc as required. |
| 15 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker single polesuitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 16 | Supplying and fixingfollowing rating 63 Amp double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 17 | Supplying and fixing Single pole blanking plate in the existing MCB DB complete etc. as required |
| 18 | Supply and fixing of 4.5 Kg DCP with COCO2 fire extinguisher (wall mounting type)gas cartridge fire extinguisher (conforming to IS: 2171 with cylinder fully charged) |
| 19 | supply and fixing of 400mm single phase swing wall fan as reqd. |
| 20 | Supplying and fixing following rating, four pole, (three phaseand neutral), 415 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DBcomplete with connections, testing and commissioning etc. asrequired.63A |
| 21 | Supplying, lowering, testing and commissioning of following capacity vertical type, multistage, totally enclosed, water filled, deep well submersible pumping set complete i/c connections etc as reqd. Elec92.a Single phase 1.5 HP, having discharge of 60 LPM (approx.) at 50 M head. |
| 22 | Supply, Installation, testing and commissioning of cubical type control panel board for single phase submersible pumping set of following rating complete with contactor, relay , MCB ,condenser ,voltmeter, ammeter and indication lamp etc including connections etc as reqd. 1.5 H.P rating Submersible P/Set. |
| 23 | P/FHot press sheet mouldedcompound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof polebox of innerdimension 2000x160x98mm (NS) complete with suitable arrangment for fixing of 1 noof 6 to 32 amp single pole MCB(MCB/Isolator excluded) withneutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plateofsuitable size with danger monogram property printed on the coveretc asreqd.( Without MCB) |
| 24 | Supplying and fixing metal box of following sizes (nominal size)on surface or in recess with suitable size of phenolic laminatedsheet cover in front including painting etc. as required.180 mm X 100 mm X 60 mm deep |
| 25 | SITC of surface mounting LED luminaire suitable for 1X20 watt LED rating complete with extruded aluminium batten prewired with high efficient LEDs with the following: a) Total System Wattage 20 ±5% Wattb) Luminaries effucacy = 100 lumens/watt c) Power factor = 0.95 |
| 26 | S/I/T/C of Surface mounting CRCA housing 36WLED luminaire with acrylic cover diffuser with following specificationsincluding fixing on existing wall/surface with connections as reqd. (a) Total System Wattage = 36 watt +/- 5% (b) Luminius Effcacy >=95 lumens / watt (c) Power factor >= 0.95 |
| 27 | SITC of 60 W LED street Light luminiare fitted with lense, made of pressure die cast aluminium housing & toughned glass cover complete with the following specification as reqd... (a) Total system wattage =60watt +/- 5%b)Luminaire Efficacy>=100 Lm/wc) Power Factor>=0.95d) Protection IP-66 |
| 28 | Supply and fixing of 32 mm dia G. I pipe ( Medium class) 1 mtr long bracket 1/c wiring with 2.5 sq mm copper conductor wire as required. |
| 29 | supply and layingof 6 sq mm aluminium conductor PVC insulated flat twin core W/P wire complete as required |
| 30 | Supply, Installation, Testing and Commissioning of 1200mm sweep, BEE 5 star rated, ceiling fan with Brush LessDirect Current (BLDC) Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, Power Factor not less than0.9, Service Value (CMM/W) minimum 6.85, Air deliveryminimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulatorunit for speed control and all remaining accessoriesincluding safety pin, nut bolts, washers, temperaturerise=75 degree C (max.), insulation resistance more than2 mega ohm, suitable for 230 V, 50 Hz, single phase ACSupply, earthing etc. complete as required. |
| 31 | Installation, testing and commissioning of ceiling fan, includingwiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cableetc. as required |
| 32 | Rewinding of AC ceiling fan / Exaust fan of all sizes and make i/c oiling, greasing as required. |
| 33 | Replacment of Ball Bearing as required. |
| 34 | SITC of 150 Ltr water cooler with following specifications are : (a) Cooling Capacity Litres / Hour 150 Liters/hour (b) Eco-Friendly Refrigerant (c) Water Tank sheet material - Stainless Steel 340 (d) Water Tank cover and lid bottom Sheet material - High Impact Polystrene(HIP) (e) Reciprocating Tropicallized energy efficient Compressor (f) Number of faucets - 2 Nos. (g) Anti - corrosive Pre-coated Body (H) Use on 1 phase 220-240 Volt (I) Power code length 4 Meter with 15 Amp Plug etc as reqd. |
| 35 | Supply & Installation of 253 Litre 3 Star with inverter Double door refrigerator suitable with automatic Defrosting system with door lock arrangement and stabilizer free for single phase 220V ± 5% supply etc as reqd. |
| 36 | Supplying and fixing 20 amps. 240 volts SPN industrial type socket outlet with 2 pole and earth metal enclosed plug top along with 20 amps \"C\" curve SP MCB in sheet steel enclosure on surface or in recess with chainedmetal cover for the socket outlet and complete with connection, testing and commissioning etc. as required. |
| 37 | Supply of 1.5 TR Split Type Air Conditioner (5 star rating) along with Installed Copper piping & 3 Core suitable copper wire, PVC hard drain pipe with remote suitable for 230V AC. supply complete as required.(upto 6 Mtr.) |
| 38 | Standard Installation charges for Split AC including labour and all items required for installation complete as reqd. |
| 39 | Supply & fixing of extra angle iron stand suitable for 1.5 TR Split Type Acs out door unit complete as reqd. |
| 40 | Extra for copper piping with proper insulation with PVC hard drain pipe and 3 core copper wire suitable for 1.5 TR Split type AIR Conditioner complete as reqd. |
| 41 | P&F of 4KVA Voltage Stabilizer with TDR and Triple step, High & low voltage cut off device complete as reqd. |