03-01-2023

Tender Details

Provision Of Mast At Quarter Deck At Ins Valsura, Jamnagar - Taking Down Cement Plaster Of Any Description Including Racking Out Joints, Hacking For Key Scrubbing Down With Water Etc And Removal Of Entire Debris As Ordered Outside Md Land Complete All As Directed. 2 Demolition Of Cement Concrete ( Un-Reinforced ) In Ground Floor And Paving Not Exceeding 15 Cm Thick Above Or Below Ground Level And Removal Of Entire Debris As Ordered Outside Md Land Complete All As Directed. 3 Dismantling Floor, Hearth Or Wall Tiling Inluding Cement Mortar Bedding ( But Not Backing ) , Stackingserviceable Tiles At Site Andremoval Of Entire Debris As Ordered Outside Md Land Complete All As Directed. 4 Excavation In Over Areas Not Exceeding 1.5M Deep And Getting Out In Soft / Loose Soil Complete All As Directed. 5 Excavation In Over Areas Not Exceeding 1.5M Deep And Getting Out In Soft / Disintergrated Rock Complete All As Directed. 6 Excavation In Over Areas Exceeding 1.5M And Not Exceeding 3.0M Deep And Getting Out In Soft / Disintergrated Rock Complete All As Directed. 7 Returning Filling In Trenches Including Spreading, Leveling, Watering And Well Ramming In Layers Not Exceeding 25 Cm Thick In Soil Complete All As Specified And Directed. 8 Removing Excavated Surplus Soil To A Distance Exceeding 1.5 Km But Not Exc 5 Km And Depositing Where Directed At A Level Not Exceeding 1.5 M Above The Starting Point Complete All As Directed. 9 M&L For Pcc1:4:8, Type D2 ( Using 40 Mm Graded Crushed Stone Aggregate ) As In Foundation Filling, Mass Concrete Complete All As Specified And Directed 10 M&L Factory Made Pre Cast Pcc 1:3:6, Type C1 ( Using 20 Mm Graded Granite Aggregate ) As In Block Masonry With Solid Blocks, Exceeding 10 Cm In Width And Setting In Cm 1:6 Complete All As Specified. 11 M&L Rcc M-30 ( Using 20 Mm Graded Granite Stone Aggregate ) As In Foundation, Including Rafts, Footings, Foundation Beams, Plinthbeams, Base Of Columns Etc And The Like Complete.Note: Reinforcement Shall Be Measured And Paid Separately. 12 Formwork To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits ( If Any ) Of Foundation And Plinth Beams And Similar Work, Vertical Or Batter, Flat Fair Finished Surface All As Specified. 13 S&F Hot Dipped Galvanised ( 80 Microns As Per Is 4759 ) Structural Steel Tapered Pipe ( 500Mm Dia At Bottom And 300Mm Dia At Top With 16Mm Thick Throughout ) Of 30M High From Base Plate As In Aerial Masts And Cross Arms At Various Heights Using Tappered Pipe As Directed Including Gusset Plates, Stiffner, Channels, Square Cut Or Notched, Forming Holes With Revetted, Bolted Or Welded Attachement Confirming To Conforming To Fe-410W ( Gde-E-250 ) Quality B Complete All As Specified And As Directed. 14 S&F Factory Hot Dipped Galvanised ( 80 Microns As Per Is 4759 ) Mild Steel Work In Framed Work Such As Grills, Framed Guard Bars, Gratings, Ladders Etc., With Ends Of Bars Shouldered And / Or Riveted, Or Forged Into Spikes, And Similar Work. 15 S&F Factory Rolled Hot Dipped Galvanised ( 80 Microns As Per Is 4759 ) Mild Steel Plates ( Plain Or Chequered ) Channels, Square Cut Or Notched ( Ordinary And Counter Sunk ) , Forming Holes, With Riveted, Bolted Or Welded Attachment Confirming To Fe 410-W ( Gde-E-250 ) . ( Note For Itemno 14 & 15: ( I ) The Work Tobe Executed In Height More Than10 Mtrs From Ground Level . ( Ii ) Necessaryscafloding As Per Relevant Safetyis Norms Shall Be Followed & The Same Tobe Got Approved Be Engineer-In-Charge Before Commencementwork. ( Ii ) . All Tradesman Involved In The Taskshould Pocesses Validinsurance &The Same Tobe Submitted To Engineer-In-Charge For Verification & Record. ( Iii ) All Necessary Saftey Precautionery Equipments As Per Is Such As Hand Gloves , Safety Belt , Head Helmentetc Shall Be Arranged By The Contractor Without Any Extra Cost To Govt ( Iv ) The Quoted Rate Aganist The Said Items In Boq Is Deemed To Be Inclusive Of The Same & No Extra Shall Be Admissible. Contractor Must Visit The Site Prior Quoting His Bid To Have A Better Assessement. 16 S&F Factory Hot Dipped Galvanised ( 80 Microns As Per Is 4759 ) Mild Steel Anchor Bolts, Straining Bolts Of Any Dia Incl Nuts And Washers Complete. ( Note For Item Nos. 15 & 16: Work Shall Be Carried Out On Height More Than 10 Meter ) 17 S&F Galvanised Structural Mild Steel Ropes Of 15Mm Dia And Fixed As Directed. 18 S&F Galvanised Structural Mild Steel Ropes Of 10Mm Dia And Fixed As Directed. 19 S&F Stainless Steel Pulleys ( Grade 316 Ss ) To Accommodate 10Mm Dia Rope For Hosting Flags, Etc Complete All As Specified And As Directed. 20 S&F 10Mm Dia And Over Crs Tmt Bars, Cut To Length Bent To Shape Required Cranking Including Bending, Hooking Ends Etc And Binding With Mild Steel Wire ( Annealed ) Not Less Than 0.9 Mm Dia Or Securing With Clips Complete All As Specified And As Directed. 21 All As Per Item No. 20 Here- In – Above But5 Mm Diaand Over Upto 10 Mm Dia As In Stirrups 22 S&F Stainless Steel Pipe For Posts And Struts ( Grade 316 Ss With Medium Weight Sections ) Comprising Any Dia Ss Pipe Welded, Buffed Incl Hooks For Tying Rope, Etc Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature ( Where Ever Required ) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, Including Fixing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size Complete All As Specified And As Directed. Complete All As Specified And As Directed. 23 S&F Brass Plaates Of Any Thickness Including Welding Complete All As Specified And As Directed. 24 M&L For 100Mm Thick Pcc 1:4:8, Type D2 ( Using 40 Mm Graded Crushed Granite Stone Aggregate ) As In Sub Base, Floors, Pavings Etc. Finished Fair And Even Complete All As Specified. 25 M&L 20 Mm Thick Granite Slab ( Of Any Type ) Work ( Table Rubbed, Polished And Rounding Of Edges Where Ever Necessary As Ordered ) Bedded And Jointed With Grey Cement Slurry And Pointed With White Cement With Admixture Of Pigment To Match The Shade Of Granite Stone Laid Over And Including 15Mm Thick Screed Bed In Cement Mortar 1:6 Complete All Directed And Specified. 26 All Same As Per Item No. 25 Here-In-Above But As In Dado & Skirting With 10Mm Thick 1:4 Cement Mortar Screed - Do - ( Note For Item No 25 & 26: I ) Quoted Rate Is Deemed To Be Inclusive Of Cement Screed / Plaster. ) 27 M&L For Point Wiring With 1100 V, 1.5 Sqmm Single Core Pvc Frls Insulated Unsheathed Cable, Copper Conductor Multistranded Passing Through Including Pvc Concealed Conduit 20Mm, Concealed Ms Box / Pvc / Ms / Cast Iron Box And Logic Modular Whtie Plates Of Suitable As Required At Site With Pvc Insulated Unsheathed Stranded Copper Of Size 1.5 Sqmm Earth Copper Cable, For One Light Point, Bell Point, Fan Point Controlled By One Switch Including Cutting And Making Good Surface Of Walls Applying Suitable Painting As Required All As Directed. 28 All As Per Item No. 27 Here-In-Above, But For 6 Amp ( 2 / 3 Pin ) , Modular Switch Socket In Same Board With Earth Wire 1.5 Sq.Mm Pvc Insulated Multistranded Copper Conductor Cable Complete All As Directed. 29 All As Per Item No.27 Here-In-Above, But For 6 Amp ( 2 / 3 Pin ) , Modular Switch Socket In Independent Board With Earth Wire 1.5 Sq.Mm Pvc Insulated Multistranded Copper Conductor Cable All As Directed. 30 All As Per Item No. 27 Here-In-Above, But Size Of Cable 2.5 Sq.Mm For 16 Amp And 6 Amp ( 3 Pin ) Combined, Modular Switch Socket In Independent Board With Earth Wire 2.5 Sq.Mm Pvc Insulated Multistranded Copper Conductor Cable All As Directed. 31 S&F Modular Switch 1 Way 6 Amps, 1 Module All As Specified And Direced. 32 S&F Modular Switch 1 Way 16 Amps, 1 Module All As Specified And Direced. 33 S&F Modular Socket 6A -2 / 3 Pin Combined 2 Module All As Specified And Directed. 34 S&F Modular Socket 16A -2 / 3 Pin Combined 2 Module All As Specified And Directed. 35 S&F 10 Watt Wall Mounted 2 Ft Glaze Led Batten Cct ( K ) 6500 High Quality Design Aluminium Extruded With Decortive And Caps Fixed As Per Manufacturers Instructions And Making Necessary Electrical Connections And Testing On Completion Complete All As Directed. Make: Jaquar Cat No. Lglz01x010xc 10 W Cct 6500 Or Equivalent Ofbajaj / Crompton / Philips / Wipro / Havells. 36 S&F Sheet Metal Enclosures For DbS Double Door In Wall / Nitch When McbS To Be Used Triple Pole And Neutral, 4 Way, 415 Volt With 200 Amps Rated Bus Bar Complete All As Specified And Directed. 37 S&F Sheet Metal Enclouser For DbS In Wall / Nitch When McbS To Be Used Single Pole And Neutral, 2 Way, Single Door 240 Volt Complete All As Specified And Directed. 38 S&F Mcb Tpn 40 To 63 Amp, 240 V, 50 Hz, Ac Supply. Make: Legrand Cat No. 4086 81 To 4086 83 Or Equivalent Of Havells / L&T / Abb 39 S&F Mcb Spn 10 To 32 Amp 240 V 50 Hz Ac Supply, 10 Ka.Make: Legrand Cat No. 4086 12 To 4086 17 Or Equivalent Ofhavells / L&T / Abb 40 S&F Mcb Sp 240 V, 50 Hz, 10 Ka, Suitable For Lightning And Other Domestic Load Rating 6 To 20 Amp. Make: Legrand Cat No. 4085 87To 4085 93 Or Equivalent Ofhavells / L&T / Abb 41 Supply, Laying, Testing, Xlpe Insulated Screened, Pvc Innersheathed Galvanised Steel Strip Or Wire, Armoured, Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade, Cross-Sectional Area 10 Sqmm, 4 Core Including Suitable Lungs And Glands Complete All As Specified. 42 S&F 32 Mm Bore High Density Polyethylene Pipes Isi Marked ( Hdpe ) Of Pressure Rating 6 Kgf / Cm2 For Protection Of Cable In Trenches Complete As Specified. 43 Excavation In Trenches Not Exceeding1.5 M Wide And Not Exceeding 1.5 M In Depth For Foundation, Laying Of Pipe Line Etc And Getting Out In Any Type Of Soil ( I.E. Soft / Loose Or Hard Dense Soil ) Complete All As Specified And As Directed. 44 Returning Filling In Trenches Including Spreading, Leveling, Watering And Well Ramming In Layers Not Exceeding 25 Cm Thick In Soil Complete All As Specified And As Directed. 45 Removing Excavated Surplus Soil To A Distance Not Exceeding 50 Mtsand Depositing Where Directed At A Level Not Exceeding 1.5 M Above The Starting Point Complete All As Directed. 46 S&F Steel Conduit Cable Weather Proof Of Size 3 Core 4 Sqmm Pvc Insulated Unsheathed Multistanded Copper Conductor In Steel Conduit 25Mm From Junction Box To Fittings Complete All As Directed By Eic. Make: Havells / Finolex / Polycab 47 S&F 25Mm Ridgid Steel Conduit, Welded. 48 S&F Aviation Onstruction Led Light Single Emitter, Abs Red Cover, Cast Aluminium ( Lm-6 ) Housing Weather Proof Ip-65, Painted With Corrosion Resistant Yellow Paint Covered By Hard Abs Red Cover Dome & Sealed With Gasket, Long Life & Energy Saving Led Baed Lamp, Solid State, Ultra Red Led, Powe: 60W, Input Voltage: 150-300 Vac, Suitable For Low Lumens Intensity Applications Including Suitable Clamp, Nut Bolts And Connecting Materials Complete All As Specified And As Directed By Engineer-In-Charge. Make: Kalin / Wipro / Philips / Bajaj / Havells 49 Supply And Lay In Trenches / Fixed On Wall / Pole 32Mm Bore Gi Tubing Medium Grade With Necessary Fittings Such As Bend, Tee, Elbow Etc. Including Clamps, Nut Bolt And Other Materials As Required At Site. ( Note : Excavation And Earth Work Mewasured And Paid Seperately ) . 50 M&L For Earthing Complete With Galvanised Steel Earth Plate Electrode 60 Cm X 60 Cm X 3.15 Mm Thick, Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Metres Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Metres Below Normal Ground Level, Connected To 20 X 3Mm Copper Strip As Earth Lead By Mean Of Bolts, Nuts, Check Nuts And Washers Of Brass All As Shown In Electrical Plate No. 3 Connected Or Indicated Including Testing On Completion Including Necessary Excavation, Earth Work, Pcc Pit, Rcc Cover Reinforced With 8 Mm Tmt Bars Both Ways, Funnel With Watering Pipe 20Mm Bore Medium Grade, Gi Protection Pipe 40Mm Bore Medium Grade Complete All As Specified And As Directed. 51 S&F Copper Strip 20Mm X 3.15Mm Complete With Saddles And Fixing Screws For Fitting The Strip Complete. 52 S&F Aluminium Strip 25 X 3.15Mm With Saddles And Fixing Screws For Fitting The Strip Complete. 53 M&L For Air Termination, Single Pointed Aluminium Rod 12Mm Dia And 300Mm Long 54 S&F Test Point Terminal Block Made Of Gun Metal Or Phosphorus Bronze Size 75X75x25mm Drilled And Screwed Including 3 Nos. 8Mm Dia 25Mm Long Hex. Head Screw Complete.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-12-2022
2 26-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 31-12-2022
3 31-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 91900.0 /-
Tender Value
INR 45.95 Lakhs /-

BOQ Items

Name of Work:PROVN OF MAST AT QUARTER DECK AT INS VALSURA, JAMNAGAR
Sl. No. Item Description
1Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etc and removal of entire debris as ordered outside MD land complete all as directed.
2Demolition of cement concrete (un-reinforced) in ground floor and paving not exceeding 15 cm thick above or below ground level and removal of entire debris as ordered outside MD land complete all as directed.
3Dismantling floor, hearth or wall tiling inluding cement mortar bedding (but not backing), stackingserviceable tiles at site andremoval of entire debris as ordered outside MD land complete all as directed.
4Excavation in over areas not exceeding 1.5m deep and getting out in soft/ loose soil complete all as directed.
5Excavation in over areas not exceeding 1.5m deep and getting out in soft/ disintergrated rock complete all as directed.
6Excavation in over areas exceeding 1.5m and not exceeding 3.0m deep and getting out in soft/ disintergrated rock complete all as directed.
7Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
8Removing excavated surplus soil to a distance exceeding 1.5 km but not exc 5 km and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.
9M&L for PCC1:4:8, type D2 (using 40 mm graded crushed stone aggregate) as in foundation filling, mass concrete complete all as specified and directed
10M&L factory made pre cast PCC 1:3:6, type C1 (using 20 mm graded granite aggregate) as in block masonry with solid blocks, exceeding 10 cm in width and setting in CM 1:6 complete all as specified.
11M&L RCC M-30 (using 20 mm graded granite stone aggregate) as in foundation, including rafts, footings, foundation beams, plinthbeams, base of columns etc and the like complete. Note: Reinforcement shall be measured and paid separately.
12Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or batter, flat fair finished surface all as specified.
13S&F Hot dipped galvanised ( 80 microns as per IS 4759 ) structural steel tapered pipe (500mm dia at bottom and 300mm dia at top with 16mm thick throughout) of 30m high from base plate as in aerial masts and cross arms at various heights using tappered pipe as directed including gusset plates, stiffner, channels, square cut or notched, forming holes with revetted, bolted or welded attachement confirming to conforming to Fe-410W (Gde-E-250) quality "B" complete all as specified and as directed.
14S&F factory Hot dipped galvanised ( 80 microns as per IS 4759 ) Mild steel work in framed work such as grills, Framed guard bars, gratings, ladders etc., with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work.
15S&F factory Rolled Hot dipped galvanised (80 microns as per IS 4759) Mild Steel Plates (plain or Chequered) channels, square cut or notched (ordinary and counter sunk), forming holes, with riveted, bolted or welded attachment confirming to Fe 410-W (Gde-E-250).(Note for itemNo 14 & 15: (i) The work tobe executed in height more than10 Mtrs from ground level . (ii) NecessaryScafloding as per relevant safetyIS norms shall be followed & the same tobe got approved be Engineer-in-charge before commencementwork. (ii) . All tradesman involved in the taskshould pocesses validinsurance &the same tobe submitted to Engineer-in-charge for verification & record. (iii) All necessary saftey precautionery equipments as per IS such as hand gloves , safety belt , head helmentetc shall be arranged by the contractor without any extra cost to Govt (iv) The quoted rate aganist the said items in BOQ is deemed to be inclusive of the same & no extra shall be admissible. Contractor must visit the site prior quoting his bid to have a better assessement.
16S&F factory Hot dipped galvanised (80 microns as per IS 4759) Mild Steel Anchor bolts, straining bolts of any dia incl nuts and washers complete. (Note for item Nos. 15 & 16: Work shall be carried out on height more than 10 meter)
17S&F galvanised structural mild steel ropes of 15mm dia and fixed as directed.
18S&F galvanised structural mild steel ropes of 10mm dia and fixed as directed.
19S&F Stainless Steel pulleys (grade 316 SS) to accommodate 10mm dia rope for hosting flags, etc complete all as specified and as directed.
20S&F 10mm dia and over CRS TMT bars, cut to length bent to shape required cranking including bending, hooking ends etc and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
21All as per item No. 20 here- in – above but5 mm diaand over upto 10 mm dia as in stirrups
22S&F Stainless Steel Pipe for posts and struts (grade 316 SS with medium weight sections) comprising any dia SS pipe welded, buffed incl hooks for tying rope, etc made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size complete all as specified and as directed. complete all as specified and as directed.
23S&F Brass plaates of any thickness including welding complete all as specified and as directed.
24M&L for 100mm thick PCC 1:4:8, type D2 (using 40 mm graded crushed granite stone aggregate) as in sub base, floors, pavings etc. finished fair and even complete all as specified.
25M&L 20 mm thick granite slab (of any type) work (table rubbed, polished and rounding of edges where ever necessary as ordered) bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone laid over and including 15mm thick screed bed in cement mortar 1:6 complete all directed and specified.
26All same as per item No. 25 here-in-above but as in dado & skirting with 10mm thick 1:4 cement mortar screed - do - (Note for item No 25 & 26: i) Quoted rate is deemed to be inclusive of cement screed/ plaster.)
27M&L for point wiring with 1100 V, 1.5 Sqmm single core PVC FRLS insulated unsheathed cable, copper conductor multistranded passing through including PVC concealed conduit 20mm, concealed MS box/ PVC/ MS/ Cast Iron box and logic modular whtie plates of suitable as required at site with PVC insulated unsheathed stranded copper of size 1.5 sqmm earth copper cable, for one light point, bell point, fan point controlled by one switch including cutting and making good surface of walls applying suitable painting as required all as directed.
28All as per item No. 27 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in same board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as directed.
29All as per item No.27 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in independent board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
30All as per item No. 27 here-in-above, but size of cable 2.5 Sq.mm for 16 Amp and 6 Amp (3 pin) combined, modular switch socket in independent board with earth wire 2.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
31S&F Modular switch 1 way 6 Amps,1 module all as specified and direced.
32S&F Modular switch 1 way 16 Amps,1 module all as specified and direced.
33S&F Modular Socket 6A -2/3 pin combined 2 Module all as specified and directed.
34S&F Modular Socket 16A -2/3 pin combined 2 Module all as specified and directed.
35S&F 10 Watt wall mounted 2 ft glaze LED batten CCT(K) 6500 high quality design aluminium extruded with decortive and caps fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar Cat No. LGLZ01X010XC 10 W CCT 6500 or equivalent ofBajaj/ Crompton/ Philips/ Wipro/ Havells.
36S&F sheet metal enclosures for DB"s double door in wall/ nitch when MCB"s to be used Triple pole and neutral, 4 way, 415 Volt with 200 Amps rated Bus bar complete all as specified and directed.
37S&F sheet metal enclouser for DB"S in wall/ Nitch when MCB"s to be used Single pole and neutral, 2 way, Single door 240 Volt complete all as specified and directed.
38S&F MCB TPN 40 to 63 Amp, 240 V, 50 Hz, AC supply. Make: Legrand Cat No. 4086 81 to 4086 83 or equivalent of Havells/ L&T/ ABB
39S&F MCB SPN 10 to 32 Amp 240 V 50 Hz AC supply, 10 kA.Make: Legrand Cat No. 4086 12 to 4086 17 or equivalent ofHavells / L&T / ABB
40S&F MCB SP 240 V, 50 HZ, 10 KA, suitable for lightning and other domestic load Rating 6 to 20 Amp. Make: Legrand Cat No. 4085 87to 4085 93 or equivalent ofHavells / L&T / ABB
41Supply, laying, testing, XLPE insulated screened, PVC innersheathed galvanised steel strip or wire, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm, 4 Core including suitable lungs and glands complete all as specified.
42S&F 32 mm bore high density polyethylene pipes ISI Marked (HDPE) of pressure rating 6 kgf/cm2 for protection of cable in trenches complete as specified.
43Excavation in trenches not exceeding1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of pipe line etc and getting out in any type of soil (i.e. soft/ loose or hard dense soil) complete all as specified and as directed.
44Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and as directed.
45Removing excavated surplus soil to a distance not exceeding 50 mtsand depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.
46S&F steel conduit cable weather proof of size 3 core 4 Sqmm PVC insulated unsheathed multistanded copper conductor in steel conduit 25mm from junction box to fittings complete all as directed by EIC. Make: Havells/ Finolex/ Polycab
47S&F 25mm ridgid steel conduit, welded.
48S&F Aviation onstruction LED light single Emitter, ABS Red cover, cast aluminium (LM-6) housing weather proof IP-65, Painted with corrosion resistant yellow paint covered by hard ABS red cover dome & sealed with gasket, long life & energy saving LED baed lamp, solid state, ultra Red LED, powe: 60W, input voltage: 150-300 Vac, suitable for low lumens intensity applications including suitable clamp, nut bolts and connecting materials complete all as specified and as directed by Engineer-in-Charge. Make: Kalin/ Wipro/ Philips/ Bajaj/ Havells
49Supply and lay in trenches/ fixed on wall/ pole 32mm bore GI tubing medium grade with necessary fittings such as bend, tee, elbow etc. including clamps, nut bolt and other materials as required at site. (Note : Excavation and earth work mewasured and paid seperately ).
50M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 20 x 3mm copper strip as earth lead by mean of bolts, nuts, check nuts and washers of brass all as shown in electrical plate No. 3 connected or indicated including testing on completion including necessary excavation, earth work, PCC pit, RCC cover Reinforced with 8 mm TMT bars both ways, funnel with watering pipe 20mm bore medium grade, GI protection pipe 40mm bore medium grade complete all as specified and as directed.
51S&F copper strip 20mm x 3.15mm complete with saddles and fixing screws for fitting the strip complete.
52S&F aluminium strip 25 x 3.15mm with saddles and fixing screws for fitting the strip complete.
53M&L for air termination, single pointed aluminium rod 12mm dia and 300mm long
54S&F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex. head screw complete.
Disclaimer :