}

Tender For Repair/Maintenance Of Geyser, Ceiling Fans, Exhaust Fans, Electric Wiring, Internal Fixture And Misc Items At Adm Site (Bhowali) And Ops Site (Lkt) At Af Station Bhowali., bhowali-Uttarakhand

Military Engineer Services has published Tender For Repair/Maintenance Of Geyser, Ceiling Fans, Exhaust Fans, Electric Wiring, Internal Fixture And Misc Items At Adm Site (Bhowali) And Ops Site (Lkt) At Af Station Bhowali.. Submission Date for this Tender is 05-01-2023. Paint System Tenders in bhowali Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

35337638
Corrigendum : Tender For Repair/Maintenance Of Geyser, Ceiling Fans, Exhaust Fans, Electric Wiring, Internal Fixture And Misc Items At Adm Site (Bhowali) And Ops Site (Lkt) At Af Station Bhowali.
Tender
Indian
Uttarakhand
Bhowali
05-01-2023

Tender Details

Tender For Repair / Maintenance Of Geyser, Ceiling Fans, Exhaust Fans, Electric Wiring, Internal Fixture And Misc Items At Adm Site ( Bhowali ) And Ops Site ( Lkt ) At Af Station Bhowali. - Taking down carefully to existing copper/Aluminum point wiring (light,fan, socket or power) complete includingfittings such as switches, ceiling roses, pendents, regulators sockets, light fitting etc removiing materials to keeping in safe custody for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. complete all as specified and directed. 2 M & L for point wiring using approved colour code as per IS (Red, Black and Green for single phase circuits)with multistrand copper conductor 1.5 sq mm nominal cross-sectional area, single core,PVC insulated and unsheathed FR-LSH cable 1100 Volts grade ISI-694 marked with valid CM/L No. drawn inconcealed PVC rigid non metalic conduit of size 20mm dia, including replacement of mild steel/pressed steel sunken box and outer sheet and provn of fixed concealed sunken box with inner & outer cover incl all screw,cup washer used to brass etc including PVC insulated multi-stranded copper conductor 1.5 sqmm nominal cross sectional area single core FR-LSH cable as earth continiuty conductor to common earth and connecting to earth dolly complete forlight/Ceiling fan/Ex-fan point controlled by one 5/6 amps one way switch complete all as specified and directed. (Note:modular and normal Switch /socket and fan regulator deem to be measured and paid seperatly in respective items). 3 All as per item No 2.00 here-in-before but for socket point, 5 Amp 230 Volt on same board. Make- Finolex/Havells/Polycab/RPG. 4 All as per item No 2.00 here-in-before but for one socket point outlet3 Pin, 5 Amp 230 Volt on independent board. Make- Finolex/Havells/Polycab/RPG. 5 All as per srl item No. 2.00here-in-before but for call bell point. Make- Finolex/Havells/Polycab/RPG. 6 All as per srl item No. 2.00here-in-before but forOne light point controlled by two, twoway switch.Make- Finolex/Havells/Polycab/RPG. 7 AllaspersrlitemNo.2.00here-in-before but for 3 pin 15 Amp socket out let by using 2.5 Sqmm PVC insulated unsheathed copper conductor cable FR-LSH multi strand on independent boardincluding provn of2.5 Sqmm unsheathed, multi strandedcopper conductor cable FR-LSH continues as earth wire connected to earth dolly etc complete all as specified and directed by Engineer-in-Charge.Make- Finolex/Havells/Polycab/RPG. 8 M & L for point wiring using approved colour code as per IS (Red, Black and Green for single phase circuits)with multistrand copper conductor 1.5 sq mm nominal cross-sectional area, single core,PVC insulated and unsheathed FR-LSH cable 1100 Volts grade ISI-694 marked with valid CM/L No. drawn inPVC casing & caping, including replacement of mild steel/pressed steel sunken box including outer sheet and fixed concealed, covered etc including PVC insulated multi-stranded copper conductor 1.5 sqmm nominal cross sectional area single core FR-LSH cable as earth continiuty conductor to common earth and connecting to earth dolly complete for one light/Ceiling fan/Ex-fan point controlled by one 5/6 amps one way switch complete all as specified and directed. (Note: Switch /socket and fan regulator deem to be measured and paid seperatly in respective items). 9 All as per item No 8.00 here-in-before but for one socket point outlet3 Pin, 5 Amp 230 Volt on independent board. 10 AllaspersrlitemNo.8.00here-in-before but for 3 pin 15 Amp socket out let by using 2.5 Sqmm PVC insulated unsheathed copper conductor cable FR-LSH multi strand on independent boardincluding provn of2.5 Sqmm unsheathed, multi strandedcopper conductor cable FR-LSH continues as earth wire connected to earth dolly etc complete all as specified and directed by Engineer-in-Charge. 11 S& F switch piano flush type, 6 Amp 240 Volt, AC(ISI Marked) one way etc complete all as specified and directed by Engineer-in-Charge. 12 S&F Socket outlet 5 Pin 6 Amp 230 volts AC (ISI Marked)etc complete all as specified. Note:- Switch and socket shall be of same make. 13 S&F Socket outletmultipurpose 3 Pin 5 Amp and 6 Pin 15 Amp 230 volts AC ncluding decorative frame cover etc complete all as specified. Note:- Switch and socket shall be of same make. 14 S& F switch piano flush type, 15 Amp 240 Volt, AC(ISI Marked) one way etc complete all as specified and directed by Engineer-in-Charge. 15 S&F Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed by Engineer-in-Charge. 16 S&Fbell push, 5 Amp, 230 V, AC etc complete all as specified and directed by Engineer-in-Charge. 17 S&F call bell dingtype, AC, 230 V etc complete all as specicied and directed by Engineer-in-Charge. 18 S&Fceiling rose surface bakelite 65mm x 50mm, 2 to 3 terminalswith back plate etc complete all as specified and directed by Engineer-in-Charge. 19 S&F batten holder of PVC / Polycarbonate type surface including 9W LED bulb etc complete all as specified and directed by Engineer-in-Charge. 20 S & F in replacement of sub main two single core PVC copper conductor unsheathed wiremulti stranded 4 sqmm including cutting chasing and grouting PVC pipe concealed including Tee, Elbow, Bend etc andincluding 4.0 sqmm copper conductor single core wire connected by common earth all as specified. Including 20 mm dia PVC conduit, medium grade, ISI marked complete all as specified and directed. 21 S & F in replacement of sub main two single core PVC copper conductor unsheathed wiremulti stranded 6 sqmm including cutting chasing and grouting PVC pipe concealed including Tee, Elbow, Bend etc andincluding 6.0 sqmm copper conductor single core wire connected by common earth all as specified. Including 20 mm dia PVC conduit, medium grade, ISI marked complete all as specified and directed. 22 S & F in replacement of sheet metal enclosuret double door TPNDB 4 way (cAT PART No 607705 of Legrand or having same specification in L&T, SCHNEIDER OR C & S), 415 V with neutral and earth link and 200 rated bus bar, ip-20 protection,with neutral bar, Earth bar and cables ties for cable management fully insulated bus bar and complete made out of CRCA steel sheet factory made complete all as specified and directed. 23 S & F in replacement of sheet metal enclosure double door 8 way SPN DB (cAT PART No 607711 of Legrand or Cat part No A9HSND08 OF SCHNEIDER or C & S,230 V with neutral and earth link and 200 rated bus bar complete made out of CRCA steel sheet factory made complete all as specified and directed. Make cat Pt No 854DD of SSK or equivalent Havells/ABB/Legrand. 24 S & F in replacement of sheet metal enclosure double door 4 way SPN DB (cAT PART No 607710 of Legrand or Cat part No A9HSND04 OF SCHNEIDER or C & S, 230 V with neutral and earth link and 200 rated bus bar complete made out of CRCA steel sheet factory made complete all as specified and directed. Make cat Pt No 854DD of SSK or equivalent Havells/ABB/Legrand. 25 S & F in replacement of MCB TPN63Amp, 415 VoltC curved, multi-breaking capacity not less than 10 KA with over load and short circuit protection,complete all as specified and as directed by Engr-in-Charge. MAKE- LEGRAND/L&T/SCHNEIDER OR C & S 26 S & F in replacement of MCB SPN63Amp, 230VoltC curved, multi-breaking capacity not less than 10 KA with over load and short circuit protection,complete all as specified and as directed by Engr-in-Charge. MAKE- LEGRAND/L&T/SCHNEIDER OR C & S 27 S & F in replacement of MCB SPN40 Amp, 230VoltC curved, multi-breaking capacity not less than 10 KA with over load and short circuit protection,complete all as specified and as directed by Engr-in-Charge. MAKE-LEGRAND/L&T/SCHNEIDER OR C & S 28 S & F in replacement of MCB SP 5-32 Amp 240 V, C Series, multi-breaking capacity of 10 KA with over load and short circuit protection, 1 module complete all as specified and as directed by Engr-in-Charge. MAKE-LEGRAND/L&T/SCHNEIDER OR C & S 29 S & F in replacement of sheet metal enclosure with two pin and earth plug and Socket with metal top 230 V with one single pole MCB of 20 Amp complete all as specified and directed. Make - SSK or equivalent Havells/ABB/Legrand. 30 S&F in repair one switch & one socket outlet 5 Pin 5 Amp 230 volts AC complete all as specified. Note:- Switch and socket shall be of same make. 31 S&F in repair one switch and one socket outletmultipurpose 3 Pin 5 Amp and 6 Pin 15 Amp 230 volts AC complete all as specified. Note:- Switch and socket shall be of same make. 32 S & F in repair modular type switch, 6/10 Amps 240 Volts, AC (ISI Marked) single module one way etc complete all as specified and directed.Make- Anchor(ROMA/PENTA) /Havells/Legrand. 33 S & Fin repair modular type switch, 16/20 Amps 240 Volts, AC (ISI Marked) single module one way etc complete all as specified and directed. Make- Anchor(ROMA/PENTA) /Havells/Legrand. 34 S & Fin repair modular type switch, 6/10 Amps 240 Volts, AC (ISI Marked) single module Bell push etc complete all as specified and directed. Make- Anchor(ROMA/PENTA) /Havells/Legrand.. 35 S & Fin repair modular type 5 pin socket, 6/10 Amps 250 Volts, AC with shuttered (ISI Marked) two moduleetc complete all as specified and directed.Make- Anchor(ROMA/PENTA) /Havells/Legrand.. 36 S & Fin repair modular type 6 pin socket, 16/20 Amps 240 Volts, AC with shuttered (ISI Marked) two moduleetc complete all as specified and directed.Make- Anchor(ROMA/PENTA) /Havells/Legrand. 37 S & Fin repair modular type Fan regulator 0-5 steps socket size 100 W hum free, 240 Volts, AC (ISI Marked) two module etc complete all as specified and directed. Make- Anchor(ROMA/PENTA) /Havells/Legrand. 38 S & F in repair of white cover plate with frame, 2 module suitable for modular type switches complete all as specified and directed by Engr-in-Charge 39 S & F in repair of white cover plate with frame, 3 module suitable for modular type switches complete all as specified and directed by Engr-in-Charge 40 S & F in repair of white cover plate with frame, 4 module suitable for modular type switches complete all as specified and directed by Engr-in-Charge 41 S & F of white cover plate with frame, 8 module suitable for modular type switches complete all as specified and directed by Engr-in-Charge 42 S & F in repair metal flush box 1/2 module complete all as specified and directed by Engr-in-Charge 43 S & F in repair metal flush box 3 module complete all as specified and directed by Engr-in-Charge 44 S & F in repair metal flush box 4 module complete all as specified and directed by Engr-in-Charge 45 S & F in repair metal flush box 6 module complete all as specified and directed by Engr-in-Charge 46 S/F in replacement of LED batten fitting T-8 Retro LED 1 x 20Watt, 6000K, 4 complete with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly,energy efficient complete with all light fitting connection with 2 core flexible cable 23/0.00076 from ceiling rose to tube fitting connection etc complete all as specified and directed by Engineer-in-charge. Make - Cat pt No LHEXARP7SN1W020 of Havells or equivalent to Bajaj/Crompton 47 S/F in replacement of LED mini mirror fitting1 x 10Watt, 6000K, 2 complete with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly,energy efficient complete with all light fitting connection with 2 core flexible cable 23/0.00076 from ceiling rose to tube fitting connection etc complete all as specified and directed by Engineer-in-charge. Make- Cat pt No LHEXACP7IN1W010 of Havells or equivalent to Bajaj/Crompton 48 S & F modular type blanking plate, 240 Volts, AC (ISI Marked) one module etc complete all as specified and directed. Make- Cat Pt No GR.1032 of SSK or equivalent to Havells/Crabtree/Legrand. 49 Supply and fixing surface mounted LED ceiling mounted 230V, AC system wattage 12 Watt, 6000K, LED light fitting should not be more than 5 watt± 10% surge protection of minimum 2KV power factor should be more than 0.90, cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 540 lumens, total input voltage range 140-280V AC, colour rendering Index should not be less than 80 complete incl electrical connection all as specified and directed. including connecting electric connection complete all as specified and directed. Make- Crompton/Bajaj/Havells. 50 Supply and fixing wall mounted decorative wall light, brushed nicked finish fixture with acrylic diffuser including LED 9 watts lamp, base B22, complete fitting and all other fixing accessories incl including electric connection connecting with using flexible copper wire twin core incl. taking down old unserviceable light fitting and type complete all as specified and directed. Make Cat Pt No LHFOAJE1TN1/060 of HAVELLS or equivalent to Bajaj/Crompton. 51 S/F in replacement of LED batten fitting with square profile and polycarbonate channel, lithium Ion battery with charging time 8 hours to 10 hours and back up time upto 4 hours, T-8 Retro LED 1 x 20Watt, 6000K, 4 complete and environment friendly,energy efficient complete with all light fitting connection with 2 core flexible cable 23/0.00076 from ceiling rose to tube fitting connection etc complete all as specified and directed by Engineer-in-charge. Make - Havells cat part No LHEXARP7SN1W020 or equivalent to Bajaj/philips 52 S&F in replacement of LED building security light fitting, 1X30 wattcomplete with tuff net glass IP:66 with provn of suitableGI bracket made out of suitable size of light grade pipeupto 1.2 mtr length bent to shape fixed with wall, MS clamps 02 Nos suitable for security light fitting to wall/colum and electric connection to the light fitting copper conductor of size 1.5 sqmm twin core as per site requirement complete all as specified and directed. Make Cat Pt No. LHEXACP7FNW020 of HAVELLS/CROMPTON/Bajaj. 53 S & F of LED bulk head fitting energy saving new generation 10W LED enclosed with poly corbonate cover 6000K with IP 65 protection, the system wattage of fitting should not be more than 5 watt ± 10%, surge protection of minimum 2KV power factor should be more than 0.90, cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 900 lumens, total input voltage range 140-280V AC, colour rendering Index should not be less than 80 complete incl electrical connection all as specified and directed. Make- Havells/Philips/C&S 54 S & F in repairs LED type 18 Watt capacity, 230 volts, ultra bright PL-L photon ultra LED tube lamp with very high efficiency suited for installation in existing 2G11 lamp holders as per Cat. Part No. PHOTONULTRAPLL 419TL18WLED865SPC of Havells or having same or superior specifications in Philips complete all as specified and directed. 55 S & F of LED type flat panel ceiling light fitting 42 Watt capacity ultra modern designed architectural which provides soft light and glare free illumination suitable for 2x2 ceiling grid as per Cat. Part No. VENUSNEOHE2X2PLR18-42WLED865MOD (VENUS NEO HE 2X2) of Havells or having same or superior specifications in Philips duly pre-fitted with all accessories with and including taking down old ceiling light fitting any type and description complete all as specified and directed. 56 S & F in repairs electronic driver for LED type flat panel ceiling light fitting 42 Watt capacity as per Cat. Part No. LEDDRIVER36V42WS of Havells or having same or superior specifications in Philips duly pre-fitted with all accessories complete all as specified and directed. 57 S&F in replacement of LED Flood Light fitting, 1X50 wattcomplete with tuff net glass IP:66 with and electric connection to the light fitting copper conductor of size 1.5 sqmm twin core as per site requirement complete all as specified and directed. Make Cat Pt No. LHEECNP7PB6J050 of HAVELLS/CROMPTON/Bajaj. 58 M & Lfor earthing with galvanized steel earth plate electrode 600x600x6mm size burried directly in ground to depth not less than 2.25M below ground level with top edge of the plate not less than 1.5 mtr below normal ground level surrounded with char coal and common salt filling in alternative layers of 15cm thick and connected to GI earth wire 4 mm dia by means of nuts/bolts and washers etc made out of galvanized iron including 15mm dia GI pipe light grade for protection of earth wire from earth to distribution board 20mm dia GI pipe medium grade connected to funnel heavy wire mesh for watering purpose including necessary excavation and earth work PCC (1:2:4) type B1 for concrete pit 10mm thick PCC slab cover frame all as specified and shown in electric plate Nos 3/ SSR Pt-I and testing on completion including old replacement complete all as specified and directed by Engineer-incharge. Note: Test report of earthing not less than 1 Ohm carried out after completion of earth pit if found less contractor execute the same for another place as per direction of Engineer-in-charge. 59 M&L for collecting unserviceable ceiling fans 1200mm sweep 230 V, AC, single phase from store yard of AGE E/M, opening the ceiling fan and taking out complete burnt winding from fan motor and rewinding the same with super enameled copper winding wire of existing gauge & size including thoroughly cleaning all the components of fan, oiling varnishing the fan with and including replacement of rusted/unserviceable nuts, bolts, split pin, rubber reel, flexible twin core copper cable of size 23/.00076 approximate one metre long for each fan, machine screws etc, depositing the repaired fan to store yard complete all as specified and directed by Engineer-in-charge. 60 All as per item No.1 here-in-before but exhaust fan of size 450 mm sweep of any make & type / model complete all as specified and directed by Engineer-in-charge. 61 All as per item No.1 here-in-before but exhaust fan of size 300 mm sweep of any make & type/model complete all as specified and directed by Engineer-in-charge. 62 All as per item No.1 here-in-before but exhaust fan of size 225 mm sweep of any make & type/model complete all as specified and directed by Engineer-in-charge. 63 All as per item No.1 here-in-before but wall mounting fan of any sweep / make & type/ model complete all as specified and directed by Engineer-in-charge. 64 All as per item No.1 here-in-before but for Air Circulator, Pedestal fan of size 600mm sweep complete of any type/model.Note For Srl No.1 to 8:- The rewinding shall be carried out in the AGE E/M Store Yard for which rent as per Clause No.16 of PSS-II will be deducted from contracators payment complete all as specified and directed by Engineer-in-charge. 65 Taking out defective capacitor and supply & fixing dry type capacitor of capacity 2.5 MFD suitable for any make and type of fan complete all as specified and directed by Engineer-in-charge. 66 All as per item No.9 here-in-before but of capacity 4 MFD complete all as specified and directed by Engineer-in-charge.Note For item No.9 & 10:- Capacitor shall be replaced in workshop as well as at site as per requirement. 67 Taking out the defected ball bearing of ceiling fans/ exhaust fans/ air circulator fans / cabin fans/ table fans/ pedestal fans and supply & fixing new ball bearing suitable for existing housing of No.6201, 6202 complete all as specified and directed by Engineer-in-charge. 68 Taking out the worn out Gun Metal Bush and supply and fixing new Gun metal bush of suitable size for any sweep and make of ceilingl fan/ exhaust fan/ pedestal fan / table fan / air circulator / cabin fan complete all as specified and directed by Engineer-in-charge. 69 Taking out the worn out / defective blades of ceiling fan of 1200 mm sweep and supply & fixing new aluminium blade of same size in set of three alongwith fixing screws and spring washers complete all as specified and directed by Engineer-in-charge. 70 Painting of ceiling fan of size 1200/1400mm of any make including preparation surface and making smooth the surface of body, blade, down rod etc even and smooth/fair for painting one coat of white synthetic enamel paint with spray gun complete all as specified and directed by Engineer-in-charge. 71 Painting of Exhaust fan of size 225 to 450mm of any make including preparation surface and making smooth the surface of body, blade, od etc even and smooth/fair for painting one coat of grey synthetic enamel paint with spray gun complete all as specified and directed by Engineer-in-charge. 72 M&L for dismantling and taking down complete 25/35/50 ltr capacity geysers from site and brought to E/M store yard & Refixing the same after carrying out following works:-(i) complete cleaning and de-scaling of inlet and outlet connections, inner tanks, fittings, fixtures & outlet pipelines etc with suitable chemical agent.(ii) Complete servicing and maintenance (iii) Replacement of unserviceable spares as deemed necessary such as inner tank, outer cover, inner assembly, glasswool, rubber gaskets, nuts, bolts, clamps, etc., repair of minor leakages if any by carrying out minor welding/brazing.(iv)complete testing and to ensure proper functioning & maintaining proper water temparature.complete all as specified and directed.Notes : (a) Cost of minor spares such as chemical agents, rubber gaskets, nuts, bolts, clamps etc and minor welding/brazing deemed to be included in the quoted rate.(b) The cost for all major spares & items such as inner tank, outer cover, inner assembly, glasswool etc shall be paid in respective items separately. 73 Supply only inner tank made of stainless steel for geysers of capacity 25 ltr complete all as specified and directed. 74 Supply only inner tank made of stainless steel for geysers of capacity 50 ltr complete all as specified and directed. 75 Supply only outer body/cover suitable for 25ltr cap geyser made out of mild steel pre-treated and stove enamelled sheet of 18 SWG complete with top and bottom cover, rubber gasket, stead screw for fixing the top and bottom cover to outer body easing including two coat of white synthetic enameled paint over one coat of red oxide primer, complete all as specified and directed. 76 Supply only outer body/cover suitable for 50ltr cap geyser made out of mild steel pre-treated and stove enamelled sheet of 18 SWG complete with top and bottom cover, rubber gasket, stead screw for fixing the top and bottom cover to outer body easing including two coat of white synthetic enameled paint over one coat of red oxide primer, complete all as specified and directed. 77 Supply only Geyser inner assembly made of stainless steel for geyser of capacity 25/35/50 ltr having suitable numbers of slots & pipes provisions complete with rubber gasket & bolts for fixing completeall as specified and directed. 78 S&F in repair bottom inspection cover in two pieces made of minimum size 20 SWG GI sheet suitable for 25/50 ltrs capacity geysers of any make, inclusive of one red oxide primer coat, one under coat and one finishing coat ofwhite color paint complete on outer surface and inner surface, complete all as specified and directed. 79 S&F in repair top cover made of minimum 20 SWG size GI sheet suitable for 25/50 ltrs capacity geysers of any make, inclusive of one redoxide primer coat, one under coat and one finishing coat ofwhite color spray paint complete on outer surface and inner surface, complete all as specified and directed. 80 M&L for spray painting to geysers of capacity 25 ltrs with two coat of synthetic enamel white paint over one coat red oxide(primer) including scratching of old paint and making surface smooth by using filler etc complete all as specified and directed. 81 M&L for spray painting to geysers of capacity 50 ltrs with two coat of synthetic enamel white paint over one coat red oxide(primer) including scratching of old paint and making surface smooth by using filler etc complete all as specified and directed. 82 M&L in repairs for grouting the one set of bolts of suitable size including nuts (one set include four bolts and four nuts)in wall including taking down & refixing the existing geysers at site any make & size and making good the disturbed surface, complete all as specified and directed. 83 S&F in replacement heating element for geysers 1.5 KW 230V AC, 50 cycle, triangular/round type ISI marked complete with rubber gasket complete all as specified and directed. 84 S&F in replacement heating element for geysers 2.0 KW 230V AC, 50 cycle, triangular/round type ISI marked complete with rubber gasket complete all as specified and directed. 85 S&F in replacement thermostat ISI marked stem type 240 Volts, AC supply temp range 30 to 75 degree C for geyser/solar water heater system complete all as specified and directed. 86 S&F in replacement indicator lamp red/green colour 230 volts, AC, ISI marked suitable for geyser compete all as specified and directed. 87 S&F in replacement brass safety valve, ISI marked for geysers, complete all as specified and directed. 88 S&F in replacement PVC connection pipe wire braided of 15 mm dia 450 mm long, ISI marked temperature resistantsuitable for cold & hot water with brass nuts and rubber washers at both ends compelte all as specified and directed. 89 S&F in replacement PVC connection pipe wire braided of 15 mm dia 600 mm long, ISI marked temperature resistantsuitable for cold & hot water with brass nuts and rubber washers at both ends compelte all as specified and directed. 90 S&F in repair PVC insulated and round sheathed 3 core multistranded copper conductor FR cable of size 2.5sqmm 1100V ISI marked complete all as specified and directed. 91 S&F in repair plug top 3 pin 15/16 Amp ISI marked 250V for geyser cable complete all as specified and directed.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 29-12-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 12000.0 /-
Tender Value
INR 6 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail