Tender For Supply, Delivery, Installation, Commissioning & Trial Run Of Electro-Mechanical Components At T/W No. I & Ii And Making Compound Lighting Arrangement At T/W No. I Of Dhansol & Adjoining Moujas Piped Water Supply Scheme In The District Of Jhargr, jhargram-West Bengal

Public Health Engineering Department-PHED has published Tender For Supply, Delivery, Installation, Commissioning & Trial Run Of Electro-Mechanical Components At T/W No. I & Ii And Making Compound Lighting Arrangement At T/W No. I Of Dhansol & Adjoining Moujas Piped Water Supply Scheme In The District Of Jhargr. Submission Date for this Tender is 28-12-2022. Coats and Jackets Tenders in jhargram West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

35275154
Tender For Supply, Delivery, Installation, Commissioning & Trial Run Of Electro-Mechanical Components At T/W No. I & Ii And Making Compound Lighting Arrangement At T/W No. I Of Dhansol & Adjoining Moujas Piped Water Supply Scheme In The District Of Jhargr
Open Tender
Indian
West Bengal
jhargram
28-12-2022

Tender Details

Supply, Delivery, Installation, Commissioning & Trial Run Of Electro-Mechanical Components At T / W No. I & Ii And Making Compound Lighting Arrangement At T / W No. I Of Dhansol & Adjoining Moujas Piped Water Supply Scheme In The District Of Jhargram Under Jhargram Mechanical Division, Phe. Dte. -Supply And Delivery Of Following Materials At Site:-Submersible Pumping Machinery Directly Coupled With Submersible Motor At 415 V ( ± 10% ) , 50 ( ± 3% ) Hz.Material Of Construction :Pump Bowl Housing : C.I.Pump / Motor Shaft : Ss-410.Impeller : Bronze / Cs / Ssnrv Size : 65 / 80 / 100 Mmstarting Method : S / D ( Star-Delta ) Starter. Speed : 2900 Rpm Max.These Item Will Be Procured Based On Yeild Test Report Of T / Wells And Best Efficiency Point As Per Direction Of Eic. ( Test Certificates, Material Of Construction And H & Q Characterstic Curve Should Be Provided At The Time Of Delivery ) Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments.For T / W No. Idischarge ( Q ) - 22 M3 / Hrand Head ( H ) - 60 Mtr. 2 For T / W No. Iidischarge ( Q ) - 22 M3 / Hrand Head ( H ) - 60 Mtr. 3 80 Mm Dia Upvc ( Standard Type ) Column Pipe With Both Side Threaded And One Side Socketed ( For T / W No. I & Ii ) A ) 3 Mtr. Long 4 B ) 1.5 Mtr Long 5 C ) Top Adoptor ( Ci ) 6 D ) Bottom Adoptor ( C.I ) 7 M.S Fabricated Split Type Suitable Tube Well Cover As Per Tube Well Housingwith Necessery Clamping Arrangement Including Holes With Column Pipe, Air Pipe And Cable Entry Etc. ( For T / W No. I & Ii ) 8 102 Mm. Dia 0-10 Kg / Cm² Range Wall Mounted Bourden Type Pressure Gauge Complete For Tubewell Outside The Pump House Including Brass Cock & Fittings.Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. ( For T / W No. I & Ii ) 9 102 Mm. Dia. Wall Mountedbourden Type Depth Gauge With Suitable Dia. And Length Of Steel Air Pipe With All Fittings Including Supply Of One Good Quality Hand Pump For Tubewell Outside The Pump House. ( This Cost Includes 15 Mm. Dia. G.I. Pipe Approx. 90 Ft. Length And Specials ) Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. ( For T / W No. I & Ii ) 10 Anti-Snapping Safety Device For Above Pump By Supplying 1 Dia. Nylone Rope Of Required Length ( Double ) Including Supply Of All Necessary Materials As Required. ( For T / W No. I & Ii ) 11 M.S Suspention Clamp With Necessery Nuts, Bolts & Washers Etc. Suitablefor 80 Mm Dia Pipe ( Size 500 Mm X 80 Mm X 8 Mm Each ) ( For T / W No. I & Ii ) 12 80 Mm Dia, P.N. 1.0, Cidf Non Return Valve Conforming To Is: 5312, Part-I. Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. ( For T / W No. I & Ii ) 13 80 Mm Dia, Pn-1.0, Cidf Sluice Valve Conforming To Is:14846. Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. ( For T / W No. I & Ii ) 14 80 Mm Dia, ( Pn-1.0 ) Cidf, Wafer Type Butterfly Valve Operated By Three Phase Actuator Conforming To Is:13095 / 1991, Ip 68.Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. ( For T / W No. I & Ii ) 15 80 Mm Dia Heavy Type Suitable Length Ci / Ms Black Pipes ( For Delivery Header & Backwash Line For Pumps Under Sl No.- 1, Along With Necessary Bends, Tees, Specials, Fittings , Viz Flanges, Bolts, Nuts, Gaskets, Concentric Enlarger , Ms Dismentling Joint, For Erecting Main Discharge Pipeline Etc. Including Providing Ms / Bricks / Pcc Support For Laying Of Pipes, Valves As Required To Make The Installation Complete As Per Satisfaction Of E.I.C. ( This Includes The Cost Of Supply, Delivery Of Header & Short Piece Of Required Length To Erect The Delivery & Backwash Pipe Lines ) ( For T / W No. I & Ii ) 16 1.1 Kv Grade, 2.5 Sq.Mm. 3 Core Pvc Insulated & Sheathed Copper Flat Submersible Cable As Per Is-694, Part-I With Latest Amendments.Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. ( For T / W No. I & Ii ) 17 1.1 Kv Grade 415 V, 4 Core 16 Sq.Mm. Pvc Sheathed Xlpe Insulated Al. Armoured Cable Conforming To Is:7098 ( Part-1 ) 2011 With Latest Amendmends As Applicable.Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. ( For T / W No. I & Ii ) 18 1.1 Kv Grade, 12 Core, 1.5 Sq. Mm. Copper Control Cables, Solid Copper Conductor & Balance Stranded Copper, Xlpe Insulated Pvc Inner Sheathed, Armoured Extruded Pvc Type St2 Sheathed As Per Is 7098 ( Part 1 ) 1988. ( For Actuator Connection From Mcc Panel ) Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. ( For T / W No. I & Ii ) 19 415 V, Three Phase Plc Panel With Minimum 2 Mm Thick Crca Sheet, Degree Of Protection Ip-54, Conforming To Is - 8623 With Suitable Size Bus Bar, Digital Voltmeter, Digital Ammeter, Contactor, Delay Timer, Mcb, Valve Actuator Starter Etc. With Plc Logic & Ups .I ) 7.5 - 12.5 Hp With Sd ( Star-Delta ) Starter. ( Drawing & Bill Of Materials Shall Be Approved By E.I.C ) Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. Spec : As Per Specification Attached. ( For T / W No. I & Ii ) 20 15 Kva, 3 Phase Oil Cooling Type Servo Motor Operated Copper Wound Linevoltage Stabilizer, Having Unbalanced 200 - 500 V Input Voltage, And 415 ( ± 1% ) Output Voltage , Auto / Manual Servo Voltage Stabilizer With U / V, O / V, O / L Protection With Mcb At Output Side, Mccb At Input Side, Ammeter Etc. As Per I.E Rules And As Per Instruction Of Eic. Stabilizer Capacity Shall Be Selected Based On Selected Pump Capacity. Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. ( For T / W No. I & Ii ) 21 Automatic Plunger Type Chlorinator For Feeding Accurately Controlled Dosage Of Chlorine Solution Into The Water By Connecting Metering Pump With Flow Rate Of Water 0 -100 Lph With Maximum Pressure Of 10 Kg / Cm2 Suitable Dosing Pump & Other Accessories On The Delivery Pipe Line As Required, The Pump Shall Be Coupledwith 0.5 Hp Motor Having Three Phase Power And 1440 Rpm ( ± 4% ) . ( Motor Make- Cgl / Kec / Abb / Any Approved Make ) Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. ( For T / W No. I & Ii ) 22 Hard Wooden Board ( 450 Mm X 304.8 Mmx 25 Mm Thick ) ( For T / W No. I & Ii ) 23 63 Amp, 240 / 415 V Porcelain Fuse Unit ( Base & Bridge ) Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. ( For T / W No. I & Ii ) 24 63 Amps, 415 V, Ictpn ( Iron Claded Triple Pole Neutral ) Main Switch In Sheet Steel Enclosure Having Rewireable Type Fuse Grip.Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. ( For T / W No. I & Ii ) 25 63 Amps, 415 V Bus-Bar Chamber Having 4 Nos. Aluminium Bar. Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. ( For T / W No. I & Ii ) 26 63 Amp, 4 Pole On Load Change Over Switch. Make: Havells ( Category Code. Ihbffe0063 ) / Any Other Equivalent Approved Make. ( For T / W No. I & Ii ) 27 6-32 Amp, 10 Ka, 240 / 415V, 50 Hz Sp Mcb Conforming To Is / Iec: 60898-1, C Characteristics. ( 10 Amp - 1 No., 16 Amp -1 No. ) Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. ( For T / W No. I ) 28 8 Way Sp&N Double Door Horizontal Distribution Board ( I / C 2 + O / C 6 ) Conforming To Is 13032 & Is 8623 And Ip42 / 43. Make :- Legrand ( Model No. 5076 11 ) ( For T / W No. I ) 29 Led Street Light Luminarie Ip 66 Lm6-Hpdc Housing Street Light Aerodynamically Designed With Better Thermal Management / Potted Driver Is To Be Provided, The Luminaire & Housing Should Be From The Same Manufacturer ( Cat No.- Brp052 Led 045 Cw Slmr Fg S1 Psu Gr / Equivalent, System Efficacy Greater Than 100 Lumen / Watt ) Make - Philips / Equivalent And Same Technical Specification Of Havells. The Manufacturer Has To Provide Lm79 / Lm80 Reports Corresponding To The Luminaire / Led Chip Respectively Along With Type Test Certificate. The Luminaire Manufacturer Should Have An In House Nabl Accredited Testing Facility. ( For T / W No. I & Ii ) 30 Pvc Mouldedchair Without Arm. ( Make:- Nilkamal / Supreme / Cello ) ( For T / W No. I & Ii ) 31 Pvc Moulded Table Of 850 X 850X 725 Mm Size. ( Make:- Nilkamal / Supreme / Cello ) ( For T / W No. I & Ii ) 32 Installation Of The Above Supplied Item:-Installation, Testing & Commisioning Of Above Supplied Pumping Machinery, Mcc, Valves Etc. ( Item No 1 To 15, 18 To 20, 22 To 28 ) By Jointing Submersible Cable Within The Tubewell Situated Outside The Pump House By Making Derrick Arrangement By Assembling The Column Pipes Properly And Fitting, Fixing The Pressure Gauge, Depth Gauge, Air Pipe Etc. In Position And Erection Of Delivery Line & Backwash Line With The C.I Specials And Tee Including Mending Damages Goods Etc.All Complete As Per Direction. This Also Includes The Charges For Laying Submersible Cable, Copper Control Cable From Tubewell To Control Panel By Underground Trench And Saddle On Wall As Required And Connection With Required Feeders Of Panel All Complete. ( For T / W No. I & Ii ) 33 Supply And Installation Of 2 Mm Thick, Powder Coated Anticorrosive Painted G.I.Fabricated Outdoor Mounted Canopy Type Cable Jointing Box Having Four Legs And Six Nos. 100 Amps Al Bus Bar, Hinge Type Front Having Ip 55 Protection &Locking Arrangement As Per Direction Of E I C . ( For T / W No. I & Ii ) 34 Making Suitable Size Pump Foundation Base ( Size: 1.00 Mtr. X 1.00 Mtr. X 1.5 Mtr. ) With Supplying Cement, Sand, Stone Chips Etc. In The Portion Of ( 4:2:1 ) Including Plastering, Neat Cement Finishing Including Painting Etc. All Complete As Per Direction Of Eic. ( I ) Tubewell Outside Pump House ( For T / W No. I & Ii ) 35 Making Required Nos. Of Brick Pillar 0.25 Mtr. X 0.25 Mtr. For Supporting Of Valves, Actuator And Pipes With 12 Mm Thick Plaster And Net Cement Finish Including Painting All Complete As Per Direction Of E.I.C ( For T / W No. I & Ii ) 36 Installation & Commissioning Of Above Chlorinator With Supplying & Drawing Of Suitable Length 1.1 Kv Grade 3 X 36 / 0.3 ( 2.5 Sqmm ) Single Core Stranded FrlshPvc Insulated & Unsheathed Copper Wire ( Approved Make ) From Suitable Feeder Of Installed Panel Board Through 20 Mm Size Pvc Rigid Conduit Fr ( Precision Make ) Incl. Necy. Fittings As Required And Continuous Earthingfrom Nearest Earth Grid. This Includes The Cost Of Making Required Height Brick Foundation Base With Neat Cement Finishing By Supplying All Required Materials And Testing The Entire Set Asper Direction Of Eic. ( Height Of Tank Foundation Shall Be Higher Than That Of Chlorine Machine. In Case Of Installation Of Iron Elimination Plant ( Iep ) At Head Work Site, The Suction And Delivery Pipeline For Chlorination Shall Be Drawn From Suitable Position At The Discharge Pipeline Of Iep. No Chlorine Machine Shall Be Installed At P / H No. Ii In Case Of Iep And The Same Will Be Installed At P / H No. I As Standby ) . ( For T / W No. I & Ii ) 37 S & F Of 3 Dia 1.5 Mt Minipole With Baseplate To Be Fixed On Roof Top Incl. S&F Of 1.5 Mtr Long Arm Bracket ( Removable Type ) Incl. Cc ( 6:3:1 ) Muffing ( 450 X 450 X 600 ) With 3 Mm Thick Neat Cement Finish & Painting Incl. S&F Of 200 X 150 X 100 Mm 16 Swg Gi Loop Box With Necessary Power Connection By3x 22 / 0.3 ( 1.5 Sq.Mm ) ( 2 Nos. P & N And 1 No. Ecc ) Frlsh Pvc Insulated & Unsheathed Copper Wire ( Approved Make ) In 20 Mm Size Pvc Rigid Conduit Fr ( Precision Make ) Incl. Necy. Fittings As Required As Per Direction Of Eic. ( For 12M Length @ 102 / Mtr. ) ( For T / W No. I & Ii ) 38 Laying Of Cable ( As In Item No. 17 ) On Wall / Surface Incl. S & F Of Ms Saddles With Earthing Attachment In 10 Swg Gi ( Hot Dip ) Wire, Making Holes Etc. As Necy. Mending Good Damages And Painting All Complete As Per Direction Of E.I.C. 39 Supplying And Fixing Of Compression Type Gland Complete With Brass Gland, Brass Ring & Rubber Ring For Dust & Moisture-Proof Entry Ofcable ( As In Item No. 17 ) All Complete As Per Direction Of E.I.C. 40 Finishing The End Of Cable ( As In Item No. 17 ) By Crimping Method Incl. Supplying And Fixing Solderless Socket ( Dowels Make ) , Tapes, Anticorrosive Paste & Jointing Materialsall Complete As Per Direction Of E.I.C. 41 Making Internal Wiring / Electrification Of The Pump House By ( 2X 22 / 0.3 ( 1.5 Sqmm ) + 1X 22 / 0.3 ( 1.5 Sqmm ) Single Core Pvc Insulated Multistrand Frlsh Grade Flexible Copper Wire Through 20 Mm Pvc Conduit Pipe / Casing By Supplying One No. 40 Amp, 10Ka, 240 / 415V, 50 Hzspn / Dp Mcb Isolator Conforming To Is / Iec: 60947-3, C Characteristics. ( As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments ) With Required Module Pvc Board & Piano Key Type Switch. ( Ave. Run 6 Mtr ) . I ) Led Tube Set Point - 2 Nos., Bulk Head Light Point- 1 No., 5 Pin 6 Amps. Plug Point- 1 No., 16 Amp Socket & Switch- 1 No, With Necy. Earthing Arrangement & One Fan Point ( Total Point 6 Nos. Points ) Including Drawing Power By Suitable Gauge ( 2.5 Mm2 ) Of Copper Wire From Installed Pdb Panel To Switch Board Through Db For P / H No. I & From Panel To Switch Board For P / H No. Ii Through 20 Mm Pvc Casing Capping ( Precision Make, Lms ) As Per Direction Of Eic ( Fittings Should Be Of Philips Make & Wiring Should Be With Continuous Earthing Arrangement And 20W Two Nos. 4 Ft Long Led Tube Light Setsphilips / Astra Line / Other Equivalent Make, One No. Bulk Head, One No. 0-4 Step Fan Regulator ( Humfree ) , Fittings Etc To Be Supplied By Agency ) . ( For T / W No. I & Ii ) 42 ( A ) Earthing With 50 Mm Diameter G.I. Pipe 3.64 Mm Thick X 3Mtr. ( 10Ft. ) Long And 1 X 4 Swg G.I. Wire ( 4Mtr.Long ) 13 Mm Diameter X 80Mm ( 3Inch ) Long G.I. Bolts, Double Nuts, Washer Including S & F Of 15Mm Diameter G.I. Pipe Protection ( 1 Mtr. Long ) To Be Filled With Bitumen Partly Below Ground Level To An Average Depth Of 3.65Mtr. ( 12Ft. ) Below The Ground Level And Restoring The Surface Duly Rammed.I ) For Soft Soil By Isi Medium Gi Pipe. ( For T / W No. I & Ii ) 43 ( B ) Extra For Providing Masonery Enclosure On The Top Of The Earth Electrode Of Overall Size 86.36 Cm X 86.36 Cm X 46 Cm Deep ( Below Ground Level ) Complete With Cemented Brick Work ( 1:6 ) Of 25 Cm Width Duly Plastered With Cement Morter ( Inside ) Ci Hinged Inspection Cover Of Size 36.56 Cm X 35.56 Cm With Locking Arrangement, Gi Reducer Including Drilling Of 46 Nos. 12 Mm Diaholes On The Gi Pipe. ( For T / W No. I & Ii ) 44 ( C ) Extra For Treatment Of Soil By Salt And Charcoal Coke For Pipe Electrode. ( For T / W No. I & Ii ) 45 ( D ) Supplying & Fixing Earth Busbar Of Galvanized ( Hot Dip ) Ms Flat 25 Mm X 6 Mm On Wall Having Clearance Of 6 Mm From Wall Including Providing Drilled Holes On The Busbar Complete With Gi Bolts, Nuts, Washers, Spacing Insulators Etc. As Required.Length Of Busbar Is 0.5 Mtr. ( For T / W No. I & Ii ) 46 ( E ) Connecting The Equipments Body To Earth Busbar Including S&F 20 Mm X 6 Mm Galvanised ( Hot Dip ) Ms Flat On Wall / Floor With Gi Saddles As Required And Connection To Equipments Incl. Drilling Holes, With Bolts, Nuts, Washers Etc. ( For T / W No. I & Ii ) 47 Supply, Delivery And Fitting-Fixing Of 230 Volt1200 Mm Sweep Ac Ceiling Fan Withball Bearing Complete With All Accessories Such As Blade, Canopy, Fork, Down Rod Etc. Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. ( For T / W No. I & Ii ) 48 Trial Operation And Guarding Of The Installed Pumping Machinary After Receiving Power And Commisioning The Pumping Machinary As Per Direction Of E.I.C I ) For T / W No. I ( For 90 Days ) 49 Ii ) For T / W No. Ii ( For 90 Days ) 50 Making Compound Lighting Arrangement And Allied Works For Head Work Site I.E. T / W No. I9 Mtr. Long Swaged Steel Tabular Pole ( Designation- 410 Sp-26 ) ( Over All Length- 9.00 Mtr, Planting Depth- 1.5 Mtr ) , Length Of Section, Bottom-5.0Mtr, Middle- 2.0 Mtr, Top- 2.0Mtr, ) Outside Dia & Thickness Of Section ( Bottom-114.3X4.50Mm, Middle-88.9X4.05Mm, Top-76.1X3.25 ) Approx Weight Of Pole - 92Kg. Including Supply And Fixing Of C.I. Base Plate, C.I Cap Etc.Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. 51 Single Arm Bracket Of 40 Mm Dia And 1.5 Mtr. Long.Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. 52 Street Light Luminaire Having Single Die Ceramic Base High Power Led Light Source, Ip66 Protection, Pdc Housing With Finless Design And Polycarbobate Cover ( Ik08 ) With Better Thermal Management / Potted Driver Is To Be Provided, The Luminaire And Housing Should Be From The Same Manufacturer ( Cat No- Brp062 Led 68 Cw Slc S1 Psu / Equivalent, Lumen O / P- 6800, System Efficacy Greater Than 100 Lumen / Watt ) Make-Philipsor Equivalent And Same Technical Specification Of Havells Or Other Apprioved Make As Per Direction Of Eic. The Manufacturer Has To Provide Lm79 / Lm80 Reports Corresponding To The Luminaire / Led Chip Respectively Along With Type Test Certificate. The Luminaire Manufacturer Should Have An In House Nabl Accredited Testing Facility. 53 Aesthetically Designed Post-Top Led Luminarie Having Die Cast Aluminium Housing With Ip66 Protection With Resistant To Impact And Corrosion. ( Make :- Havells ( Ruby Pt35wled757psymtopc, Coral ( Pt35wled757psymtopc ) / Other Approved Make ) . 54 1.1 Kv Grade 415 V, 2 Core 4 Sq.Mm. Pvc Sheathed Xlpe Insulated Al. Armoured Cable Conforming To Is:7098 ( Part-I ) 1988 With Latest Amendmends As Applicable.Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. 55 32 Mm Dia G.I. Pipe. ( Isi - Medium ) 56 Erection Of 9 Mtr Single Steel Tubular Pole With Sole Plate & Cap Etc. In Cc Foundation ( Size 0.6X0.6 X 1.7 Mtrs ) , Having 600X600x750 Mm Thick Cc ( 4:2:1 ) Base Block Below Sole Plate / Pole With Hard Jhama Metal Including Cc ( 6:3:1 ) Muffing 0.30 Mts. Dia And 0.30 Mts. Above Ground Level Including 3 Mm Thick Neat Cemented Finish And Gi Earth Bolt And Earthing Arrangement By 8 Swg Gi Wire, After Making Drilled Holes Etc. On Pole & Carriage Of Pole Upto 1.6 Km From Store To Worksite Including Filling Up The Excavated Earth Pit With Shifted Soil And Ramming Properly. 57 Extra On Item No. 58. Above, For Providing Cc ( 6:3:1 ) Base Block ( Around The Pole ) Dimension 0.45X0.45X0.60 Mt. Above Ground Level, Neatly Cemented Finish ( 3 Mm Thick ) , At The Base Pole ( In Lieu Of Cc Muffing ) Suitable For Alkathene / Polythene Pipe Entry As Directed For Streel Light Wiring Incl. S & F 20 Cmx15cmx10 Cm G.I. Loop Box, 16 Swg & Incl. Drilled Hole In Pole. 58 Supplying & Fixing Gi Waterproof Type Looping Cable Box Size 200X150x100 Mm Deep Having 4 Mm Thick Comprising Of One 250 V 15 A Kit-Kat Fuse Unit, One Nl On Porcelain Insulator, One Compression Type Brass Cable Gland For Upto 2- Core 16 Sqmm Pvc / A Cable And Having Lined With Rubber Gasketted Gi Top Cover With Brass Machine Screws Etc., Earthing Terminal With Lug, On Steel Tubular Pole Near Base, Including S&F 40X6 Mm Thick, Ms Clamps With Bolts, Nuts Etc. Including Painting With Anticorrosive Paint All Complete As Per Direction. 59 Fitting-Fixing Of The Above Supplied Street Luminaries ( As In Item No. 52 ) At Suitable Position On Wall / Pole By Using Fixing Materials Including Making Interconnection By Using The Cu Wire With Making Earthing Connection From Loop Box All Complete As Per Entire Satisfaction Of E.I.C. 60 Laying Only Cable As In Item No. 54 Through Existing Gi Pipe / Open Masonary Trench For 2 Core 4 Sq. Mm. 61 Laying Of Cable As In Item No. 54 On Wall / Surface Incl. S & F Ms Saddles With Earthing Attachment In 10 Swg Gi ( Hot Dip ) Wire, Making Holes Etc. As Necy. Mending Good Damages And Painting As Directed By Eic. ( Cable Shall Be Procured As Per Site Requirement ) 62 Laying Of Cable As In Item No. 54 In Underground Trench 460 Mm Wide X 760 Mm Average Depth, With Brick Protection Onthe Top Of The Cable With 8 ( Eight ) Nos. Bricks Per Metre, Including Filling The Space Between The Brick & Cable And Also The Trench With Shifted Soil, Leveling Up And Restoring Surface Duly Rammed All Complete As Per Direction Of E.I.C. 63 Supplying And Fixing Of Compression Type Gland Complete With Brass Gland, Brass Ring & Rubber Ring For Dust & Moisture-Proof Entry Of 1.1 Kv Gr. 2 Core 4 Sq.Mm Xlpe Armored Alu. Cable All Complete As Per Direction Of E.I.C. 64 Finishing The Cable As In Item No. 54 By Crimping Method Incl. Supplying And Fixing Solderless Socket ( Dowels Make ) , Tapes, Anticorrosive Paste & Jointing Materials All Complete As Per Direction Of E.I.C. 65 Pole Earthing By Supply And Installation Of Gi Pipe Electrode 50 Mm Dia.And 3.64 Mm Thick X 3.04 Mtr. Longincluding Suitable Gauge G.I. Wire And Other Necessary Materials As Per General Specification And Direction Of E.I.C. 66 Painting All The Single Arm & Double Arm G.I Brackets, Poles ( 9 Mtr. ) Etc. With 2 Coats Of Synthetic Enamel Paint Over 1 Coat Of Red Oxide Primer After Cleaning And Preparation Of Surface By Emery Paper All Complete As Per Direction. 67 Fitting Fixing Of Die Cast Aluminium Housing Of Gate Light As In Item No. 53 With Suitable G.I Net Protection As Per Direction Of E.I.C

Key Value

Document Fees
Refer document
EMD
INR 43928.0 /-
Tender Value
INR 21.96 Lakhs /-

BOQ Items

Name of Work: Supply, delivery, installation, commissioning & trial run of electro-mechanical components at T/W no. I & II and making compound lighting arrangement at T/W no. I of Dhansol & adjoining moujas piped water supply scheme in the district of Jhargram under Jhargram Mechanical Division, PHE. Dte.
Sl. No. Item Description
1Supply and delivery of following materials at site:- Submersible pumping machinery directly coupled with submersible motor at 415 V (± 10%), 50 (± 3%) Hz. Material of Construction : Pump Bowl Housing : C.I. Pump / Motor shaft : SS-410. Impeller : Bronze/CS/SS NRV Size : 65/80/100 mm Starting Method : S/D (Star-Delta) starter. Speed : 2900 rpm max. These item will be procured based on yeild test report of T/wells and best efficiency point as per direction of EIC. (Test certificates, Material of Construction and H & Q characterstic curve should be provided at the time of delivery) Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments. For T/W no. I Discharge(Q) - 22 m3/hrand Head (H) - 60 mtr.
2For T/W no. II Discharge (Q) - 22 m3/hrand Head (H) - 60 mtr.
380 mm dia UPVC (Standard type) Column pipe with both side threaded and one side socketed (For T/W no. I & II) a) 3 mtr. Long
4b) 1.5 mtr Long
5c) Top Adoptor (CI)
6d) Bottom Adoptor (C.I)
7M.S fabricated split type suitable tube well cover as per tube well housingwith necessery clamping arrangement including holes with column pipe, air pipe and cable entry etc. ( For T/W no. I & II)
8102 mm. dia 0-10 kg/cm² range wall mounted bourden type pressure gauge complete for tubewell outside the pump house including brass cock & fittings. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments. ( For T/W no. I & II)
9102 mm. dia. wall mountedbourden type depth gauge with suitable dia. and length of steel air pipe with all fittings including supply of one good quality Hand pump for tubewell outside the pump house. (This cost includes 15 mm. dia. G.I. pipe approx. 90 ft. length and specials) Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments. ( For T/W no. I & II)
10Anti-snapping safety device for above pump by supplying 1"" dia. Nylone rope of required length (double) including supply of all necessary materials as required. ( For T/W no. I & II)
11M.S suspention clamp with necessery nuts, bolts & washers etc. suitablefor 80 mm dia pipe ( Size 500 mm X 80 mm X 8 mm each) ( For T/W no. I & II)
1280 mm dia, P.N. 1.0, CIDF Non return valve conforming to IS: 5312, part-I. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments. ( For T/W no. I & II)
1380 mm dia, PN-1.0, CIDF sluice valve conforming to IS:14846. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments. ( For T/W no. I & II)
1480 mm dia, (PN-1.0) CIDF, wafer type butterfly valve operated by three phase actuator conforming to IS:13095/1991, IP 68. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments. ( For T/W no. I & II)
1580 mm dia heavy type suitable length CI/MS Black pipes (for delivery header & backwash line for pumps under sl no.- 1, along with necessary bends, tees, specials, fittings , viz flanges, bolts, nuts, gaskets, concentric enlarger , MS dismentling joint, for erecting main discharge pipeline etc. including providing MS/Bricks/PCC support for laying of pipes, valves as required to make the installation complete as per satisfaction of E.I.C. (This includes the cost of supply, delivery of header & short piece of required length to erect the delivery & backwash pipe lines) ( For T/W no. I & II)
161.1 KV grade, 2.5 sq.mm. 3 core PVC insulated & sheathed copper flat submersible cable as per IS-694, Part-I with latest amendments.Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments. ( For T/W no. I & II)
171.1 KV Grade 415 V, 4 core 16 sq.mm. PVC sheathed XLPE insulated Al. armoured cable conforming to IS:7098 (PART-1) 2011 with latest amendmends as applicable. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments. ( For T/W no. I & II)
181.1 KV grade, 12 core, 1.5 sq. mm. Copper Control Cables, Solid Copper Conductor & Balance Stranded Copper, XLPE Insulated PVC Inner sheathed, Armoured extruded PVC Type ST2 Sheathed as per IS 7098 (Part 1) 1988. (For actuator connection from MCC panel) Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments. ( For T/W no. I & II)
19415 V, Three phase PLC Panel with minimum 2 mm thick CRCA sheet, degree of protection IP-54, conforming to IS - 8623 with suitable size Bus bar, Digital Voltmeter, Digital Ammeter, Contactor, Delay timer, MCB, Valve Actuator starter etc. with PLC Logic & UPS .i) 7.5 - 12.5 HP with SD (Star-Delta) starter. (Drawing & Bill of materials shall be approved by E.I.C)Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments. SPEC : As per Specification attached. ( For T/W no. I & II)
2015 KVA, 3 phase oil cooling type servo motor operated copper wound lineVoltage Stabilizer, having unbalanced 200 - 500 V input voltage, and 415 (± 1%) output voltage , Auto/manual servo voltage stabilizer with U/V,O/V,O/L protection with MCB at output side, MCCB at input side, Ammeter etc. as per I.E rules and as per instruction of EIC. Stabilizer capacity shall be selected based on selected pump capacity. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments. ( For T/W no. I & II)
21Automatic plunger type chlorinator for feeding accurately controlled dosage of chlorine solution into the water by connecting metering pump with flow rate of water 0 -100 LPH with maximum pressure of 10 Kg/Cm2 suitable dosing pump & other accessories on the delivery pipe line as required, the pump shall be coupledwith 0.5 hp motor having three phase power and 1440 RPM (± 4%). (Motor Make- CGL/KEC/ABB/Any approved make) Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments. ( For T/W no. I & II)
22Hard wooden board (450 mm X 304.8 mmx 25 mm thick) ( For T/W no. I & II)
2363 Amp, 240/415 V Porcelain fuse unit (Base & Bridge) Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments. ( For T/W no. I & II)
2463 Amps, 415 V, ICTPN (Iron Claded Triple Pole Neutral) main switch in sheet steel enclosure having rewireable type fuse grip.Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments. ( For T/W no. I & II)
2563 Amps, 415 V Bus-Bar chamber having 4 nos. Aluminium Bar. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments. ( For T/W no. I & II)
2663 Amp, 4 pole on load change over switch. Make: Havells (category code. IHBFFE0063)/any other equivalent approved make. ( For T/W no. I & II)
276-32 Amp, 10 kA, 240/415V, 50 Hz SP MCB conforming to IS / IEC: 60898-1, "C" characteristics. (10 Amp - 1 no.,16 Amp -1 no.) Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments. ( For T/W no. I)
288 way SP&N Double Door horizontal Distribution Board (I/C 2 + O/C 6) conforming to IS 13032 & IS 8623 and IP42/43. Make :- Legrand (model no. 5076 11) ( For T/W no. I)
29LED street light luminarie IP 66 LM6-HPDC Housing Street light aerodynamically designed with better thermal management/ Potted driver is to be provided, the luminaire & housing should be from the same manufacturer (cat no.- BRP052 LED 045 CW SLMR FG S1 PSU GR/equivalent, System Efficacy greater than 100 lumen/watt) Make - Philips/equivalent and same technical specification of Havells. The manufacturer has to provide LM79/LM80 reports corresponding to the luminaire/LED Chip respectively along with type test Certificate. The luminaire manufacturer should have an in house NABL Accredited testing facility. ( For T/W no. I & II)
30PVC mouldedchair without arm. (Make:- Nilkamal/Supreme/Cello) ( For T/W no. I & II)
31PVC moulded table of 850 x 850x 725 mm size. (Make:- Nilkamal/Supreme/Cello) ( For T/W no. I & II)
32Installation of the above supplied item:- Installation, testing & commisioning of above supplied Pumping Machinery, MCC, valves etc. (item no 1 to 15, 18 to 20, 22 to 28) by jointing submersible cable within the tubewell situated outside the pump house by making derrick arrangement by assembling the column pipes properly and fitting, fixing the pressure gauge, depth gauge, air pipe etc. in position and erection of delivery line & Backwash line with the C.I specials and Tee including mending damages goods etc.all complete as per direction. This also includes the charges for laying submersible cable, copper control cable from tubewell to control panel by underground trench and saddle on wall as required and connection with required feeders of panel all complete. ( For T/W No. I & II)
33Supply and installation of 2 mm thick, powder coated anticorrosive painted G.I.Fabricated outdoor mounted canopy type Cable Jointing Box having four legs and six nos. 100 Amps Al Bus bar, hinge type front having IP 55 protection &locking arrangement as per direction of E I C . ( For T/W no. I & II)
34Making suitable size pump foundation base ( Size: 1.00 mtr. x 1.00 mtr. x 1.5 mtr.) with supplying cement, sand, stone chips etc. in the portion of (4:2:1) including plastering, neat cement finishing including painting etc. all Complete as per direction of EIC. (i) Tubewell outside pump house ( For T/W no. I & II)
35Making required nos. of brick pillar 0.25 mtr. X 0.25 mtr. For supporting of valves, actuator and pipes with 12 mm thick plaster and net cement finish including painting all complete as per direction of E.I.C ( For T/W no. I & II)
36Installation & commissioning of above chlorinator with supplying & drawing of suitable length 1.1 KV grade 3 x 36/0.3 (2.5 sqmm) single core stranded "FRLSH"PVC insulated & unsheathed copper wire (approved make) from suitable feeder of installed panel board through 20 mm size PVC rigid conduit "FR" (Precision make) incl. necy. fittings as required and continuous earthingfrom nearest earth grid. This includes the cost of making required height brick foundation base with neat cement finishing by supplying all required materials and testing the entire set asper direction of EIC. (Height of tank foundation shall be higher than that of chlorine machine. In case of installation of Iron Elimination Plant (IEP) at head work site, the suction and delivery pipeline for chlorination shall be drawn from suitable position at the discharge pipeline of IEP. No chlorine machine shall be installed at P/H no. II in case of IEP and the same will be installed at P/H no. I as standby). ( For T/W no. I & II)
37S & F of 3" dia 1.5 mt minipole with baseplate to be fixed on roof top incl. S&F of 1.5 mtr long arm bracket (removable type) incl. CC (6:3:1) muffing(450 x 450 x 600) with 3 mm thick neat cement finish & painting incl. S&F of 200 x 150 x 100 mm 16 SWG GI loop box with necessary power connection by3x 22/0.3 (1.5 Sq.mm) (2 nos. P & N and 1 no. ECC) "FRLSH" PVC insulated & unsheathed copper wire (Approved make) in 20 mm size PVC rigid conduit "FR" (Precision make) incl. necy. fittings as required as per direction of EIC. (for 12m length @ 102/mtr.) ( For T/W no. I & II)
38Laying of cable (as in item no. 17) on wall/surface incl. S & F of MS saddles with earthing attachment in 10 SWG GI (Hot Dip) wire, making holes etc. as necy. mending good damages and painting all complete as per direction of E.I.C.
39Supplying and fixing of compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry ofcable(as in item no. 17) all complete as per direction of E.I.C.
40Finishing the end of cable (as in item no. 17) by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materialsall complete as per direction of E.I.C.
41Making internal wiring/electrification of the Pump house by (2x 22/0.3 (1.5 sqmm) + 1x 22/0.3 (1.5 sqmm) single core PVC insulated multistrand FRLSH Grade flexible copper wire through 20 mm PVC conduit pipe/casing by supplying one no. 40 Amp, 10kA, 240/415V,50 HzSPN/DP MCB Isolator conforming to IS / IEC: 60947-3, "C" characteristics. (As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments) with required module PVC Board & piano key type switch. (ave. run 6 mtr). i) LED Tube set point - 2 nos., Bulk Head light point- 1 no., 5 pin 6 Amps. Plug point- 1 no., 16 Amp socket & switch- 1 no,with necy. earthing arrangement & one fan point (Total point 6 nos. points) including drawing power by suitable gauge (2.5 mm2) of copper wire from installed PDB panel to switch board through DB for P/H no. I & from panel to switch board for P/H no. II through 20 mm PVC casing capping (precision make, LMS) as per direction of EIC (fittings should be of Philips make & wiring should be with continuous earthing arrangement and 20W two nos. 4 ft long LED tube light setsPHILIPS /Astra Line /other equivalent make, one no. bulk head, one no. 0-4 step fan regulator (Humfree), fittings etc to be supplied by agency). ( For T/W no. I & II)
42(a) Earthing with 50 mm diameter G.I. pipe 3.64 mm thick x 3Mtr. (10ft.) long and 1 x 4 SWG G.I. wire (4Mtr.long) 13 mm diameter x 80mm (3inch) long G.I. Bolts, double nuts, washer including S & F of 15mm diameter G.I. pipe protection (1 Mtr. Long) to be filled with bitumen partly below ground level to an average depth of 3.65Mtr.(12ft.) below the ground level and restoring the surface duly rammed.i) For soft soil by ISI Medium GI pipe. ( For T/W no. I & II)
43(b) Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm diaholes on the GI pipe. ( For T/W no. I & II)
44(c) Extra for treatment of soil by salt and charcoal coke for pipe electrode. ( For T/W no. I & II)
45(d) Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.Length of busbar is 0.5 mtr. ( For T/W no. I & II)
46(e) Connecting the equipments body to earth busbar including S&F 20 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. ( For T/W no. I & II)
47Supply, delivery and fitting-fixing of 230 volt1200 mm sweep AC ceiling fan withball bearing complete with all accessories such as blade, canopy, fork, down rod etc. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments. ( For T/W no. I & II)
48Trial operation and guarding of the installed pumping machinary after receiving power and commisioning the pumping machinary as per direction of E.I.C i) For t/w no. I(for 90 days)
49ii) For t/w no. II (for 90 days)
50Making compound lighting arrangement and allied works for Head work site i.e. T/W No. I 9 mtr. long swaged steel tabular pole (Designation- 410 SP-26) (Over all length- 9.00 mtr, planting depth- 1.5 mtr), Length of section, Bottom-5.0mtr, Middle- 2.0 mtr, Top- 2.0mtr,) Outside Dia & Thickness of Section (Bottom-114.3x4.50mm, Middle-88.9x4.05mm,Top-76.1x3.25) Approx Weight of Pole - 92Kg. including supply and fixing of C.I. base plate, C.I Cap etc. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments.
51Single arm bracket of 40 mm dia and 1.5 mtr. long. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments.
52Street light luminaire having Single Die ceramic base high power LED light source, IP66 protection, PDC housing with finless design and polycarbobate cover(IK08) with better thermal management/ Potted driver is to be provided,the luminaire and housing should be from the same manufacturer (cat no- BRP062 LED 68 CW SLC S1 PSU/equivalent, LUMEN O/P- 6800, System Efficacy greater than 100 lumen/watt) Make-Philipsor Equivalent and same technical specification of Havells or other apprioved make as per direction of EIC. The manufacturer has to provide LM79/LM80 reports corresponding to the luminaire/LED Chip respectively along with type test Certificate. The luminaire manufacturer should have an in house NABL Accredited testing facility.
53Aesthetically designed post-top LED luminarie having die cast aluminium housing with IP66 protection with resistant to impact and corrosion. (Make :- Havells (RUBY PT35WLED757PSYMTOPC, CORAL (PT35WLED757PSYMTOPC)/ other approved make).
541.1 KV Grade 415 V, 2 core 4 sq.mm. PVC sheathed XLPE insulated Al. armoured cable conforming to IS:7098 (PART-I) 1988 with latest amendmends as applicable. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments.
5532 mm dia G.I. pipe. (ISI - Medium)
56Erection of 9 Mtr Single Steel tubular pole with sole plate & Cap etc. in CC foundation (size 0.6x0.6 x 1.7 mtrs), having 600x600x750 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt and earthing arrangement by 8 SWG GI Wire,after making drilled holes etc. on pole & carriage of pole upto 1.6 KM from store to worksite including filling up the excavated earth pit with shifted soil and ramming properly.
57Extra on item no. 58. above, for providing CC (6:3:1) base block (around the pole) dimension 0.45x0.45x0.60 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/polythene pipe entry as directed for streel light wiring incl. S & F 20 cmx15cmx10 cm G.I. loop box, 16 SWG & incl. drilled hole in pole.
58Supplying & fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint all complete as per direction.
59Fitting-fixing of the above supplied street luminaries (as in item no. 52) at suitable position on wall/pole by using fixing materials including making interconnection by using the Cu wire with making earthing connection from loop box all complete as per entire satisfaction of E.I.C.
60Laying only Cable as in item no. 54 through existing GI Pipe/open masonary trench for 2 core 4 sq. mm.
61Laying of cable as in item no. 54 on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting as directed by EIC. (Cable shall be procured as per site requirement)
62Laying of cable as in item no. 54 in underground trench 460 mm wide x 760 mm average depth, with brick protection onthe top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed all complete as per direction of E.I.C.
63Supplying and fixing of compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of 1.1 KV Gr. 2 core 4 sq.mm XLPE Armored Alu. Cable all complete as per direction of E.I.C.
64Finishing the cable as in item no. 54 by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials all complete as per direction of E.I.C.
65Pole earthing by supply and installation of GI pipe electrode 50 mm dia.and 3.64 mm thick x 3.04 mtr. longincluding suitable gauge G.I. wire and other necessary materials as per general specification and direction of E.I.C.
66Painting all the single arm & double arm G.I brackets, poles (9 mtr.) etc. with 2 coats of Synthetic Enamel paint over 1 coat of Red Oxide primer after cleaning and preparation of surface by emery paper all complete as per direction.
67Fitting fixing of die cast aluminium housing of gate light as in item no. 53 with suitable G.I net protection as per direction of E.I.C
68Add GST @ 18 %
69Add Cess @ 1 %
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail