Military Engineer Services-MES has published Tender For Repairs To Generators Lt Feeder Pillar Boxes Apfc Panels And Allied Works Under Ge Panaji Goa. Submission Date for this Tender is 04-01-2023. Feeder Pillar Tenders in panaji Goa. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 28-Dec-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 04-01-2023 |
Sl. No. | Item Description |
1 | Comprehensive Maintenance of DG set andnormal repairs including replacement of defective and worn out filters, gaskets,V- belts, Engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet settings if required and greasing of bearings of engine and alternator, checking of batteries, applying petroleum jelly to battery terminals, adding distilled water checking the oil, coolent levels of following capacity at various loacation Altino, Bambolim, Ponda and Madgaon under GE Panji,Goa. Note:- Spare parts required for maintenance will be measured and paid separately. |
2 | 125 to 160 KVA Make: Kirloskar |
3 | 100 KVA Make : Kirloskar |
4 | 82.5 KVAMake : Ashoka Leylend |
5 | 62.5 KVAMake : Kirloskar |
6 | 35 KVA Make : Kirloskar |
7 | 10 to 25 KVAMake : Kirloskar |
8 | Supply and fix diesel filter element with "O" ring suitable for DG set of the following capacity including removal of existing unserviceable one complete all as specified and as directed. |
9 | 125 to 160 KVA |
10 | 100 KVA |
11 | 82.5 KVA |
12 | 62.5 KVA |
13 | 35 KVA |
14 | 10 to 25 KVA |
15 | Supply and fix Spin-on filter element for lubricating oil with "O" ring suitable for DG set of the following capacity including removal of existing unserviceable one complete all as specified and as directed. |
16 | 125 to 160 KVA |
17 | 100KVA |
18 | 82.5 KVA |
19 | 62.5 KVA |
20 | 35 KVA |
21 | 10 to 25 KVA |
22 | Supply and fix bypass filter element with "O" ring suitable for DG of the following capacity set including removal of existing unserviceable one complete all as specified and as directed. |
23 | 125 to 160KVA |
24 | 100 KVA |
25 | 82.5 KVA |
26 | 62.5 KVA |
27 | 35 KVA |
28 | 10 to 25 KVA |
29 | Supply and fix air filter element suitable for DG set of the following capacity including removal of existing unserviceable one complete all as specified and as directed. |
30 | 125to 160KVA |
31 | 100KVA |
32 | 82.5 KVA |
33 | 62.5 KVA |
34 | 35 KVA |
35 | 10 to 25 KVA |
36 | Supply and fix fan Belt complete suitable for DG set of the following capacity compete all as specified and as directed. Make :- Fenner/ Dunlop. |
37 | 125 to 160KVA |
38 | 100 KVA |
39 | 82.5 KVA |
40 | 62.5 KVA |
41 | 35 KVA |
42 | 10 to 25 KVA |
43 | Supply and fix Belt for battery charging alternator complete suitable for DG set of the following capacity compete all as specified and as directed. Make :- Fenner/ Dunlop. |
44 | 125 to 160 KVA |
45 | 100 KVA |
46 | 82.5 KVA |
47 | 62.5 KVA |
48 | 35 KVA |
49 | 10 to 25 KVA |
50 | Supply and fix rubber hose pipe set for water circuit with clamps complete suitable for DG set of the following capacity compete all as specified and as directed. |
51 | 125to 160KVA |
52 | 100 KVA |
53 | 82.5 KVA |
54 | 62.5 KVA |
55 | 35 KVA |
56 | 10 to 25 KVA |
57 | Supply and fillEngine oil, multi grade premium Genuine oil 20W/ 40 as per manufacturer recommendations in DG sets including removal of burnt oil complete all as specified and as directed.Make :- Indian oil/ Hindustan Petroleum/ Castrol/ BPCL |
58 | Supply and applying Petroleum Jelly (01 Kg plastic sealed container) complete all as specified and as directed. Make :- Indian oil/ Hindustan Petroleum/ Castrol/ BPCL |
59 | Supply and fill distilled water for topping up in lead acid batteries complete all as specified and as directed. |
60 | Supply and fill electrolyte of suitable specific gravity for lead acid batteries in sealed container complete all as specified and as directed. |
61 | Dismantling of worn out battery clamp and battery connecting wire made of copper 1.5 mtr long and replacement of battery clamp heavy duty 02 Nos in one side and 2 Nos lugs on other side of suitable sizes fixed complete all as specified as directed. |
62 | Material and labour forbattery terminal brass clamps including removal of extg unserviceable one complete all as specified and as directed by Engr-in charge. |
63 | Material and labour for water temperature gauge including sensor and cable complete as per sampleincluding removal of extg unserviceable one complete all as specified and as directed. |
64 | Material and labour for dismantling the radiator taking to work shop for overhauling & cleaning, de-scaling with acid, removal of leakage including soldering and welding, brazing as required and renewal of gaskets, nuts, bolts, mounting pads, hoses, clips, etc and refixing in its original position for following capacities of DG set complete all as specified and directed |
65 | (a) 10 to 25 KVA DG set |
66 | (b) 62.5 to 82.5KVA DG set |
67 | (c) 100 to 160 KVA DG set |
68 | Material and labour for repair and calibration of FIP and injectors from authorised dealer for petty repairs to make the FIP functional as per standard calibration procedure and norms including replacement of minor spares, gasket etcfor smooth functioning of FIP and refixing its original position includingtesting at site for following capacities of DG set complete all as specified and as directed. |
69 | 125 to 160 KVA DG set |
70 | 100 KVA DG set |
71 | 62.5 to 82.5KVA DG set |
72 | 10 to 35 KVA DG set |
73 | Material and labour for Repair/ overhauling of self starting system of DG set including replacement of carbon brushes, bearings, bushes, rewinding of armature and field coil etc and varnishing of capacity 12/24 volts with necessary connectionsincluding testing and commissioning complete all as specified and as directed. |
74 | Supply and fix in repair battery charging circuit suitable for 12/24 volts, DC in existing DG set panel board including addition/ alteration in wiring system complete with auto transformer, diodes, filter circuit, condensers, DC ammeter, DC volt meter with selector switches and indicating bulbs etc complete all as specified and as directed. |
75 | Material and labour forAVR (automatic voltage regulator)control unitassembly suitable for 10 KVA DG set to 125 KVA DG set including removal of extg unserviceable one complete all as specified and as directed. |
76 | Material and labour for fuel steel braided pipe with banjo bolts and washers etc of length 30 cm long including removal of extg unserviceable one compete all as specified and as directed. |
77 | Material and labour for fuel steel braided pipe with banjo bolts and washers etc of length 45 cm long including removal of extg unserviceable one complete all as specified and as directed. |
78 | Material and labour for canopy hinges for aquatics doors with suitable bolts and nuts of DG set including removal of extg unserviceable one complete all as specified and as directed. |
79 | Supply and fix for digital type frequency meter 96 x 96 mm flush /square pattern including removal of extg unserviceable one complete all as specified and as directed by Engr-in charge.Make- L&T/AE or equivalent. |
80 | Supply and fix for digital type volt meter 96 x 96 mm flush /square pattern including removal of extg unserviceable one complete all as specified and as directed by Engr-in charge. Make- L&T/AE or equivalent. |
81 | Supply and fix for Power Contactor 415 Volt, 50 Hz AC suitable for DG set control panel/ AMF panel for following capacity of DG set including removal of extg unserviceable one complete all as specified and as directed.Make:- Simens/ L&T/ ABB/ C&S/ Schneider. |
82 | (a) 10 to 35 KVA DG set |
83 | (b) 35 to 62.50 KVA DG set |
84 | (c) 62.5 to 82.50 KVA DG set |
85 | (d) 100 to 160 KVA DG set |
86 | Supply and fix for Time delay relay suitable for 10 KVA DG set to 62.5 KVA DG set including removal of extg unserviceable one complete all as specified and as directed.Make:- Simens/ L&T/ ABB/ C & S |
87 | Supply and fix for Time delay relay suitable for82.50 KVA DG set to 125 KVA DG set including removal of extg unserviceable one complete all as specified and as directed.Make:- Simens/ L&T/ ABB/ C & S |
88 | Material and labour forsolenoid switch assembly 12/24 volts suitable for 10 KVA DG set to 125 KVA DG set including removal of extg unserviceable one complete all as specified and as directed by Engr-in charge. |
89 | Supply and fixfor battery low maintenance lead acid of capacity 12 volts 120 AH with initial charging including removal of extg unserviceable one complete all as specified and as directed by Engr-in charge. Make:- Exide/ AMCO/ Amaron |
90 | Supply and fix for solenoid valve suitable for following capacity of DG sets for smooth function of DG sets including removal of extg unserviceable onecomplete all specified and as directed. |
91 | (a) 10 KVA DG set to 82.5 KVA DG set |
92 | (b) 100 KVA DG set to 160 KVA DG set |
93 | Material and labour for draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel, calibration of Diesel tank and replace the transparent diesel indicator hose complete providing new scale/fuel indicator for diesel tank of 62.5 KVA to 125 KVA DG set complete all as specified and directed. |
94 | Servicing the silencer assembly , remove the complete silencer assembly from DG set by removing nuts bolts complete , including opening the wall of silencer outlet remove the old asbestos rope on silencer complete, remove the blockage complete , reassemble the silencer with DG set with new gasket, nut, bolts & washers , gas welding on damaged portion on silencer pipe complete, providing glass wool insulation over silencer and its pipe not less than 100 mm thick from DG set mouth to exhaust pipe complete providing GI sheet gladding over insulation complete and riveting the GI Sheet gladding including fixing all assembly with wall/ceiling of DG set room , finishing the opening of wall of DG set room matching to existing surface complete DG set 62.5 KVA to 125 KVAall as specified and directed. |
95 | Material and labour for chart/ diagram/ name plates/ details of DG sets made out of bakelite hylem sheet, ISI marked, 3 mm thick , cutting to shape /size including fixing of adhesive transparent filament of red/ blue colour including cutting of filament of letters/ figures/ diagrames/ details of suitable size/ type all as directed including fixing to the wall by wooden screwand PVC hold fast etc complete all as directed and specified. Note :- Matter/ figure/ chart/ diagrams/ letter shall be give by the Engineer- in- Charge) |
96 | Supply and fix connecting and testingopen execution on load change over inexisting DG set Panel of the following capacity, suitable for 415 volts, 50 Hz, with extended terminals type, interlocked to prevent opening when the Switch is in ON Position, connecting and testing complete including removal of exiting unserviceable one all as specified and directed.Make:-ABB/ Siemens/ Schneider/Legrand. |
97 | (a) 4 pole 63 Amps |
98 | (b) 4 pole 100 Amps |
99 | (c) 4 pole 125 Amps |
100 | Supply and fill genuine coolant in 5 ltrs plastic sealed container for topping up in Radiator of DG set located at different locations as directed by Engr-in-Charge complete all as specified and as directed. |
101 | Cleaning of diesel tank of various capacity DG set inside/ out side tank location, complete with drain out DHPPN and cleaning tank and refilling the DHPPN testing complete all as directed. |
102 | Material and labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strips 25 x 4 mm as earthing lead by mean of nut/bolt and washer of galvanized iron or steel drawn through 4.0 mm dia light grade GI pipe as shown in electrical plate No 5 of SSR part I of 2009 including necessary excavation and earth work GI pipe 20mm dia light grade for wateringPCC chamber with PCC cover in cement concrete 1:2:4 (Type B1) using 20mm graded stoneaggregate, funnel, wire mesh, charcoal dust, salt etc, connected to panel board as indicated including testing complete. |
103 | Material and labour for preparation of old painted surfaces of LT panel of various capacities, and apply two coat of weather proof acrylic emulsion paint of gray colour on both sides by mechanic sprayer, including repair/replacement of panel door"s nut & bolts/hinges/bolt etc for smooth functioning to open and close of doors etc complete all as specified and as directed. |
104 | Material and labour for the following capacitor suitable forAPFC panel etc complete all as specified and directed. |
105 | (a) 2 KVAR |
106 | (b) 3 KVAR |
107 | (c) 5 KVAR |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy