Military Engineer Services-MES has published Tender For Repair/Maintenance Of Lt Distribution System And Connected Items Under Ge West Bareilly. Submission Date for this Tender is 10-01-2023. Garden Tools Tenders in bareilly Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

35259295
Corrigendum : Tender For Repair/Maintenance Of Lt Distribution System And Connected Items Under Ge West Bareilly
Open Tender
Indian
Uttar Pradesh
bareilly
10-01-2023

Tender Details

Tender For Repair / Maintenance Of Lt Distribution System And Connected Items Under Ge West Bareilly -Dismantling / Taking Out Old Mild Steel Channel / Angle Iron As In Cross Arms Fixed To Electric Poles Complete All As Specified And Directed. 2 Dismantling / Taking Out Insulator Of Any Size / Type From Existing Electric Ht / Lt Lines Complete All As Specified And Directed. 3 M&L For Pin Type Insulator Of 65 Mm Dia And 100 Mm High, Porcelain, Vitreous, White, Borwn Or Green Including One Galvanised Mild Steel Spindle , Two Galnvanised Iron Wahers And One Galvanised Iron Nut Complete All As Specified And Directed. 4 Dismantling / Taking Out Old Acsr Conductor Any Size From Existing Overhead Lines Including Disconnection Complete All As Specified And Directed. 5 M & L For Stringing, Stretching And Than Strengthening Of Overhead Conductor ( Acsr ) Of Any Size Or Type On Existing Lt Pole Including Binding And Jointing The Conductor With And Including 14 Swg Binding Wire Complete All As Specified And Directed. 6 M & L For One Coat Of Aluminium Paint Of Approved Quality Including Preparation Of Existing Old Painted Surface Of Steel Tubular Poles Lt Complete Alongwith Flat Iron Clamps, Bracing, Cross Arms Etc. And Writing Number Of Poles With White Synthetic Enamel Paint Over A Circular Black Painted Base Complete All As Specified And Directed. 7 Material And Labour For Cutting Of Bushes And Cleaning The Area Around The Sub Station Including Two Pole / Four Pole Structures Premises Complete All As Specified And As Directed. 8 S & F Pvc ( Moulded Polypropylene ) Line Phase Separator ( For Separating 5 Nos. Of Over Head Line Conductors ) Of Suitable Length With 25 Mm Fly Nuts And Clamps Suitable For 1100 Volts Grade Lt Electric Lines Complete All As Specified And Directed. 9 S & F Pvc ( Moulded Polypropylene ) Line Phase Separator ( For Separating 4 Nos. Of Over Head Line Conductors ) Of Suitable Length With 25 Mm Fly Nuts And Clamps Suitable For 1100 Volts Grade Lt Electric Lines Complete All As Specified And Directed. 10 S & F Pvc ( Moulded Polypropylene ) Line Phase Separator ( For Separating 3 Nos. Of Over Head Line Conductors ) Of Suitable Length With 25 Mm Fly Nuts And Clamps Suitable For 1100 Volts Grade Lt Electric Lines Complete All As Specified And Directed. 11 Excavation In Trenches Not Exc. 1.50 M Wide And Not Exc. 1.50 M In Depth For Laying Cables And Getting Out In Soft / Loose Soil Including Trimming Sides And Forming Bottom Surface To The Required Level / Slope Etc Complete All As Specified And Directed. 12 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc. 25 Cm In Each Layer As In Soil Complete All As Specified And Directed. 13 Removing Excavated Material ( Soil ) To A Distance Not Exc. 50 M And Depositing Where Directed At A Level Not Exc. 1.5 M Above The Starting Point Complete All As Specified And Directed. 14 M&L For Sand Cushioning With Layer Of Sand 8Cm Thick Before Laying Of Cable And 15Cm After Laying Of Cable In Trenches, Punning Complete All As Specified And Directed Note:- Punning Thickness Of 18 Cm Will Be Considered For Payment. 15 M & L For Laying Brick As In Protection Covers Over Cables Using Sub Class B Old Size Bricks Laid Flat, Length Wise Perpendicular To The Axis Of Cable Complete All As Specified And Directed. 16 Laying Only Oldserviceable Bricks Obtained From Taking Out Old Cables Complete All As Specified And Directed. 17 Taking Out Old Defectivecable From Trenches / Floor / Road / Wall / Pipe / Pole / Service Connections Of Any Size , Testing With Lt Magger , Seggregating The Serviceable Part Of Cables And Storefor Relaying Completeall As Specified And Directed. 18 Supply And Laying Xlpe Insulated Screened Pvc Bedded, Galvanised Steel Strip Or Wire Armoured, Electric Power Cable ( Heavy Duty ) With Stranded Aluminium Conductor 1100 Volt Grade, Laid In Trenches / Ducts, Fixed On Wall / Inside Panel, Drawn Through Pipe Of Cross Sectional Area 10 Sqmm 2 Core Completeall As Specified And Directed. 19 All As Per Item No 18.00 Here-In-Before But Cable Size 10 Sqmm 4 Core Complete All As Specified And Directed. 20 All As Per Item No 18.00 Here-In-Before But Cable Size 16 Sqmm 2 Core Complete All As Specified And Directed. 21 All As Per Item No 18.00 Here-In-Before But Cable Size 16 Sqmm 4 Core Complete All As Specified And Directed. 22 All As Per Item No 18.00 Here-In-Before But Cable Size 25 Sqmm 4 Core Complete All As Specified And Directed. 23 All As Per Item No 18.00 Here-In-Before But Cable Size 50 Sqmm 3.5 Core Complete All As Specified And Directed. 24 All As Per Item No 18.00 Here-In-Before But Cable Size 95 Sqmm 3.5 Core Complete All As Specified And Directed. 25 All As Per Item No 18.00 Here-In-Before But Cable Size 120 Sqmm 3.5 Core Complete All As Specified And Directed. 26 All As Per Item No 18.00 Here-In-Before But Cable Size 185 Sqmm 3.5 Core Complete All As Specified And Directed. 27 All As Per Item No 18.00 Here-In-Before But Cable Size 240 Sqmm 3.5 Core Complete All As Specified And Directed.Note For Item No 18.01 To 18.09:- Quoted Unit Rates Shall Deemed Included The Making Connections With Necessary Cable Glands Lugs Etc As Required. 28 Relaying Only Serviceablelt Ug Cable Obtained From Srl Item No 17 Of Scheduleany Size And Description Includingnecessary Cable Glands Lugs As Required Complete All As Specified And Directed.Note:- All Relevent Items Like Excavation, Earth Work, Sand Cushionning, Bricks Etc Shall Be Measured And Paid Seperatly Under Respective Items Of This Schedule. 29 M&L For Straight Through Joints Heat Shrinkble Type 1.1 Kv Suitable For Pvc Insulated And Sheathed Aluminium Conductor Under Ground Cable Of Size 16 To 70 Sqmm 3.5 / 4 Core Including Testing Of Joints After Completion Complete All As Specified And Directed. 30 All As Per Ser Item No 20.00 Here-In-Before But Suitable For Cable Size Of 95 Sqmm To 185 Sqmm, 3.5 Core Complete All As Specified And Directed. 31 All As Per Ser Item No 20.00 Here-In-Before But Suitable For Cable Size Of 240 Sqmm, 3.5 Core Complete All As Specified And Directed. 32 M&L Cutting Of Floor / Wall / Road / Footpath For Removal Of Lt U / G Cable Of Any Size / Description And Making Good The Same As Per Existing Specifications After Relaying Of Cable Complete All As Specified And Directed. 33 M&L For Boring Of Holes Under Road / Pavement / Hard Standing Or Any Other Situation By Mannual Means For 80 / 50 Mm Bore At The Depth Not Less Than 1 Mtr Below Ground Level For Crossing The Cable And Making Good Both The Ends Complete All As Specified And Directed. Note :- Gi Pipe Shall Be Measured And Paid Separately Under Respective Item Of This Schedule. 34 S & F In Replacement 50Mm Bore Gi Pipe Light Grade For Cable Protection, Fixed To Pole / Alongwall / Floor / Under Road / Across The Drain Or Nallaha Etc Complete All As Specified And Directed. 35 All As Per Item No 23.00 Here - In- Before But80 Mm Bore Complete All As Specified And Directed. 36 All As Per Item No 23.00 Here - In- Before But100 Mm Bore Complete All As Specified And Directed. 37 M & L Fabrication Of Ms Busbar Chamber Of Nominal Dimension 900 Mm X 600 Mm X 400 Mm With 2 Mm Thick Sheetduly Provided With Aluminimum Busbar Of Size 50 Mm X 6Mm Fixed On Porcelain Insulators Tpn Type Out Door Weather / Vermin Proof With Both Way Opening Duly Provided With Neoprene Rubber Gasket Along The Doors Openings Pedestal Type Duly Painted Powder Coated On Crca Steel Sheet Encloser With One No Incommer Mccb 250 Amp 36 Ka Incl Making Connection / Thimbles Complete All As Sepcified And Directed. 38 M&L For Stay Assembly Complete With Accessories And Fittings As Shown On Electrical Plate No. 1 Suitable For Stay Rod Of 20 Mm Dia Including Necessary Excavation And Earth Work Complete All As Specified And Directed. 39 Dismantling Stay Assembly Complete From The Pole And Ground Complete All As Specified And Directed. 40 Dismantling Of Lt Pcc / Steel Tubularpole Including Demolition Of Pole Coping, Foundation Etc And Keeping Serviceable Insulators In Safe Custodyfor Reuse Complete All As Specified Anddirected. 41 Supply And Erection, In Truly Vertical Position, Lt Steel Tublar Swaged Pole Complete With Cast Iron Base Plate, Finial Taper Plug, Bolt , Nut And Screwed Type 410-Sp -31 ( 9 Meters Long ) Class -10 Including Painting Of Poles With Two Coats Of Synthatic Enamel Paint In Black And White Strips Upto 1.5 Mtr Height From Coping Over A Coat Of Red Oxide Primer Including Numbering Of Poles As Directed. Make : Bansal / Jindal / National Tube.Note : Pcc, Earth Work And Ms Work As Cross Arms Clamps Etc Shallbe Measured And Paid Separately. 42 M&L For Pcc Type B1 1:2:4 ( Using 20 Mm Graded Aggregate ) As In Coping To The Poles With And Including Necessary Form Work As Required Complete All As Specified And Directed. 43 M&L For Pcc 1:3:6 Type C2 ( Using ( 40 Mm Graded Aggregate ) In Foundation, Filing And Mass Concrete Complete All As Specified And Directed. 44 M&L For Cross Arms, Bracings, Supports, Clamps And Back Plates Fabricated From Structural Steel Sections Including Nuts, Bolts, Washers Welding, Bending Cold Or Hot, Drilling Holes For Bolts, In Any Hape Or Size As Indicated Or Directed Duly Painted With Two Coats Of Synthic Enamel Paint Over One Coat Of Red Oxide Primer Complete All As Specified And Directed. 45 Removal Of Tree Fallen On Ht / Lt Overhead Lines By Cutting Branches, Bushes By Electric Cutter Or Manual And Lifted By Crane / Hydra / Manually Including Collection And Depositing The Retrieved Timberat A Place As Directed By Engineer-In-Charge. 46 Lopping / Prooning Of Tree Branches Upto The Extend To Obtain Clearance All Around The Lt Over Head Lines / Ht Over Head Linesconductor Upto 3 Meters From Furthest Conductor On Pole Including Removing Of Cut Branches And Cleaning Of Site Complete All As Specified And Directed. 47 Opening The Binding Wire From Pin / Shackle Insulator On Steel Pole Of Any Height For Re-Stretching The Acsr Conductor , After Re-Stretching Without Kinks & Bends, Binding The Pin / Shackle Insulator With Appropriate Size Of Aluminium Binding Wire Complete All Specified & Directed By Engineer-In- Charge.Note: 1. Cost Of Binding Wire Deemed To Be Included In The Quoted Rate, No Extra Amount Will Be Paid. 2. One Rm Length Will Be Measured For 03 Phase And One Neutral One Street Light And One Earth Wire. 48 Disconnection Of Electric Connection From Lt Panel Of Any Size Dressing Of Cable Including Replacement Of Burnt Out Aluminium Lugs And Fixing With New Lugs, Nuts Bolt Etc Complete Including All Inter Connection With Aluminium Strip Of Size Not Less Than 0.6Mx0.03Mx6mm 1100 Volts Grade And Suitable Current Ratingincluding Painting Of Panels Complete With Inner & Outer With Two Coats Ofsynthetic Enamelled Paintover A Coat Of Primer Including Excavation & Earth Work Required For Taking Out & Refixing The Incoming And Out Going Cable Etc Complete Allas Directed By Engr -In Charge; Note :-Replacement Of Unserviceable Accessories Parts Shall Be Measured And Paid Separately Under Relevent Items. 49 S&F In Replacement Mccb 415 Volts 4 Pole 630 Amps 50 Hz 50 Ka Of Existing Make Model And Typealonwith Spreader Terminal With Adjustable Thermal Settingincluding Lugs / Thimbles Of Suitable Size In Existing Panels Complete All As Specified And Directed. Make Of Mccbs - L&T / Legrand / Havells / C&S. 50 All As Per Item No 36.00 But Mccb 400 Amp 36 Ka 4 Pole Adjustable Type 415 Volts 50 Hz. Complete All As Specified And Directed. 51 All As Per Item No 36.00 But Mccb 250 Amp 36 Ka 4 Pole Adjustable Type415 Volts 50 Hz Complete All As Specified And Directed. 52 All As Per Item No 36.00 But Mccb 200 Amp 36 Ka 4 Pole Adjustable Type415 Volts 50 Hz Complete All As Specified And Directed. 53 All As Per Item No 36.00 But Mccb 125 Amp 25 Ka 4 Pole Adjustable Type415 Volts 50 Hz Complete All As Specified And Directed. 54 All As Per Item No 36.00 But Mccb 63 Amp 16 Ka 4 Pole415 Volts 50 Hz Complete All As Specified And Directed. 55 S&F In Replacement Of Following Unserviceable Parts Of Lt Panels Complete All As Specfied And Directed:- 56 Aluminium Bus Bar 600Ampere With Colour Code & Porcelain Insulatorcompletesuitable For 3 Phase 4 Wire System Oflengthnot Less Than 1 Metre. 57 Phase Indicator Lamb Ryb . 58 Volt Meter 0-500 Volts With Selector Switch. 59 Ampere Meter 0-600 Ampere With Selector Switch. 60 S & Frubber Mat Of Size 2M X 1M X 12Mm Thick At Electric Supply Installations Complete All As Specified And Directed. 61 S&F In Replacement 1100 Volts Grade Pvc Insulated Aluminium Conductor Screened Served With Inner Sheathed In Service Connection Flat Twin Core Cable Of Size 10 Sqmm Complete All As Specified And Directed. 62 All As Per Item No 39.00 Here-In-Before But 06 Sqmm Twin Core Complete All As Specified And Directed 63 M&L For Earthing Complete With Galvanised Iron Steel Earth Plate Of Size600 X 600 X 3.15 Mm Thick Burried Directly In Ground ( Earth Pit Not Less 2.25 Metre Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Metre Below Ground Level Connected To Thick Electrode And 32X6 Mm Gi Strip As Earthingby Means Of Nuts Bolts Check Nuts And Washers Made Of Galvanised Iron Or Steel Earth Wire Protected By Galvanised Iron Pipe 15 Mm Bore ( Medium Grade ) And Connected To Main Switch Board Or Main Control Board As Directed And Including Concrete Pit In Pcc ( 1:3:6 ) Type C1 Precast Rcc Cover Slab 54 X 54 Cm X 5 Cm With Reinforcement With 8 Mm Tmt Bars @ 150 C / C With One Handle And Funnel For Watering Charcoal Or Coke And Salt In Alternate Layers & Necessary Earth Work In Soft / Loose Soil Complete All As Shwon In Electrical Plate No 5 Of Ssr Part-I Including Testing On Completion All As Specified And Directed. 64 Notes : ( I ) Complaints Pertaining To Lt External Electric Supply Shall Be Resolved By The Contractor Immediatelly After Getting Complaints. In Case Of Failure On The Part Of Contractor To Resolve To The Complaints Within Stipulated Time, A Penalty Of Rs 1000 / - Per Day Per Complaint Shall Be Imposed From The Contractor. ( Ii ) The Contractor Or His Authorised Representative Shall Report To The Concerned Je E / M At 0900 Hours Dailly On All Working Days To Receive Order / Instructions Of The Work. A Register Shall Be Maintained To Record All Orders & Instructions And Their Complaints And Is To Be Signed By The Contractor / His Representative And The Engineer-In-Charge / Je E / M Concerned. ( Iii ) Work Done Register To Be Maintained By The Contrator. A Separate Docket Complaints Slip Book Shall Maintained By The Contractor To Note The Complaints / Jobs And Get It Signed By The User After Completion Of Work And Submits To The Je-In-Charge.Note:-Tenderers May Note That Amount Of Credit Rs 2, 31, 614.00 Will Be Deducted From The Total Amount Arrived At The Time Of Acceptance Of Tender.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 49 Lakhs /-

BOQ Items

NAME OF WORK: - REPAIR/MAINT OF LT DISTRIBUTION SYSTEM AND CONNECTED ITEMS UNDER GE WEST BAREILLY.
Sl. No. Item Description
1Dismantling / taking out old mild steel channel / angle iron as in cross arms fixed to electric poles complete all as specified and directed.
2Dismantling / taking out insulator of any size / type from existing electric HT / LT lines complete all as specified and directed.
3M&L for Pin type insulator of 65 mm dia and 100 mm high, porcelain, vitreous, white, borwn or green including one galvanised mild steel spindle , two galnvanised iron wahers and one galvanised iron nut complete all as specified and directed.
4Dismantling / taking out old ACSR conductor any size from existing overhead lines including disconnection complete all as specified and directed.
5M & L for stringing, stretching and than strengthening of overhead conductor (ACSR) of any size or type on existing LT pole including binding and jointing the conductor with and including 14 SWG binding wire complete all as specified and directed.
6M & L for one coat of aluminium paint of approved quality including preparation of existing old painted surface of steel tubular poles LT complete alongwith flat iron clamps, bracing, cross arms etc. and writing number of poles with white synthetic enamel paint over a circular black painted base complete all as specified and directed.
7Material and labour for Cutting of bushes and cleaning the area around the sub station including two pole/four pole structures premises complete all as specified and as directed.
8S & F PVC (moulded polypropylene) line phase separator (for separating 5 Nos. of over head line conductors) of suitable length with 25 mm fly nuts and clamps suitable for 1100 volts grade LT electric lines complete all as specified and directed.
9S & F PVC (moulded polypropylene) line phase separator (for separating 4 Nos. of over head line conductors) of suitable length with 25 mm fly nuts and clamps suitable for 1100 volts grade LT electric lines complete all as specified and directed.
10S & F PVC (moulded polypropylene) line phase separator (for separating 3 Nos. of over head line conductors) of suitable length with 25 mm fly nuts and clamps suitable for 1100 volts grade LT electric lines complete all as specified and directed.
11Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for laying cables and getting out in soft / loose soil including trimming sides and forming bottom surface to the required level / slope etc complete all as specified and directed.
12Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in each layer as in soil complete all as specified and directed.
13Removing excavated material (soil) to a distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
14M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches, punning complete all as specified and directed Note:- Punning thickness of 18 cm will be considered for payment.
15M & L for laying brick as in protection covers over cables using sub class "B" old size bricks laid flat, length wise perpendicular to the axis of cable complete all as specified and directed.
16Laying only oldserviceable bricks obtained from taking out old cables complete all as specified and directed.
17Taking out old defectivecable from trenches/ floor/road/wall/pipe/pole /service connections of any size , testing with LT magger , seggregating the serviceable part of cables and storefor relaying completeall as specified and directed.
18Supply and laying XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volt grade, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe of cross sectional area 10 Sqmm 2 core completeall as specified and directed.
19All as per item No 18.00 here-in-before but cable size 10 Sqmm 4 core complete all as specified and directed.
20All as per item No 18.00 here-in-before but cable size 16 Sqmm 2 core complete all as specified and directed.
21All as per item No 18.00 here-in-before but cable size 16 Sqmm 4 core complete all as specified and directed.
22All as per item No 18.00 here-in-before but cable size 25 Sqmm 4 core complete all as specified and directed.
23All as per item No 18.00 here-in-before but cable size 50 Sqmm 3.5 core complete all as specified and directed.
24All as per item No 18.00 here-in-before but cable size 95 Sqmm 3.5 core complete all as specified and directed.
25All as per item No 18.00 here-in-before but cable size 120 Sqmm 3.5 core complete all as specified and directed.
26All as per item No 18.00 here-in-before but cable size 185 Sqmm 3.5 core complete all as specified and directed.
27All as per item No 18.00 here-in-before but cable size 240 Sqmm 3.5 core complete all as specified and directed. NOTE FOR ITEM NO 18.01 TO 18.09:- Quoted unit rates shall deemed included the making connections with necessary cable glands lugs etc as required.
28Relaying only serviceableLT UG Cable obtained from Srl item No 17 of scheduleany size and description includingnecessary cable glands lugs as required complete all as specified and directed.Note:- All relevent items like excavation, earth work, sand cushionning, bricks etc shall be measured and paid seperatly under respective items of this schedule.
29M&L for Straight through joints heat shrinkble type 1.1 KV suitable for PVC insulated and sheathed aluminium conductor under ground cable of size 16 to 70 Sqmm 3.5 / 4 core including testing of joints after completion complete all as specified and directed.
30All as per Ser item No 20.00 here-in-before but suitable for cable size of 95 Sqmm to 185 Sqmm, 3.5 core complete all as specified and directed.
31All as per Ser item No 20.00 here-in-before but suitable for cable size of 240 Sqmm, 3.5 core complete all as specified and directed.
32M&L Cutting of floor/wall/road/footpath for removal of LT U/G cable of any size/description and making good the same as per existing specifications after relaying of cable complete all as specified and directed.
33M&L for Boring of holes under road /pavement/hard standing or any other situation by mannual means for 80/50 mm bore at the depth not less than 1 mtr below ground level for crossing the cable and making good both the ends complete all as specified and directed. Note :- GI pipe shall be measured and paid separately under respective item of this schedule.
34S & F in replacement 50mm bore GI pipe light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified and directed.
35All as per Item No 23.00 here - in- before but80 mm bore complete all as specified and directed.
36All as per Item No 23.00 here - in- before but100 mm bore complete all as specified and directed.
37M & L fabrication of MS busbar chamber of nominal dimension 900 mm x 600 mm x 400 mm with 2 mm thick sheetduly provided with aluminimum busbar of size 50 mm x 6mm fixed on porcelain insulators TPN type out door weather/vermin proof with both way opening duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA steel sheet encloser with one No incommer MCCB 250 Amp 36 KA incl making connection /thimbles complete all as sepcified and directed.
38M&L for stay assembly complete with accessories and fittings as shown on electrical plate No. 1 suitable for stay rod of 20 mm dia including necessary excavation and earth work complete all as specified and directed.
39Dismantling stay assembly complete from the pole and ground complete all as specified and directed.
40Dismantling of LT PCC/steel tubularpole including demolition of pole coping,foundation etc and keeping serviceable insulators in safe custodyfor reuse complete all as specified anddirected.
41Supply and erection, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate, finial taper plug, bolt , nut and screwed type 410-SP -31(9 meters long ) Class -10 including painting of poles with two coats of synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed. Make : Bansal/ Jindal/ National tube.Note : PCC, Earth work and MS work as cross arms clamps etc shallbe measured and paid separately.
42M&L for PCC type B1 1:2:4 (using 20 mm graded aggregate) as in coping to the poles with and including necessary form work as required complete all as specified and directed.
43M&L for PCC 1:3:6 type C2 (using (40 mm graded aggregate) in foundation, filing and mass concrete complete all as specified and directed.
44M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts, in any hape or size as indicated or directed duly painted with two coats of synthic enamel paint over one coat of red oxide primer complete all as specified and directed.
45Removal of Tree fallen on HT/LT overhead lines by cutting branches,bushes by electric cutter or manual and lifted by crane /Hydra/Manually including collection and depositing the retrieved timberat a place as directed by Engineer-in-charge.
46Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines / HT over head linesconductor upto 3 meters from furthest conductor on pole including removing of cut branches and cleaning of site complete all as specified and directed.
47Opening the binding wire from pin /shackle insulator on steel pole of any height for re-stretching the ACSR conductor , after re-stretching without kinks & bends, binding the pin /shackle insulator with appropriate size of aluminium binding wire complete all specified & directed by Engineer-in- charge. Note: 1. Cost of binding wire deemed to be included in the quoted rate, No extra amount will be paid. 2. One RM length will be measured for 03 phase and one neutral one street light and one earth wire.
48Disconnection of electric connection from LT Panel of any size dressing of cable including replacement of burnt out aluminium lugs and fixing with new lugs, nuts bolt etc complete including all inter connection with aluminium strip of size not less than 0.6Mx0.03Mx6MM 1100 volts grade and suitable current ratingincluding painting of Panels complete with inner & outer with two coats ofsynthetic enamelled paintover a coat of primer including excavation & earth work required for taking out & refixing the incoming and out going cable etc complete allas directed by Engr -in Charge; Note :-Replacement of unserviceable accessories parts shall be measured and paid separately under relevent items.
49S&F in replacement MCCB 415 Volts 4 pole 630 Amps 50 Hz 50 KA of existing make model and typealonwith spreader terminal with adjustable thermal settingincluding lugs/thimbles of suitable size in existing panels complete all as specified and directed. Make of MCCBs - L&T/Legrand /Havells/C&S.
50All as per Item No 36.00 but MCCB 400 Amp 36 KA 4 pole adjustable type 415 Volts 50 Hz. Complete all as specified and directed.
51All as per Item No 36.00 but MCCB 250 Amp 36 KA 4 pole adjustable type415 Volts 50 Hz Complete all as specified and directed.
52All as per Item No 36.00 but MCCB 200 Amp 36 KA 4 pole adjustable type415 Volts 50 Hz Complete all as specified and directed.
53All as per Item No 36.00 but MCCB 125 Amp 25 KA 4 pole adjustable type415 Volts 50 Hz Complete all as specified and directed.
54All as per Item No 36.00 but MCCB 63 Amp 16 KA 4 pole415 Volts 50 Hz Complete all as specified and directed.
55S&F in replacement of following unserviceable parts of LT Panels complete all as specfied and directed:-
56Aluminium bus bar 600Ampere with colour code & porcelain insulatorcompletesuitable for 3 phase 4 wire system oflengthnot less than 1 Metre.
57Phase Indicator lamb RYB .
58Volt meter 0-500 Volts with selector switch.
59Ampere meter 0-600 Ampere with selector switch.
60S & FRubber Mat of size 2m x 1m x 12mm thick at Electric Supply installations complete all as specified and directed.
61S&F in replacement 1100 volts grade PVC insulated aluminium conductor screened served with inner sheathed in service connection flat twin core cable of size 10 sqmm complete all as specified and directed.
62All as per item No 39.00 here-in-before but 06 sqmm twin core complete all as specified and directed
63M&L for earthing complete with galvanised iron steel earth plate of size600 x 600 x 3.15 mm thick burried directly in ground (earth pit not less 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below ground level connected to thick electrode and 32x6 mm GI strip as earthingby means of nuts bolts check nuts and washers made of galvanised iron or steel earth wire protected by galvanised iron pipe 15 mm bore (medium grade) and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 precast RCC cover slab 54 x 54 cm x 5 cm with reinforcement with 8 mm TMT bars @ 150 C/C with one handle and funnel for watering charcoal or coke and salt in alternate layers & necessary earth work in soft/loose soil complete all as shwon in electrical plate No 5 of SSR Part-I including testing on completion all as specified and directed.
64NOTES : (i) Complaints pertaining to LT External Electric Supply shall be resolved by the contractor immediatelly after getting complaints. In case of failure on the part of contractor to resolve to the complaints within stipulated time, a penalty of Rs 1000/- per day per complaint shall be imposed from the contractor. (ii)The contractor or his authorised representative shall report to the concerned JE E/M at 0900 hours dailly on all working days to receive order/instructions of the work. A register shall be maintained to record all orders & instructions and their complaints and is to be signed by the contractor/his representative and the Engineer-in-charge/JE E/M concerned. (iii) Work done register to be maintained by the contrator. A separate Docket complaints slip book shall maintained by the contractor to note the complaints/jobs and get it signed by the user after completion of work and submits to the JE-in-Charge. NOTE:-Tenderers may note that amount of credit Rs 2,31,614.00 will be deducted from the total amount arrived at the time of Acceptance of tender.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail