| 1 | SUPPLY OF DC UPS WITH BATTERIES FOR MSB,GDS,PFCC UNIT FOR NREP PROJECT |
| 2 | Design, detail engineering, procurement, manufacturing, testing & inspection, packing, forwarding, transportation, route survey (if required), and supply till site including Commissioning spares, Mandatory spares , Special Tools & Tackles ,Consumables, 2 Year Operational Spares, Supervision and Site Installation & CommissioningofBattery Charger(s) with Battery banks complete with all accessories 160 Amps dual redundant Float cum Boost Charger for Switchgear control (Tag no. 1U64-SS16-ECH-503) + DCDB+ 2 nos. Battery isolator box with MCCB + Dual Ni-Cd Battery bank (100% capacity each & 1hr back-up each) with stand + Interconnection cables from Battery charger to Battery wand suitable termination arrangement on either sidesto be installed at Numaligarh Refinery Limited(NRL), Assam as per MRIncluding Cell Booster requirement as per MRCell booster: Input supply 240 V AC, 50 HzOutput Voltage : 0-12 V DCRating : 0.2 X Ah of cellQty shall be 1 nos. per battery bankCondition Monitoring Sensors and modules with required hardwares as per Specifications for above DC UPS (Battery Chargers) and Batteries -(1 Lot) |
| 3 | Design, detail engineering, procurement, manufacturing, testing & inspection, packing, forwarding, transportation, route survey (if required), and supply till site including Commissioning spares, Mandatory spares , Special Tools & Tackles ,Consumables, 2 Year Operational Spares, Supervision and Site Installation & CommissioningofBattery Charger(s) with Battery banks complete with all accessories 75 Amps Single Float cum Boost Charger for Critical Lighting (Tag no.- 1U64-SS16-ECH-504)+ DCDB+ 1 no. Battery isolator box with MCCB + Single Ni-Cd Battery bank (100% capacity & 1hr back-up) with stand + Interconnection cables from Battery charger to Battery wand suitable termination arrangement on either sidesto be installed at Numaligarh Refinery Limited(NRL), Assamas per MRIncluding Cell Booster requirement as per MRCell booster: Input supply 240 V AC, 50 Hx Output Voltage : 0-12 V DC Rating : 0.2 X Ah of cell Qty shall be 1 nos. per battery bank -(1 Nos.)Condition Monitoring Sensors and modules with required hardwares as per Specifications for above DC UPS (Battery Chargers) and Batteries-(1 Lot) |
| 4 | Design, detail engineering, procurement, manufacturing, testing & inspection, packing, forwarding, transportation, route survey (if required), and supply till site including Commissioning spares, Mandatory spares , Special Tools & Tackles ,Consumables, 2 Year Operational Spares, Supervision and Site Installation & CommissioningofBattery Charger(s) with Battery banks complete with all accessories 300 Amps dual redundant Float cum Boost Charger for Switchgear control (Tag no. 1U64-SS15-ECH-503) + DCDB+ 2 nos. Battery isolator box with MCCB + Dual Ni-Cd Battery bank (100% capacity each & 1hr back-up each) with stand + Interconnection cables from Battery charger to Battery wand suitable termination arrangement on either sidesto be installed at Numaligarh Refinery Limited(NRL), Assam as per MRIncluding Cell Booster requirement as per MRCell booster: Input supply 240 V AC, 50 HzOutput Voltage : 0-12 V DCRating : 0.2 X Ah of cellQty shall be 1 nos. per battery bankCondition Monitoring Sensors and modules with required hardwaresAs per Specifications for above DC UPS (Battery Chargers) and Batteries-(1 Lot) |
| 5 | Design, detail engineering, procurement, manufacturing, testing & inspection, packing, forwarding, transportation, route survey (if required), and supply till site including Commissioning spares, Mandatory spares , Special Tools & Tackles ,Consumables, 2 Year Operational Spares, Supervision and Site Installation & CommissioningofBattery Charger(s) with Battery banks complete with all accessories2) 90 Amps Single Float cum Boost Charger for Critical Lighting (Tag no.- 1U64-SS15-ECH-504)+ DCDB+ 1 no. Battery isolator box with MCCB + Single Ni-Cd Battery bank (100% capacity & 1hr back-up) with stand + Interconnection cables from Battery charger to Battery wand suitable termination arrangement on either sides to be installed at Numaligarh Refinery Limited(NRL), Assam as per MRIncluding Cell Booster requirement as per MRCell booster: Input supply 240 V AC, 50 HzOutput Voltage : 0-12 V DCRating : 0.2 X Ah of cellQty shall be 1 nos. per battery bankCondition Monitoring Sensors and modules with required hardwaresAs per Specifications for above DC UPS (Battery Chargers) and Batteries-(1 Lot) |
| 6 | Charges for SITE Supervision of Erection / Installation and Testing for SUPPLY OF DC UPS WITH BATTERIES FOR MSB,GDS & PFCC UNIT FOR NREP PROJECT as per MR |
| 7 | Per diem charges for upto 8 hours work on normal working days. |
| 8 | Overtime rate / hour beyond normal 8 hours work on normal working days. |
| 9 | Overtime rate / hour for work on weekly off days / holidays (as applicable to Refinery site). |
| 10 | Charges for Training at Vendor Works for DC UPS WITH BATTERIES FOR MSB,GDS & PFCC UNIT as specified in MR |
| 11 | Per diem charges for upto 8 hours work on normal working days. |
| 12 | Charges for Training at site for DC UPS WITH BATTERIES FOR MSB,GDS & PFCC UNIT as specified in MR |
| 13 | Per diem charges for upto 8 hours work on normal working days. |