Educational and Research Institute Government Departments Closing in 0 days TDR #35334242

Tender For Renovation Works At 3Rd Floor Block-A In The Existing Hospital Bulding At Aiims Bibinagar,Telangana

Issued by Government Departments · bibinagar, Telangana
Tender Value
1.19 Crore
Estimated cost
Bid Submission
12 Jan 2023
0 days left
EMD
2.39 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
bibinagar → Telangana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Renovation Works At 3Rd Floor Block-A In The Existing Hospital Bulding At Aiims Bibinagar, Telangana

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-Dec-2022 DATE CORRIGENDUM Date 02-Jan-2023
2 30-Dec-2022 EXTENSION OF DATE Date 05-Jan-2023
3 30-Dec-2022 EXTENSION OF LAST DATE Technical Bid 05-Jan-2023
4 05-Jan-2023 Date Corriendum Date 10-Jan-2023
5 10-Jan-2023 DATE EXTENSION Date 12-Jan-2023

BOQ

Name of Work:RENOVATION WORKS AT 3rd FLOOR BLOCK-A IN THE EXISTING HOSPITAL BULDING AT AIIMS BIBINAGAR,TELANGANA
Sl. No. Item Description
1Providing and laying cement concrete in retainingwalls,returnwalls,walls(any thickness)includingattachedpilasters, columns, piers, abutments,pillars,posts,struts, buttresses, string or lacing courses, parapets,coping,bedblocks,anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding thecost ofcentering,shutteringand finishing: 1:1½:3 (1 cement : 1½ coarse sand(zone-III):3gradedstone aggregate 20 mm nominal size).
2Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
3Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all completeaboveplinthlevel.Thermo- Mechanically Treated bars of grade Fe-500D or more.
4Providing and fixing sheet covering over expansion joints with iron screws as per design. Aluminium fluted strips 3.15 mm thick. 150 mm,
5Reinforced cement concrete work in beams,suspendedfloors,roofshaving slope up to 15° landings,balconies, shelves, chajjas, lintels, bands, plain windowsills,staircasesand spiral stair cases above plinth level up to floor five level, excluding the cost of centering,shuttering,finishingand reinforcementwith1:1.5:3(1cement:1.5 coars sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
6ProvidingandfixingIstqualityceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed ofcementmortar1:3(1cement:3 coarse sand) and jointing with grey [email protected], includingpointinginwhitecement mixedwithpigmentofmatchingshade complete.
7Providing wood work in frames of doors, windows,clerestory windowsand other frames,wroughtframedandfixedin position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Second class teak wood
8ProvidingandfixingISImarkedflush doorshuttersconformingtoIS:2202 (PartI) non-decorative type, core of blockboardconstructionwithframeof 1stclasshardwoodandwellmatched commercial 3 ply veneering with vertical grains or cross bands and face veneers on bothfacesofshutters: 35mm thick including ISI marked Stainless Steel butt hinges with necessary screws
9Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mmdiameterbolts,nutsandwooden plugsandembeddingincement concreteblock30x10x15cm1:3:6mix (1cement:3coarsesand:6graded stone aggregate 20mm nominal size).
10Providing and fixing M.S.grills of requiredpatterninframesofwindows etc.withM.S.flats,squareorround barsetc. includingprimingcoatwith approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
11Providing and fixing aluminium extruded section body tubular type universalhydraulicdoorcloser(having brandlogowithISi,IS:3564, embossedon the body, doorweight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
12Providingandfixingaluminiumsliding door bolts,Size of 300X 16 mmISI marked anodised (anodic coatingnotlessthangradeAC10as perIS:1868),transparentordyedto required colour or shade, with nuts and screws etc. complete
13Providingandfixingaluminiumtower bolts,Size of 250 X 10 mmISI marked, anodised (anodic coatingnotlessthangradeAC10as perIS:1868)transparentordyedto requiredcolour or shade, with necessaryscrews etc.complete.
14Providing and fixing aluminium handles,Size of 125 mm, ISImarked,anodised(anodiccoating notlessthangradeAC10asperIS: 1868)transparentordyedtorequired colour or shade, with necessary screws etc.complete
15Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper
16Providingandlaying rectified Glazed Ceramic floor tiles of size 300x300 mmormore(thicknesstobespecified by the manufacturer), of 1st qualityconformingto IS : 15622,of approved make,inallcolours,shades, exceptWhite,Ivory,Grey,FumeRed Brown,laidon20mmthickCement Mortar 1:4 (1 Cement : 4 Coarse sand), [email protected] kg/ sqm includingpointing the joints withwhitecementandmatching pigments etc., complete.
17Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08%and conformingtoIS:15622,ofapproved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement:4coarsesand),jointingwith [email protected]/sqm including grouting the jointswithwhitecementandmatching pigmentsetc.,complete.SizeofTile 600x600 mm.
18Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12mmthickbedofcementmortar 1:3 (1 cement: 3 coarse sand), jointing with [email protected]/sqm includinggroutingthejointwithwhite cement&matchingpigmentsetc. complete. Size of Tile 600x600 mm.
1912mmcementplasterofmix:1:4(1 cement: 4 coarse sand)
206mmcementplasterofmix:1:3(1 cement: 3 fine sand)
21White washing with lime to give an even shade : New work (three or more coats)
22Applyingonecoatofwaterthinnable cementprimerofapprovedbrandand manufactureonwallsurface:Water thinnable cement primer
23Wall painting with acrylic emulsion paint ofapprovedbrandandmanufactureto give an even shade : Two or more coats on new work
24Paintingwithsyntheticenamelpaintof approved brand and manufacture to give an even shade : Two or more coats on new work.
25Paintingwithsyntheticenamelpaintof approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinarypaintofapprovedbrandand manufacture.
26Providingandapplyingwhitecement based putty of average thickness 1 mm, ofapprovedbrandandmanufacturer, over the plastered wall surface to preparethesurfaceevenandsmooth complete.
27Demolishingbrick/solidblockwork manually/ bymechanical means including stacking of serviceable materialanddisposalofunserviceable materialwithin50metresleadasper directionof Engineer-in-charge.In cement mortar.
28Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres leadOf area3 sq. metres. Or below.
29Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead Of area beyond 3 sq. metres. Of area beyond 3 sq. metres.
30Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors,windows,ventilatorsand partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved makeconformingtoIS:733andIS: 1285, fixing with dash fasteners of required dia and size, including necessaryfillingupthegapsat junctions,i.e.attop,bottomandsides withrequiredEPDMrubber/neoprene gasket etc. Aluminium sections shall be smooth,rustfree,straight,mitredand jointedmechanicallywhereverrequired includingcleatangle,Aluminiumsnap beading for glazing / paneling, C.P. brass /stainless steel screws, all complete as per architectural drawings and the directions of Engineer in-charge.(Glazing and panelingto be paid for separately) :
31Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work forshutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixingoffittings whereverrequired includingthecostofEPDMrubber/ neoprene gasket required (Fittings shall be paid for separately)
32Providingandfixing12mmthick prelaminated particle board flat pressed three layer or graded wood particle board conforming toIS:12823 Grade l Type ll, in panelling fixedinaluminum doors, windowsshuttersandpartitionframes with C.P. brass / stainless steel screws etc.completeasperarchitectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides
33Providing and fixing glazing in aluminiumdoor,window,ventilator shuttersandpartitionsetc.withEPDM rubber / neoprene gasket etc. complete asperthearchitecturaldrawingsand the directions of Engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem):Withfloatglasspanesof 4.0 mm thickness (weight not less than 10 kg/ sqm)
34Providing and fixing glazing in aluminiumdoor,window,ventilator shuttersandpartitionsetc.withEPDM rubber / neoprene gasket etc. complete asperthearchitecturaldrawingsand the directions of Engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem):Withfloatglasspanesof 4.0 mm thickness (weight not less than 10 kg/ sqm)
35Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width.
36Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868withminimumanodiccoatingof grade AC 15) of approved design/pattern,withapprovedstandard section and fixed to the existing window framewithC.P.brass/stainlesssteel screws@200mmcentretocentre, including cutting the grill to proper opening size for fixing and operation of handlesandfixingapprovedanodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in charge. (Only weight of grill to be measured for payment).
37Providing and laying water proofing treatmentinsunkenportionofWCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :a) Firstlayer of slurry of cement @ 0.488 kg/sqmmixedwithwaterproofing [email protected]/sqm. This layer will be allowed to air cure for 4hours.b) [email protected] kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4hoursfollowedwithwatercuringfor 48 hours. The rate includes preparation ofsurface,treatmentand sealingofall joints,corners,junctionsofpipesand masonry with polymer mixed slurry.
38Solid block masonry using pre cast solid blocks(Factory made) of size 40x10x20cmornearestavailablesize confirming to IS 2185 Part I of 1979 for super structure above floor two level up tofloorV levelthickness 10cmand above in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
39Solid block masonry using pre cast solid blocks(Factory made) of size 30x22.5x15cm or nearest available size confirming to IS 2185 part I of 1979 for superstructureabovefloortwolevel uptofloorfivelevelthickness22.5cm andabovein:CM1:6(1cement:6 coarse sand sand) etc complete
40Cleaning of Floor area including removal of PoP/ Cleaning of existing door/window( of Second Floor ) and its disposal to dumping ground or as approved by Engineer-in-charge, for all leads including all lifts involved
41Demolishing of PCC threshold in floor overexisting expansion joint/Removal of existing Expansion Joint to cater for the execution of new expansion joint system and its disposal to dumping ground or asapproved by Engineer-in-charge,for all leads including all lifts
42Filling With Cinder in Sunken Slabs in:1:3Ratio (1cement:3 Cinder ) etc complete.
43a)Cleaning of surface using manual means & cleaning of all surface area by wire brush & water jet to remove all the loosely cement particles & undulation and with air blower in the groove area Note: expansion area work with mortar along with bonding worked with uniformly required where the joint of in proper groove area present over the surface ..(As per Engineer Incharge)
44b)After the surface preparation we can place a backer rod of 20mm in tight fit of the groove in between the expansion joint as per the site requirement.Expancell is a closed cell polyethylene foam supplied in circular cord lengths for use as a backup material for joint sealing applications. Expancell is available in a variety of sizes.Expancell polyethylene foam back-up cords have the ability to perform several functions. They enable the correct width to depth ratio of the sealing slot to be maintained and provide a firm backing for the sealant to be tooled. This will precipitate wetting of the sides of the joint during the sealant application thus facilitating good adhesion. The use of Expancell will also act as a bond breaker at the base of the joint thus preventing three sided adhesion and the accompanying additional stress during jointmovement. Expancell cords are normally installed by push fitting into clean, dry, dust free joints. If necessary a blunt tool can be used to assist in the insertion, however care must be exercised in avoiding damage to the skin of the Expancell. The diameter of the cord should be approximately 20% to 25% greater than the width of the joint, this will ensure that the cord is tightly held in position therefore greatly assisting in maintaining the required depth to width ratio..(As per Engineer Incharge).
45c) Sealant Filling (Nito Seal PU 40): After the backer rod is placed after er can brush the Primer -7 for bonding the concret and the polysulphide sealant fill the gap with Nito Seal PU 40 sealant. Nito Seal PU 40 is a two part joint sealant based on a liquid polysulphide polymer. Nito Seal PU 40 is available in two grades, gun grade for general applications and Pouring grade for joints in horizontal surfaces. Nito Seal PU 40 is particularly recommended for use in high rise buildings and other applications where access for subsequent maintenance will be difficult and the risk of early movement failure must be minimized..(As per Engineer Incharge)
46Substrate onto which the Expoband One is to be laid must be sound and dust free. New concrete must be fully cured and free from curing compound. The concrete surface ideally should be wood float finished for the width of Expoband One and free from irregularities, with well deigned arises and no vertical misalignment between each side of the joint. Prepare a suitable width of substrate slightly wider than the membrane width selected. Sharp arises should be ground down pencil round. Remove all dirt, dust and laitance by rigorous wire brushing or depending on site conditions. Any spalling or honeycombing must be repaired prior to the application of the Expoband One system. Should the substrate be wet, dry gently with a gas torch or hot air blower. Dampness should not reappear within 15 minutes for the substrate to be considered as being dry enough for the application of the Nito seal PU 40. A minimum 35 mm width of masking tape applied adjacent to either areas will provide an increased unbonded width and greater movement potential if required.(As per Engineer Incharge).
47Providingandfixingaluminiumsliding door bolts, ISI marked anodised (anodic coatingnotlessthangradeAC10as perIS:1868),Size of 250 X16 mm transparentordyedto required colour or shade, with nuts and screws etc. complete :
48Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays Size of 255 x 19 mm approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete.
49Providing and fixing window side push locks for aluminium sliding Window shutters with necessary screws etc. complete :
50Providingandfixing18mmthickgang sawcut,mirrorpolished,premoulded andprepolished,machinecutfor kitchenplatforms,vanitycounters, window sills, facias and similar locations of required size, approved shade,colourandtexturelaidover20 mmthickbasecementmortar1:4(1 cement:4coarsesand),jointstreated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing toedgestogivehighglossfinishetc. completeatalllevels.Graniteofany colourandshade.Area of slab upto 0.50 sqm
51Aluminum Handless for ventilators 100MM As per direction of engineering incharge
52PLUMBING WORKS Heading
53Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/ make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
54Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
55Bottle trap 38/40 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
56Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
57Providing and fixing toilet paper holder :C.P. Brass
58Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm Vide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms
59Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 20 mm nominal outer dia .Pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Make: Supreme, Finolex, Astral Concealed work including cutting chases and making good the walls etc.
60Providing and fixing UPVC connection pipe with brass unions Size of 45 cm length 15 mm nominal bore.
61Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore.
62Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore.
63Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. 15 mm nominal bore
64Providing and fixing SS gratingwith rim including setting in floor with white cement mortar and making good the floor. 125mm dia.
65Providing and fixing of overhead shower 120mm dia single flow (ABS body Chrome plated with gray pace plate) with shower arm 190mmand flange including all fittings etc. completeconforming to I.S Specification of approved make as per directions including all lead and lift etc., complete.
66Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements. Weighing not less than 106 gms.
67Supplying and fixing CP Health Faucet superior quality including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
68Providing and fixing PVC pipes, fittingsincluding fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in- Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
69Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in- Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2.
70Providing and fixing PVC floor trap self cleansing design with or without vent arm complete including cutting and making good the walls and floors.110mm dia inlet 110mm dia outlet
71Providing and fixing 15 mm nominal dia CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
72Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.2way Bib Cock
73Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in- Charge. Concealed work, including cutting chases and making good the wall etc.
74160mm Dia PVC Pipe
7540mm Dia PVC Pipe
76Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 25 mm nominal outer dia Pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Make: Supreme, Finolex, Astral Concealed work including cutting chases and making good the walls etc.
77Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 50 mm nominal outer dia Pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
78ELECTRICAL WORKS Heading
79Wiring forlight point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessedmedium class PVC conduit with modular switch, modular plate, suitable GI / PVC box and earthing the point with 1.5 sqmm,FRLS PVC insulated copper conductor single core cable etc. as required.
80Wiring for twin control light point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI / PVC box and earthing the point with 1.5 Sq mm FRLS PVC insulated coppper conductor single core cable etc as required
81Wiring for circuit / submain wiring along with earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required.
822 x 1.5 sq.mm + 1x1.5 sq.mm earth wire
832 x 2.5 sq.mm + 1x 2.5 sq.mm earth wire
842 x 4 sq.mm +1x 4 sq.mm earth wire
852 X 6 sqmm + 1 x 6 sqmm earth wire
86Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
873 core x 1.5 sq.mm
883 core x 2.5 sq.mm
89Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
9020 mm
9125 mm
9232 mm
93Supplying and fixing metal box of following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required.
94200mm x 150mm x 100 deep
95250mm x 300mm x 100 deep
96Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
97Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
98Supply and fixing 1 or 2 module, GI / PVC box alongwith modular base & cover plate for modular switches in recess etc as required
99Supplying and fixing suitable size GI / PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
100Supplying and fixing suitable size GI / PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
101Supply and fixing 3 pin, 6A ceiling rose on the existing junction box / wooden block including connection etc as required.
102Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto30 cm.) with 1.5sq.mmFRLS PVC insulated, copper conductor, single core cable etc. as required.
103Installation of exhaust fan upto 450mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
104Wiring for group controlled (looped) light point / fan point / exhaust fan point / call bell point (without independent switch etc) with 1.5 sqmm FRLS PVC insultated copper conductor single core cable in surface / recessed PVC conduit, and earthing the point with 1.5 sqmm FRLS PVC insultated copper conductor single core cable etc as required.
105Supplying & fixing suitable size GI / PVC box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections etc. as required.
106MCCB,MCB & DB\"s Heading
107Supplying and fixing following way horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnection, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
1084 way Double Door
1096 way Double Door
110Supplying and fixing 4 way Double door surface / recess mounted verticaltype, 415 volt, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200amps tinned copper busbar, common neutral link, earth bar, din bar, for mounting MCB\"s, (but without MCB\"s and incomer), as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required).
111Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
112Single pole
113Double pole
114Triple pole
115Triple pole and neutral
116Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
117Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
11840 amps
11963 amps
120Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
12140 amps
12263 amps
123CABLE TRAY Heading
124Supply & installing following size of perforated Hot dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforations not more than 17.5%, including bends, tees, cross member, reducer etc in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including GI bolts & nuts etc as required.
125150 mm width x 50 mm depth x 1.6 mm thickness
126300 mm width x 50 mm depth x 1.6 mm thickness
127EARTHING Heading
128Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
129Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing
130MV CABLE LAYING Heading
131Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
132Upto 35 sq. mm (clamped with 1mm thick saddle)
133Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
134Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
135Upto 35 sq. mm (clamped with 1mm thick saddle)
136Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
137MV CABLE JOINTING & END TERMINATION Heading
138Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
1393.5C x 95 sq.mm
1403.5C x 35 sq.mm
1414C x25 sq.mm
1424C x 16 sqmm
1434C x 10 Sq.mm
144Supply, Installation Testing and commissioning ofdouble conversion, DSP Based, True on line UPS systemwith 415V +/- 15%, 50Hz, 3Ph Input & 415V, 3Ph, 50 Hz , Output, working on 16 Bit microprocessor Architecture, RS 232 ports, monitoring software , Isolation Transformer, O/L.S.C. protections & self diagnostic features, LCD Display Panel for Functions & all parameters, complying with IEC standards. Convertors, Invertors & Battery Charger shallutilize PWM technology with IGBT for both rectifier & inverter. Battery Back up time of 30 minutes on full load capacity with required No of SMF Battery (VRLA type) with Battery managementSystem, housed insuitable Cabinet / stand, Static ByPass, complete withInternal wiring, interconnection cabling & all accessories to be provided. The System shall have in-built P.F.correction (output PF > 0.9) & shall ensure THD as per latest International standards.The efficiency of UPS shall be 95% or more. The UPS shall be suitable for medical application.
145The item shall also include supply, laying & termination ofrequired runs (3P+2N+2E) ofsuitable size copper cable from the circuit breaker in the UPS room to the UPS and from the UPS to the UPS panel in the same room.
14610 KVA with Individual Battery Bank
147Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.
1483.5C x 95 sq.mm
1493.5C x 35 sq.mm
1504C x25 sq.mm
1514C x 16 sqmm
1524C x 10 Sq.mm
153LIGHTFITTINGS & FANS
154Supply & installation of surface or wall mounted LED batten with polycarbonate housing & integrated electronic driver, high translucent diffuser,20 - 24 W LED light fixture (4 feet), p.f = 0.9, THD < 20%, 2kV surge protection, CCT= 5700K, Efficacy = 100 Lm/W, CRI = 70 etc with all required accessories. (Wipro LL20-221-XXX-65NE3 / Crompton LDL 20-WW/Havells LUMILINE BS20W LED865S PCWH).
155Supply & installation of surface mounted downlight fixture, die cast aluminium housing, high translucent diffuser,15 - 18W LED light fixture, p.f = 0.9, THD < 20%, 2kV surge protection, CCT= 5700K, Efficacy = 100 Lm/W, CRI = 70 etc with all required accessories.(Havells INTEGRA NEO SURFACE DLS15WLED857S /Crompton LCDSPLN-R-18-CDL/ Wipro Iris slim LD80-131-XXX-60-SM).
156Supply & installation of surface mounted downlight, die cast aluminium housing, high translucent diffuser, 5 - 10 W LED round light fixture, 2kV surge protection, CCT = 5700K, Efficacy = 100 Lm/W, CRI = 70 etc with all required accessories. (Crompton LCDSPLN-R-06-CDL / Wipro LD80-350-XXX-60-SM / Havells INTEGRA NEO SURFACE DLS10WLED857S
157Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(Havells efficiencia neo,Crompton energion/Bajaj efficio). The rate shall include suitable size anchor fastner and hook to mount the ceiling fan in the existing RCC slab.
158Supply & installation of 250 mm sweep, 1250-1280 rpm, rust proof body & blade, made with light weight PP material, automatic shutter, exhaust fan complete with all required accessories including mounting accessories. (Crompton Brisk air Neo/Havells Ventilair DX/Bajaj Dxl ).
159MISCELLANEOUS Head
160Collecting Electrical panel board from AIIMS authorities stored in the existing hospital building,loading,unloading,installation, testing and commissioning of the same in 3rd floor electrical room located at F block to be used for catering light and power services in the floor. All works to be done as per the directions of Engineer in charge
161Supply and fixing extra down rod of GI pipe, 15 mm dia, heavy gauge including painting etc as required.
162Supply and providing 2 mm thick & 1 m wideelectrical grade insulating mat to withstand 3.3 KV dielectric strength conforming to IS 15652/ 2006.
163Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.
164Supply and providing Electrical Main Single line Diagram (A1 size - colour print) duly framed, laminated and placed in a conspicuous location in the Electrical substation for clear vision.

AI Tender Summary

OUR REF NO 35334242
AUTHORITY Government Departments
TENDER VALUE 1.19 Crore
LAST DATE 12-01-2023
Authority
Authority Name All India Institute Of Medical Sciences
Work Description Renovation Works At 3Rd Floor Block-A In The Existing Hospital Bulding At Aiims Bibinagar, Telangana
Basic Detail
Tender No AIIMS/BBN/SE/03/2022-23
Bidding Type Tender
Location
City bibinagar
State Telangana
Key Dates
Publish Date 10 Jan 2023
Submission Date 12 Jan 2023
Open Date 12 Jan 2023
Finance
Tender Value 1.19 Crore
Tender Fee Ref. Documents
EMD 2.39 Lakhs
Exemption Not Available
Document List
56264d0e-9880-4d49-80cf-c9526fc26624.html
BOQ_767616.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 10, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 02, 2023
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 05, 2023
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 05, 2023
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 10, 2023
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 12, 2023
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 12, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 12, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

56264d0e-9880-4d49-80cf-c9526fc26624.html

xls

BOQ_767616.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders