Health and Family Welfare Government Departments Closing in 0 days TDR #35292984

Tender For Repair, Renovation Up Gradation Works For Infrastructure Strengthening Of Sub Centre To Be Upgraded To Suswsthya Kendras At Rambha Sc To Hwc Under Gopiballavpur-I Block, Jhargram .(Civil And Electrical Works)

Issued by Government Departments · rambha, West Bengal
Tender Value
7.52 Lakhs
Estimated cost
Bid Submission
23 Dec 2022
0 days left
EMD
15100
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
rambha → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair, Renovation Up Gradation Works For Infrastructure Strengthening Of Sub Centre To Be Upgraded To Suswsthya Kendras At Rambha Sc To Hwc Under Gopiballavpur-I Block, Jhargram . ( Civil And Electrical Works )

BOQ

Name of Work: Repair, Renovation up gradation works for infrastructure strengthening of sub centre to be upgraded to Suswsthya kendras at Rambha Sc to HWC under Gopiballavpur-I block, Jhargram .(Civil & Electrical works)
Sl. No. Item Description
1Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. Toilet area
2I) Cement concrete with graded stone ballast (40 mm size excluding shuttering)(A) [Pakur Variety]
3Repairing crack in wall by cement grout ing (1 : 2) including widening the crack on the surface (into V section) cleaning and packing the same with cement mortar (1 : 2) andfinishing off to match with adjacent surface. (Cement-69 Kg/100 m)
4At Gr. Fl.
5At 1st. Fl.
6(A) Stitching crack in brick wall by carefully cutting out face brick 125 mm. deep into the wall, cleaning the gap and filling up the same with precast cement concrete block carefully set in cement mortar (1:3) including
7(i) With plain cement concrete blocks(1:1½:3) with stone chips.
8(a) Block size 250 x 125 x 75 mm.,In GR.Fl
9Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.
10Total Gr. Fl............. (
11Total1st. Fl............. (
12Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m.
13a) In Gr. floor
14In 1st Floor
15Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceablematerials at site and removing rubbish as directed within a lead of 75 m.
16In Ground Floor , Store wall
17In 1st Floor
18Dismantling all types of plain cement concrete works, stacking serviceable materials at site andremoving rubbish as directed within a lead of 75 m.
19In ground floor including roof.
20(a) upto 150 mm. thick
21In 1st Floor
22Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.,
23a) Pakur Variety
24In ground Fl
25In 1st Fl
26Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. In Gr.Fl
27(i) Pakur Variety, Beam
28In 1st Floor
29Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. Gr.Fl
30i) Tor steel/Mild Steel,( Sail/Tata)
31In 1st Floor
32Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and (upto roof of ground floor)
33(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In- Charge.,
34In 1st Floor, Lintel Beam
35Brick work with 1st class bricks in cement mortar (1:6)
36(b) In superstructure, ground floor
37(c) In superstructure, 1st floor
38125 mm. thick brick work with 1st class bricks set in cement, sand mortar (1:4) in ground floor.
39In 1st Floor
40Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfer ing corners as directed , Gr.Fl (i) With 1:4 cement mortar
41(b) 10 mm thick plaster,
42(i) With 1:6 cement mortar
43(c) 15 mm thick plaster,
44(i) With 1:6 cement mortar
45(c) 15 mm thick plaster,
46In 1st Floor
47(i) With 1:4 cement mortar
48(b) 10 mm thick plaster,
49(c) 15 mm thick plaster, 1:6
50(i) With 1:6 cement mortar
51(c) 15 mm thick plaster,
52Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.
53In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).
54(ii) 25 mm. thick, In Gr.Fl
55(iii) Colouring pink, cream, yellow, green
56Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM (B) light colour
57In Gr. Floor
58In 1st.Floor
59Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.
60With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.
61C) In Gr. Floor
62In 1st Floor
63With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.
64(b) Area of each tile above 0.09 Sq.m
65(ii)Other than Coloured decorative incl white
66Wall, 1st. Fl
67Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and forjointing @1.8 kg/Sq.m]
68In 1st Floor, Lab
69Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m]
70In 1st Floor, Lab
71Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately) (a) Upto area 2.5 Sq.m
72In Gr.Fl
73In 1st.Fl
74Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).
75(h) Neem,Jam In Gr.Fl
76(h) Neem, Jam In 1st.Fl
77Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and otherfittings
78a) 35 mm thick shutters (single leaf
79In Gr floor.
80in 1st floor.
81Door
82Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)
83(b) 40mm X 6mm, 200mm Length
84Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.
85(vi) 100mm. X 50mm. X 1.25mm.
86i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.
87(a) 200mm long
88A) Iron door ring of approved quality fitted and fixed with nut and washer complete.
89(ii) 75mm dia.
90Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete.
91(iv) 300mm x 19mm dia. bolt.
92Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:
93(iii) 100 mm grip x 12 mm dia rod.
94Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mmcarriage of all materials, taxes and
95In Gr & 1st Floor
96Supplying, Fitting & Fixing 30 mm thick both side prelaminated Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of which 75mm shall be flat and 20 mm
97shall be tapered on both sides to form lock rail.
98Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, 10-12 Micron thickness Annodizing filmNatural white
99Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door with door spring, /aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer,door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing filmNatural white
100Supplying concealed type heavy duty PVC headed aluminium tower bolt for double leaf doors as per approved make and brand as per direction ofEngineer-in-Charge.(b) 250 mm long
101B) Supplying 125 mm. Dia acrylic handle for aluminium door as perapproved make & brand.(b) Colour
102Supplying 4 lever mortice lock or any approved make and brand as perdirection of the Engineer- in -Charge.ii) 100 mm.
103Supplying, fitting and fixing windows & ventilators with or without integarted grills cionforming to I.S. 1038-1975 and manufactured from rolled steel sections conforming to I.S. 7452-1974.
104b) Openable steel windows as per I.S. sizes with side hung shutters and horizontal glazing bars, with or without fixed type ventilators ( the rate
105In Gr. Fl, for V
106In 1st . Fl, for V1
107c) M.S integrated grill as per approved design integrated with steel window or ventilator, joints
108continiously welded with M.S flats and bars., Gr.Fl
109In 1st Floor
110Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than150mm apart complete in all respect as per design including cost of all labour and materials.
111In Gr.Fl Floor
112In 1st Floor
113(a) M.S.or W.I. Ornamental grill of approved design joints contin uously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.
114(i) Grill weighing above 10 Kg ./sq .mtr and up to 16 Kg./sq. mtr.
115In Gr.floor
116In 1st floor
117Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.
118i) 4mm thick clear glass. Sliding
119Square or hexagonal mesh netting made with 18 B.W.G. galvanised wire, fitted and fixed complete as per design (excluding the supporting framework but including local sal wood battens of size 37.5mmx25mm).In ground floor..
120(b) 25mm mesh
121(b) 25mm mesh
122(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
123i) On Plastered surface ,Gr.Fl.+1st Fl
124(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
125(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :
126iv) Two coats (with any shade except white)
127On Plastered surface, Gr.Fl +1st
128On Timber surface, Gr.Fl +1st
129Other metal Surface, Windows,
130Grills Etc.
131Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge)
132In Gr. Fl
133In 1st. Fl
134Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish)
135a) One Coats, Gr. Fl
1361ST Fl.
137Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.
138In Ground floor (Two Coat)
139a) Normal Acrylic Emulsion
140In 1stfloor (Two Coat)
141Labour for Chipping of concrete surface before taking up Plaster ing work.
1421stfloor roof,deduct mumty
143(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with waterin proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer\"s specification 1ST Fl.
144Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as perrelevant IS codes. 1st Fl.
145Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer\"s specified rate) for concrete of variousgrades.
1461.5 mm thick Net cement finish in wall, dado,outside washing
147Main signageof Vinyle Board with ACP Boarder 1800X1200 mm
14810 nos Name plate ( 300x150mm)
149S & P work
150Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer a) 1000 ltr capacity
151Labour for hoisting plastic water storage tank. i) Upto 1500 litre capacity.
152Labour for punching hole in plastic water storage tank upto 50 mm dia.
153Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding \"P\" or \"S\" trap (excluding cost of concrete for fixing). i) 580 mm X 440 mm
154Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts,nuts etc. (a) With \"P\" trap
155Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately). (i) 450 mm X 350 mm
156Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. (b) Anglo Indian (i) Plastic (hallow type) White
157Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
158Supplying, fitting and fixing white vitreous china best quality approved make Wash basin with C.I brackets on 75 mm x 75 mm wooden blocks, C.P. waste fittings of 32 mm dia, one approved quality brass C.P. pillar cock of 15 mm dia, C.P. chain with rubber plug of 30 mm dia, approved quality P.V.C waste pipe with C.P. nut 32 mm dia, 900 mmbrackets with two coats of approved paints(ii) 550 mm x 400 mm
159Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (ii) 530 mm x 430 mm x 180 mm
160(iv) Angle back wash basin 400 mm X 400 mm
161Wash basin vitreous china of approved make (without fittings) supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets. (iv) 400 mm x 400 mm
162Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps.
163(ii) 750 mm long
164Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.(ii) 750 mm long
165Supplying, fitting and fixing pillar cock of approved make.
166f) (i) CP Pillar Cock with 200 mm extended Lever Handle (Equivalent to Code No. 5031 & Model - FLORENTINE of JAQUAR or similar brand).
167a) (ii) CP Pillar Cock Super Deluxe with Aerator - 15 mm. (Equivalent to Code No. 508 & Model No. Tropical / Sumthing Special of ESSCO or similar brand).
168Supplying, fitting and fixing bib cock or stop cock.
169(a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
170(b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar
171(e) PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm
172Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992
173Rain Water Pipe :-
174Supply fitting & fixingof UPVC pipes (B Type) & fittings conforming to IS-13592-1992, Single Socketed 3 Meter Length, 75 mm , In mumty room
175(B) Fittings
176(ii) Plain Tee 110 mm
177v) Plain Y 110 mm
178x) Bend 87.5º 110 mm
179xi) Door Bend (T.S.) 110 mm
180xvi) Pipe Clip 110 mm
181xxvi) Reducer 110 X 75 mm
182xxxi) Plain Floor Trap with Top tile & Strainer 75mm
183Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings For Concealed Works
184ii) 15 mm dia. medium quality
185(ii) 25 mm dia. medium quality
186Supplying, fitting & fixing PVC Pipes of approved ( Medium duty)make with all necessary accessories specials viz bent, union cross elbo etc.
187(i) 15mm dia midium quality
188(ii) 25mm dia midium quality
189(iii) 50 mm dia midium quality
190Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges.
191(ii) 600 mm X 450 mm
192Supplying, fitting and fixing soap holder.
193(b) Fibre glass
194Supplying, fitting and fixing towel rail with two brackets.
195(i) 25 mm dia. and 600 mm long
196Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brickwork, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and1.00m inside dia
197Electrical Work
198Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. fittings as required
1992 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC[1(iii). / E-14]
200Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2012x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [9(ii)/F-5]
2022 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [9(i)/F-5]
203Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building work (E-13/10(b))
204Wiring in 1.1 KV grade single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. ( Page No. : E-11 Item No. : 1.)
2052 x 36/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC[1(b). / E-11]
2062 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC[1(c). / E-11]
207Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface] (E-11/2)
208Average run 6 mtr (Sub. Item No. : (b))
209Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to 5A 3 pin flush type plug socket with piano key type switch (Anchor make) fixed on sheet steel fabricated CRC MS switch board with bakelite/perspex (wall matching color) top cover of 3 mm thick flushed in wall by housing the board after cutting brick wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface] (Page No. : E-12 Item No. : 6.)
210On Board
211Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light point with 2 no. 2 way piano key type switch fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casingcapping and Switch board both on surface] ( Page No. : E-11 Item No. : 3.)
212Average run 9 mtr (Sub. Item No. : (a))
213Supplying and fixing Sheet steel Main Switches on flat iron frame on wall
214DP 32 A (Page No. D1 item No.1(a)) Make - HPL/Havells
215Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
21625 A DP MCB [Make - Legrand / Schneider] (Page No. D 6 item No.7) [Emergency DB Incomer, 1st floor and Ground Floor Incomer]
2176-20 A SP MCB [Make - Legrand / Schneider] (Page No. D 6 item No.7)
218Supplying and fixing double-door SPN MCB DistributionBoard with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
2192+12 Way enclosure(607712) [Make - Havells/ Legrand / Schneider] (Page No. D 9 item No.13) [Emergency DB]
220Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Page No. E 18, item No. 9(b))
221Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Page No. E 18, item No. 9(a)) (For Television and Exam Light)
222Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(Page No. E 18, item No. 12) (For Computer Board CHO ROOM,)
223Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.( E-6/18(a))
224Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessaryconnection as required by 2x1.5 sqmm flexible copper wire. ( C-3/21(a))
225Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 30 cm (12\") ( C-4/28)
226Supply & Fixing louver shutter on wall with necy.. bolts & nuts (6 mm dia x 62 mm long ) For Al : 30 cm Exhaust fan (12\")( D-14/32(a))
227Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long ) or as reqd. Incl. S&F 24/0.02 PVC insulated Flexible copper wire 0.5 mt.length (C-4/29)
228Supply of 48 inch sweep ceiling fan Similar to --Orient New Breeze/Summer King/Usha-Striker make (Rate Analysis at SPMU )
229Supply of 12inch sweep heavy duty exhaust fan Similar to---EPC make/Orient (Rate Analysis at SPMU)
230Supply & delivery of single 4ft LED tube light fitting incl. 4ft LED tube (Mas LEDtube 1200mm) , complete with all accessories. [Philips: TMC 501 P 1xT-LED 22W P3241] or equivalent of Havells, Crompton etc. [Rate Analysis at SPMU]
231Supply & Delivery at site 9 watt LED Bulb[Make-Crompton] or equivalent of Havells, Philips etc. [Rate Analysis at SPMU]
232Supply & Fixing full Metal body AC Cabin fan 16\" sweep with net guard and all accessories ( Make EPC Tempest / cinni / CG) ( Rate taken from PWD Executive Engineer vetting Estimate)
233Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener (C-2/14 (b))
234Fixing only lamp(C-2/11)
235District Charge for Electrical Schudle Item
236Total G.S.T for the whole Work
237Total Labour welfare Cess for the whole Work

AI Tender Summary

OUR REF NO 35292984
AUTHORITY Government Departments
TENDER VALUE 7.52 Lakhs
LAST DATE 23-12-2022
Authority
Authority Name Health And Family Welfare Department
Work Description Repair, Renovation Up Gradation Works For Infrastructure Strengthening Of Sub Centre To Be Upgraded To Suswsthya Kendras At Rambha Sc To Hwc Under Gopiballavpur-I Block, Jhargram . ( Civil And Electrical Works )
Basic Detail
Tender No DHFWS/JGM/2022/2302
Bidding Type Tender
Location
City rambha
State West Bengal
Key Dates
Publish Date 15 Dec 2022
Submission Date 23 Dec 2022
Open Date 26 Dec 2022
Finance
Tender Value 7.52 Lakhs
Tender Fee Ref. Documents
EMD 15100
Exemption Not Available
Document List
c4fd5827-3bb3-4bfd-971d-7d5e460c01c5.html
BOQ_859618.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 15, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 23, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 26, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

c4fd5827-3bb3-4bfd-971d-7d5e460c01c5.html

xls

BOQ_859618.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender