Tender For Misc Repair/ Replacement Of Unserviceable Items Pertaining To Desert Cooler, Water Cooler, Refriferators, Geysers, Ro System, Air Curtain And Other Connected Misc E/M Works Under Ge (E/M) Base Hospital Delhi Cantt-10, delhi-Delhi

Military Engineer Services-MES has published Tender For Misc Repair/ Replacement Of Unserviceable Items Pertaining To Desert Cooler, Water Cooler, Refriferators, Geysers, Ro System, Air Curtain And Other Connected Misc E/M Works Under Ge (E/M) Base Hospital Delhi Cantt-10. Submission Date for this Tender is 21-01-2023. Air Cooler Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

35338639
Corrigendum : Tender For Misc Repair/ Replacement Of Unserviceable Items Pertaining To Desert Cooler, Water Cooler, Refriferators, Geysers, Ro System, Air Curtain And Other Connected Misc E/M Works Under Ge (E/M) Base Hospital Delhi Cantt-10
Open Tender
Indian
Delhi
delhi
21-01-2023

Tender Details

Misc Repair / Replacement Of Unserviceable Items Pertaining To Desert Cooler, Water Cooler, Refriferators, Geysers, Ro System, Air Curtain And Other Connected Misc E / M Works Under Ge ( E / M ) Base Hospital Delhi Cantt-10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Jan-2023 TENDER DOCUMENTS Technical Bid 12-01-2023
2 09-Jan-2023 EXTENDEDDATE Date 12-01-2023
3 12-Jan-2023 TENDERDOCUMENTS Technical Bid 14-01-2023
4 12-Jan-2023 EXTENDEDATE Date 14-01-2023
5 14-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 85280.0 /-
Tender Value
INR 42.64 Lakhs /-

BOQ Items

Name of Work:MISC REPAIR/ REPLACEMENT OF UNSERVICEABLE ITEMS PERTAINING TO DESERT COOLER, WATER COOLER, REFRIFERATORS, GEYSERS, RO SYSTEM, AIR CURTAIN AND OTHER CONNECTED MISC E/M WORKS UNDER GE (E/M) BASE HOSPITAL DELHI CANTT-10
Sl. No. Item Description
1Collecting of unserviceablevoltage stabilizerof capacity 1 to 5 KVA from the MES store yard of GE E/M BHDC or dismantlingthe same from site and transporting to contractors workshopfor locating the fault includingcheckingthe serviceability of electrical/electronic circuits relays andreplacement of defective spare parts , reassembling after making connections, testing by applying low and high voltage input to get the 230 volts correct output and transporting back the same to MES store yard complete all as specified and directed by Engr-in-Charge Note:-Replacement of defectivespares as "Supply only" of voltage stabilizerwill be measured & paidseparately under relevant items and Labour charges for taking out old spares & fixing of new sparesshall deemed to be included in unit rate quoted.
2Supply onlyfollowing new spare partsof Voltage stabilizerofcapacity 1 to 5 KVA:-
3Voltmeter (Analog) 0 to 300 volts any type shape single phase 50 Hz AC supply (Make:- AE/ MECO/ Rishabh)
4Digitaltype Voltmeter0 to 300 volts any type shape single phase 50 Hz AC supply (Make:- AE/ MECO/ Rishabh)
5Printer circuit control card suitable for 2 to 5 KVA.
6Input/ output switch (Make:-AE/Rishabh/Meco)
7Push on switch (Make:-AE/Rishabh/Meco)
8Indicator with neon bulbs (Make:- AE/ L&T/ C&S)
9Trigger Transformer for 1 to 5 KVA.
10Relay for 1 to 5 KVA voltage stabilizer (Make:-Renutrol/ Technomac)
11Time relay and High/low voltage cut off circuit with relay suitable for 2 KVA to 5 KVA (Make- Renutorl/Technomac) Note for item No 2.01 to 2.09:- Materials of item No 2.01 to 2.09 to be incorporated in item No 1.00 here-in-before.
12Taking out the burnt winding of transformer of voltage stabilizer and preparing core after cleaning by suitable cleaning agent and rewinding the transformer of voltage stabilizer with super enameld copper wire of existing gauge including varnishing, heating and refiting of capacity 2KVA voltage stabilizer, complete all as specified & directed by Engr-in-Charge.
13All as per srl item No. 3 here-in-before but 3 KVA.
14All as per srl item No. 3 here-in-before but 4 KVA.
15All as per srl item No. 3 here-in-before but 5 KVA.
16Disconnecting from mains and taking downfor servicingofWater Cooler ofCapacity 40/80, 60/120, 150/180Ltrs including cleaning of cooling coil, air filters, condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs,fan andblower, etc., andkeepingthe Water coolerunit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed by Engineer-in-Charge. Note:-Replacement of defectivespares for making the water cooler units in satisfactory working condition will be measured & paidseparately under relevant items as "Supply only" and Transportation & labour charges for taking down old spares and fixing of new sparesshall deemed to be included in unit rate quoted above.
17Supply onlyfollowing new spare parts of Water cooler unit ofcapacity 40/80 to 60/120, 150/180 Ltrs:-
18Starting relaysuitable for 40/80, 60/120, 150/180 Ltr. (Make: Sri Ram/Renutrol/Micro Tech.)
19Starting Capacitor 25 MFD. (Make :- Usha/Epcos/Keltron)
20Running Capacitor 10 MFD. (Make:-Usha/Epcos/Keltron)
21PVC flexible drainHose pipe 40 mm. (Make :- PRAYAG/SUPREME/PRINCE)
22Condenser fan blade aluminium body for Motor 1/32HP, 1/35HP .(Make: Tipcon/ Usha/Epcos/Keltron)
23Over load protector device for 60/120 ltrs capacity water cooler. (Make: Sri Ram/Renutrol/Micro Tech.)
24Over load protector device for 40/80 ltrs capacity water cooler. (Make: Sri Ram/Renutrol/Micro Tech.)
25Over load protector device for 150/180 ltrs capacity water cooler. (Make: Sri Ram/Renutrol/Micro Tech.)
26Tharmostat switch. (Make: Indfoss/Renutrol/Godrej.)
27Self closing chromium plated push taps for water cooler Capacity 40/80, 60/120, 150/180 Ltr.(Make: Usha/Prayag/ Cera/ Essco) Note for item No 8.01 to 8.10:- Materials of item No 8.01 to 8.10 to be incorporated in item No 7.00 here-in-before.
28Disconnecting the electric and Water connections and taking out the existing unserviceable compressor of any make from water cooler storage type capacity60/ 120 Ltrs from any location andsupply installation & testing of new sealed unit compressorof similar capacity in same locationalongwith test Certificate from manufacturer and cleaning of condenser by machine doing vaccum on the fully system and supply and charging of oil gas and other necessary lubricants including reconnecting the electric and water connections, transportaion& testing complete all as directed by Engr-in-Charge. (Make- Tecumseh/ Emerson/ LG.)
29All as per item No. 9 above butWater coolerofcapacity 40/80 Ltrs.
30All as per item No. 9 above butWater coolerofcapacity 150/180 Ltrs.
31Disconnecting the electric mains and taking out unserviceable condenser fan motor1/16 HP from water cooler capacity 60/120 Ltr, supply and fixing of new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as directed by Engr-in-Charge. (Make : AUE, Crompton Greaves/ Cool Master)
32All as per item No. 12 above but 1/32 HP Water coolerofCapacity 40/80 Ltrs.
33Disconnecting the mains and taking out the unserviceable condenser coil, S&F new condenser coil as per existing size & patterns for Water/ Coolers of capacity 150/180 Ltrs complete all as specified & as directed.
34Disconnecting the mains and taking out the unserviceable condenser coil and S&F new condenser coil as per existing size & patterns for Water/Coolers of capacity 60/120 Ltrs complete all as specified & as directed.
35Disconnecting the mains and taking out the unserviceable condenser coil, S&F new condenser coil as per existing size & patterns for Water/Coolers of capacity 40/80Ltrs complete all as specified & as directed.
36Dismantling the evaporator/cooling coil of water cooler capacity 150/180, 60/120 & 40/80 Ltrs, checking the leakages of gas and rectify the leakages by brazing or as other manner and refixing in same position complete all as specified & as directed by Engr-in-Charge.
37Cleaning & removing the existing paint ofWater Coolers capacity150/180, 60/120 & 40/80 Ltrs by rubbing & preparing the surface smooth & applying one coat of zinc chrome primer and two coats of synthetic enamel paint (1st grade quality) by spray gun machine of colour as approved by Engr-in-Charge.
38Taking up or down steel tubing and connections and removing off site15mm bore of pipecomplete all as specified and as directed.
39Supply and fixinggalvanised steel tubing 15 mm bore, medium grade with all fittings (such as bends, elbows, tees, short plugs and union etc.)fixed on wall or floor complete all as specified and as directed.
40Supplying and fixing in repairs stop valve 15mm bore dia, fancy type chromium plated with long shank and cup (concealed type), screwed both ends for iron pipe or for unionscomplete all as specified and as directed.
41Taking down unserviceable PVC connection pipe and Supply and Fixing of PVC connections pipe of 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed.
42Material and labour for detecting of leakages of gases in Water cooler, Refrigerator, deep freezer of any capacity at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition.
43Disconnecting from mains and taking downfor servicingof Refrigerator/ Deep freezerofCapacity 165/180/195/310/330/450 and 500 Ltrsincluding detecting the leakage of gas and refilling of refrigerant,cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., andkeepingthe Refrigerator unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed by Engr-in-Charge. Note:-Replacement of defectivespares for making the Refrigerator/ Deep Freezer units in satisfactory working condition will be measured & paidseparately under relevant items as "Supply only" and Labour charges for taking out old spares and fixingof new sparesshall deemed to be included in unit rate quoted.
44Supply onlyfollowing new spare parts of Refrigerator/Deep freezer 165/180/195/310/330/450 and 500 Ltrs capacity:-
45Thermostat switchwith Knob. (Make :- Indfoss/ Renutrol).
46Starting relay 1/6 H.P.Open type with O.L.P. (Make :-Renutrol/ Sri Ram/ Microtech).
47Starting relay 1/8 H.P. open type with O.L.P.(Make :-Renutrol/ Sri Ram/ Microtech).
48Copper filter single capilary pencil type.
49Vegetable tray PVC for 165 to 330 Ltr capacity (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
50Defrost tray for refrigerator capacity 165 to 330 Ltr (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
51PVC ice tray flexible. (Make:- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
52Refrigerator bottle shelf for 165 to 330 ltr capacity (Make:- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
53Waste water tray suitable for different type of Refrigerator. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
54Freezer door for 165/180/195 Ltr capacity. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
55Freezer door for 280/300/330 Ltr capacity. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
56Door Lock for refrigerator 165 to 330 ltrs. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
57Door switch for refrigerator 165 to 330 ltrs. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
58Interior light fittings with bulb. (Make:- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
59Door handle suitable for 165 to 330 Ltrs. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
60Refrigerator Glass shelves of capacity 165/180/195 Ltrs. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
61Refrigerator Glass shelves of capacity 280/300/310/330 Ltrs. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.) Note for item No 25.01 to 25.17:- Materials of item No 25.01 to 25.17 to be incorporated in item No 24 here-in-before.
62Disconnecting from mains and taking down the unserviceable compressorunit of Refrigerator of any make and type and providing New Compressor suitable for 165 to 195 ltr capacityalongwith test certificate from manufacturer including supply of therefrigerant gas R-134A and filling and replacement of filter and put in working condition all as directed by Engr-in-Charge. (Make :Tecumseh/LG/Godrej.) Note:-The rates quoted by the contractor shall deemed to include the transportation cost from site of installation to contractor"s repair workshop and back.
63All as per item No. 26above but following capacity of Refrigerator:-
64Refrigerator 280/300/310/330 Ltrs capacity.
65Deep Frteezer 400 Ltrs capacity.
66Deep Freezer 500 Ltrs capacity.
67Taking out unserviceable evaporator/ freezer from the refrigerator & supply & fixing evaporator/ freezer made out of aluminium press type of capacity 280/300/310/330/400 and 500 ltrwith freezer frame and door including connection, complete all as specified & as directed. (Make - Whirlpool/Godrej/Kelvinator/LG/Sumsung.)
68All as per item No. 28 but capacity of the refrigerator 165 to 195Ltrs capacity.
69Taking down desert cooler of any type (Steel body/Plastic body) and any capacity from any height/ floor andrefixing the same in same location after repair work/ overhauling all as required at site. Note:- Repair work not included in the quoted rate.
70Preparation for old painted surface of desert cooler of any capacity and any make on inner surface & outer surface.Repainting the complete desert coolers ie side panel, bracket, body & desert cooler stand with two coats of synthetic enameled paint (1st grade quality) including two coats of black water proof paint on reserve water tank & marking with “ GE E/M BHDC (MES)” letter size of 50mm height in stencil in black/white including servicingandgreasing of fan motor/pump and replacement of PVC pipe worn out nut, bolts and washers complete all as per site requirement.
71Supply and fixing in repairs wood wool padapproximate weight 800 - 900gms of size 24” sweep desert cooler as per existingcomplete all as specified and directed.
72All as per item No 32 above but approximate weight 700 - 800gms and20” sweep.
73Supply and fixing in repairs submersible pump motor 230 Volts , single phase, AC suitable for Plastic body/Steel body Desert cooler complete all as specified & as directed.
74Supply and fixing in repairs of exhaust fan motor copper woundedhaving 1400 RPM, 150 watts with 500mm sweep suitable for operation on 230 volts, 50Hz, AC supply including fan brackets/ clamps of suitable size and all fixing accessories complete all as specified & as directed.
75Supply and fixing in repairs of desert cooler copper wounded kitfan motor of capacity 90 Watt complete all as specified & as directed.
76Supply and fixing in repairs front grill for desert cooler of approved make complete with 5 Amp switch, three speed regulator including indicator lamp complete all as specified and directed.
77Supply & fixingin repairs GI wire mesh for desert cooler pad (Set of Three).
78Supply & fixing in repairsPVC pipe for connecting pump and water distributor of size 15 mm complete all as specified & as directed.
79Supply & fixingin repairsPVC elbow for desert cooler of suitable size complete all as specified & as directed.
80Supply & fixingin repairs PVC 4 Way distribution cross for desert cooler complete all as specified & as directed.
81S&Fin repairs flexible copper conductor cable, 3 corePVC insulated & PVC sheathed of size 1.5sqmm complete all as specified and directed.
82S&F in repairs desert coolers fan blade of 18 inch sweep of plastic bodycomplete all as specified & as directed..
83All as per item No 43 here-in-before but 20 inch sweep.
84Supply and fixing in repairs side panel of desert cooler of 20” sweep made out with GI sheet of 20 SWG duly painted with two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer complete all as specified & as directed.
85Supply and fixing in repairs switch piano flush type single pole one way 5 Amp/ 6 Amp 230 V for desert cooler all as directed.
86Supply and fixing in repairs 3 pin plug top 5 Amp, 230V for desert cooler complete all as specified and directed.
87Supply and fixing in repairs 3 pin plug top 15 Amp, 230V for desert cooler complete all as specified and directed.
88Supply and fixing in repairs cooler fan motor bracket sets made up as existing includingpaintingcomplete all as specified and directed.
89S&F in repairs desert cooler body of size 25 inch x 25 inch x 36 inch (height) with side panels (03 Nos) fabricated out of 18 SWG PGI Sheet alongwith PVC front grill, distribution switch, 5 Amp piano switch and tank of depth 11 inch. Painting the complete desert cooler i.e, side panel, bracket body with two coat of synthetic enamel paint (Ist grade quality) over a coat of red oxide zinc chrome primer and two coat of black water proof paint on reserve tank and marking with "GE E/M BHDC" letter size of 50mm height in stencil in black/white all as specified and directed by Engr-in-Charge.
90Disconnecting from mains and taking downfor servicingof Aqua guard and RO water purifier of Capacity 20 to 50 LPH including detecting the leakage of water and refilling,cleaning of unserviceable items including checkingthe serviceability of electrical/electronic circuits relays, wiring kit, etc., andkeepingthe Aqua guard and RO system unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed by Engr-in-Charge. Note:-Replacement of defectivespares for making the Aqua Guard and RO units in satisfactory working condition will be measured & paidseparately under relevant items as "Supply only" and Labour charges for taking out old spares and fixingof new sparesshall deemed to be included in unit rate quoted.
91Supply onlyfollowing new spare parts of Aqua guard and RO water purifier of 20 to 50 LPH capacity:-
92Circuit plate PCB for RO water purifier. (Make:-Kent/ Aquaguard/ Aquasure/ Livpure.)
93Compact switch for RO water purifier. (Make:-Kent/ Aquaguard/ Aquasure/ Livpure.)
94Carbon block for RO water purifier. (Make:-Kent/ Aquaguard/ Aquasure/ Livpure.)
95Candle filter for RO water purifier. (Make:-Kent/ Aquaguard/ Aquasure/ Livpure.)
96Cuno candle for RO water purifier. (Make:-Kent/ Aquaguard/ Aquasure/ Livpure.)
97SV valve for RO water purifier. (Make:-Kent/ Aquaguard/ Aquasure/ Livpure.)
98UV tube for RO water purifier. (Make:-Kent/ Aquaguard/ Aquasure/ Livpure.)
99Membrane for RO water purifier. (Make:-Kent/ Aquaguard/ Aquasure/ Livpure.)
100Pump K48 for RO water purifier. (Make:-Kent/ Aquaguard/ Aquasure/ Livpure.)
101Adopter 48/24 volts for RO water purifier. (Make:-Kent/ Aquaguard/ Aquasure/ Livpure.)
102SS fittings (diverter valve) for RO water purifier. (Make:-Kent/ Aquaguard/ Aquasure/ Livpure.)
103Sediment filter for RO water purifier. (Make:-Kent/ Aquaguard/ Aquasure/ Livpure.)
104Carbon filter (Impoted) for RO water purifier. (Make:-Kent/ Aquaguard/ Aquasure/ Livpure.)
105Adopter 36/24 volts for RO water purifier. (Make:-Kent/ Aquaguard/ Aquasure/ Livpure.)
106Adopter kent 24 volts SMPS for RO water purifier. (Make:-Kent/ Aquaguard/ Aquasure/ Livpure.) Note for item No 52.01 to 52.15:- Materials of item No 52.01 to 52.15 to be incorporated in item No 51 here-in-before.
107Supply and fixing in repairs of 15mm dia PTMTball valve high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (Minimum weight 142 gms)complete all as specified and directed.
108Supply only in replacement PVC insulated, multi stranded, 3 core, flexible, copper conductor cable, of size 70 x 0.0076 complete all as specified and as directed.
109Supply only in replacement PVC insulated, multi stranded, 3 core, flexible, copper conductor cable, of size 40 x 0.0076 complete all as specified and as directed.
110Supply only in replacement flexible copper conductor cable 4.0 Sqmm, 3 core, PVC insulated & PVC sheathedcomplete all as specified and directed.
111M&L in repair sub main wiring with 2 runs of 4.0 Sqmm single core, PVC insulated & unsheathed (FR) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 4.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 4.0 Sqmm cable and one run of 4.0 Sqmm earth conductor along with 25 mm PVC conduit with accessories shall be measured as one length)
112Taking down the air curtain of any size and dismantling the various parts and carry out the servicing, lubricating and renewal of minor parts and replacing the defective parts and painting, refixing back to the new or old position with grouting materials complete all as specified and directed. (Note: Defective major parts except minor items shall be measured and paid for separately as "Supply only" under respective item of this Schedule.)
113Supply only blower motor of air curtain, existing capacity and model complete all as specified and as directed.
114Supply only blower drum of air curtain, existing capacity and model complete all as specified and as directed.
115Supply only bearing of air curtain, existing capacity and model complete all as specified and as directed.
116Supply only PVC flap of air curtain, existing capacity and model complete all as specified and as directed.
117Supply only motor housing of air curtain, existing capacity and model complete all as specified and as directed.
118S&F in replacement indoor unit complete set, suitablefor 1.5 TR split AC of existing make & model, consisting of blower motor, blower, wiring kit complete with display and electronic card and remote assembly, cooling coil, remoting system, plastic housing with bracket frame etc except compressor suitable for Non CFC gases all as specified and as directed.
119S&F in replacement indoor unit complete set, suitablefor 2.0 TR split AC of existing make & model,consisting of blower motor, blower, wiring kit complete with display and electronic card and remote assembly, cooling coil, remoting system, plastic housing with bracket frame etc except compressor suitable for Non CFC gases complete all as specified and as directed.
120S&F in replacement outdoor unit complete set, suitablefor 1.5 TR split AC of existing make & model,including condenser coil, blower motor, chassis, base plate complete set except compressor complete all as specified & as directed.
121S&F in replacement outdoor unit complete set, suitablefor 2.0 TR Split AC of existing make & model,including condenser coil, blower motor, chassis, base plate complete set except compressor complete all as specified & as directed.
122Supply and fixingin replacement 1.5 TR Capacity Window type Air Conditioner kit including condenser coil, blower motor, chassis, base plate complete set except compressor complete all as specified & as directed.
123Supply and fixing in replacement 2.0 TR Capacity Window type Air Conditioner kit including condenser coil, blower motor, chassis, base plate complete set except compressor complete all as specified & as directed.
124M&L for servicing of window type AC of 1.0/1.5/2.0 TR capacity, of any type/make, at site /wall, comprising of taking down carefully, removing power connections and front PVC grills, air filters, cleaning, washing, removing dirt, servicing including chemical wash of cooling coil, indoor cooling unit and condenser coil and providing oil and grease to all moving parts including condensing motor, checking and making serviceable electrical connection of DB"s, stabilizer, wiring of AC"s as per site condition and tightening all electrical connection with thimble and replacing the spare parts of the AC units wherever required, testing & commissioning including refixing at the original position and connecting with the system complete all as specified and as directed. Note:- Contractor shall maintain register of servicing as per format given by Engr-in-Charge duly signed by User, where the servicing of equipment carry out and produce as & when asked by Engr-in-Charge or GE BHDC.
125M&L for servicing of split type AC of 1.5/2.0 TR capacity, of any type/make, at site /wall, including removing power connections and front PVC grills, air filters, cleaning, washing, removing dirt, servicing including chemical wash of cooling coil, cooling unit and condenser coil of outdoor unit, checking and making serviceable electrical connection of DB"s, stabilizer, wiring of AC"s as per site condition and tightening all electrical connection with thimble and replacing the spare parts of the AC units wherever required, testing & commissioning including refixing at the original position and connecting with the system complete all as specified and as directed. Notes:- (i) The cost of additional inlet/outlet copper pipes, drain pipe and electrical cord, if required and making good of surface as original by plastering/ whitewash/ colour/ distemper etc shall deemed to be included in quoted rate and no extra payment shall be made to contractor on this account. (ii) Contractor shall maintain register of servicing as per format given by Engr-in-Charge duly signed by User, where the servicing of equipment carry out and produce as & when asked by Engr-in-Charge or GE BHDC.
126All as per srl item No 71.00 here-in-before but Tower type split AC of any capacity complete all as specified and as directed.
127Supply, installation, testing and commissioningin replacement complete indoor unitfor tower type split AC of 3.0 TR, inclusive ofblower motor, blower, wiring kit with cooling coil etc,suitable for R-22 Gas, includingsheet metal enclosure (DB),terminal etc including all copper tubing of required size & electrical cabling all as required as per site complete all as specified and directed.Make:Carrier/ Blue star/LGIndoor Unit Technical specification- Nominal cooling cap -3.0 TR, Performance rating-36000 BTU/Hr, Indoor fan motor-300 watt, Indoor air flow-1700 Cum/hr, Dimension(WXDXH): 540x410x1825. Gross weight: 70 KG, Operating temp.- >17 °C, Controller-Remote Control.
128Supply, installation, testing and commissioningin replacement complete indoor unitfor tower type split AC of 3.5 TR, inclusive ofblower motor, blower, wiring kit with cooling coil etc,suitable for R-22 Gas, includingsheet metal enclosure (DB),terminal etc including all copper tubing of required size & electrical cabling all as required as per site complete all as specified and directed.Make:Carrier/Blue star/LG Indoor Unit Technical specification- Nominal cooling cap -3.5 TR, Performance rating-42000 BTU/Hr, Indoor fan motor-300 watt, Indoor air flow-1700 Cum/hr, Dimension(WXDXH): 540x410x1825. Gross weight: 70 KG, Operating temp.- >17 °C, Controller-Remote Control.
129Supply, installation, testing and commissioningin replacement complete outdoor unit for Tower type split AC of 3.0 ton, except compressor, suitable for R-22 Gas,condenser coil, wiring kit , condenser fan motor, condenser fan, terminal etc also making platform for outdoor unit with suitable size of fastener and MS frame work and making good the disturb surface including all copper tubing of required size, control wiring all as required as per site complete all as specified and directed.Make: Carrier/blue star/LG Outdoor Unit Technical specification- Power Supply- 3 phase, 380 Volt, 50 Hz, Outdoor fan motor-290 watt, Fan motor speed-830 RPM, Dimensions(WXDXH): 990X345X965, Gross weight - 93 KG, Refrigerant piping-Max pipe lenght-20 mtr, Max difference in level-10 mtr.
130Supply, installation, testing and commissioningin replacement complete outdoor unit for Tower type split AC of 3.5 ton, except compressor, suitable for R-22 Gas,condenser coil, wiring kit , condenser fan motor, condenser fan, terminal etc also making platform for outdoor unit with suitable size of fastener and MS frame work and making good the disturb surface including all copper tubing of required size, control wiring all as required as per site complete all as specified and directed.Make: Carrier/blue star/LG Outdoor Unit Technical specification- Power Supply- 3 phase, 380 Volt, 50 Hz, Outdoor fan motor-290 watt, Fan motor speed-830 RPM, Dimensions(WXDXH): 990X345X965, Gross weight - 93 KG, Refrigerant piping-Max pipe lenght-20 mtr, Max difference in level-10 mtr.
131Note for Item Nos 73.00 To 76.00:-Old taking down outdoor unit of any capacity and size shall be deposited to MES store yard from existing location. The rate include necessary transportation & Manpower to dismantling and transporting the unit.
132Supply and charging R-22 refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage in summer appliances all as specified and as directed.
133Supply and charging R-134A refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage in summer appliances all as specified and as directed.
134Supply and charging R-410A refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage in summer appliances all as specified and as directed.
135Attending the complaints for Water heater geyser of Capacity 25/ 35/ 50 Ltrs at different location of Base Hosp area including tracing & rectify the fault ofsystem, incl checking incoming/outgoing hot & cold water supply connection, electric connection of geysers including replacement of unserviceable parts complete all as specified and as directed. Note: The spare parts required for repairs shall be measured and paid separately as "Supply only" under respective item of this Schedule.
136Taking down the geyser from its existing position for general cleaning/overhauling and descaling the tank and assembly with suitable detergent and making fully serviceableand refixing in new/old position complete with testing complete all as specified and as directed. Note: (i) Item No 80.00 here in before shall not be payble where this item is executed.(ii) The spare parts required for repairs shall be measured and paid separately as "Supply only" under respective item of this Schedule.
137Supply only fusible plug type (pressure valve) Air release valve complete all as specified and as directed.
138Supply only air release valve (Nozzle) as per sample complete all as specified and as directed.
139Supply only gasket of thickness 5 mm for geyser assembly of 06 holes/ 08 holes/ 09 holes complete all as specified and as directed.
140Supply only Syphon assembly ofcopper, 06 holes with nut bolts/stud/washer complete all as specified and as directed.
141Supply only indicating lamp green/ redfor geyserrectangular type/round type complete all as specified and as directed.
142Supply only inner shell of Geyser of cap 25 Litre made out of steel tank complete all as specified and as directed.
143All as per Srl item No 87.00 here-in-before but for 35 Litre Capacity complete all as specified and as directed.
144All as per Srl item No 87.00here-in-before but for 50 Litre Capacity complete all as specified and as directed.
145Supply only outer body of Geyser Capacity 25/ 35/ 50 Litre of 20 SWG MS Sheet and woolen glass duly painted complete all as specified and as directed.
146Supply only thermostat switch of geysers (adjustable type) temp range 35 Degree Celsius to 75 degree Celsius complete all as specified & directed.Make- THEETA/BAJAJ/RECOLD/DASPASS
147Supply only heating element 1.5 KW (round type) with rubber gasket complete all as specified & directed.Make- Theeta/Bajaj /Recold/ DASPASS (As per sample)
148All as per item No. 92.00 here-in-before but round type 2 KW complete all as specified & directed. (As per sample)
149All as per item No. 92.00 here-in-before but triangle type1.5 KW complete all as specified & directed. (As per sample)
150All as per item No. 92.00 here in before but triangle type 2 KW complete all as specified & directed. (As per sample)
151Supply only 15mm size PVC connection pipe 600mm longheavy duty with brass nut for hot/cold water complete all as specified & directed.
152Supply only 15mm size PVC connection pipe 450mm longheavy duty with brass nut for hot/cold water complete all as specified & directed.
153Supply only brass chromium plated angle valve suitable for 15 mm bore pipe complete all as specified and as directed.
154Supply only 15mm size brass CP extension nipplecomplete all as specified & directed.
155Supply only 15 mm size Brass CP Angle valve 2 in 1 complete all as specified & directed.Make-Zim/ Parko/Kingston)
156S&F dash fastener mild steel 150 mm long x 10 mm dia with pin and bolts complete for hanging of geyser properly on wall and making good to the disturbed surfaces including plastering and white washing complete all as specified and as directed.
157Taking down geyser from existing location, preparation of body of geyser by knotting and stopping of outer surface, repainting the complete outer surface of geyser with one coat of synthetic enamelled paint 1st qualityand refixing the same on wall in existing location and writing "GE E/M BHDC" of letter size 10 mm complete all as specified and as directed.
158M&L for unscrewing the nut bolt and taking out the base plate geyser assembly andcopper tank making soldering and brazing of tank to stop the leakage of tank and fixing back in the positioncomplete all as specified & directed.
159S&F in repair 5 star rated vertical mounted Water heater geyser of capacity 25ltrs havingFeatures: outer body-ABS, Safety feature-Multi function safety valve, thermostat, thermal cut-out, vitreous enamelled glass line tank with CRCA outer body with powder coated with heavy duty anode rod prevent from corrosion & permanent scaling with adjustable knob for temp setting between 30°C to 75°C, high density PUF for thermal insulationwith LED power indication.Technical specifications: voltage-230V, Type-storage, Frequency-50Hz, Wattage- 2 Kilo Watts,Pressure-8 Bar, Pressure Class- Class 1 complete all as specified & directed. Note- Old unserveciable geyser of any capacity shall be deposited at MES store yard for further disposal.
160S&F in repairs PVC insulated unsheathed copper wire of size 1.50 Sqmm 3 run drawn in and including 20mm dia medium grade PVC conduit complete all as specified & directed. Note: 03 run of Copper cable 1.50 Sqmm along with 20 mm PVC conduit shall be measured as one length.
161Supply only in replacement sheet metal enclosure with 01 No MCB SP 25 Amp, 240 Volt, 3 pin Metal clad top and metal clad socket 20 Amp complete all as specified and as directed.
162S&F in repair MCB SP 240 Volts, 20 to 63 Amps complete all as specified and directed.
163Supply only in replacement Syphon assembly ofcopper, 09 holes with nut bolts/stud/washer complete all as specified and as directed.
164Supply only thermostat cut out of geysers (adjustable type) temp range 35 Degree Celsius to 75 degree Celsius complete all as specified & directed.Make- THEETA/BAJAJ/RECOLD/DASPASS
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail