Tender For Repair Maintenance Of External Water Supply Replacing Of Old Us Gi Tubing Gate Valves And Periodical Maint And Servicing Of Ro Plant Acs Street Lights And Repair Replacement Of External Electric Supply Including Lt Panel Maint Of Dg Sets At Af , gurgaon-Haryana

Military Engineer Services-MES has published Tender For Repair Maintenance Of External Water Supply Replacing Of Old Us Gi Tubing Gate Valves And Periodical Maint And Servicing Of Ro Plant Acs Street Lights And Repair Replacement Of External Electric Supply Including Lt Panel Maint Of Dg Sets At Af . Submission Date for this Tender is 13-01-2023. Diesel Generators Tenders in gurgaon Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

35318273
Corrigendum : Tender For Repair Maintenance Of External Water Supply Replacing Of Old Us Gi Tubing Gate Valves And Periodical Maint And Servicing Of Ro Plant Acs Street Lights And Repair Replacement Of External Electric Supply Including Lt Panel Maint Of Dg Sets At Af
Open Tender
Indian
Haryana
gurgaon
13-01-2023

Tender Details

Tender For Repair Maintenance Of External Water Supply Replacing Of Old Us Gi Tubing Gate Valves And Periodical Maint And Servicing Of Ro Plant Acs Street Lights And Repair Replacement Of External Electric Supply Including Lt Panel Maint Of Dg Sets At Af S

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Dec-2022 Amendment BOQ 06-01-2023
2 23-Dec-2022 Amendment BOQ 06-01-2023
3 06-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 99000.0 /-
Tender Value
INR 49.50 Lakhs /-

BOQ Items

Name of Work : REPAIR MAINT OF EXTERNAL WATER SUPPLY REPLACING OF OLD US GI TUBING GATE VALVES AND PERIODICAL MAINT AND SERVICING OF RO PLANT ACs STREET LIGHTS AND REPAIR REPLACEMENT OF EXTERNAL ELECTRIC SUPPLY INCLUDING LT PANEL MAINT OF DG SETs AT AF STATION DHANSAAND REPAIR REPLACEMENT TO JOINERY OF WOODEN MILD STEEL AND ALUMINIUM FLOORING PLUMBING SANITARY FITMENTS TILLING WORKPERIODICAL SERVICES AND CERTAIN INTERNAL BR WORKS AND EM WORKS ETC AT AF STN DHANSA UNDER AGE BR AF RAJOKRI AND AGE EM AF RAJOKRI OF GE AF GURGAON
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5m wide and not exceeding 1.50m deep for laying of water pipe lines/taking out pipe lines and getting out in Hard/Dense soil including forming bottom surface to required level and slope all as specified and directed.
2Returing ,fiiling including spreading ,leveling ,watering and well ramming in layers not exe. 25 cm thick soil all as specified and directed.
3Removal of surplus soil to a distance not exceeding 50 m and doepositing where directed at a level not exceeding 1.5 m above the strarting point.
4M&L 3- LAYER PP-R(Polypropelene random copolymer ) pipes SDR-11,PN 10Unservicable stabilised and antimicrobial welded having thermal stability for hot & cold water supply including all PP- R Plain & brass threadedpolypropelene random fitting fixed complete to walls , ceiling or in trenchesof size 50mm all as specified & directed
5Supply laying, testingGI tubing25 mm bore medium grade conforming to IS : 1239with all fittings laid in trenchescomplete all as specified and directed.
6Supply laying, testingGI tubing20 mmbore medium grade conforming to IS : 1239with all fittings laid in trenchescomplete all as specified and directed.
7Taking up cast iron water mains 100/150mm bore (including all fitting ),with spigot and socket ends/flanged ends /rubber gasket joint including disconnecting complete all as specified and as directed
8Supplying and laying ,testing Cast iron pipe100mm bore with spigot and socketed end ,class LA ,in any length laid in trenches /on pedestals complete all as specified and as directed.
9Supply,layingand jointing cast iron bends (any type ,radius and angle )tapers any type ,(straight ,bend,increasing ,decreasing or double socket etc) Tee pieces single branch ,cross (all sockets or socket and spigot /all flanged or one end flanged and other end spigot ,socketed )collars ,caps and plugs conforming to IS upto 150mm bore complete all as specified and as directed
10Drilling and tapping cast iron water mains for branch connection of the internal dia 20mm including clamp piece and nuts and bolts and directed.
11M&L forrun lead joints for following sizes of CI spun pipes /fittings complete all as specified and directed.
12100mm bore
13150mm bore
14Taking down of existing GI tubing 40/50/80mm bore any type.
15Taking down of exixting GI tubing 25mm bore
16Taking down of exixting GI tubing 20mm
17Taking outsluice valve /NRV of size 100mm/150 mm bore from existing distribution CI /DI mains all as specified and as directed.
18Lifting of submersible pump set any description from borewell including column pipe and submersible cable and lowering ofpump in bore well after development of borewellincluding replacement of coloumn pipes all as directedNote: cost of disconnecting pipe from header / cables from panel shall be deemed to be included in the quoted rate.
19M&L for repairs & Servicing ofdefective submersible pump of capacity up to10 HP by dismantling the pump & removing unserviceable parts , assemble the pump properly after replacementsof unserviceable partscomplete all as specified and as directed .Note:- (a) The rate is inclusive of transporting the pump from bore well siteto repair work shop & back to site. (b) The rate is inclusive ofturning / finishing work for fixing of parts properly.
20M&L for rewinding of Submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wire. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 03 Meter, Capacity of motor 10 HP complete all as specified and as directed .
21Supply and fix parts of submersible pump set of capacity 10 HP complete fo the following all as specified and as directed.
22Bearing bush Gun Metal
23Bearing bush SS with rubber
24Oil seal
25Thrust plate/thrust bearing set
26Sand Guard
27CI Thrust Casing
28CI stage casing
29GM Bush
30Mild steel key for impeller
31SS Studs with nuts
32CI Intermediate section
33SS coupling bush common for pump & motor with key
34High Tensile steel shaft
35Supply ,fixing ,testingand commissionng double flanged non-rising stem type cast iron sluice valve suitable for 100 mm dia bore pipe with hand wheel and suitable for pressure rating of PN :1.6duly drilled holes for fixing of nuts and bolts ,stem made of high tensile brass ISI marked and conforming to IS including rubber gasket ,nuts,bolts and washer complete all as specified and directed.
36Supply ,fixing ,testing and commissionng double flanged non-rising stem type cast iron sluice valve suitable for 150 mm dia bore pipe with hand wheel and suitable for pressure rating of PN :1.6duly drilled holes for fixing of nuts and bolts ,stem made of high tensile brass ISI marked and conforming to IS including rubber gasket ,nuts,bolts and washer complete all as specified and directed.
37Taking the water sample from semi under ground sump and submitted the sample of water to the Govt Approved lab for testing of water ,Chlorine test and chemical components test all as specified and as directed
38M&Lin replacement of flat submersible 3 core 6 sqmm cable PVC insulated unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed.
39M& L for servicing ofROof capacity15 to40 Rtrs per hour incl repair/replacement of following items:-
40Carbon filter
41Sediment filter
42Membrane
43R O Pump
44M& L for servicing ofROcapacity50 to 120ltrs per hour incl repair/replacement of following items:-
45Carbon filter
46Sediment filter
47Membrane
48R O Pump
49Servicing ofvertical pumpmotor set cap upto 7.5 HP ,oiling greasing and replacement ofMechanical seal suitable for the pumpset and of the same make as of existing
50Servicing ofvertical pumpmotor set cap 10 HP ,oiling greasing and replacement of Mechanical seal suitable for the pumpset and of the same make as of existing.
51Supply and fixin replacingof dosing pumpincl. Replacing of PVC pipe of existing size and make
52M& Lfor taking out pump motor set vertical cap 10HP in RO plant ,,dismantling pump and motor separately , rewinding of electric motor with super enamelled copper wire of existing gauge after cleaning the slotsproperly and assemblingand refixing in position and testing complete as directed.
5330 Cleaning of RCC underground sumpof Size10X10X10CFTcomplete by removing all scales, dirts, mud, chemical deposit etc from innerand outerchamber of tank as well as from the mouth of all circulating pipes connected with sump including scrapping out and throughly cleaning of internal surface/floor by using bleaching powder, soda ash etc complete all as dircted and specified.
54Dismantling/Braking old unserciceable /dilapidated valve pit and Construction ofnew brick masionary valve pit of size1.2 X1.20 X 0.9 mtr with brick work 15 mm thick internal and external plaster in cm 1:4 inlcluding 25 X 25 X 5 mm MSangle iron frame all around the fixed point by means of 04 Nos hold fast 150 mm long made out of flat iron, 25 X 6 mm embedded in PCC block 1 : 2 : 4 type B1 including hinges welded with angle iron frame and MS cover 3 mm thick , MS handle of suitable locking arrangements and applying two coat of synthetic enamal paint over a coat of red oxide primer including necessary excavation, removing/returning filling in soft/loose soil all as specified and directed
55S&F in repair Non return valve cast iron of dia 100mm bore all as specified and as directed .
56Servicing of R O PLANT WITH following work:- Overhauling , cleaning & servicing of filtrationplant and iron removal plant by taking out all the filter media,cleaning,welding worn out MS pipe/Plate and internal threading where ever required the inside cell of filtration plant throughly by removing all scales /dirts/muds /chemical deposits etc & after drying the cell inside, apply painting in the complete inside cell with 2 coats of black bituminous paint(Suitable for drinking water), after painting, reset the seviceable and washed filter media and replace the unserviceable filter media with new media under relevant item here-in-after)after completionof work, painting to outer surface including foundation, sluice valve, pipe etc with two coat of synthetic enamel paint with duly rubbing./cleaning of surfaces and writing the following:-
57Cleaning of RCCunder ground sumpof 50000 Gallon capacity complete by removing all scales, dirts, mud, chemical deposit etc from insidethetank as well as from the mouth of all circulating pipes connected with RCC tank including scrapping out and throughly cleaning of internal surface/floor by using bleaching powder, soda ash etc complete all as dircted &specified . Note Proper care should be taken during cleaning so that no scales/dirts/deposits enters the supply/delivery line
58Cleaning of RCC over head reservoir of 50000 Gallon capacity complete by removing all scales, dirts, mud, chemical deposit etc from inner& outerchamber of tank as well as from the mouth of all circulating pipes connected with RCC tank including scrapping out and throughly cleaning of internal surface/floor by using bleaching powder, soda ash etc complete all as dircted of specified. Note Proper care should be taken during cleaning so that no scales/dirts/deposits enters the supply/delivery line
59S & F25 liters storage water heater (Geyser)
60S&F Plug Top 15 amp
61M&L for defect rectification LTcable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. including and additional excavation in normal alluvial strata required for exposing the cable fault, removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of any size. The fault locating equipments will be brought to site within the time limit as instructed by Engr-in-Charge.
62Supply andjointing straight through joint suitable for LT 415 Volt XLPE cable of size 70 to 120 Sq mm 3.5 corecomplete all as specified and as directed by Engineer-in-Charge.
63Supply andjointing straight through joint suitable for LT 415 Volt XLPE cable of size 25 to 50 Sq mm 3.5/4corecomplete all as specified and as directed by Engineer-in-Charge.
64Supply, laying and testing in replacement of cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 25 sqmm x 4 corecomplete all as specified and as directed. Note : Provision of suitable double crimpped lugs and glands deemed to be included in quoted rates.
65Supply, laying and testing in replacementcable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 95 sqmm x 3.5 corecomplete all as specified and as directed. Note : Provision of suitable double crimpped lugs and glands deemed to be included in quoted rates.
66Supply, laying and testing in replacementcable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 50 sqmm x 3.5 corecomplete all as specified and as directed. Note : Provision of suitable double crimpped lugs and glands deemed to be included in quoted rates.
67Supply and fixed in replacement of MCCB 250 Amp, 4 pole, microprocessor based, breaking capacity 36 KA including under voltage/ over voltage relay all as specified and directed.
68Supply and fixed in replacement of MCCB200 Amp, 3 pole, microprocessor based,breaking capacity 36 KA including under voltage/over voltage relay all as specified and directed.
69Supply and fixed in repair/replacement of MCCB160 Amp, 3 pole, microprocessor based, breaking capacity 36 KA including under voltage/over voltage relay all as specified and directed.
70S & Fin replacement ofAluminium Cable lugs/Thimbles upto size 16 to 25 sqmm complete all as specified.
71S & Fin replacement ofAluminium Cable lugs/Thimbles of size 35 to 50 sqmm complete all as specified.
72S & Fin replacement ofAluminium Cable lugs/Thimbles of size 70 to 120 sqmm complete all as specified.
73Disconnecting and taking down existing bus bars 4 wire system from LT panel board cleaning with CTC applying with becktol solution, removing old insulation and providing new heat shrink insulating sleeves, connecting and fixing in the same panel with new nuts, bolts, washers of suitable size complete all as specified and directed.
74Disconnecting and taking out old existing worn out control wiring connections incl cable lugs of LT panel board of 4 wire system and supply and connect with new cable PVC insulated, stranded copper conductor 2.5 sqmm incl new copper lugs and nuts, bolts, washers complete all as specified and directed.
75Disconnecting and taking out old existing worn out cablelugs, nuts, bolts, washers etc fromLT panel board of 4 wire system (incomming and outgoing) and supply and connect with new aluminium lugs and nuts, bolts, washers etc complete all as specified and directed.
76Taking out old existing worn out neoprene gasket from shutters ofLT panel board single door /double doors or openable on both sides and supply and fix newneoprene gasket complete all as specified and directed.
77M&L for Boring of holes under road, pavement,hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 100 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.
78M&L for sub class ‘B’ bricks old sizelaid flat dry in trenches over cable, across the direction of cable complete all as specified & directedby the Engr in Charge.
79M&L for Foundation for Tubular swaged pole typePoleincluding excavation , getting out, pole foundation with PCC type D2 1:4:8 (with 40 mm graded aggregate). Coping of pole with PCC type C1 1:3:6 ( with 20 mm graded agregate)and removing surplus soil to a distance n.exc 50 m and making good surface all as specified and directed.
80Taking down of worn out PVC insulated copper cable 1.5 sqmm from street light fitting to junction box including conduit pipe complete all as specified and as directed.
81M&L for wiring with two run single core PVC insulated, stranded unsheathed copper cable conductor size 1.5 Sqmm and drawing through and including S&F steel rigid conduit not less than 20mm dia andfixed on pole including 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable connected to earth including connecting to earth duly complete all as specified and as directed.
82Supply and fixing in repacement of weather proof street light junction box of size 300 x 200 x 105mmincluding MCB SP 6 Amps 10KA"C" series and connecting terminals 4 way and fixing with street light poles using necessary MS clamps, nuts, bolts washers, lugs for incoming and out going cables, gland for cable etc of suitable size complete all as specified and as directed. Note : The rates quoted are inclusive of provision and fixing of suitable lugs and glands for cable connection.
83Supply and fix in replacement ofautomatic timer switch pole mounted enclosure consisting of ON/OFF switch based on LUX level power contactor 40 Amps, 10KA "C" series 4 pole, MCB 40 Amps, TP - 03 Nos, enclosure made of rust proof, shock proof, conforming to IP -54 complete all as specified and as directed. Note: (i)Inlet/outlet connecting cable PVC insulated aluminium stranded conductor 6 Sqmm, 4 single core for incoming & outgoing up to 8 Mtr deemed to be included in the unit rate. (ii) Provn of glands and lugs shall be deemed to be included in the quoted rate.
84M & L for replacement of chemicalEarthing Protection System With Copper Plate (92% Pure) Of Size 900mm x 600mm x 5 mm. Thick Buried Directly In Ground Connected To The Main Earth Lead Copper Strip 50mm x 6mm By Means Of 2 Set Accessories, Connected to Test Point Including Excavation in Rocky Type Of Soil, Providing Highly Treated Vegetable Soil, Earth Enhanced Compound Powder (ITPC EECP-15) Consists Of Copper Sulphate, Magnesium Sulphate, Graphite, Bentonite, Aluminium Silicate, Zinc Oxide & Iron Ore Alternate 15cm Layer Upto 15 Cm Above Top Edge Of Earth Plate, Construction Of PCC 1:2:4 Pit RCC Cover And Including Testing On Completion Complete In All Respect. (Note (i)Earth Lead Are Included Upto Test Point.(ii)Copper strip for interconnection for plate and taking out 2 Nos of copper strip of size 20 x 3mm from earth pit to test pointfor a distance not less than 7.5 Mtr.(iii) this chemical earthing to be connected with existing chemical earthing to make a grid and cost is to be included in quoted rate.
85M & L forreplacement of Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised iron strip 32×6mm as earthing lead by means ofbolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire meshand 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified.
86Supply and Fixing LED street light luminaire IP-66 grade of protection, power LED of 70/72 watt rating including driver and to ensure uniform distributioncomplete all as specified and as directed .Note :-cost of G.I. pipe bracket,bracket mounting clamp, bolts and nuts, line connector,if required shall be included in quoted rate.
87Taking down and dismantling HPSV/ LED type street light fitting for 45/ 70/150/250 watt capacity of any make/type from pole/GI pipe, unserviceable items to be kept in safe custody and taken as credit complete all as specified and directed.
88Supply and fillingsand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted.
89Supply & lay Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required Copper strip of size32mm x 6 mmall as specified and directed.
90Servicing of DG sets of capacity 25 KVA TO 320 KVAINCL . minor repair and replacement of the following items
91S & F in replacement of lubrication oil filter
92S & F in replacement of by pass filter
93Checking of hydraulic governer
94Checking and toping up of coolant
95S & F in replacement offuel filter.
96S & F in repair air cleaner element .
97Cleaning radiator complete set
98Topping up of Engine Oil as per manufacturer specification and any other checking as per manufacturer instructions.
99Supply and fixing in replacement of AVR S/F VARIABLE SPEED DCDGsuitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage 6 Amp 95 Volt DC suitable for DG set upto 320 KVA complete all as specified and directed.
100Supply & fixingfollowing items in replacement of DG Sets of various capacities :-
101Battery terminal, lug, bolts type suitable for heavy duty battery.
102Battery leads for copper conductor multiwired 16Sqmm. 1.5 mtrs long
103Hinges for DG set door of any size, any type as required on site.
104Dismantling/Taking out of radiator assembly to work shop for cleaning with compressed air ,pointing out leaking places and soldering carefully and refix in position after making it serviceableof DG sets of capacity 25 KVA TO 320 KVA.
105Dismantling of self starter, opening and segregating cleaning the serviceable parts for re-use, self starter servicing and greasing, re-assembling the self starter and replacement of following parts :- (i) Carbon bush(ii) Brass plunger(iii) Solenoid switch(iv)) Funnel coil(v) Body brass nut
106S&F V belt for fan pulley (set of 2Nos) for DG set upto 320 KVA DG Set complete all as specified and directed.
107S&F V belt for alternator and water pump assembly for DG set upto 320 KVA complete all as specified and directed.
108S&F Fuel hose pipe from fuel filter to fuel pump for DG set upto 320 KVA, complete all as specified.
109S&F Fuel pipe from fuel tank to fuel filter (transparent) for DG set upto 320 KVA, complete all as specified.
110S&F fuel feed pump suitable size as required on site for DG set of capacity upto 320 KVA, complete all as specified and directed.
111Supply and fixing of Fuse (HRC type) of required amps as per manufacture, for DG sets of capacity upto 320 KVAcomplete all as specified and directed.
112Supply and fixing in repair/replacement ofbattery 12 volts180 AH ,ISI mark for DG sets of capacity upto 320 KVA.
113Servicing, Oiling, Greasing and Cleaning of window type/ split type AC with high pressure pump of any capacity, checking of defects/ leaking and adjusting setting to work and testingand writing of MES no . complete all as specified & directed.byEngineer in charge .
114M & L for cutting of suction line and discharge line tubing of AC, front scaled unit de-scaling, flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 1.5 ton Split/W/T type AC
115Ditto but all as per item No -2 described here-in-before but 2 ton capacity split type AC/W/T type AC complete all as specifed & directed.
116Supply & Fix spare parts of Air Conditioner etc.:- Replacement of burnt out Stabilizer and S&F newStabilizer of 5 KVA voltage stabilizercomplete all as specified and as directed.
117M&L for replacement of running capacitor of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
118M&L for replacement of starting relay of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
119M&L for replacement of starting capacitor of existing make and capacity duly ISI marked for window type and split type AC 1/1.5/2 ton capacity complete all as specified and directed.
120S&F in replacement of Electronic control (PCB)of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
121Repairto compressor of size of existing makes and capacityfor W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
122S&F in replacement of Filter pad of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
123S&F in replacement of Thermostat switch of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
124S&F in replacement of remote for W/T and Split Type AC 1/1.5/2 ton complete all as specified and directed.
125Rewinding of blower motor ofW/T and Split Type AC 1/1.5/2 ton complete all as specified & directed.
126S&F in Repair/replacement of rotary type AC compressor of window type/splitAC , including gas charging of window type/splitAC of capacity 1.5/2Ton capacity complete all as specified & directed.
127S&F in Repair/replacement ofreciprocatingtype, AC compressor of window type/splitAC , including gas charging of window type/splitAC of capacity 1.5/2.0 Ton capacity complete all as specified & directed.
128S&F in replacement of Evaporator coil for W/T and Split Type AC 1/1.5/2 ton complete all as specified and directed.
129S&F in replacement of Suction/Discharge valve for W/T and Split Type AC 1/1.5/2 toncomplete all as specified and directed.
130S&F in replacement of Copper tube for 1.5 /2.0 Ton split AC, 1/4" complete all as specified and directed.
131S&F in replacement of Copper tube for 1.5 /2.00 Ton split AC, 1/2"" complete all as specified and directed.
132S&F in replacement of Copper tube cover complete all as specified and directed.
133S&F in replacement of insulation pipe size ¾” or 1” dia for split AC 1.5 / 2 Ton complete all as specified and directed.
134S& F in Repair /Replacement of outer unit incl compressor suitable for 1.5 tonsplit ACcomplete set of existing makea incl testing
135S& F in Repair /Replacement of inner unitsuitable for 1.5 tonsplit ACcomplete set of existing make incl testing .
136M& L for detection/ rectification of leakageof gas in the system and gas charging in the system with appropriate qty of gas incl uding testing for smooth functioning of water of capacity 40/60/80/120 ltrs complete all as specified and as direted . Note :-(i) cost of Unserviceablecondensing coil repaire if reqd deemed to be included in unit rate.(ii) Cost of dismantling of unserviceable compressor if reqddeemed to be included in unit rate . (iii) cost ofcompressor repair if reqd deemed to be included in unit rate.(iv) Refilling & topping up refrigent (type & quantity as required on site ) reqd deemed to be included in unit rate.
137S&F in compressor reciprocating type (hermitecally) sealed for capacity 40/60/80/120 Ltrs water cooler complete all as specified and as directed.
138S&F inrepair/replacementof thermostat switch suitable for existing water cooler of existing make and capacitycomplete all as specified and directed.
139M&L in replacement of Starting relay and overload relay suitable for existing size & make of water cooler completeall as specified and directed.
140M&L in replacement of Starting capacitor for water cooler suitable for existing size& make of water cooler completeall as specified and directed.
141M&L in replacement ofrunningcapacitor suitable forexisting size & make water cooler completeall as specified and directed.
142M&L in dismantling of old defective condenser , fan motor of water cooler of any make and capacity and refixing and testing the same after rewindingwith super enamelled copper wire as specified and directed.
143M&L in servcing of Deep freezer of any capacity and size by cleaning greasing including painting with one coat of super synthetic enameled paintincluding prepartion of surfaces completeall as specified and directed.
144M&L of Gas Charging in deep freezer of any makeand capacity including testingof leakage complete all asspecified and directed.
145Servicing of Airconditioning unit of 4.6 TR cap. ,cleaning with service chemical& air pressure the whole package unit inside,cooling coils ,indoor and outdoor units complete all as specified and as directed.
146Testing of pipe line for any type of leakageusing nitrogen gas at pressure of 20 kgs/ sqcm and 10Kgs /sqcm on low side and holding it for 24 hours and detecting the leakages and brazing the leakingpoints to stop leakages completely vall as specified and as directed.
147Making the refrigerant piping system clean through vacuum and supply and charging the refrigerant gas of required quantity and make as recommended by manufacturer to get required cooling.
148Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
149M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:6)for bedding of tilescomplete all as specified and directed.
150M&L for 10 mm thick rendering in cement mortar (1:4) on vertical surfaces for backing of tiles complete all as specified and directed.
151M&L for joint free Non- skid ceramic coloured tiles 7 to 8mm thick (Square/ rectangular) area of each tile exceeding 0.11 but n.exc 0.18 Sqm, in floors/shirtingetc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
152M&L for ColouredVitrifiedCeramic tiles 9-10 mm thick (Square/rectangular) oflight Shade , polished, area of each tilenot exceeding 0.36 sqm, fixed in floor/skirting etc overset and jointed in neatcement slurry and pointed in coloured cement to match with coloured tiles complete all as specified and directed.
153M&L joint free Glazed ceramic coloured/ printed tiles in vertical surface of size 350x 250 x 6-7mm/450x 300 x 6-7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match on walls as in dado/ skirting etc complete all as specified and directed.
154Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
155M&L for 25 mm thick PCC 1 :2 :4type B-0 (using 12.50 mm graded stone aggregate) as in flooring finished even and smooth without using extra cement complete all as specified and directed.
156M&L for 40mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in flooring finished even and smooth without using extra cement complete all as specified and directed.
157M&L for 75 mm thick cement concrete (1:4:8) type D-2 with using 40 mm graded stone aggregates) asin sub base of flooing etc complete all as specified and directed.
158M&L for screed bed or bedding layer of mortar 20 mm thick in cement mortar (1:6)for laying floor finishescomplete all as specified and directed.
159M&L for chequered cement concrete coloured tiles 30 cm x 30 cm x 25mm, set jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified and directed.
160M&L for cement concrete type B0 1:2:4 (using 12.50 mm graded stone aggregate) as in coping benching, gola, slightly rounded and similar items complete all as specified and directed.
161M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggreate), 75 mm thick as in plinth protection including finishing the surface even & smooth without using extra cement complete all as specified and directed.
162M&L for cement concrete type B-1 (1:2:4) with using 20mm graded stobe aggrgates) as insurface channels and drains
163Dismanting of stone slab and tiles laid bedded and pointed in any mortar of any size description or thickness in floor, appron etc.
164M&L for 18-20 mm thick Granite tiles machine cut , bedded and jointed with grey cements slurry and pointed with white or colour cement with admixture of pigment to match the shade of granite stone including grinding & polishing slab over screed bed or bedding layer of mortar 15 mm thick in cement mortar (1 : 4)laid complete all as specified and directed.
165M&L for 18-20 mm thick Granite tiles machine cut, in skirting/dado laid over cement mortar and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over 10 mm thick rendering in cement mortar (1:4) on vertical surfaces for backing of tiles complete all as specified and directed.
166M&L for preparation of plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing scrapping down smoke spot moulds moss and efflorescent salts and treating oily & greasy spots and filling of holes and cracks with with suitable material like cement or plaster of paris etc and thereafter applying one coat of oil bound distemper on walls complete all as specified and directed.
167All as per item No.132 here-in-before but on surfaces of ceiling.
168M&L for providing 3mm thick wall care putty on wall before applying oil bound distemper and making the surface uniform all as specified.
169M&L for preparation of old painted surfaces of wood & wood based of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified.
170M&L for preparation of old painted surfaces of steelof any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified.
171M&L preparation of old French polishing surfaces of any description , in width or girth and applying a coat of French polishing including wood filler , complete all as specified and as directed.
172Complete removal of existing treatment from external surfaces of walls, parapets, fins/ facia, chajjas by wire brushing and washing, rubbing down and stopping of surfaces and levelling/ edging the disturbed places/ edges using necessary filling compound ofcement based putty to obtain smooth regular/ even finish surface using sand paper and applying two coats of weather prrof exterior emulsion paint over a coat of primer in Camouflage Pattern complete all as specified.
173Demolition of brick or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone works and precast concrete articles, complete all as specified.
174M&L forbrick work with sub class ‘B’ bricks old size straight or curved on plan exc 6.0 m mean radius built in cement mortar 1:6 complete all as specified.
175M&L for brick work with sub class "B" brick, straight or curved on plan to any radiusin half brick works, built in CM 1:4 etc complete all as specified and directed.
176Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys ,scrubbing down with water etc complete all as specified.
177M&L for 15 mm thick plastering in two layers (10+5) mm in cement mortar (1:4) on brick or concrete surfaces including rendering on fins, fascias, chajja, parapets etc and finishing the surfaces even and fair (without using extra cement), top layer shall be with WPC as per manufacturer"s instruction and complete all as specified. Note: WPC shall be measured and paid separately.
178Supply only intergral water proofing compound ISI Marked complete all as specified.
179M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of cement primer on walls. complete all as specified.
180M&L for preparation of newly plastered surfaces of wall and applying two coats of weather proof exterior emulsion paint over a coat of primer complete all as specified and directed.
181M&L for rendering 15 mm thick in cement mortar (1:6) onbrick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified.
182M&L for preparation ofnewly plastered or unplastered/undecorated surface of wall and applying two coats of oil bound distemper over one coat of primer complete all as specified.
183M&L rendering 10mm thick in cement mortar1(1:3) as in ceilings finished even and smooth (without using extra cement) complete all as specified.
184M&L for preparation ofnewly plastered or unplastered/undecorated surface of Ceiling and applying two coats of oil bound distemper over one coat of primer complete all as specified
185Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified & directed.
186S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with selftapping screws as specified & directed.
187Dismantling mild steel work of any description not otherwise provided for complete all as specified and directed.
188S&F rolled mild steel in framed work as in doors or steel gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing conforming to Fe- 290.Gde-E-165 complete all as specified.
189S&F framed work such as grills gratings, etc with ends of bar shouldered and/or revited or forged into spikes, framed guard bars, barred iron doors, ladders, framedbalusters, walk ways, railings framework of water tanka and similar works confirming to Fe 290 Gde E-165 complete all as specified
190S & F Rolled Mild Steel Plates (plain or Chequered) channels, square cut or notched, forming holes, without any attachment confirming to Fe 410-S complete all as specified.
191S&F steel work as in tubular, rafters, purlins, posts and similar work(round/sqare/rectangular shape of pipes as approved by Engr-in-charge ) trusses of semi circle/ curved shape up to height 6 mtrincluding postspecial shaped washers etc complete incl necessary nut bolts wind ties and gusset plates etc using ERW or induction butt welded tubes conformining to IS 1161-1998 garde St-240
192M&L for preparation of new or previously untreated steel surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
193Dismantling ceiling board (fiber, pulp insulation) or insulation board/slabs etc including grid work/wooden or aluminium frame works, cover fillet etc Complete all as specified.
194M & L for clip in type armed strong metallic powder coated 0.5mm thick ceiling with GI framework made of standard Tee , Angle or any other section as in grid type ceiling framework as approved by GE . Ceiling shall be hanged to roof trusses / purlin rafters with the help of GI wire not less than 4mm dia at an interval n. exc 1m , the size of the metallic powder coated ceiling tiles 600 mm x 600 mm complete all as specified.
195Taking downchowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and directed.
196All as per item No 161 here-in-before butexc 1.5 Sqm and not exc 4 Sqm each complete all as specified and directed.
197Taking down chowkhats or frames not exc. 1.5 sq. m each complete all as specified and directed.
198All as per item No.163 here-in-before butexc 1.5 Sqm and not exc 4 Sqm each complete all as specified.
199Taking down shutter of any description exc 1 Sqmand n exc 2 Sqm and removing from site.
200Hacking out old broken glass (any thickness, size, quality or escription) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
201S&F factory made 35mm thickflush shutters , solid core construction with block board core and plywood face pannel commercial type on both faces complete all as specified.
202S&F factory made 35mm thick 2nd class hardwood glazed and skelton door shutters, open rebated and prepared to receive glass, gauze, (without sash bars) edges for framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part-1 section 8 clause 8.24 (a) fitted to chowkats complete all as specified.
203S&F solidPVC door frame of size 50mm X47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification and drawing.
204S&F factory made PVC shelter panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheetfor top rail, lock railand bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement , supplying and fixing in the frame at site as per specification & drawing as specified.
205S&F window or ventilators section of frame 72x55mm fixed to wall or concrete surface with rowl plugs made of galvanised steel powder coated and section of shutter 47x20mm mulion section 72x50mm (Based steel as per IS 513 "D" quality galanised as per IS 277 with zinc of 120 gms/sqm) glazed or gauged and wire gauge shutter prepare to receive wire mesh to the shutter (Double door shutter) with total coated thickness of 0.6mm including grills/guard bars made of square bars powder coated fixed to window frame with screws including necessary fittings and all builders hardware such as handles, tower bolts and stays etc complete all as specified and as directed.Make : NCL type-4000 Series (Note : Glass and wiremesh shall be measured and paid separately under respective items)
206S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified.
207S&F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified.
208M&L for preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
209S&F 100 mm Butt hinges, Stainless steel and fixed complete all as specified and as directed.
210S&F 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified.
211S&F 150 mm size extruded aluminium alloy handles fabricatedtype anodised and fixed.
212S&F sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads complete all as specified.
213S&F forPressed steel frames 125X60mm (made out of 1.25mm thick MS Sheet) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete as specified.
214S&F Pressed steel frames 105X60mm (made out of 1.25mm thick MS Sheet) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete as specified.
215M&L forprepration of new Steel surfaces of any description, not otherwise descri-bed, over 10cm width or girth & applying two coats of synthetic enamel paintcomplete all as specified
216Taking down of aluminium frame/doors/windows from site dismantling aluminium structure such as glass, rubber beading aluminium clips complete all as specified.
217S&F powder coated Anodised aluminium frame for partition, doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
218S&Fpowder coated anodized aluminum door shutters, aluminum section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing handles 2 Nos in each door,100 mm longhinges (3 Nos), anodized aluminum snap beading screws etc. complete all as specified.
219S & Fpowder coated Anodised aluminium window and ventilator shutters side hung type without sash bar, aluminium sections weighing 0.55 kg/m including necessary joining, cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as hinges type B-21 100 mm long - 2 Nos, suitable size handle -1 No & tower bolt 100 mm -1 No complete all as specified.
220M&L for 5.5 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n. exc 0.5 sq. m in each panecomplete all as specified.
221M&L for 5 mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each panecomplete all as specified.
222S&F 9 mm thick prelaminated both side particle board exterior grade in bottom panel of Aluminium door including rubber gasket, aluminium glazing clips complete all as specified.
223S&F fabricatedanodized aluminium grill of size 75x100mm, using 5 mm dia bars fixed to frames using U/V section runners complete all as specified.
224S&F in repair Mortice lock, vertical type of brass 100 mm 4 Levers with duplicate keys complete all as specified.
225S&F in repairs aluminium (Die cast) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified.
226Dismantling boarding of any description , fixed in any position with nails complete all as specified.
227M&L for PVC 18 mm thickdecorative lamination board of density 600kg/cbm manufactured by an ISO:9001-2005 certifed with termite proof, water proof & flame retardant PVC Sheet. complete fixed with each other using solvent cementadhesive and stainless steel screws & including required handle, panels shall be fabricated using adhesive and screws and all the edges shall be covered with bonding tape and finished as per manufacturer instruction and all as specified.
228M&L for Auto soft closed hinge for PVC laminated board complete all as specifed and as directed
229S&F in repair 25 mm outer dia medium weight pipe made out of stainless steel 304 grade, includingdecorative ornamental knobs at both ends and one set of ornamental decorative Stainless steel clamps tofixed towalls complete all as specified.
230S&F in repair white vitreous China wash down water closet pan (pedestal pattern), and trap(excluding fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc.complete all as specified.
231S&Fas in repair vitreous china squatting pan, white, orissa pattern, size 580x440mm with integral foot rests (excluding flushing cistern & flush pipe) with cast iron ‘P’ trap incl lime concrete bedding and making good to the disturbed surface to match with the existing surface of floor complete all as specified and as directed
232S&F in repair vitreous china wash hand basin (flat back) of size 550x400mmincluding one number chromium plated waste fittings, 32 mm dia, brass with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, with & including 32 mm dia PVC waste pipe with connector,including cutting for and pinning in ends of brackets completeall as specified.
233S&F in repair of plastic water closet sheet covers white closed pattern with flat bottom, with mild steel chromium plated or aluminised hinging device complete all as specified.
234S&F in repair fancy typeAngle stop cock with flange, 15 mm nominal bore, brass, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified.
235S&F in repair angular two way angle cock with wall flange, 15 mm nominal bore cast copper alloy, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified.
236S&F in repair pillar taps, cast copper alloy, with capstan heads, fancytype chromium plated, screwed down high pressure with or without lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for 15mm bore iron pipe and fixed complete all as specified.
237S&F in repair bib taps, long body,brass, fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule orto GI socket complete all as specified.
238S&F in repairs PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic actiontype with inlet ball valve and float, handle with & including bracket andPVC flush pipe 32 mm borecomplete all as specified.
239S&F in repair PVC connection 450 mm long suitable for 15 mm GI pipe with two brass nuts & rubber washers complete all as specified.
240S&F as in repairPVC looking mirrorof selected quality of size 600 mm x450 mm on 4 mm thickwith framefixedscrew and cup- washers complete all as specified.
241S&F in repairtubular towel rail 20mm dia type brass chrormium plated 600mm long between flanges complete all as specified and as directed
242S&F in repair chromium plated shower roses 125 mm size with or without swivel joints of standard size including fixing to 15mm steel pipe or union complete all as specified.
243S&Fin repair Corner glass shelf (with bracket) , fancy type with stainless steel railing fixed to wall with rawl plugs and chromium plated screws complete all as specified and directed.
244S&F in repair fancy type central hole basin mixer without PUW with 450 mm flexible hosecopper alloy with capstan heads CP screwed down high pressure with or without lettered Hot or cold with long screwed shanks and fly nuts screwed for iron pipe fixed complete all as specified.
245S&F in repair chromium plated health faucet telephonic type with 8mm dia, 1 meter longCP flexible with wall hook and jet of approved make, suitable for 15 mm bore iron pipes or for unions and fixed complete all as specified.
246S&F in repair soap dish, brass, chromium plated,, fancy type fixed to wall with rawl plugs and chromium plated screws complete all as specified.
247S&F in repair toilet paper holder ,brass,chromium plated,, fancy type fixed to wall with rawl plugs and chromium plated screws complete all as specified.
248S&F in repair 200 mm dia towel ring ,brass,chromium plated,, fancy type fixed to wall with rawl plugs and chromium plated screws complete all as specified.
249S&F in repair towel Rack 600 mm with hanger,brass,chromium plated,, fancy type fixed to wall with rawl plugs and chromium plated screws complete all as specified and directed.
250S&F in repair sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified.
251S & F in repairs 900 x 800 x 260 mm plate rank of stainless steel with steel shelves make out of 0.7 mm thick steel sheet and hanging arrangement for utensil including taking down existing completeallas specified and directed
252S&F in repair PVC (SWR) floor trap plain with gratinghaving dia meter of out let 75mm including jointing with solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified.
253S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 75mm bore.
254S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 110 mm bore.
255S&F in repair PVC (SWR) bends any radius 110mm bore.
256S&F in repair PVC (SWR) bends any radius 75mm bore.
257S&F in repair PVC (SWR) junction single, (single T) equal or unequal 75 mm bore complete all as specified.
258S&F in repair PVC (SWR) junction single, (single T) equal or unequal 110mm bore complete all as specified.
259S&F in repair 110mm dia PVC (SWR) pipe and single socketed in any length with rubber ring joint fixed to wall.
260Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 250 liters but not exceeding 500 litres complete all as specified.
261S&F for rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylinderical verticalwith closed top) hoisted and fixed in position all as per SSR Part I complete all as specified.
262Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 500 liters but not exceeding 1000 litres complete all as specified.
263S&F for rotational moulded polyethylene water storage tanks 1000 ltrs capacity (cylinderical verticalwith closed top) hoisted and fixed in position all as per SSR Part I complete all as specified.
264S&F in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm bore and fixed, minimum weight of float valve 210 gms complete all as specified.
265Taking up or down15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
266Taking up or down20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
267Cutting chases, pinning in. making good to facings where required andpointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girthin brick wall etc complete all as specified.
268Supplying and laying of CPVC pipes 16 mm outer diameter SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified
269Supplying and laying of CPVC pipes 20 mm outer diameter SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
270S&F in repair 20mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
271Dismentling and taking out old burnt darnaged coils of ceiling fan 1200/1400mm sweep including scraping out old paint & cleaning all dust making smooth surface with filler materials/sand paper & painting with 1st grade quality synthetic enamel paint by spray & proper numbering including replacing of Twin flexible wire with new from ceiling rose to connector of fan complete all as specified and as directed
272(a) Rewinding of ceiling fan 1200/1400 mm sweep with the same guage as per existing by new supper enameled copper wire including insulating material heating, varnishing, reassembling, testing completing to the entire satisfaction of Engr-in-Charge:- (c)S& F of following parts in replacement of unserviceable parts : - (i) Ball bearings ISI mark (ii) Conenser 2.50 mfd (iii) Split Pin (iv) Fan blades (v) Down rod
273Taking down old unserviceable sub main wiring any size/core/type of copper/aluminium conductor including making good the disturbed surfaces and removing materials from the site of work complete all as directed
274Supply and Fix submain wiring alongwith earth wire single core multi stranded copper conductor FRLS unsheathed PVC insulated 1100V grade cable drawn into and including PVC casing capping sleeves and caps of adequate width and length with accessoris and fittings like bend crosses wall crosses etc 2x6.0 sqmm 1 x 4.0sqmm wire Make of wire Havells/Plaza/Finolex. Make of PVC casing capping : Plaza/Horse/Pesto Plus
275Supplyand Fix submain wiring alongwith earth wire single core multi stranded copper conductor FRLS unsheathed PVC Insulated 1100V grade cable drawn into and including PVC casing capping sleeves and caps of adequate width and length with accessoris and fitting like bend, crosses wall crossing etc 2x 10.00 sqmm 1 x 6.00Sqmm wire Make of wire, Havells/Plaza/Finolex. Make of PVC casing capping : Plaza/Horse/Pesto plus
276Supply and Fix Sheet metal enclosures TPN-4 x 4 way , 200 Amps Bus Bar 240 Volts Double door
277M and L MCB TPN 440 volt, 32 to 63 Amps C series ,10 KA, Make Havells/Plaza/Legrand
278M and L MCB SP 240 volts, 5 to 32 Amps , C series 10 KA Make : Havells/Plaza/Legrand
279M and L MCB SPN 240 Volts, 5 to 32 Amps, C Series , 10 KA Make : Havells/Plaza Legrand
280Taking down from site or from store exhaust fan, Dismentling and taking out old burnt damaged coils of exhaust fan 300/450 mm size including scraping out old paint & Cleaning all dust making smooth surface with filler materials/ sand paper & Painting with 1st grade quality synthetic enamel paint by spray and proper numbering including replacing of Twin flexible wire with new from ceiling rose to connector of fan complete
281Rewinding of exhaust fan 300/450mm sweep with the same guage as per existing by new supper enameled copper wire including insulating materials heating varnishing reassembling testing complete to the entire satisfaction of Engr-in-Charge
282S and F of following parts in replacement of unserviceable parts
283Ball bearings ISI mark
284Condenser 4.0 mfd
285Split pin
286Fan blades
287M and L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts nuts check nuts and washer GI earth wire with protected by 15mm dia light grade GI pipe and other end connected to earth testing point or main controlling switch as directed including funnel with watering pipe 20mm bore light grade GI Pipe wire mess charcol and common salt concerete earth pit in PCC (1:3:6) type CI cast iron frame cover , including necessary excavation earth work in soft/loose soil and disposal of soil to a distance not exc 50mtr and necessary testing complete all as shown in electrical plate No 3 of MES schedule Pat I and testing all as directed
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail