Numaligarh Refinery Limited has published Tender For Assistance In Project Related Electrical Jobs In And Around Nrl Site. Submission Date for this Tender is 30-12-2022. Man Power Supply Tenders in numaligarh Assam. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 29-Dec-2022 | Corrigendum 1- Annexure-XIII to Instructions to Bidders and titled PROFORMA FOR BANK GUARANTEE FOR EARNEST MONEY DEPOSIT stands deleted | Other | 30-12-2022 |
Sl. No. | Item Description |
1 | Assistance in temporary construction power facility |
2 | Assistance in temporary construction power facilities in normal working hours inside Refinery and as per direction of E-i-C |
3 | Assistance in temporary construction power facilities in normal working hours inside Refinery during odd hours/offdays/holidays and as per direction of E-i-C |
4 | Composite Work for temporary construction power facility |
5 | Earth work in excavation for all kind of Soil including all labour, materials, dressing of sides, pumping & bailing out water acM3ulated due to rain and / or subsoil waters and including disposal or stacking, leveling and neatly dressing as decided byEngineer-in-Charge including providing temporary supports to existing service lines like water pipes, sewerage, electric cables, etc., if any, complete, all materials and labour complete and as directed by Engineer-in-Charge for following depth.Excavated soil shall be disposed at least up to the distance of 500 meterfrom the plant Boundary (Unit Area Boundary) for backfilling and the charges for the same is included in this item. |
6 | Excavation and backfilling of trenches etc in all types of soil (except rock), shoring, shuttering and dewatering (if necessary) including consolidation and disposal of surplus earth upto a distance of 100 metre including all labour and materials complete as per approved drawings, specifications and direction of Engineerin- charge.(Excavated trench dimentions shall be measured) |
7 | Supply and spreading of approved fine river sand in cable trenches including all labour and materials complete as per specifications and direction ofEngineer- in-charge. |
8 | Supply and laying of approved second class bricks of thickness 3" in cable trenches for cable protection including all labour and materials complete as per specifications and direction ofEngineer- in-charge.(Actual area of laid brick surfaces shall be measured) |
9 | Laying/removal of cables with outer diameter upto 40 mm. LAYING CABLE :Laying, testing and commissioning of following sizes LV, MV &HV Cables and sealed properly of upto /3.5/ 4of size PVC caps in designated cable route (in built-up readymade trenches; overhead cable trays; pull through pipes; exposed on wall/ beam/ rakes/ trusses tie/ beam/ embedded in floor or buried directly underground; or through G.I.pipe ). Cables shall be PVC/XLPE insulated; PVC Sheathed; FRLS armoured Aluminium/ Copper Cables or similar types as per IS:1554 (PART-I), IS 7098 PART I & IS 1225-latest version.;Unit rates quoted for installation of cables shall be same irrespective of route and method of laying. The item shall include laying, pulling of cables, proper dressing of cables on cable trays, racks, vertical raceways etc. and supply and installation of saddles, spacers and nylon chord for tying as required, stainless steel/aluminium/lead strip identification tags at strategic points/ every 50 meter intervals, aluminium clamps etc. The straight through Jointings/ tying of upto 1100V 3/3.5/ 4 core of size armour in the cables should be avoided/ minimised. Item includes transportation from store/yard to site at the place of installation, unpacking, including all labour and materials.Empty drums and excess cable to be rerolled and transported backto desigated store/yard. The designated store/yard will be located inside NRL refinery site or NRMT. |
10 | Laying/removal of cables with outer diameter above 40 mm. LAYING CABLE : Laying, testing and commissioning of following sizes LV, MV &HV Cables and sealed properly of upto /3.5/ 4of size PVC caps in designated cable route (in built-up readymade trenches; overhead cable trays; pull through pipes; exposed on wall/ beam/ rakes/ trusses tie/ beam/ embedded in floor or buried directly underground; or through G.I.pipe ). Cables shall be PVC/XLPE insulated; PVC Sheathed; FRLS armoured Aluminium/ Copper Cables or similar types as per IS:1554 (PART-I), IS 7098 PART I & IS 1225-latest version.;Unit rates quoted for installation of cables shall be same irrespective of route and method of laying. The item shall include laying, pulling of cables, proper dressing of cables on cable trays, racks, vertical raceways etc. and supply and installation of saddles, spacers and nylon chord for tying as required, stainless steel/aluminium/lead strip identification tags at strategic points/ every 50 meter intervals, aluminium clamps etc. The straight through Jointings/ tying of upto 1100V 3/3.5/ 4 core of size armour in the cables should be avoided/ minimised.Item includes transportation from store/yard to site at the place of installation, unpacking, including all labour and materials.Empty drums and excess cable to be rerolled and transported backto desigated store/yard. The designated store/yard will be located inside NRL refinery site or NRMT." |
11 | Supply,fabricationandinstallationofMSbaseframes, supportsforswitchgear,andbracketsformiscellaneous electricalequipments,cableandcabletraysupportsout of rolled MS sections, pipes, plates etc. including shot blasting, welding, bolting, rivetting,supplyofnecessaryanchorboltsandgrouting etc.,supplyofpaintandapplyingonecoatofanti-rust primerandtwofinishedcoatsofapprovedsynthetic enamel paint including breaking walls, floors etc. for structures as required includingsupplyofallGIhardwarematerials,alllabour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in- Charge.(Anyitemweighingupto1kg.orlessshall neither be measured nor paid). |
12 | Supply of class B, GI Pipes/sleeves 100NB |
13 | Fabrication and installation of of 100 mm dia, class B, GI pipes/ sleeves for cable protection, fixed on steel, concrete or similar structure, in trenches, ready to be buried in concrete including cutting, bending, grinding, threading and similar works, supply & fixing of required GI fastners, clamps, small iron structures, spacers, cleats, plug, bushings, sealing compound/ material etc., cutting and remaking of concrete surface including supply of civil material, all labour and materials complete as per approved drawings, specification of this tender and directions of Engineer-in-charge. |
14 | Supply of class B,GI pipes/sleeves 150 NB |
15 | Fabrication and installation of of 150 mm dia, class B, GI pipes/ sleeves for cable protection, fixed on steel, concrete or similar structure, in trenches, ready to be buried in concrete including cutting, bending, grinding, threading and similar works, supply & fixing of required GI fastners, clamps, small iron structures, spacers, cleats, plug, bushings, sealing compound/ material etc., cutting and remaking of concrete surface including supply of civil material, all labour and materials complete as per approved drawings, specification of this tender and directions of Engineer-in-charge. |
16 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (25 mm) |
17 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (32 mm) |
18 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (40 mm) |
19 | Supply and installation of universal DLP PVC Trunking(105 X 50 mm) with all fittings and accessoriesincluding cover, separation partition, angles, end caps, junctions, clips etc. complete as required as per direction of EIC. Make Legrand or equivalent |
20 | Grubbing, scrubbing & clearing the areas, removal of roots/boulders,breaking clods, making up the hollow produced by removal of roots/boulders with available earth, clearing the site of all objectionable/unserviceable materials,scraps and debris etc. by means of manual or mechanical excavation as per directions of Engineer-in-Charge. The cutting and stripping work shall be done to an average depth of 300 mm and the surface rough-levelled for subsequent works. Including loading, transport, unloading and disposal of the unserviceable material at designated areas within the plant boundary and leveling the same. |
21 | Removal / Dismantling of Various Voltage Grade Power Cables and Various sizes Power/Control Cables and associated cable terminations.This includes supply of consumables tools, suitable vehicles for transportation, loading / unloading facility. |
22 | Removal / Dismantling of Various Electrical Equipment / items (11KV HV Switchgears, 415V MV Panels, 415V Feeder Pillar Boxes, DG Sets, Lighting Panels, Earthing Materials, etc), shifting, storage at OWNER"s storage point within plant premises.This includes supply of consumables tools, suitable vehicles for transportation, loading / unloading facility. |
23 | Supply and laying of 1000 mm wide safety insulating Rubber Mat suitable for 11 kV System Voltage required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable latest Indian or International standards, CEA regulations and as per directions of Engineer-in-charge |
24 | Supply and laying of 1000 mm wide safety insulating Rubber Mat suitable for 415V System Voltage required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable latest Indian or International standards, CEA regulations and as per directions of Engineer-in-charge |
25 | Supply and installation of cable markers Supply and installation of cable markers for buried HV/MV cable at the interval of 30M, at every bend & at every cable joint location, supply of associated materials including engraving """"BURIED ELECTRIC CABLES HT/LT"""" complete with support and foundation,painting as per approved drawing, specification of this tender and directions of Engineer-in-charge. This includes supply & installation of all necessary consumables, GI hardwares." |
26 | Supply, Installation, connection of 40 mm dia & 3000 mm long GI ROD electrode. Supply, Installation, connection to main earth grid, testing and commissioning of earth pits in hard soil area complete with 40 mm dia & 3000 mm long GI ROD electrode, GI test link, concrete chamber with Cast Iron (CI) cover as inspection chamber including excavation of earth pit. supply of civil material, back filling, numbering of pits, including all labour and materials as per standard drawing complete as per specification of this tender and directions of Engineer-in-charge. |
27 | Termination of cable having outer diameter upto 40mm;CABLE TERMINATION : Termination of armoured power cables (Typically PVC/XLPE insulated up to 1100 V grade). Job includes earthing the cable armour, connecting to the terminals, supply and marking of upto 1100V 3/3.5/ 4 core of size wire number ferrules/ cable tags (ss/ aluminium/ lead strip minimum 2 mm thick and 20 mm wide at the termination point), drilling in equipment,removal, cutting , fixing of gland plate, fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, consumable items like Crimping paste, insulation Tapes, Including Supply of cable WP GLAND and LUGS etc complete, including all labour and materials complete, as per approved drawings, specifications of this tender and directions of EIC. |
28 | Termination of cable having outer diameter above 40mm;CABLE TERMINATION :Termination of armoured power cables (Typically PVC/XLPE insulated up to 1100 V grade). Job includes earthing the cable armour, connecting to the terminals, supply and marking of upto 1100V 3/3.5/ 4 core of size wire number ferrules/ cable tags (ss/ aluminium/ lead strip minimum 2 mm thick and 20 mm wide at the termination point), drilling in equipment, removal, cutting, fixing of gland plate, fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, consumable items like Crimping paste, insulation Tapes, Incliding Supply of cable WP GLAND and LUGS etc complete, including all labour and materials complete, as per approved drawings, specifications of this tender and directions of EIC. |
29 | Making horizontal bore under the WBM etc of the roads : Making horizontal bore under the WBM of the roads etc. manually or by machine for laying of upto 100 mm NB GI/ RCC pipes, excavating the side approach to facilitate boring, backfilling the same after completion of works including supply of tools , tackles,equipment etc. personal protective equipment to complete the job complete as required, excluding the supply of GI pipe as directed by Engineer-In -Charge. |
30 | Making of HT heat shrinkable cable joints and end terminations for indoor & outdoor as per requirement- including cutting, stripping of insulation etc. upto 400 sqmm excluding supply ofjointing kit and accessories including all labour and materials etc complete as required. 3 Core cables 11 kV, upto 400 sqmm. |
31 | Making of LT cable jointfor cables with OD upto 40 mm. HEAT SHRINK JOINTS : Making of heat shrinkable type straight through joints for 1100 volt grade PVC/XLPE cables as perspecifications, including cutting, stripping of cable insulation complete with supply of consumable, accessories etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge excluding supply of heat shrinkablejointing kit ." |
32 | Making of LT cable jointfor cables with OD above 40 mm. HEAT SHRINK JOINTS : Making of heat shrinkable type straight through joints for 1100 volt grade PVC/XLPE cables as perspecifications, including cutting, stripping of cable insulation complete with supply of consumable, accessories etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge excluding supply of heat shrinkablejointing kit." |
33 | LEAN CONCRETE (PCC 1:3:6)Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6graded stone aggregate 40 mm nominal size derived from natural sources) aggregate as leveling course in foundations, under slabs on grade etc., including tamping, curing, shuttering etc. complete for all depths and heights. Materials to be supplied as per approved vendor lists attached with special conditions of contract" |
34 | M-25 grade of concrete "FOUNDATION CONCRETEProviding and laying in position Reinforced Cement Concrete in open foundations, trenches, precast cover slabs of specified grade( design mix ) with 20mm and down size graded stone aggregates including screening and cleaning of coarse aggregates, fineaggregate (sand) conforming to proper grading, zone, both of approved quality and Ordinary POrtlamnd Cement , as necessary, cost of curing with water, excluding cost of centering and shuttering and reinforcement including providing pockets/ shear keys during concreting, vibrating, tamping, curing, sampling, testing and rendering if required, to give a smooth and even surface etc. including cost and carriage of all materials and including preparation of design mix, approval of the same by the Engineer-in-Charge, cost for quality control,sampling, testing etc. including cost of all material & labor in substructure, footings and other similar items not specifically mentioned herein, for all depths, complete as per drawings, specification and as directed by Engineer-in-charge/ owner. For details refer specification for Plain and Reinforced concrete. Materials to be supplied as per approved vendor lists attached with special conditions of contract.M-25 grade of concrete |
35 | Pre coated sheet Providing corrugated GS sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks,bolts and nuts,8mm diameter with bitumen and GI limpet washers or with GI limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete(upto any pitch in horizontal/vertical or curved surfaces), excluding the cost of perlins, rafters and trusses and icluding cutting into sizes and shapes wherever required 0.63 mm thick with zinc coating not less than 275 gm/m2 |
36 | BRICKWORK with common burnt clay locally available 1st class bricks for foundation and plinth etc. in Cement mortar 1:6 (1 cement : 6 coarse sand) incuding supply of bricks |
37 | RCC/PCC structure Breaking using Demolition Breaker (any thickness) |
38 | Brickwork structure Manual Breaking (any thickness) |
39 | Relocation / Shifting / Re-Installation of Existing High Mast including the existingfixtures, Feeder Pillar / MCB distribution box with earthing, lightning protections, glanding, termination of Incoming and outgoing Cables/ wires at luminaire and control gear box. |
40 | Visit of service technician ( 1 nos highly skilled per day)for service support of electrical package equipments |
41 | FORMWORKProviding and fixing plywood centring and shuttering straight / inclined, in foundations for footings, rafts, retaining walls, trenches, pedestals, pipe sleepers, culverts, drains, pipe way bridges, tunnels, liquid storage structures etc. including keeping the same in position during concreting and removal of the same after specified period, keeping necessary provision for inserts, projecting dowels etc., tools, equipments and labour necessary for the work all compete, and as specified and directed." |
42 | M-30 grade of concreteFOUNDATION CONCRETEProviding and laying in position Reinforced Cement Concrete in open foundations, trenches, precast cover slabs of specified grade( design mix ) with 20mm and down size graded stone aggregates including screening and cleaning of coarse aggregates, fineaggregate (sand) conforming to proper grading, zone, both of approved quality and Ordinary POrtlamnd Cement , as necessary, cost of curing with water, excluding cost of centering and shuttering and reinforcement including providing pockets/ shear keys during concreting, vibrating, tamping, curing, sampling, testing and rendering if required, to give a smooth and evensurface etc. including cost and carriage of all materials and including preparation of design mix, approval of the same by the Engineer-in-Charge, cost for quality control,sampling,testing etc. including cost of all material & labor insubstructure, footings and other similar items not specificallymentioned herein, for all depths, complete as per drawings,specification and as directed by Engineer-in-charge/ owner. For details refer specification for Plain and Reinforced concrete Materials to be supplied as perapproved vendor lists attached with special conditions of contract.M-30 grade of concrete |
43 | DEFORMED/TMT STEEL BARS FOR CONCRETE Supply and fixing in position TMT reinforcement bars Fe500D conforming to IS-1786 (FY=500 MPa) for RCC work including the cost of steel and cost of binding wire, carting the same to site of work, straightening, cleaning, cutting, binding with 18 SWG black soft annealed binding wire, and placing with proper cover blocks, supports, chairs, spacers, complete for all heights and depths complete as per drawing & specification. Materials to be supplied as per approved vendor lists attached with special conditions of contract. For payment reinforcement including authorized weight for spacer bars, laps, chairs etc shall be measured separately for diameter wise length actually used.Wastages & unauthorized laps shall not be considered for payment. Inspections and Tests as per relevant technical specifications and codes shall be deemed to be included in the scope |
44 | Supply of GI Earth Strip Size:25X5mm Galvanised with hot dip process Galvanisation thickness:610gm per Sqmtr. Avearge dft:86 microns Conforms to IS:2629/4759 |
45 | Laying, clamping and connecting of 25 x 5 mm GI earth strip for main earth grid/earthing network under ground, along structure, cable trays, racks walls, roofs, in trench etc. including excavation and filling of earth, chipping and remaking of concrete surface, supply and fixing of GI clamps, Supply of fixing GI fastners at earth plate & at equipment end wherever required. Supply & applying bitumin paint & hessian tape on underground joints & cold zinc spray on aboveground joints. Earthing to be carreid out as per IS:3043 It also includes any modification work because of fouling with under ground/above ground piping. |
46 | GI Earth Strip Size:50X6mm Galvanised with hot dip process Galvanisation thickness:610gm per Sqmtr. Avearge dft:86 microns Conforms to IS:2629/4759 |
47 | Laying, clamping and connecting of 50 x 6 mm GI earth strip for main earth grid/earthing network under ground, along structure, cable trays, racks walls, roofs, in trench etc. including excavation and filling of earth, chipping and remaking of concrete surface, supply and fixing of GI clamps,Supply of fixing GI fastners at earth plate & at equipment end wherever required. Supply & applying bitumin paint & hessian tape on underground joints & cold zinc spray on aboveground joints. Earthing to be carreid out as per IS:3043 It also includes any modification work because of fouling with under ground/above ground piping. |
48 | Supply,Installation,Testing and commissioning of CPRI approved 415V,3Ph, 1000 A LT Panel . The panel should besheet steel cubicle will be made of 14 SWG (2mm) CRCA sheet and 2 mm thick Passivated Gland Plate, dust and vermin proof, indoor type. ? Degree of protection: - IP42 as per IS 13947 INDOOR ? CABLE ENTRY: - The Cable Entry will be from Top/Bottom side only. ? Earth Bus: 25 x 5 mm GI Bus shall be provided throughout the length of the Panel Board. ? POWDER COATING: The Panel Boards shall be cured by 9 tank chemical tank treatment process. ? After that epoxy-based powder coated finish paints (two coats) shall be sprayed both inside and ? outside of the enclosures as per your specification. As per the attached SLD |
49 | House keeping, removal of debris,PM activities,material lifting and shifting as per requirement and direction of E-i-C(involving minmum 5 nos of semi skilled manpower per day) |
50 | Supply of Materials |
51 | PVC Insulation Tape, Length:25mtr,width:19mm.Make: Steelgrip/Stanvac/ Euro/Permacel |
52 | Supply of bicycle for men |
53 | Markin Cloth (Best Quality), Spec : 100%cotton Product only |
54 | Hand Gloves(Cotton) with PVC dotted forgrip. |
55 | Supply of electrical Insulating hand glovesmade of natural rubber ,clas-4, rolled edge, Length 410 mm , Maximum working voltage 36KV AC ,red colour ,size-10 conform to IEC 60903:2014 of make raychem model KL-F series or equivalent |
56 | Supply of PVC ferrule sleeve 4.5mm dia |
57 | Supply of PVC ferrule sleeve 3.2mm dia |
58 | Supply of wire stripper self adjusting crimping plier ratcheting ferrule crimping tool. Cable size : 0.08-10 mm2. |
59 | Supply of Mini OTDR as per following specification 1) Item: Mini-OTDR (Optical Time Domain Reflectomete) based system. 2)Make: The offer items shall be of internationally reputed brand. 3)Applicable Fiber: Single Mode, 4)Wavelength: 1310 nm +/- 25nm and 1550nm +/- 30nm, 5)Compatible fiber type: Single Mode, 6)Event Dead zone: 0.8m or better, 7)Attenuation dead zone: 4 meter or better for all wavelengths, 8)Dynamic range: 30dB or better, 9)Maximum distance range setting: 100KM or better, 10)Reflectance Range: -14dB to -65dB or better, 11)Reflection accuracy: +/- 2dB or better, 12)Sample resolution: 8 Cm or better, 13)Pulse width (minimum): 5 ns or better, 14)Power: Battery powered (minimum 5 hours of continuous, operations), 15)Operating Temperature: 0.0 to 50 DegC, 17)Storage facility: Shall have sufficient internal storage capacity with option for installing external stoage like memory card/pen drive etc. 18) Display size: Minimum 5 inch (or bigger) oudoor enhanced touch screen type display with facility for buttons 19) Other requirements: a)Shall provide Testing/Calibration Certificate. b)Operation Manual. c)Battery sets: 2 sets (1 set installed + 1 sets as spare) d)Protective hard PVC case box for carrying the complete set up and to prevent against physical damage. e)Complete set of accessories(like FO patch cables, fiber wipes, protective screen guard, PC interface cable with software/drivers etc) required for testing /checking of FO cables. f)Bidder shall provide an onsite training cum demostration of the unit after receipt of material at site |
60 | LED 15W Rechargeable Site Lamp Specifications: Lumen: 900W Power Source: 220 V AC for charging/ 12 V DC . Water & Dust Proof Rating: IP65. Run Time: 4hrs. Rechargeable Lithium Ion Battery. Portable free standing heavy base magnet |
61 | Supply of sealing compound (Bituminous tar/eqv) heating & pouring of compound in the metallic pipes for providing effective cable sealing. |
62 | Flexible Copper Cable; 3Cx2.5sqmm; 1100V grade; PVC insulated; PVC Sheathed;multistranded; unarmoured; conforming to IS:694; |
63 | Supply of 5Px0.5 mm non armoured telephone cable |
64 | Supply of 5/6 A, one way modular switch, ISI marked, Make - Havells/Anchor/Legrand/L&T or equivalent and as per the direction of EIC. |
65 | Supply of3 pin 5/6 A modular socket outlet, ISI marked,Make -Havells/Anchor/Legrand/L&T or equivalent and as per the direction of EIC. |
66 | Supply of 15/16 A, one way modular switch, ISI marked, Make - Havells/Anchor/Legrand or equivalent and as per the direction of EIC. |
67 | Supply of 6 pin 15/16 A modular socket outlet, ISI marked,White, Make - Havells/Anchor/Legrand or equivalent and as per the direction of EIC. |
68 | Supply of 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable, Make : Finolex, Rallison,Havells or equivalent and as per the direction of E.I.C. Colour : Red,Black,Green |
69 | Supply of 4 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable, Make : Finolex, Rallison,Havells or equivalent andas per the direction of E.I.C.Colour : Red,Black,Green |
70 | Supply of 6 A to 32 A ratings, SP MCB, “C” curve, 10 kA breaking capacity, Make : Legrand/Havells/Schneider or equivalent andas per the direction of E-I-C. |
71 | Supply of 6 A to 32 A ratings, DP MCB, “C” curve, 10 kA breaking capacity, Make : Legrand/Havells/Schneider or equivalent and as per the direction of E-I-C. |
72 | Supply of 40 A rating, 2 pole RCCB, 300mA, Make : Legrand/Schneider/L&T/ABB or equivalent and as per the direction of E-I-C. |
73 | Supply of 63 A rating, 4 pole RCCB, 30mA, Make : Legrand/L&T/Schneider or equivalent andas per the direction of E-I-C. |
74 | Supply of 4P MCB 63A “C” curve, 10 kA breaking capacity,Utilisation category A, Make Legrand/Havells/Schneider or equivalent and as per the direction of E-I-C. |
75 | Supply of 3P MCB 63A “C” curve, 10 kA breaking capacity,Utilisation category A, Make : Legrand/Havells/Schneider or equivalent and as per the direction of E-I-C. |
76 | Supply of 3P MCB 32A “C” curve, 10 kA breaking capacity,Utilisation category A, Make : Legrand/Havells/Schneider or equivalent and as per the direction of E-I-C. |
77 | Supply of 2P RCCB 25A ,300mA, Make : Legrand/Schneider/L&T/ABB or equivalent and as per the direction of E-I-C. |
78 | Supply of lugs of following sizes: 1. 2.5 sq. mm Cu Ring Type insulated. 2. 2.5 sq.mm Cu Pin type insulated. 3. 4 sq. mm Cu Ring Type. 4. 4 sq. mm Cu Pin Terminal Type. 5. 10 sq.mm Cu Ring Type 6. 10 sq.mm Cu Pin Terminal Type 7. 16 sq.mm Cu Ring Type 8. 25 sq.mm Cu Ring Type Qty of each size : 200nos Make: Dowells/Jainsons or equivalent and as per direction of E-i-C. |
79 | Electrical contact cleaner; CRC 2-26; Typical characteristics: Lubricating type; Applications: Helps to protect, lubricate and restore of electrical connectors , relays , circuit breakers ,Transformers , Switch gears etc ; Container size: 415 ml |
80 | Nylon Cable tie self locking(non releasable) of size 100mm X 2.5mm |
81 | Nylon Cable tie self locking(non releasable) of size 150mm X 3.5mm |
82 | Nylon Cable tie self locking(non releasable) of size 200mm X 3.5mm |
83 | Nylon Cable tie self locking(non releasable) of size 250mm X 3.5mm |
84 | Nylon Cable tie self locking(non releasable) of size 300mm X 4.5mm |
85 | Supply of saddle with Base Made of GI Zink materials Suitable for fixing of Cable / Conduit Pipe Dimension: Dia :20 mm, Width:13mm |
86 | Saddle with Base Made of GI Zink materials Suitable for fixing of Cable / Conduit Pipe Dimension: Dia :25 mm, Width:13mm |
87 | Nylon Hammer (1Kg) |
88 | Emery Paper: 280 x 230mm ; Silicon Carbon waterproof ; Gr 400 ; Make: Hindustan Carborunda / Carborundam Universal or equivalent |
89 | 12" Adjustable wrench, Non-Sparking, Beryllium free, Non-Magnetic & Corrosion Resistant durable Safety hand Tools meeting API standard. Tools material should be Aluminum Bronze and other Copper alloys. Valid Test Cetificate to be submitted |
90 | 8" Adjustable Wrench, Non-Sparking, Beryllium free, Non-Magnetic & Corrosion Resistant durable Safety hand Tools meeting API standard. Tools material should be Aluminum Bronze and other Copper alloys. Valid Test Cetificate to be submitted. |
91 | 8" Combination Pliers, Non-Sparking, Beryllium free, Non-Magnetic & Corrosion Resistant durable Safety hand Tools meeting API standard. Tools material should be Aluminum Bronze and other Copper alloys. Valid Test Cetificate to be submitted. |
92 | 8" Long nose pliers with cutters, Non-Sparking, Beryllium free, Non-Magnetic & Corrosion Resistant durable Safety hand Tools meeting API standard. Tools material should be Aluminum Bronze and other Copper alloys. Valid Test Cetificate to be submitted. |
93 | 450g/16oz Claw hammer with Fiberglass handle , Non-Sparking, Beryllium free, Non-Magnetic & Corrosion Resistant durable Safety hand Tools meeting API standard. Tools material should be Aluminum Bronze and other Copper alloys. Valid Test Cetificate to be submitted. |
94 | 3-pin Top Rating: 6A Voltage range: 240V AC Ivory colour Conforming to IS:6538. Make: Anchor(Anchor part No.3097) or equivalent |
95 | 3-pin Top Rating: 16A Voltage range: 240V AC Ivory colour Conforming to IS:6538. Make: Anchor (Anchor part No.3122) or equivalent |
96 | Suppl of self indicating Blue silica gel Mesh size:3-4(6-8 mm) . When free from moisture the crystals of silica gel to be blue and when take up moisture it should turn pink and need replacement or regeneration. |
97 | Supply of Transformer On-line oil leak Sealant,fast setting (within 2-3 minutes),having high bond strength & surface adhesion ,requires no surface preparation, resistance to acids, alkalis,chemical, temperature,easy to use kit for emergency leak sealing.Make:Devcon/ Stanvac/ Dow corning/ICC/Monarch |
98 | Self fusing Insulation tape having corona & ozone resistance UV resistance, moisture proof, chemical and corrosion resistance for outdoor & underground application.Can be used for voltage 600V-33KV.Recommended make:Stanvac/ Permacel |
99 | Supply of battery; 1.5 Volt ; Size: AA ;Make:Eveready/ Energizer or equivalent |
100 | Supply of battery; 9 Volt ; Size: 9V ; Make: Eveready/ Energizer or equivalent |
101 | Supply of Teflon Tape ; Size : 3/4" (Width) x 12 Mtr (length) ; Make: Champion |
102 | Supply of cable route tracer as per specification attached in Annexure |
103 | Multi Function Calibrators 20mA Thermocouples range J Frequency Resolution 1Hz Frequency range 1KHz RTD Accuracy 0.02 deg C Resistance Resolution 0.01 Ohm RTD range Cu10 Resistance accuracy 0.1% DC Current range 20mA RTD Resolution 0.01 deg C Resistance range 400 Ohm DC Current Accuracy 0.01% Frequancy accuracy %2 DC Current Resolution 0.001mA DC Voltage range 30V Thermocouples Resolution 1 deg C Thermocouples Accuracy 0.2 deg C DC Voltage Resolution 0.01mV DC Voltage Acuuracy 0.02% Side port connections Connection for optional battery charger/eliminator Relative Humidity 90 percent Display 4 and 5 Digits with Annunciator Battery Life 8 hour Warranty 3 year Standards EN50082-1:1992,EN55022:1994 Batteries 4AA Alkaline battery Display Type TFT disply Battery Replacement Replace without opening calibrator , no tools required Make: Fluke or equivalent |
104 | Supply of LED Tube light 1. Wattage: 18W - 20W 2. Operating Voltage range : 220-240V, 50 Hz AC System 3. Length of tube including pin: 1200mm 4. Type of lamp cap: G13 made of polycarbonate 5. Make : Philips/Havells/CGL/Bajaj or eqv. |
105 | Supply of Heat Shrinkable Straight through Jointing Kit for 0.5mm dia100 Pair PVC Insulated Jelly Filled Telephone Cable with all accessories. Make: Raychem or equivalent. |
106 | Supply of Heat Shrinkable Straight through Jointing Kit for 0.5mm dia5 Pair PVC Insulated Jelly Filled Telephone Cable with all accessories. Make: Raychem or equivalent |
107 | Supply of Heat Shrinkable Straight through Jointing Kit for 0.5mm dia10 Pair PVC Insulated Jelly Filled Telephone Cable with all accessories. Make: Raychem or equivalent |
108 | Supply of Heat Shrinkable Straight through Jointing Kit for 0.5mm dia50 Pair PVC I nsulated Jelly Filled Telephone Cable with all accessories. Make: Rayche m or equivalent |
109 | Supply of Heat Shrinkable Straight through Jointing Kit for 0.5mm dia20 Pair PVC I nsulated Jelly Filled Telephone Cable with all accessories. Make: Rayche m or equivalent |
110 | Supply of thermal scanning camera Lens Measurement Features Horizontal Field of View of Standard lens (degree)20-25 Vertical Field of View of Standard lens 14-20 Horizental Field of View of Telephoto lens NA Vertical Field of View of Telephoto lens NA IFOV of Standard lens (mRad) NA IFOV of Telephoto Lens (mRad) NA IFOV of (Spatial resolution) (mRad) 1.31 Performance Features Type Hand held Detector Resolution (minimum) (pixel) 75000 Temperature Range of Objects (Degree Celsius) -20 to +500 Temperature measuring accuracy of reading (or better) ± 2% oC Minimum Focus distance 20 Image capture frequency/ frame rate (Hz) N ? 9 Image Detector Type Uncooled focal plane array (FPA)Vox/ Asi/BST/Silicon Thermal sensitivity (NETD) 0.05 User selectable Emissivity setting/correction Between 0.01 and 1 Infrared spectral band (micrometer) Between 8 and 14 Image Palettes 6 Display Display Type Color LCD Display size 4 General Features Image capture, review and save mechanism One handed image capture, review and save capability Storage medium SD Memory card Size of USB stick 8 File formats JPEG Built-in digital camera/ Visual Camera Resolution (Mpixel) N ? 1 Details of Operating functions MSX, ULTRAMAX Facility for the adjustment/ selection of the time/date etc yes Interface for image transfer SD Memory card,WiFi,USB Cable with suitable drivers for downloading to PC Focus Manual & Auto other features LDM, METERLiNK Operating Conditions Minimum Operating Temperature -10 Maximum Operating Temperature 50 Operating Humidity (RH) 95 Power Requirement Power Requirements Battery Operated chemistry of the battery lithium ion Voltage of rechargeable Battery 3.6 Capacity of rechargeable battery (milliAH) 1500 Suitable charger/adapter provided yes Battery Backup 3 Power Management Automatic shut down /User Selectable On-screen battery level indicator yes Certification and Safety IP Protection IP54 Safety certification UL,CE Generic Size/ dimension 11.0 × 4.6 × 4.4 in. Weight (including batteries) 1 Automatic active temperature stabilization system of camera yes Provision for through-the-lens direct temperature measurement capability yes Test Report Details and Test The equipment supplied with calibration certificate yes conformity to Dry Heat for 16 hrs at a maximum temp in accordance with IS:9000/part-3/section-5/1977 latest No conformity to Cold Test for 4 hrs at a minimum temp in accordance with IS:9000/part-2/section-4/1977 latest No conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH No Availability of the test report from Central Govt/ NABL/ ILAC accredited lab to prove conformity to the specification No Test Report Number and date for the specification test (not a part of biddable parameter) NA Name and address of the Lab for the specification test (not a part of biddable parameter) NA |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail