Tender For Electrical Works At Fsd Lunglei Mizoram For The Year 2022-23. Sh:- Repair, Maintenance Of Electrical Installation And Improvement Of Illumination At Fsd Lunglei, lunglei-Mizoram

Food Corporation Of India-FCI has published Tender For Electrical Works At Fsd Lunglei Mizoram For The Year 2022-23. Sh:- Repair, Maintenance Of Electrical Installation And Improvement Of Illumination At Fsd Lunglei. Submission Date for this Tender is 27-12-2022. Electrical Maintenance Tenders in lunglei Mizoram. Bidders can get complete Tender details and download the document.




Tender Notice

35274278
Tender For Electrical Works At Fsd Lunglei Mizoram For The Year 2022-23. Sh:- Repair, Maintenance Of Electrical Installation And Improvement Of Illumination At Fsd Lunglei
Open Tender
Indian
Mizoram
lunglei
27-12-2022

Tender Details

Tender For Electrical Works At Fsd Lunglei Mizoram For The Year 2022-23. Sh:- Repair, Maintenance Of Electrical Installation And Improvement Of Illumination At Fsd Lunglei

Key Value

Document Fees
Refer document
EMD
INR 22280.0 /-
Tender Value
INR 11.13 Lakhs /-

BOQ Items

Name of Work: Electrical works at FSD Lunglei Mizoramfor the year 2022-23. SH:- Repair, Maintenance of EI and improvement of illumination at FSD Lunglei.
Sl. No. Item Description
1Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.
23 x 1.5 sq. mm
34 x 1.5 sq.mm
43 x 2.5 sq.mm
53 x 4 sq.mm
6Earthing with G.I. earth pipe 4.5 mtr long 40 mm dia including accessories ,and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal /cokeand salt etc as required.
7Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
8Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ sub main wiring/ cable as required.
9Laying and fixing of one No. PVC insulated & PVC sheathed/XLPE al conductor cable of 1.1KV gradeof following size on the wall surface as reqd.(clamped with 1mm thick saddle)
10Upto 35 sq.mm
11Supplying and fixing of following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
12Single pole 10/20 AMP
13Single Pole & neutral32 AMP
14Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular plate, suitable GI box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. as required. Group C.
15Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
162 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
17Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch boxincluding connections but excluding modular plate etc. as required.(Socket Type)
18Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB /Isolator)
196 way, SPN double door
20Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
214 way (4 + 12), Double door
22Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent/LED fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
23Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (Upto 30 CM) with 1.5 Sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
24Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
252 X 10 Sq,mm (19 mm)
26Supplying and fixingfollowing size/modules, G.I box along with modular base & cover plate for modular switches in recess etc. as required
273 Module (100 mm X 75 mm)
2812 Module (200 mm X 150 mm)
29Supplying and fixing following modular switch/socket on the existingmodular plate & switch box including connections but excluding modular plate etc. as required.
301 Way 5/6 Switch
313 pin 5/6 socket outlet
3215/16 A Switch
336 pin 15/16 A Socket outlet
34Supplying and fixing of 32 mm dia X 2.33 meters long G.I. pipe(medium class) bracket for mounting of fluorescent /HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamp with nuts, bolts and washer, paintaing the flat iron with primer and finish paint stc. as required.
35Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
3620 mm dia
3725 mm dia
38Supplying and fixing 5/6 amps switch piano type/tumbler switch/ socket on the existing switch box/ cover including connections etc. as required.
39Supplying of following size XLPE insulated & PVC tape innersheathed aluminium conductor armoured cable of 1.1 KV grade of following size confirming to IS:7098 (Part- I) 1988 with up to date ammendment as required.
402 x 10 Sq.mm
41Supplyingof 1200 mm sweep capacitor type A.C ceiling fan complete with 30 cm down rod withhangingshackle , blade canopy suitable for 230/240 volt, 50 cycles/sec., single phase supply conforming to ISI-374/1966as amended from time to time.
42Supply,installation testing & commissioning of36 Watt cool day light 2ft X 2ft LED surface full lit luminaire with >100 Lumen/Watt
43Supply,installation testing & commissioning of18 Watt cool day light 1ft X 1ft LED surface full lit luminaire with >100 Lumen/Watt
44Supply of LED luminiairefitting with ECO-1 highly robust industrial box type suitable for single T8 LED Tube, LED Tube LGT8-20 Wattswith LED Glass T-8 Tube with in built driver double sided connection including connection, interconnection etc completed as required.
45Supply,installation,testing & commissioning of integral well glass luminaire compressed of dia cast canopygear box housing and glass driver surge with heat resistance glass of LED well glass fitting of 40 watt having 110 Lm/watt to 125 Lm/Wattor Luminous should not be less than 4400 as per direction of Engineer in-chargeas per direction of engineer-In-Charge.
46Supply,installation,testing & commissioning of integral well glass luminaire compressed of dia cast canopygear box housing and glass driver surge with heat resistance glass of LED well glass fitting of 70 watt having110 Lm/watt to 125 Lm/Wattor Luminous should not be less than 7700 as per direction of Engineer in-charge as per direction of engineer-In-Charge.
47Supply of LED street light fitting of 60 watts,AC 240 volts of makemade up of streetlight pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP65 protection complete with all accessories etc
48P/F of cable termination of PVC box of size 20cm X 15cm X 10 cm with compression termination arrangements, 6-10 Amp SP MCB and double natural link etc as required.
49Supplying, Installation, Testing and commissioining of 300mm dia sweep exhaust fan ofHeavy dutywith 1400 RPM speed along withall other accessoriesand fixing the fan on the existing wall including connection etc as required.
50Supplying , installation , testing and commissioning of cubical typepanel made outfrom 2 mm ( 14 SGW) thick CRCA sheet steel size 1000 x 950 x 300 mm, hinged type openable door , and angle iron of 50x 50x 6 mm. and flat iron of 40 x 6 mm.with horizontal and vertical intermediate member’s for mounting of panel, fabricated & factory finished , followed by powder coated painting and provided with gasket to make dust / vermin proof Degree of IP protection shall be IP - 42 or more Inter connections with copper conductor cable with suitable size of thimbles, lugs etc. locking arrangement , detachable gland plate, connection , interconnections with suitable size (200 Amp capacity) 4 stripaluminium busbar and PVC insulated copper conductor cable including and providing and fixing digital type Ampere meter, Voltmeter, Indication LED lamp, Selector switch complete etc. as required.(Having minimum depth 300mm )along withangle iron stand to hold the pane llegsshould be grounted in cement concrete 1 : 3: 6: The panel should incorporating the following items: - 1. MCCB. 4 pole 100 amp. 16 KA ofmake= One 2. MCCB. 3 pole63 amp. 16 KA ofmake= Two3. MCB Double Pole32 Amps =04 Nos 4. 200 amp. rating & 4 strip Al. busbar = one set5.Digital type Ampere meter, Voltmeter, Indication LED lamp, Selector switchdgital , CT’S(withHRC fuse) = 1 Set
51Credit items for old dismantled non functional unserviceable 20/25 mm Steel conduit.
52Credit items for old dismantled non functional unserviceable 16/20W LED Tube Light Fittings
53Credit items for old dismantled non functionalunserviceable 10/20Amps SP MCB
54Credit items for old dismantled non functional 6- 32 Amps unserviceable SPN MCB
55Credit item for oldElectric Panel.